Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The solution of linear systems of equations with a structural analysis code on the NAS CRAY-2

Two methods for solving linear systems of equations on the NAS Cray-2 are described. One is a direct method; the other is an iterative method. Both methods exploit the architecture of the Cray-2, particularly the vectorization, and are aimed at structural analysis applications. To demonstrate and evaluate the methods, they were installed in a finite element structural analysis code denoted the Computational Structural Mechanics (CSM) Testbed. A description of the techniques used to integrate the two solvers into the Testbed is given. Storage schemes, memory requirements, operation counts, and reformatting procedures are discussed. Finally, results from the new methods are compared with results from the initial Testbed sparse Choleski equation solver for three structural analysis problems. The new direct solvers described achieve the highest computational rates of the methods compared. The new iterative methods are not able to achieve as high computation rates as the vectorized direct solvers but are best for well conditioned problems which require fewer iterations to converge to the solution.

Poole, Eugene L.↗

High Spectral Resolution, High Cadence, Imaging X-Ray Microcalorimeters for Solar Physics

High spectral resolution, high cadence, imaging x-ray spectroscopy has the potential to revolutionize the study of the solar corona. To that end we have been developing transition-edge-sensor (TES) based x-ray micro calorimeter arrays for future solar physics missions where imaging and high energy resolution spectroscopy will enable previously impossible studies of the dynamics and energetics of the solar corona. The characteristics of these x-ray microcalorimeters are significantly different from conventional micro calorimeters developed for astrophysics because they need to accommodate much higher count rates (300-1000 cps) while maintaining high energy resolution of less than 4 eV FWHM in the X-ray energy band of 0.2-10 keV. The other main difference is a smaller pixel size (less than 75 x 75 square microns) than is typical for x-ray micro calorimeters in order to provide angular resolution less than 1 arcsecond. We have achieved at energy resolution of 2.15 eV at 6 keV in a pixel with a 12 x 12 square micron TES sensor and 34 x 34 x 9.1 micron gold absorber, and a resolution of 2.30 eV at 6 keV in a pixel with a 35 x 35 micron TES and a 57 x 57 x 9.1 micron gold absorber. This performance has been achieved in pixels that are fabricated directly onto solid substrates, ie. they are not supported by silicon nitride membranes. We present the results from these detectors, the expected performance at high count-rates, and prospects for the use of this technology for future Solar missions.

Bandler, Simon R.↗

Cloud Microphysics in Hurricane Outflows: Observations in 'Bonnie' (1998) at 12 km Altitude

The water balance of a hurricane is controlled by boundary layer inflow, near vertical motion in the eyewall causing coalescence precipitation at above and residual ice precipitation at below freezing temperatures, and cirrus outflow at below -40 C aloft. In this paper we address the question of efficiency of water removal by this cirrus outflow which is important for the release of latent heat at high altitudes and its role in the dynamic flow at that level. During NASA's 1998 Convection and Moisture Experiment campaign we acquired microphysical outflow data in order to (1) determine the release and redistribution of latent heat near the top of hurricanes, (2) aid in TRMM algorithm development for remote sensing of precipitation, and (3) determine the optical/radiative characteristics of hurricane outflow. The data were acquired with Particle Measuring Systems two dimensional imaging spectrometers. On 23 August and again during the hurricane's landfall on 26 August, 1998, the NASA DC-8 aircraft penetrated hurricane 'Bonnie' four times each near 200 hPa pressure altitude. The eye crossing times were determined by (1) zero counts of cloud particles, (2) approximately 5 C increases in static and potential temperatures, and (3) minima in speeds and changes of direction of horizontal winds. The vertical winds showed shear between -6 m per second and +4 m per second and tangential winds approached 30 m per second in the eyewall. The particle volumes in the eyewall (determined by the pixels the particles shadowed in the direction of flight [x-direction] and normally to it by the number of diodes that they shadowed [y-direction]) ranged between 0.5 and 5.0 cubic centimeters per cubic meter. With a particle density near 0.2 g per cubic centimeter (determined from in situ melting and evaporation on a surface collector), the 1.0 g per meter corresponding mass of cloud ice ranged between 0.27 and 2.7 g per kilograms yielding horizontal fluxes between 8.1 and 81 g per square meters per second. The outflow ice was concentrated in crystals of a modal size of 190 micrometers. The particle size distributions were heavily skewed toward sizes with 98% of all cirrus particles smaller than the modal size comprising, however, only 20% of the mass. Thus the smaller than modal size particles dominantly affected the optical/radiative characteristics of the cloud, whereas the larger than modal size crystals determined the ice mass, hence dominated latent heating. Questions to be addressed relate to the origin of individual ice particles as the hurricane evolved and the likelihood of pristine and aggregate particle formation under the complicated conditions of rotation and outflow in the eyewall.

