Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer for SIRTF (MIPS) is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 micron spectral region. It will use high performance photoconductive detectors from 3 to 200 micron with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

MIPS - The Multiband Imaging Photometer for SIRTF

The Multiband Imaging Photometer System (MIPS) for SIRTF is to be designed to reach as closely as possible the fundamental sensitivity and angular resolution limits for SIRTF over the 3 to 700 microns spectral region. It will use high performance photoconductive detectors from 3 to 200 microns with integrating JFET amplifiers. From 200 to 700 microns, the MIPS will use a bolometer cooled by an adiabatic demagnetization refrigerator. Over much of its operating range, the MIPS will make possible observations at and beyond the conventional Rayleigh diffraction limit of angular resolution.

Rieke, G. H.↗

High resolution Doppler lidar

A high resolution lidar system was implemented to measure winds in the lower atmosphere. The wind speed along the line of sight was determined by measuring the Doppler shift of the aerosol backscattered laser signal. The system in its present configuration is stable, and behaves as indicated by theoretical simulations. This system was built to demonstrate the capabilities of the detector system as a prototype for a spaceborne lidar. The detector system investigated consisted of a plane Fabry-Perot etalon, and a 12-ring anode detector. This system is generically similar to the Fabry-Perot interferometer developed for passive wind measurements on board the Dynamics Explorer satellite. That this detector system performs well in a lidar configuration was demonstrated.

Abreu, Vincent J.↗

Fundamental limits to performance of quantum well infrared detectors

Radiometric, density of states (material), and thermal considerations are used to obtain the figure of merit of the quantum-well GaAs/GaAlAs infrared detectors described by Smith et. al. The results are compared with HgCdTe, the present industry standard, as well as with recent experiments at other laboratories.

Yariv, Amnon↗

Variable Temperature Performance of a Si(Li) Detector Stack

New experimental data is presented which displays 137Cs resolution of both single Si(Li) devices and a detector stack 2 cm in height as a function of temperature (85 K greater than or equal to T greater than or equal to 245 K). We also discuss variations in photopeak shape which indicate that detector charge collection may be temperature dependent over the range of interest.

Hubbard, G. Scott↗

A Low-Resolution Unchopped Radiometer for Satellites

The blackbody temperature and the albedo of a planet, and the variation of both parameters with latitude, longitude, and time, are of great value in understanding the climatic and meteorological conditions of the planet. An unchopped radiometer with a wide but restricted field of view is capable of such temperature and albedo measurements. Coated thermistors mounted in highly reflective cones serve as detectors. Their performance as sensor elements is analyzed in detail herein to prove the feasibility of the measurement. The simplicity of the instrumentation and the low information bandwidth required make the experiment equally attractive for earth satellites and space probes.

Hanel, R. A.↗

Survey of Fire Detection Technologies and System Evaluation/Certification Methodologies and Their Suitability for Aircraft Cargo Compartments

As part of the National Aeronautics and Space Administration (NASA) initiated program on global civil aviation, NIST is assisting Federal Aviation Administration in its research to improve fire detection in aircraft cargo compartments. Aircraft cargo compartment detection certification methods have been reviewed. The Fire Emulator-Detector Evaluator (FE/DE) has been designed to evaluate fire detection technologies such as new sensors, multi-element detectors, and detectors that employ complex algorithms. The FE/DE is a flow tunnel that can reproduce velocity, temperature, smoke, and Combustion gas levels to which a detector might be exposed during a fire. A scientific literature survey and patent search have been conducted relating to existing and emerging fire detection technologies, and the potential use of new fire detection strategies in cargo compartment areas has been assessed. In the near term, improved detector signal processing and multi-sensor detectors based on combinations of smoke measurements, combustion gases and temperature are envisioned as significantly impacting detector system performance.

