Search NASA⌕ Search

SEARCH · Search NASA

Results for “dark matter detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Exploring the Potential of Residual Impurities in Germanium Detectors for MeV-Scale Dark Matter Detection

Abstract The direct detection of MeV-scale dark matter (DM) particles hinges on achieving an exceptionally low-energy detection threshold. Germanium (Ge) detectors, meticulously tailored with precise impurity compositions, hold the potential to enhance sensitivity to energy levels below the sub-electronvolt (sub-eV) range. This study explores the behavior of residual impurities inherent to Ge detectors at helium temperatures, unveiling a captivating freeze-out phenomenon leading to the formation of excited localized states known as dipole states. Using compelling evidence from relative capacitance measurements obtained from two detectors, we elucidate the transition of impurity atoms from free charge states to these dipole states as the temperature drops from 11 to 6.5 K. Our investigation comprehensively covers the intricate formation of these dipole states in bothn-type andp-type impurities. Furthermore, we shed light on the electric field generated by these dipole states, revealing their ability to trap charges and facilitate the creation of cluster dipole states. Confirming findings from previous measurements, we establish that these excited dipole states exhibit a binding energy of less than 10 meV, offering an exceptionally low detection threshold for MeV-scale DM. Building upon this concept, we propose the development of a 1-kg Ge detector with internal charge amplification—an innovative approach poised to surpass electrical noise and enable the detection of MeV-scale DM with unprecedented sensitivity.

Physics↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV Detector

We present constraints on low mass dark matter-electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of $6.1\,\mathrm{g\cdot days}$ of exposure produces exclusion limits for dark matter-electron scattering cross-sections for masses as low as $1\,\mathrm{MeV}/c^2$, as well as on the photon-dark photon mixing parameter and the coupling constant between axion-like particles and electrons for particles with masses $>1.2\,\mathrm{eV}/c^2$ probed via absorption processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for detecting heavy WIMP dark matter with the Cherenkov Telescope Array: The Wino and Higgsino

TeV-scale particles that couple to the standard model through the weak force represent a compelling class of dark matter candidates. The search for such weakly interacting massive particles has already spanned multiple decades, and whilst it has yet to provide any definitive evidence for their existence, viable parameter space remains. In this paper, we show that the upcoming Cherenkov Telescope Array (CTA) has significant sensitivity to uncharted parameter space at the TeV mass scale. To do so, we focus on two prototypical dark matter candidates, the Wino and Higgsino. Additionally, sensitivity forecasts for both models are performed including the irreducible background from misidentified cosmic rays, as well as a range of estimates for the Galactic emissions at TeV energies. For each candidate, we find substantial expected improvements over existing bounds from current imaging atmospheric Cherenkov telescopes. In detail, for the Wino we find a sensitivity improvement of roughly an order of magnitude in <σ v>, whereas for the Higgsino we demonstrate that CTA has the potential to become the first experiment that has sensitivity to the thermal candidate. Taken together, these enhanced sensitivities demonstrate the discovery potential for dark matter at CTA in the 1–100 TeV mass range.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of planar P-type point contact germanium detectors for low-mass dark matter searches

The detection of low-energy deposition in the range of sub-eV through ionization using germanium (Ge) with a bandgap of ~ 0.7 eV requires internal amplification of the charge signal. This can be achieved through high electric field that accelerates charge carriers, which can then generate more charge carriers. The minimum electric field required to generate internal charge amplification is derived for different temperatures. We report the development of a planar point contact Ge detector in terms of its fabrication and the measurements of its leakage current and capacitance as a function of applied bias voltage. With the determination of the measured depletion voltage, the field distribution is calculated using GeFiCa, which predicts that the required electric field for internal charge amplification can be achieved in proximity to the point contact. The energy response to an Am-241 source is characterized and discussed. We conclude that such a detector with internal charge amplification can be used to search for low-mass dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for low-mass electron-recoil dark matter using a single-charge sensitive SuperCDMS-HVeV detector