Pueschel, Rudolf F.↗

Cursor Control Device Test Battery

The test battery was developed to provide a standard procedure for cursor control device evaluation. The software was built in Visual Basic and consists of nine tasks and a main menu that integrates the set-up of the tasks. The tasks can be used individually, or in a series defined in the main menu. Task 1, the Unidirectional Pointing Task, tests the speed and accuracy of clicking on targets. Two rectangles with an adjustable width and adjustable center- to-center distance are presented. The task is to click back and forth between the two rectangles. Clicks outside of the rectangles are recorded as errors. Task 2, Multidirectional Pointing Task, measures speed and accuracy of clicking on targets approached from different angles. Twenty-five numbered squares of adjustable width are arranged around an adjustable diameter circle. The task is to point and click on the numbered squares (placed on opposite sides of the circle) in consecutive order. Clicks outside of the squares are recorded as errors. Task 3, Unidirectional (horizontal) Dragging Task, is similar to dragging a file into a folder on a computer desktop. Task 3 requires dragging a square of adjustable width from one rectangle and dropping it into another. The width of each rectangle is adjustable, as well as the distance between the two rectangles. Dropping the square outside of the rectangles is recorded as an error. Task 4, Unidirectional Path Following, is similar to Task 3. The task is to drag a square through a tunnel consisting of two lines. The size of the square and the width of the tunnel are adjustable. If the square touches any of the lines, it is counted as an error and the task is restarted. Task 5, Text Selection, involves clicking on a Start button, and then moving directly to the underlined portion of the displayed text and highlighting it. The pointing distance to the text is adjustable, as well as the to-be-selected font size and the underlined character length. If the selection does not include all of the underlined characters, or includes non-underlined characters, it is recorded as an error. Task 6, Multi-size and Multi-distance Pointing, presents the participant with 24 consecutively numbered buttons of different sizes (63 to 163 pixels), and at different distances (60 to 80 pixels) from the Start button. The task is to click on the Start button, and then move directly to, and click on, each numbered target button in consecutive order. Clicks outside of the target area are errors. Task 7, Standard Interface Elements Task, involves interacting with standard interface elements as instructed in written procedures, including: drop-down menus, sliders, text boxes, radio buttons, and check boxes. Task completion time is recorded. In Task 8, a circular track is presented with a disc in it at the top. Track width and disc size are adjustable. The task is to move the disc with circular motion within the path without touching the boundaries of the track. Time and errors are recorded. Task 9 is a discrete task that allows evaluation of discrete cursor control devices that tab from target to target, such as a castle switch. The task is to follow a predefined path and to click on the yellow targets along the path.

Kritina Holden↗

Optical Array Versus Monolithic Telescope Ground Station Cost Assessment

The purpose of this study is to outline the design of an optimal array of optical telescopes to emulate performance of a monolithic 12 m telescope in support of deep-space communications. In this case, optimal means minimizing the initial capital investment and operational cost while maintaining performance requirements of the deep-space link. The design is approached from a practical, engineering perspective. Pulse position modulation (PPM) signal formatting and photon counting detectors are assumed at each telescope in the array. That is, the telescopes function as so-called light buckets, so direct detection (as opposed to coherent reception) of the received signals is assumed, and there is no intention to consider active compensation for atmospheric turbulence-induced phase fluctuations. A parametric analysis among aperture size, detector size, and primary mirror surface quality, in the context of field-of-view expansion, is presented to minimize the cost function.

