Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber attack”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Precursor Analysis Report: Ryuk Ransomware Attack on Universal Health Services 2020

The Ryuk Ransomware Attack on Universal Health Services (UHS) 2020 Precursor Analysis Report leverages publicly available information about the 2020 UHS cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. UHS manages over 400 hospitals and is one of the largest healthcare providers in the United States with 3.5 million patients each year. On 27 September 2020, UHS suffered a widespread ransomware attack that resulted in a denial of service to critical internet-dependent healthcare systems including workstations, phones, and data centers. Employees resorted to filing patient details with pen and paper, while other facilities had to redirect ambulances and urgent patients to other facilities for adequate care. Adversaries carried out the attack with Ryuk, a ransomware that encrypts data and generates a RyukReadMe.txt ransom note with the ransom fee to decrypt the data, varying from 15 Bitcoin (BTC) to 50 BTC, equivalent to roughly $\$$353,892 to $\$$964,617. UHS did not pay the ransom and was able to recover data through backups, but still reported an impact of $\$$67 million dollars in recovery costs. On 29 October, one month after the attack, UHS made an official statement that their systems had been restored and they were resuming normal operations. Researchers and analysts identified 18 unique techniques (used in a sequence of 19 steps) utilized during the attack with a total of 185 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Fourteen of the identified techniques used during the UHS cyber attack were precursors to the triggering event. Analysis identified 106 observables associated with these precursor techniques, 82 of which were assessed to have an increased likelihood of being perceived in the 30 days to two hours preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Implementation of an ICS Ransomware Testbed: Scenarios, Variants, and Evaluation Methods

Ransomware attacks on Industrial Control Systems (ICS) have emerged as a formidable threat to the United States’ critical infrastructure, eliciting grave concerns regarding national security. In March 2023, the FBI Internet Crime Complaint Center (IC3) unveiled its 2022 Internet Crime Report, highlighting a concerning 870 complaints related to ransomware impacting U.S. critical infrastructure. Of the country's 16 critical infrastructure sectors, 14 encountered at least one ransomware attack. Notably, while the Healthcare and Public Health sector suffered the most, reporting 210 attacks, sectors pivotal to ICS networks and governmental organizations were also targeted: the Defense Industrial Base reported 1 attack, Water and Wastewater Systems 3, Chemical 19, Energy 15, Government Facilities 115, and Critical Manufacturing 157. For instance, a ransomware attack on a major chemical company could jeopardize not only its production but also pose environmental risks should systems controlling hazardous materials be compromised. In 2022, three ransomware variants predominantly targeted U.S. critical infrastructure: HIVE, with 87 attacks; ALPHV/BlackCat, with 114; and LOCKBIT, with 149. Several cyber-attacks, such as the MOVEit data breach in May 2023 and the Colonial Pipeline ransomware attack in May 2021, have been so impactful that they commanded national attention. The DarkSide hacking group's assault on the Colonial Pipeline, initiated on May 6th, 2021, stands as one of the most substantial and publicly acknowledged cyber-attacks against U.S. critical infrastructure. The group exploited an exposed Virtual Private Network (VPN) password, paving the way for initial intrusion and subsequent data theft. A mere day later, DarkSide unleashed a ransomware attack that compromised vital accounting and billing systems, prompting an immediate shutdown of the pipeline to mitigate further ransomware proliferation across its network. This crisis spurred a robust response from the U.S. president and regulators, culminating in a national emergency declaration related to the pipeline shutdown on May 9th, 2021. This incident mirrors the 2017 NotPetya ransomware attack that significantly impacted the shipping giant Maersk, highlighting an urgent need for fortified cybersecurity across various industries. Future incidents, akin to the Colonial Pipeline attack, could potentially be mitigated—or entirely averted—should government agencies and private entities scrutinize system vulnerabilities, exploring various ransomware types and entry points. Proactive measures, such as conducting experiments on VPN accounts or auditing passwords to pinpoint duplicate usage across diverse systems and software, might illuminate feasible entry points and vulnerability zones within an organization's systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Computational Techniques for Improving Resilience of Critical Energy Infrastructure under Cyber-Physical Attacks

In this chapter, we present recent advances in improving the resilience of cyber-physical systems, especially with regards to energy systems. We provide discussions around various types of cyber-physical events that can cause disruptions and new advances in optimization, control, and reinforcement learning (RL) to deal with the challenges posed by such cyber-physical events. The presented methods range from distributed robust optimization, autonomous and coordinated control, reinforcement learning based resilient control and topology reconfiguration in Inter-System resilient control.