We present constraints on low-mass dark matter electron scattering and absorption interactions using a SuperCDMS high-voltage eV-resolution (HVeV) detector. Data were taken underground in the NEXUS facility located at Fermilab with an overburden of 225 meters of water equivalent. The experiment benefits from the minimizing of luminescence from the printed circuit boards in the detector holder used in all previous HVeV studies. A blind analysis of 6.1 g · days of exposure produces exclusion limits for dark matter-electron scattering cross sections for masses as low as 1 MeV/𝑐 2 , as well as on the photon-dark photon mixing parameter and the coupling constant between axionlike particles and electrons for particles with masses >1.2 eV/𝑐 2 probed via absorption processes.

dark matter direct detection↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Proper time observables of general gravitational perturbations in laser interferometry-based gravitational wave detectors

We present an explicitly gauge-invariant observable of any general gravitational perturbation, ℎ 𝜇⁢𝜈 [not necessarily due to gravitational waves (GWs)], in a laser interferometry-based GW detector, identifying the signature as the proper time elapsed of the beamsplitter observer, between two events: when a photon passes through the beamsplitter, and when the same photon returns to the beamsplitter after traveling through the interferometer arm and reflecting off the far mirror. Our formalism applies to simple Michelson interferometers and can be generalized to more advanced setups. We demonstrate that the proper time observable for a plane GW is equivalent to the detector strain commonly used by the GW community, though now the common framework can be easily generalized for other types of signals, such as dark matter clumps or spacetime fluctuations from quantum gravity. We provide a simple recipe for computing the proper time observable for a general metric perturbation in linearized gravity and explicitly show that it is invariant under diffeomorphisms of the perturbation, as any physical observable should be.

Dark matter detectors↗

Development of High-QE GaN Photodectors for Liquid Noble Particle Detectors

Detection of the handful of photons generated when a dark matter particle interacts in a liquid Xenon detector requires a new type of photodetector with very high detection efficiency at ultraviolet wavelengths, very low radioactive backgrounds, and essentially no measureable readout noise (achieved with devices with high intrisic gain). Such devices would find wide applicability to not only high energy physics experiments, but to a number of commercial applications including, e.g., biomedical imaging of fluorescent tags. We developed photodetectors based on amorphous GaN thin film structures (photocathodes) grown by molecular beam epitaxy on quartz windows. We also developed approaches to integrate these photocathode device structures with vacuum electron multipliers. All materials and fabrication techniques were developed to minimize radioactive backgrounds in materials, so these detectors could be used for very low count rate experiments, such as the future liquid-Xenon dark matter detectors, and future liquid-Argon neutrino detectors. We demonstrated growth of very high quantum efficiency amorphous GaN cathodes grown on a number of different substrates (Stainless steel, p-Silicon) reaching detection efficiencies of 80% at 220nm. The key to this growth was to use nitrogen plasma-assistend MBEs and very low growth temperatures. We also discovered that thinner structures (e.g.,40nm a-GaN thin films) had the best performance. We successfully demonstrated techniques for the vacuum transfer of these photocathode structures to a novel chamber that used hydraulics and bellow to form a cold indium bond needed to integrate these cathodes into sealed-tube devices. A complete, stand-along, device could not be completed during this proposal period due to difficulties in growing structures on the thick quartz window. Subsequent work is aimed at addressing this difficulty, by growing a buffer layer on the quartz substrate.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling the differential rate for signal interactions in coincidence with noise fluctuations or large rate backgrounds

The characteristic energy of a relic dark matter interaction with a detector scales strongly with the putative dark matter mass. Consequently, experimental search sensitivity at the lightest masses will always come from interactions whose size is similar to noise fluctuations and low energy backgrounds in the detector. In this paper, we correctly calculate the net change in measured differential event rate due to low rate signal interactions that overlap in time with noise and backgrounds, accounting for both periods of time when the signal is coincident with noise/backgrounds and for the decreased amount of time in which only noise/backgrounds occur and we show that the introduction of random simulated signal events into the continuous raw data stream (a form of “salting”) provides a correct and practical implementation to estimate this net linear signal sensitivity. Unfortunately this does not apply to the situation with non negligible pileups as we show through explicit examples. Consequently, this exclusion technique should be complemented by less sensitive techniques that can separately exclude large rate, high pileup signal parameter space. An analysis threshold above the Gaussian-like noise component of the measured differential rate spectrum should also likely produce conservative limits. Though previous light mass dark matter searches did not correctly account for decreased background only live time effects in their signal sensitivity, conservative analysis choices likely protected their published limits from being nonconservative.