Romanofsky, Robert R.↗

ATP as a biomarker of viable microorganisms in clean-room facilities

A new firefly luciferase bioluminescence assay method that differentiates free extracellular ATP (dead cells, etc.) from intracellular ATP (viable microbes) was used to determine the viable microbial cleanliness of various clean-room facilities. For comparison, samples were taken from both clean-rooms, where the air was filtered to remove particles >0.5 microm, and ordinary rooms with unfiltered air. The intracellular ATP was determined after enzymatically degrading the sample's free ATP. Also for comparison, cultivable microbial populations were counted on nutrient-rich trypticase soy agar (TSA) plates. Both the cultivable and ATP-based determinations indicate that the microbial burden was lower in clean-room facilities than in ordinary rooms. However, there was no direct correlation between the two sets of measurements because the two assays measured very different populations. A large fraction of the samples yielded no colony formers on TSA, but were positive for intracellular ATP. Subsequently, genomic DNA was isolated directly from selected samples and 16S rDNA fragments were cloned and sequenced, identifying nearest neighbors, many of which are known to be noncultivable in the media employed. It was concluded that viable microbial contamination can be reliably monitored by measurement of intracellular ATP, and that this method may be considered superior to cultivable colony counts due to its speed and its ability to report the presence of viable but noncultivable organisms. When the detection of nonviable microbes is of interest, the ATP assay can be supplemented with DNA analysis.

NASA Discipline Environmental Health↗

Single-Photon Counting Detector Scalability for High Photon Efficiency Optical Communications Links

For high photon-efficiency deep space or low power optical communications links, such as the Orion Artemis-2 Optical Communications System (O2O) project, the received optical signal is attenuated to the extent that single- photon detectors are required. For direct-detection receivers operating at 1.55 µm wavelength, single-photon detectors including Geiger-mode InGaAs avalanche photon diodes (APDs), and in particular superconducting nanowire single-photon detectors (SNSPDs) offer the highest sensitivity and fastest detection speeds. However, these photon detectors exhibit a recovery time between registered input pulses, effectively reducing the detection efficiency over the recovery interval, resulting in missed photon detections, reduced count rate, and ultimately limiting the achievable data rate. A method to overcome this limitation is to divide the received optical signal into multiple detectors in parallel. Here we analyze this approach for a receiver designed to receive a high photon efficiency serially concatenated pulse position modulation (SCPPM) input waveform. From measured count rate and efficiency data using commercial SNSPDs, we apply a model from which we determine the effective detection efficiency, or blocking loss, for different input signal rates. We analyze the scalability of adding detectors in parallel for different modulation orders and background levels to achieve desired data rates. Finally we show tradeoffs between the number of detectors and the required received optical power, useful for real link design considerations.

Vyhnalek, Brian E.↗

Improved methods for counting bacteria in physiological fluids

Bacterial population detection is based on detection of adenosine triphosphate (ATP), chemical present in all living matter. Amount of ATP in sample, after chemically removing all nonbacterial ATP, is directly related to bacterial population. Sensitivity is improved by concentration step; specificity is improved by lowering pH of solution.

Picciolo, G. L.↗

LANDSAT-4/5 image data quality analysis

A LANDSAT Thematic Mapper (TM) quality evaluation study was conducted to identify geometric and radiometric sensor errors in the post-launch environment. The study began with the launch of LANDSAT-4. Several error conditions were found, including band-to-band misregistration and detector-to detector radiometric calibration errors. Similar analysis was made for the LANDSAT-5 Thematic Mapper and compared with results for LANDSAT-4. Remaining band-to-band misregistration was found to be within tolerances and detector-to-detector calibration errors were not severe. More coherent noise signals were observed in TM-5 than in TM-4, although the amplitude was generally less. The scan direction differences observed in TM-4 were still evident in TM-5. The largest effect was in Band 4 where nearly a one digital count difference was observed. Resolution estimation was carried out using roads in TM-5 for the primary focal plane bands rather than field edges as in TM-4. Estimates using roads gave better resolution. Thermal IR band calibration studies were conducted and new nonlinear calibration procedures were defined for TM-5. The overall conclusion is that there are no first order errors in TM-5 and any remaining problems are second or third order.

Malaret, E.↗

Vortex Core Size in the Rotor Near-Wake

Using a kinetic energy conservation approach, a number of simple analytic expressions are derived for estimating core size of tip vortices in the near-wake of rotors in hover or axial-flight (climb). The influence of thrust, axial-flight advance ratio, blade count, blade aspect ratio, nonuniform disk loading, and vortex structure on rotor vortex core size is assessed. Vortex core size is found to be directly proportional to rotor thrust and inversely proportional to axial-flight advance ratio. Further, it is found that the more efficient the rotor is with respect to factors that affect induced power, the smaller the vortex core size. In particular, uniformity of the rotor disk loading clearly has the greatest influence on vortex core size of the parameters studied in this paper.