Nazir, Mohammad Nawaf [BATTELLE (PACIFIC NW LAB)]↗

Network Security Challenges and Countermeasures for Software-Defined Smart Grids: A Survey

The rise of grid modernization has been prompted by the escalating demand for power, the deteriorating state of infrastructure, and the growing concern regarding the reliability of electric utilities. The smart grid encompasses recent advancements in electronics, technology, telecommunications, and computer capabilities. Smart grid telecommunication frameworks provide bidirectional communication to facilitate grid operations. Software-defined networking (SDN) is a proposed approach for monitoring and regulating telecommunication networks, which allows for enhanced visibility, control, and security in smart grid systems. Nevertheless, the integration of telecommunications infrastructure exposes smart grid networks to potential cyberattacks. Unauthorized individuals may exploit unauthorized access to intercept communications, introduce fabricated data into system measurements, overwhelm communication channels with false data packets, or attack centralized controllers to disable network control. An ongoing, thorough examination of cyber attacks and protection strategies for smart grid networks is essential due to the ever-changing nature of these threats. Previous surveys on smart grid security lack modern methodologies and, to the best of our knowledge, most, if not all, focus on only one sort of attack or protection. This survey examines the most recent security techniques, simultaneous multi-pronged cyber attacks, and defense utilities in order to address the challenges of future SDN smart grid research. The objective is to identify future research requirements, describe the existing security challenges, and highlight emerging threats and their potential impact on the deployment of software-defined smart grid (SD-SG).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Self-Healing Attack-Resilient PMU Network for Power System Operation

In this paper, we propose a self-healing phasor measurement unit (PMU) network that exploits the features of dynamic and programmable configuration in a software-defined networking infrastructure to achieve resiliency against cyber-attacks. After a cyber-attack, the configuration of network switches is changed to isolate the compromised PMUs/phasor data concentrators to prevent further propagation of the attack; meanwhile, the disconnected yet uncompromised PMUs will be reconnected to the network to "self-heal" and thus restore the observability of the power system. Specifically, we formulate an integer linear programming model to minimize the overhead of the self-healing process (e.g., the recovery latency), while considering the constraints of power system observability, hardware resources, and network topology. We also propose a heuristic algorithm to decrease the computational complexity. Case studies of a PMU network based on the IEEE 30-bus and 118-bus systems are used to validate the effectiveness of the self-healing mechanism.

Cybersecurity↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Precursor Analysis Report: Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016

The Industroyer Targeting Ukraine Electric Power Transport Utility (Ukrenergo) 2016 Precursor Analysis Report leverages publicly available information about the December 2016 cyber attack against the Ukrainian Ukrenergo electric transmission utility and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. Industroyer is a modular malware framework designed to deploy several Industrial Control System (ICS) protocol-specific attack payloads to disrupt electricity distribution. Adversaries deployed Industroyer within the target network on a Microsoft Windows endpoint capable of directly manipulating or communicating with ICS. Industroyer abuses the functionality of a targeted ICS’s legitimate control system to achieve its intended impact. Adversaries likely first gained access to Ukrenergo enterprise networks in early 2016 after a successful spearphishing campaign against organizations in the electric power sector. Adversaries then began capturing credentials beginning on 1 December 2016. This allowed access to the ICS environment at the Pivnichna electric transmission substation outside Kyiv through a device dual-homed on the Information Technology (IT) and ICS networks. Adversaries conducted discovery, targeting, and access to this device using information and previously captured credentials from compromised enterprise IT machines. Finally, the adversaries deployed and launched the Industroyer malware just before midnight on 17 December. By midnight, Ukrenergo had lost control of a targeted substation, resulting in electric power outages for over an hour in the city of Kyiv and the Kyiv region. Researchers and analysts identified 31 unique techniques (used in a sequence of 33 steps) utilized during the attack with a total of 846 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-nine of the identified techniques used during the Industroyer cyber attack were precursors to the triggering event. Analysis identified 548 observables associated with these precursor techniques, 353 of which were assessed to have an increased likelihood of being perceived in the 300 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

ARCADE (Advanced Reactor Cyber Analysis and Development Environment)

