Search NASA⌕ Search

SEARCH · Search NASA

Results for “cyber-attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

210 records · Page 12

OT Operational Anomaly Detection (OAD) T&D + DER

The growth of utility-scale renewable energy resources, distributed energy resources (DER), and transportation electrification has increased uncertainty and cybersecurity risks in power grids. The Purdue Enterprise Reference Architecture model which is widely adopted by the utility industry is now insufficient to protect the power grid against cyber-attacks. There is a need to identify what cybersecurity model is effective on Energy Management System (EMS), Advanced Distribution Management System (ADMS), and DER Management System (DERMS) to address the fundamental cybersecurity challenges in the age of increasing renewable energy and DER share as well as consumer participation in the electric energy industry. The next generation of cybersecurity model for OT network should be able to detect inside attackers, mitigate the cybersecurity risks arising from the new grid participants including DER aggregators, electric vehicle owners, and behind-the-meter consumers outside the utility company, and develop the strategy to trust consumer measurement data. This panel will discuss the challenges and pathways for the development of an ensemble cybersecurity model based on predictive state estimation to detect cybersecurity anomalies in OT network including EMS, ADMS, and DERMS.

cybersecurity↗

Development of A Hardware-In-the-Loop (HIL) Testbed for Cyber-Physical Security in Smart Buildings

As smart buildings move towards open communication technologies, providing access to the Building Automation System (BAS) through the building's intranet, or even remotely through the Internet, has become a common practice. However, BAS was historically developed as a closed environment and designed with limited cyber-security considerations. Thus, smart buildings are vulnerable to cyber-attacks with the increased accessibility. This study introduces the development and capability of a Hardware-in-the-Loop (HIT) testbed for testing and evaluating the cyber-physical security of typical BASs in smart buildings. The testbed consists of three subsystems: (1) a real-time HIL emulator simulating the behavior of a virtual building as well as the Heating, Ventilation, and Air Conditioning (HVAC) equipment via a dynamic simulation in Modelica; (2) a set of real HVAC controllers monitoring the virtual building operation and providing local control signals to control HVAC equipment in the HIL emulator; and (3) a BAS server along with a web-based service for users to fully access the schedule, setpoints, trends, alarms, and other control functions of the HVAC controllers remotely through the BACnet network. The server generates rule-based setpoints to local HVAC controllers. Based on these three subsystems, the HIL testbed supports attack/fault-free and attack/fault-injection experiments at various levels of the building system. The resulting test data can be used to inform the building community and support the cyber-physical security technology transfer to the building industry.

Li, Guowen↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Robust and cybersecure coordinated unintentional island detection for microgrids

Unintentional islanding (UI) of a circuit of distributed energy resources (DERs) may leave area electrical power systems (EPS), external to the DER circuit, energized. Thus, UI detection methods have been developed to detect unintentional islanding and trigger a UI response. However, individual UI detection methods have various deficiencies. Thus, a consensus-based UI detection process is disclosed that builds a consensus from multiple UI detection sources, optionally implementing different UI detection methods. The redundancy in this consensus-based UI detection process provides robust, sensitive, selective, and cybersecure UI detection for the entire DER circuit. For example, the consensus-based UI detection process may eliminate or reduce non-detection zones, avoid false positives, thwart cyber-attacks, and/or the like.

Brissette, Alex↗

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Software defined networking moving target defense honeypot

Disclosed herein are systems, methods, and storage media for thwarting cyber-attacks and data theft. A computing system receives packets and compares with a configuration resource. The computing system determines that the packet does not match the configuration resource and transmits a packet to a decoy environment via an SDN switch. The decoy environment is configured to generate time-out, service unavailable, or restricted access messages. In some embodiments, the computing system determines the packet does match the configuration and transmits the packet to a production network via an SDN switch. The SDN switch is communicatively connected to the decoy environment through a first channel and communicatively connected to a production environment through a separate second channel. The computing system is further configured to create and transmit to the SDN switch, rules to manage transmitting the packet to either the decoy environment or the production environment.