Cleary, T.↗

Generation and Performance of Automated Jarosite Mineral Detectors for Vis/NIR Spectrometers at Mars

Sulfate salt discoveries at the Eagle and Endurance craters in Meridiani Planum by the Mars Exploration Rover Opportunity have proven mineralogically the existence and involvement of water in Mars past. Visible and near infrared spectrometers like the Mars Express OMEGA, the Mars Reconnaissance Orbiter CRISM and the 2009 Mars Science Laboratory Rover cameras are powerful tools for the identification of water-bearing salts and other high priority minerals at Mars. The increasing spectral resolution and rover mission lifetimes represented by these missions currently necessitate data compression in order to ease downlink restrictions. On board data processing techniques can be used to guide the selection, measurement and return of scientifically important data from relevant targets, thus easing bandwidth stress and increasing scientific return. We have developed an automated support vector machine (SVM) detector operating in the visible/near-infrared (VisNIR, 300-2500 nm) spectral range trained to recognize the mineral jarosite (typically KFe3(SO4)2(OH)6), positively identified by the Mossbauer spectrometer at Meridiani Planum. Additional information is included in the original extended abstract.

Gilmore, M. S.↗

Astrophysics to z approx. 10 with Gravitational Waves

The most useful characterization of a gravitational wave detector's performance is the accuracy with which astrophysical parameters of potential gravitational wave sources can be estimated. One of the most important source types for the Laser Interferometer Space Antenna (LISA) is inspiraling binaries of black holes. LISA can measure mass and spin to better than 1% for a wide range of masses, even out to high redshifts. The most difficult parameter to estimate accurately is almost always luminosity distance. Nonetheless, LISA can measure luminosity distance of intermediate-mass black hole binary systems (total mass approx.10(exp 4) solar mass) out to z approx.10 with distance accuracies approaching 25% in many cases. With this performance, LISA will be able to follow the merger history of black holes from the earliest mergers of proto-galaxies to the present. LISA's performance as a function of mass from 1 to 10(exp 7) solar mass and of redshift out to z approx. 30 will be described. The re-formulation of LISA's science requirements based on an instrument sensitivity model and parameter estimation will be described.

Stebbins, Robin↗

X-Ray Spectroscopy Using Low Temperature Detectors

After several decades of development, a significant amount of the effort in low temperature detectors (LTDs) is concentrated on deploying real-world experiments. This has resulted from a great deal of basic detector physics performed by several generations of students, post-docs, and researchers. One of the most fruitful applications of LTDs is in non-dispersive x-ray spectroscopy. LTD x-ray spectrometers are broadband, efficient, moderately high-resolution, and can handle moderately high count rates. However, they require significantly more power, mass, and infrastructure compared to traditional solid state x-ray spectrometers, and cannot achieve, at least at low energies, the resolving powers achieved with dispersive spectrometers. In several fields, however, LTDs have or will make a significant contribution. In this review, we will discuss x-ray spectroscopy in general, the fields of science where LTDs are making a significant impact, and some of the current and near-term LTD spectrometers.

Porter, Frederick↗

Performance and Calibration of H2RG Detectors and SIDECAR ASICs for the RATIR Camera

The Reionization And Transient Infra-Red (RATIR) camera has been built for rapid Gamma-Ray Burst (GRE) followup and will provide simultaneous optical and infrared photometric capabilities. The infrared portion of this camera incorporates two Teledyne HgCdTe HAWAII-2RG detectors, controlled by Teledyne's SIDECAR ASICs. While other ground-based systems have used the SIDECAR before, this system also utilizes Teledyne's JADE2 interface card and IDE development environment. Together, this setup comprises Teledyne's Development Kit, which is a bundled solution that can be efficiently integrated into future ground-based systems. In this presentation, we characterize the system's read noise, dark current, and conversion gain.