SAND2025-11780O ARCADE (Advanced Reactor Cyber Analysis and Development Environment) software performs cybersecurity experiments on Defensive Cyber Security Architectures (DCSA) for Distributed Control Systems (DCSs). The application is integrated into a cohesive environment that performs cyber risk analyses and reduces costs. ARCADE can investigate the entire cyber-attack surface of a DCS from the physics of control, down to the firmware of individual components with automated efficiency. ARCADE has five major functional components: the Data Broker system, the virtualization environment, the cyber-attack simulator, the cyber-physical analysis system, and the physics simulator. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Valme, Romuald↗

Cybersecurity for distributed energy resources and smart inverters

The increased penetration of distributed energy resources (DER) will significantly increase the number of devices that are owned and controlled by consumers and third parties. These devices have a significant dependency on digital communication and control, which presents a growing risk from cyber attacks. This paper proposes a holistic attack-resilient framework to protect the the integrated DER and the critical power grid infrastructure from malicious cyber attacks, helping ensure the secure integration of DER without harming the grid reliability and stability. Specifically, we discuss the architecture of the cyber-physical power system with a high penetration of DER and analyze the unique cybersecurity challenges introduced by DER integration. Next, we summarize important attack scenarios against DER, propose a systematic DER resilience analysis methodology, and develop effective and quantifiable resilience metrics and design principles. Lastly, we introduce attack prevention, detection, and response measures specifically designed for DER integration across cyber, physical device, and utility layers of the future smart grid.

97 MATHEMATICS AND COMPUTING↗

Toward a Cyber Resilient and Secure Microgrid Using Software-Defined Networking

To build a resilient and secure microgrid in the face of growing cyber-attacks and cyber-mistakes, we present a software-defined networking (SDN)-based communication network architecture for microgrid operations. We leverage the global visibility, direct networking controllability, and programmability offered by SDN to investigate multiple security applications, including self-healing communication network management, real-time and uncertainty-aware communication network verification, and specification-based intrusion detection. We also expand a novel cyber-physical testing and evaluation platform that combines a power distribution system simulator (for microgrid energy services) and an SDN emulator with a distributed control environment (for microgrid communications). Experimental results demonstrate that the SDN-based communication architecture and applications can significantly enhance the resilience and security of microgrid operations against the realization of various cyber threats.

critical infrastructure protection↗

Use of Multi-attribute Utility Functions in Evaluating Security Systems

In analyzing security systems, we are concerned with protecting a building or facility from an attack by an adversary. Typically, we address the possibility that an adversary could enter a building and cause damage resulting in an immediate loss of life, or at least substantial disruption in the operations of the facility. In response to this setting, we implement security systems including devices, procedures, and facility upgrades designed to (a) prevent the adversary from entering, (b) detect and neutralize him if he does enter, and (c) harden the facility to minimize damage if an attack is carried out successfully. Although we have cast this in terms of physical protection of a building, the same general approach can be applied to non-physical attacks such as cyber attacks on a computer system. A rigorous analytic process is valuable for quantitatively evaluating an existing system, identifying its weaknesses, and proposing useful upgrades. As such, in this paper we describe an approach to assess the degree of overall protection provided by security measures. Our approach evaluates the effectiveness of the individual components of the system, describes how the components work together, and finally assesses the degree of overall protection achieved. This model can then be used to quantify the amount of protection provided by existing security measures, as well as to address proposed upgrades to the system and help identify a robust and cost effective set of improvements. Within the model, we use multiattribute utility functions to perform the overall evaluations of the system.

99 GENERAL AND MISCELLANEOUS↗

Defending the Power Grid from Hackers

A new initiative underway at the National Renewable Energy Laboratory is intended to prevent hackers from gaining control of parts of the nation's power grid, potentially damaging electrical equipment and causing localized power outages. Our nation's power grid is evolving to be more responsive to changing power needs, more able to integrate renewable energy, more efficient, and more reliable. One key element of this evolution is adding communication and control devices to the power grid, closer to the end user, so that utilities have greater situational awareness of the grid and can respond quickly to disturbances. But these new devices and their communications requirements can also open up the power grid to potential cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Resilient Flexible Alternating Current Transmission Systems (XFACTS)