Young, Larry A.↗

Infrared Thermography Flight Experimentation

Analysis was done on IR data collected by DFRC on May 8, 2002. This includes the generation of a movie to initially examine the IR flight data. The production of the movie was challenged by the volume of data that needed to be processed, namely 40,500 images with each image (256 x 252) containing over 264 million points (pixel depth 4096). It was also observed during the initial analysis that the RTD surface coating has a different emissivity than the surroundings. This fact added unexpected complexity in obtaining a correlation between RTD data and IR data. A scheme was devised to generate IR data near the RTD location which is not affected by the surface coating This scheme is valid as long as the surface temperature as measured does not change too much over a few pixel distances from the RTD location. After obtaining IR data near the RTD location, it is possible to make a direct comparison with the temperature as measured during the flight after adjusting for the camera s auto scaling. The IR data seems to correlate well to the flight temperature data at three of the four RID locations. The maximum count intensity occurs closely to the maximum temperature as measured during flight. At one location (RTD #3), there is poor correlation and this must be investigated before any further progress is possible. However, with successful comparisons at three locations, it seems there is great potential to be able to find a calibration curve for the data. Moreover, as such it will be possible to measure temperature directly from the IR data in the near future.

Blanchard, Robert C.↗

Infrared upconversion as a means of seeing in the dark

A new approach to seeing in the dark is described which is based on the principles of nonlinear optics employing a crystal such as lithium iodate. A nonlinear optical device capable of producing photons at higher frequencies from lower-frequency incident light is shown to upconvert infrared light directly into visible light. The major advantages of the infrared upconversion process is that it permits the infrared signal to be detected by photon-counting devices presently available for the visible spectral region, and that it can provide sensitivity to infrared radiation without the need for cryogenic cooling of the detector used. Early works on infrared upconversion are reviewed. The development of applications is discussed as to astronomical spectroscopy and infrared image upconversion involving either angular or positional resolution elements. The demonstration of infrared upconversion in rectangular waveguides of single-crystal GaAs by Anderson et al. (1971) indicates future possibilities in upconversion by the use of integrated optics devices.

Gurski, T. R.↗

High Count-Rate Study of Two TES X-Ray Microcalorimeters With Different Transition Temperatures

We have developed transition-edge sensor (TES) microcalorimeter arrays with high count-rate capability and high energy resolution to carry out x-ray imaging spectroscopy observations of various astronomical sources and the Sun. We have studied the dependence of the energy resolution and throughput (fraction of processed pulses) on the count rate for such microcalorimeters with two different transition temperatures T(sub c). Devices with both transition temperatures were fabricated within a single microcalorimeter array directly on top of a solid substrate where the thermal conductance of the microcalorimeter is dependent upon the thermal boundary resistance between the TES sensor and the dielectric substrate beneath. Because the thermal boundary resistance is highly temperature dependent, the two types of device with different T(sub c)(sup s) had very different thermal decay times, approximately one order of magnitude different. In our earlier report, we achieved energy resolutions of 1.6 and 2.eV at 6 keV from lower and higher T(sub c) devices, respectively, using a standard analysis method based on optimal filtering in the low flux limit. We have now measured the same devices at elevated x-ray fluxes ranging from 50 Hz to 1000 Hz per pixel. In the high flux limit, however, the standard optimal filtering scheme nearly breaks down because of x-ray pile-up. To achieve the highest possible energy resolution for a fixed throughput, we have developed an analysis scheme based on the socalled event grade method. Using the new analysis scheme, we achieved 5.0 eV FWHM with 96 Percent throughput for 6 keV x-rays of 1025 Hz per pixel with the higher T(sub c) (faster) device, and 5.8 eV FWHM with 97 Percent throughput with the lower T(sub c) (slower) device at 722 Hz.

Lee, Sang-Jun↗

Water Quality Contamination Sources and Controls for the Exploration Extra-vehicular Mobility Unit (xEMU)

NASA has been developing a new spacesuit, called the Exploration Extravehicular Mobility Unit (xEMU) for over a decade. This spacesuit is underdevelopment to support missions to the International Space Station (ISS) and also to the Moon. The xEMU uses controlled evaporative cooling through a membrane to reject waste heat from the crewmember, avionics, and environmental in-leak during autonomous operation. Given the unique mass and volume constraints imposed by the spacesuit application and the opportunities presented by the selection of a given membrane, the xEMU does not possess a separate feedwater loop to feed the evaporation process, rather the feedwater for the evaporation process is fed directly from the transport loop which collects heat from the sources within the suit. This has many benefits including mass/volume reductions from a lower component count within the system but does pose some additional potential constraints on water quality within the system in order to provide a working fluid that can be pumped, filtered, and used in contact with the remainder of the system while both avoiding fouling of the membrane as well as other deleterious effects such as creating conditions for corrosion of wetted surfaces within the transport loop. The discussion will seek to address the main sources of contamination and the applied controls. Sources considered will include: self-generated via materials selection and processes applied, influent working fluid, contamination of the influent working fluid via Ground Support Equipment (GSE) or processing equipment, microbial activity, and environmental influences such as elevated ambient CO2.