Lyle, Joshua A.↗

Internship Presentation: Integrating Safety and Cybersecurity: Security-by-Design with SOWT Analysis for Reactor Testing

This study covers leveraging reactor testing facilities that are primarily designed with a focus on safety to enhance cybersecurity testing. By incorporating reactor security-by-design with reactor safety-by-design principles and adopting defense-in-depth strategies that emphasize both safety and security, the research evaluates applicable cyber tools, models, and solutions. This includes simulating specific cyber-attack scenarios using reactor simulators and performing SWOT (Strengths, Weaknesses, Opportunities, Threats) analysis to improve the cybersecurity of reactor systems.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Smart Inverters, Dumb Risk: Taking Control of IBR Security in the Digital Age

This presentation addresses the security challenges posed by Inverter-Based Resources (IBRs) in the modern energy landscape. The presentation highlights the vulnerabilities and risks associated with IBRs, including the potential for cyber-attacks, the impact of insecure defaults, and the systemic risks posed by supply chain dependencies. Key topics covered include: 1) The increasing digital transformation in energy systems and the associated security risks. 2) Specific vulnerabilities in IBRs, including weak passwords, hardcoded credentials, and insecure web application interfaces. 3) The implications of persistent connectivity and the strategic risks posed by foreign-manufactured components. 4) The role of regulatory frameworks, such as NERC CIP, in addressing these challenges and the limitations of current oversight. 5) Practical solutions for mitigating risks, including secure design practices, vendor risk assessments, and the importance of strong passwords and role-based access control. The presentation underscores the necessity of a comprehensive, system-of-systems approach to securing IBRs, emphasizing the need for collaboration across various stakeholders, including operators, developers, and regulators, to ensure the resilience and security of the energy grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyberattacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyberattack scenarios on matrix completion. Realistic cyberattack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Losing Control of Your Linear Network? Try Resilience Theory

Resilience of cyber-physical networks to unexpected failures is a critical need widely recognized across domains. For instance, power grids, telecommunication networks, transportation infrastructures, and water treatment systems have all been subject to disruptive malfunctions and catastrophic cyberattacks. Following such adverse events, we investigate scenarios where a node of a linear network suffers a loss of control authority over some of its actuators. These actuators are not following the controller's commands and are instead producing undesirable outputs. The repercussions of such a loss of control can propagate and destabilize the whole network despite the malfunction occurring at a single node. To assess system vulnerability, we establish resilience conditions for networks with a subsystem enduring a loss of control authority over some of its actuators. Furthermore, we quantify the destabilizing impact on the overall network when such a malfunction perturbs a nonresilient subsystem. We illustrate our resilience conditions on two academic examples, on an islanded microgrid and on the linearized IEEE 39-bus system.

97 MATHEMATICS AND COMPUTING↗

Machine Learning Based Resilience Testing of an Address Randomization Cyber Defense

Moving target defenses (MTDs) are widely used as an active defense strategy for thwarting cyberattacks on cyber-physical systems by increasing diversity of software and network paths. Recently, machine Learning (ML) and deep Learning (DL) models have been demonstrated to defeat some of the cyber defenses by learning attack detection patterns and defense strategies. It raises concerns about the susceptibility of MTD to ML and DL methods. Here, in this article, we analyze the effectiveness of ML and DL models when it comes to deciphering MTD methods and ultimately evade MTD-based protections in real-time systems. Specifically, we consider a MTD algorithm that periodically randomizes address assignments within the MIL-STD-1553 protocol—a military standard serial data bus. Two ML and DL-based tasks are performed on MIL-STD-1553 protocol to measure the effectiveness of the learning models in deciphering the MTD algorithm: 1) determining whether there is an address assignments change i.e., whether the given system employs a MTD protocol and if it does 2) predicting the future address assignments. The supervised learning models (random forest and k-nearest neighbors) effectively detected the address assignment changes and classified whether the given system is equipped with a specified MTD protocol. On the other hand, the unsupervised learning model (K-means) was significantly less effective. The DL model (long short-term memory) was able to predict the future addresses with varied effectiveness based on MTD algorithm's settings.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Analyzing the Effects of Cyberattacks on Distribution System State Estimation: Preprint

Key components of power systems—such as energy management systems, automatic generation control, and state estimation—are under serious vulnerability from cyber attacks. Cyber threats in electric grids have increased significantly because of the increased interconnectivity of supervisory control and data acquisition systems and public network infrastructure. As the penetration level of distributed energy resources increases, it is imperative to employ system-monitoring techniques such as state estimation for the reliable operation of distribution systems. Recently, multiple methods have been developed that exploit the low rank property of distribution system state matrix and are robust to bad data, such as matrix completion. This paper analyzes the impact of various realistic cyber attack scenarios on matrix completion. Realistic cyber attack scenarios are converted into data corruption models that are used in an extensive simulation of a custom IEEE 123-bus system.

41 EE - Solar Energy Technologies Office (EE-4S)↗