Fox, Ori D.↗

Method and Apparatus for Measuring Near-Angle Scattering of Mirror Coatings

Disclosed herein is a method of determining the near angle scattering of a sample reflective surface comprising the steps of: a) splitting a beam of light having a coherence length of greater than or equal to about 2 meters into a sample beam and a reference beam; b) frequency shifting both the sample beam and the reference beam to produce a fixed beat frequency between the sample beam and the reference beam; c) directing the sample beam through a focusing lens and onto the sample reflective surface, d) reflecting the sample beam from the sample reflective surface through a detection restriction disposed on a movable stage; e) recombining the sample beam with the reference beam to form a recombined beam, followed by f) directing the recombined beam to a detector and performing heterodyne analysis on the recombined beam to measure the near-angle scattering of the sample reflective surface, wherein the position of the detection restriction relative to the sample beam is varied to occlude at least a portion of the sample beam to measure the near-angle scattering of the sample reflective surface. An apparatus according to the above method is also disclosed.

Chipman, Russell A.↗

Preliminary On-Orbit Neutron Dose Equivalent and Energy Spectrum Results from the ISS-RAD Fast Neutron Detector (FND)

The ISS-RAD instrument was activated on ISS on February 1st, 2016. Integrated in ISS-RAD, the Fast Neutron Detector (FND) performs, for the first time on ISS, routine and precise direct neutron measurements between 0.5 and 8 MeV. Preliminary results for neutron dose equivalent and neutron flux energy distributions from online/on-board algorithms and offline ground analyses will be shown, along with comparisons to simulated data and previously measured neutron spectral data. On-orbit data quality and pre-launch analysis validation results will be discussed as well.

Semones, Edward↗

Suomi NPP VIIRS DNB and RSB M Bands Detector-To-Detector and HAM Side Calibration Differences Assessment Using a Homogenous Ground Target

Near-nadir observations of the Libya 4 site from the S-NPP VIIRS Day-Night Band (DNB) and Moderate resolution Bands (M bands) are used to assess the detector calibration stability and half-angle mirror (HAM) side differences. Almost seven years of Sensor Data Records products are extracted from the Libya 4 site center over an area of 32×32 pixels. The mean values of the radiance from individual detectors per HAM side are computed separately. The comparison of the normalized radiance between detectors indicates that the detector calibration differences are wavelength dependent and the differences have been slowly increasing with time for short wavelength bands, especially for M1-M4. The maximum annual average differences between DNB detectors are 0.77% in 2017 at HAM-A. For the M bands, the maximum detector differences in 2017 are 1.7% for M1, 1.8% for M2, 1.3% for M3, 1.2% for M4, 0.67% for M5, 0.75% for M7, 0.57% for M8, 13% for M9, 0.63% for M10, and 0.66% for M11. The average HAM side A to B difference in 2017 are 0.00% for DNB, 0.22% for M1, 0.17% for M2, 0.15% for M3, 0.09% for M4, -0.07% for M5, 0.02% for M7, 0.01% for M8, 1.4% for M9, 0.01% for M10, and 0.03% for M11. Results for M6 are not available due to the signal saturation and M9 results are not accurate because of the low reflectance from the desert site and the strong atmospheric absorption in this channel. The results in this study help scientists better understand each detector’s performance and HAM side characteristics. Additionally, they provide evidence and motivation for future VIIRS calibration improvements.

SNPP VIIRS↗

Evaluation of a far infrared Ge:Ga multiplexed detector array

The performance of a multielement Ge:Ga linear array under low-background conditions is investigated. On-focal plane switching is accomplished by MOSFET switches and the integrated charge is made available through MOSFET source followers. The tests were conducted at 106 microns and the radiation on the detectors was confined to a spectral window 1.25 microns wide using a stack of cold filters. At 4.2 K, the responsivity was measured to be nominally 584 A/W, and the NEP was 1.0 x 10 exp -16 W/sq rt Hz. A detailed description of the test setup and the procedure is presented.