Colin Campbell↗

Particulate and aerosol detector

A device is described for counting aerosols and sorting them according to either size, mass or energy. The component parts are an accelerator, a capacitor sensor and a readout. The accelerator is a means for accelerating the aerosols toward the face of the capacitor sensor with such force that they partially penetrate the capacitor sensor, momentarily discharging it. The readout device is a means for counting the number of discharges of the capacitor sensor and measuring the amplitudes of these different discharges. The aerosols are accelerated by the accelerator in the direction of the metal layer with such force that they penetrate the metal and damage the oxide layers, thereby allowing the electrical charge on the capacitor to discharge through the damaged region. Each incident aerosol initiates a discharge path through the capacitor in such a fashion as to vaporize the conducting path. Once the discharge action is complete, the low resistance path no longer exists between the two capacitor plates and the capacitor is again able to accept a charge. The active area of the capacitor is reduced in size by the damaged area each time a discharge occurs.

Wortman, J. J.↗

Far ultraviolet observations of the expanding shell in Eridanus

After correcting for hot stars in the instrument field of view, 1350-1750 A wavelength band observations of a thin strip of the sky near the south galactic pole have yielded count rates which vary smoothly from a minimum of about 55/cs near l = 30 deg, b = -60 deg to a maximum of about 740/cs in the direction of l = 199 deg, b = -49 deg. These values correspond to specific intensities of 600-8000 photons/sq cm per sec per sr per A, assuming a flat incident spectrum in this wavelength range. The magnitude and spatial variation of the observed signal are incompatible with any known source of terrestrial far-UV airglow, zodiacal light, or with the expected emission of high latitude reflection nebulosities. Attention is given to alternative sources that, together with the reflection nebulae, may explain the high intensities in this region.

Paresce, F.↗

Observational study of ion-electron equilibration and of cloud evaporation in supernova remnants under the HEAO-2 guest investigator program

Observations of three selected supernovae remnants (Cygnus Loop, IC 443, and Puppis A) were made in the forbidden coronal iron lines (Fe X) lambda 6374 and (Fe XIV) lambda 5303. The resulting data was compared quantitatively with Einstein images of the same objects, and an attempt was made to determine (a) the process by which ion and electron energies are equilibrated behind the shock front in the ISM and (b) whether cloud evaporation occurs within the hot remnant interiors. Spatially-resolved X ray emission were modeled for Sedov-Taylor blast wave models of supernovae remnants (SNR) under conditions of non-equlibrium ionization. The computations are intended to provide results that can be directly compared with Einstein high resolution image (HRI) and imaging proportional counter (IPS) data. The computer program for predicting the spatial distribution of HRI and IPS counting rates was completed, and final testing of it had begun.

Teske, R. G.↗

Microbial Diffraction Gratings as Optical Detectors for Heavy Metal Pollutants

As a significant industrial pollutant, cadmium is implicated as the cause of itai-itai disease. For biological detection of cadmium toxicity, an assay device has been developed using the motile response of the protozoa species, Tetrahymena pyriformis. This mobile protozoa measures 50 microns in diameter, swims at 10 body lengths per second, and aggregates into macroscopically visible patterns at high organism concentrations. The assay demonstrates a Cd(+2) sensitivity better than 1 micro-M and a toxicity threshold to 5 micro-M, thus encouraging the study of these microbial cultures as viable pollution detectors. Using two-dimensional diffraction patterns within a Tetrahymena culture, the scattered light intensity varies with different organism densities (population counts). The resulting density profile correlates strongly with the toxic effects at very low dosages for cadmium (less than 5 ppm) and then for poison protection directly (with nickel and copper antagonists competing with cadmium absorption). In particular, copper dosages as low as 0.1-0.5 mM Cu have shown protective antagonism against cadmium, have enhanced density variability for cultures containing 1 mM Cd(+2) and therefore have demonstrated the sensitivity of the optical detection system. In this way, such microbial diffraction patterns give a responsive optical measure of biological culture changes and toxicity determination in aqueous samples of heavy metals and industrial pollutants.

Noever, David↗