This report summarizes the activities conducted under the DOE-OE funded project DEOE0000897, Cyber Attack Resilient Flexible AC Systems – XFACTS. Hitachi Energy (HE), in collaboration with ABB Inc. (ABB), Bonneville Power Administration (BPA), University of Illinois at Urbana-Champaign (UIUC), Iowa State University (ISU), and University of Idaho (UI) pursued the development of a system of defense for Flexible Alternating current Transmission Systems against cyber-attacks (XFACTS). A FACTS substation enhanced with XFACTS defense mechanisms will be capable of mitigating cyberattacks especially those that seek to control electrical parameters like voltage or current and interrupt the power flow in AC lines. It empowers existing FACTS controllers and associated intelligent electronic devices to detect and mitigate malicious intents to depress system voltages, destabilize power flows, trip AC circuit breakers, corrupt currents, and voltages, even if the malicious commands and the measurements have correct syntax. The XFACTS functions utilize the physics of active power electronic systems, control and protection, electric power engineering principles, and state estimation to bring more in-depth cyber defense closer to the protected FACTS substation devices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SDN-Based Smart Cyber Switching (SCS) for Cyber Restoration of a Digital Substation

In recent years, critical infrastructure and power grids have increasingly been targets of cyber-attacks, causing widespread and extended blackouts. Digital substations are particularly vulnerable to such cyber incursions, jeopardizing grid stability. This paper addresses these risks by proposing a cybersecurity framework that leverages software-defined networking (SDN) to bolster the resilience of substations based on the IEC- 61850 standard. The research introduces a strategy involving smart cyber switching (SCS) for mitigation and concurrent intelligent electronic device (CIED) for restoration, ensuring ongoing operational integrity and cybersecurity within a substation. The SCS framework improves the physical network’s behavior (i.e., leveraging commercial SDN capabilities) by incorporating an adaptive port controller (APC) module for dynamic port management and an intrusion detection system (IDS) to detect and counteract malicious IEC-61850-based sampled value (SV) and generic object-oriented system event (GOOSE) messages within the substation’s communication network. The framework’s effectiveness is validated through comprehensive simulations and a hardware-in-the-loop (HIL) testbed, demonstrating its ability to sustain substation operations during cyber-attacks and significantly improve the overall resilience of the power grid.

Liu, Chen-Ching (ORCID:0000000289417958)↗

Identification of the accident-related critical digital assets based on probabilistic safety analysis results - 225

Digital I and C systems have been developed and installed in nuclear power plants, and due to installation of the digital I and C systems, cyber security concerns are increasing in nuclear industry. However, there are too many critical digital assets (CDAs) to be inspected in digitalized NPPs. In order to reduce the inefficiency of regulation in nuclear facilities, the critical digital assets that are directly related to an accident are elicited by using the probabilistic safety assessment results. Target initial events are selected, and their heading are analyzed through event tree analysis. Among the headings, the headings that can be proceeded directly to the core damage by the cyber-attack are finally selected as the target of deriving the minimum cut-sets. Based on success criteria of each heading, we analyze the fault trees and derive the minimum set-cuts. In terms of original PSA, the value of probability for the cut-sets is important but the probability is not important in terms of cyber security of NPPs. The important factors is the number of basic events consisting of the minimal cut-sets that is proportional to vulnerability. Finally, the process for identifying accident-related CDAs is suggested based on PSA results. The results of this study are expected to be used to derive the linkage between cyber-attack and accident, and to develop the final core digital asset identification methodology and effective regulatory method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Moving Target Defense Routing for SDN-enabled Smart Grid

The increasing attack surface area in the smart grid communication networks is making the grid more susceptible to cyber attacks that can lead to instability of the grid and even blackouts. While there are multiple types of cyber attacks that can impact the grid, Denial of Service (DoS) attacks are relatively easier to inject as they require lesser knowledge about the system as compared to data integrity attacks. Various research works showcase methods to prevent or mitigate the impacts of DoS attacks in the smart grid but the research still lacks in demonstrating the feasibility and efficacy of the solutions in a real-world environment. In this paper, we propose a Moving Target Defense (MTD)-enabled Software Defined Network (SDN) for the Smart Grid communication implemented on a Hardwarein- the-Loop (HIL) Testbed. We showcase the implementation of the proposed architecture of MTD-enabled SDN using Mininet 2.3.0 which enables communication between the physical grid and the control center. The results show the advantages of using MTD based on SDN for the wide-area network (WAN) with much lower packet drop percentages in the case of MTD-based routing in the SDN WAN. Index Terms—SDN,

97 MATHEMATICS AND COMPUTING↗

Development of cyber security test scenario for non-safety display system - 226

In order to test the cyber security of NPP related to safety, the results of probabilistic safety assessment were used. The fault tree (FT) is used to reflect the impact of the cyber-attack on the operator. The cyber security test should be performed focusing on the scenario derived from the FT. The concept of a security case has been introduced. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