Farhoomand, Jam↗

Comparison of Thermal Coefficients for Two Microwave Detectors

Laboratory measurements were performed to compare the thermal coefficients of two microwave detectors that might be used for direct detection in L-band radiometers. In particular it was desired to compare the performance of a new-technology flash ADC (analog-to-digital converter) against that of an older-technology diode detector in series with a VFC (voltage-to-frequency converter). The outputs of two state-of-the-art detectors were recorded as a constant 1.414-GHz signal was input and the physical temperatures of the detectors were varied over a range of 10 C. As a further experiment, each detector was tested with a noise diode source and with a sine wave synthesizer source. Thermal coefficients were computed in terms of W/C and in terms of ppt/C at nominal operating temperatures reasonable for the individual devices. Finally, thermal coefficients were calculated in K/C to indicate the change in brightness temperature seen by a theoretical sea surface salinity radiometer employing each detector. The K/C for the flash ADC was determined to be about 2.8 times that of the diode/VFC. Different reactions of the ADC to a noise input and a sine wave input indicated that ADC tests for radiometric purposes, such as this one, should be performed using a noise input.

Mackenzie, Anne I.↗

Performance of room temperature mercuric iodide /HgI2/ detectors in the ultralow-energy X-ray region

Experiments have been done to study the performance of mercuric iodide (HgI2) detectors in the ultralow-energy X-ray region. Energy resolution values of 245 eV (FWHM) for the Mg K-alpha X-ray line at 1.25 keV and 225 eV (FWHM) for the electronic noise linewidth have been obtained for an HgI2 detector with painted carbon contacts using a pulsed-light feedback preamplifier; the whole system was operated at room temperature. The resolution values in the ultralow-energy region are still limited by electronic noise of the system. In an attempt to minimize X-ray attenuation in the front contact, detectors were prepared with thin evaporated Pd contacts. These detectors show a pronounced low-energy tailing of the photopeak below a few keV, in contrast to the spectra obtained by detectors with carbon contact. An attempt has been made to explain the tailing effect starting with models wich have been proposed to describe similar effects in Ge detectors.

Dabrowski, A. J.↗

HgCdTe for NASA EOS missions and detector uniformity benchmarks

Important NASA Earth Observing System (EOS) missions, Atmospheric Infrared Sounder (AIRS) and Moderate Resolution Imaging Spectrometer (MODIS-N), which require detector spectral response in the range of 14 to 17 microns at medium background flux levels and operation in the range of temperatures between 65 to 95 K, will be flown beginning in the next few years. Currently, a prime candidate detector technology for these missions is trapping-mode photoconductive HgCdTe devices. These devices can be tailored to the exact cutoff wavelengths required by those missions, and thus offer the performance advantages of an intrinsic detector which is ideally matched to the mission wavelength. Under the long wavelength-background-temperature conditions of these EOS missions, any detector will at best be thermal generation-recombination noise limited. Photoconductive devices are generally preferred under these circumstances, since at elevated temperatures their performance degrades with n(sub i) while for photovoltaic detectors performance degrades as n sub i(exp 2) n sub i is the intrinsic carrier concentration which is a function of alloy composition and temperature, but not doping. Very high performance trapping-mode photoconductive HgCdTe detectors have been developed which can be reproducibly fabricated. Detectivity (D asterisk) at 80K and 16 micron cutoff wavelength in excess of 10(exp 11) Jones has been measured for these devices. Power dissipation is at least two orders of magnitude less than conventional HgCdTe photoconductors - on the order of 0.12 W/cm(exp 2) compared with 12 W/cm(exp 2). EOS missions define thermal noise limited conditions for the long wavelength operating bands. Trapping-mode photoconductive HgCdTe detectors are linear under such conditions and responsivity is independent of background flux. At lower temperatures or high flux conditions in which background flux limits detector performance, trapping-mode detectors have a responsivity which varies with background flux. Internal calibration must be provided for radiometric measurements under the latter conditions (not an EOS mission concern). Liquid phase epitaxy is used to grow these HgCdTe device structures. This technique has been shown to give control of the cutoff wavelength on the order of 16 plus or minus 1 micron or less, both from run to run and across wafer dimensions of several centimeters on a side.

Norton, Paul R.↗