Li, Xinran↗

Search for dark matter in association with an energetic photon in pp collisions at $ \sqrt{s} $ = 13 TeV with the ATLAS detector

A search for dark matter is conducted in final states containing a photon and missing transverse momentum in proton-proton collisions at s√ = 13 TeV. The data, collected during 2015–2018 by the ATLAS experiment at the CERN LHC, correspond to an integrated luminosity of 139 fb -1 . No deviations from the predictions of the Standard Model are observed and 95% confidence-level upper limits between 2.45 fb and 0.5 fb are set on the visible cross section for contributions from physics beyond the Standard Model, in different ranges of the missing transverse momentum. The results are interpreted as 95% confidence-level limits in models where weakly interacting dark-matter candidates are pair-produced via an s-channel axial-vector or vector mediator. Dark-matter candidates with masses up to 415 (580) GeV are excluded for axial-vector (vector) mediators, while the maximum excluded mass of the mediator is 1460 (1470) GeV. In addition, the results are expressed in terms of 95% confidence-level limits on the parameters of a model with an axion-like particle produced in association with a photon, and are used to constrain the coupling g a Z γ of an axion-like particle to the electroweak gauge bosons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for axion dark matter with array-scalable single magnon detectors

We introduce an array-scalable, magnon-based detector to search for the spin-dependent interactions of electron-coupled axion dark matter with mass in the 1−100 μ⁢eV range. These axions can excite single magnons in magnetic targets, such as yttrium iron garnet (YIG) spheres, which are subsequently sensed by the detector. In our concept, this sensing is implemented by coupling the magnons in the YIG spheres to magnetic-field-resilient single-electron charge-qubits, whose state is then interrogated with a quantum nondemolition measurement. Using standard superconducting fabrication techniques, it is possible to integrate many YIG sphere-qubit sensors, forming a large detector array. We outline the detector design and operation for our concept, and determine its sensitivity to axion dark matter. We find that using available technology can already exceed the sensitivity of previous ferromagnetic haloscopes, and further improvements in performance would search for electron-coupled axion dark matter in unexplored parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dark matter catalyzed baryon destruction

WIMP-type dark matter may have additional interactions that break baryon number, leading to induced nucleon decays which are subject to direct experimental constraints from proton decay experiments. In this work, we analyze the possibility of continuous baryon destruction, deriving strong limits from the dark matter accumulating inside old neutron stars, as such a process leads to excess heat generation. We construct the simplest particle dark matter model that breaks the baryon and lepton numbers separately but conserves B - L. Virtual exchange by DM particles in this model results in dinucleon decay via nn → $n\overline{v}$ and np → ne⁺ processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark matter raining on DUNE and other large volume detectors

Direct detection is a powerful means of searching for particle physics evidence of dark matter (DM) heavier than about a GeV with o(kiloton) volume, low-threshold detectors. In many scenarios, some fraction of the DM may be boosted to large velocities enhancing and generally modifying possible detection signatures. We investigate the scenario where 100% of the DM is boosted at the Earth due to new attractive long-range forces. This leads to two main improvements in detection capabilities: (1) the large boost allows for detectable signatures of DM well below a GeV at large-volume neutrino detectors, such as DUNE, Super-K, Hyper-K, and JUNO, as possible DM detectors, and (2) the flux at the Earth’s surface is enhanced by a focusing effect. In addition, the model leads to a significant anisotropy in the signal with the DM flowing dominantly vertically at the Earth’s surface instead of the typical approximately isotropic DM signal. We develop the theory behind this model and also calculate realistic constraints using a detailed GENIE simulation of the signal inside detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