Vapor-Phase Aggregation of Cerium Oxide Nanoparticles in a Rapidly Cooling Plasma

Local conditions, such as temperature and oxygen availability, have a pronounced effect on the formation and evolution of fallout following a nuclear explosion. While the behavior of nuclear-relevant materials such as uranium has begun to be explored under a wider range of environments, little is known about the behavior of plutonium. Here, using cerium as a surrogate, we track the vapor-phase aggregation of cerium oxide nanoparticles created in a plasma flow reactor under conditions of controlled temperature at two different oxygen fugacities. In situ optical emission spectroscopy is used to measure the variations in the spectral intensity of atomic and molecular species with temperature and oxygen content. We find that the relative rate of gas-phase oxidation of cerium is highly dependent on both temperature and local redox conditions within the flow reactor, to the extent that doubling the oxygen availability effectively doubles the amount of vapor-phase cerium monoxide at high temperatures (>2000 K). Condensed cerium oxide nanoparticles are also collected and analyzed ex situ via transmission electron microscopy and grazing-incidence small-angle X-ray scattering to determine their elemental composition, crystal structure, and size distribution. The size and morphology of the condensed nanoparticles are independent of local redox conditions, forming the same crystal type with the same size distribution regardless of oxygen availability. Postcondensation particle evolution, however, is found to be predominantly driven by temperature, with the average particle size increasing as particles cool and subsequently aggregate. These results expand our understanding of the chemical and physical behavior of refractory oxides that form during the early stages of fallout formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterizing the X-Ray Emission of Intermediate-mass Pre-main-sequence Stars

We use X-ray and infrared observations to study the properties of three classes of young stars in the Carina Nebula: intermediate-mass (2–5 M {sub ⊙}) pre-main-sequence stars (IMPS; i.e., intermediate-mass T Tauri stars), late-B and A stars on the zero-age main sequence (AB), and lower-mass T Tauri stars (TTS). We divide our sources among these three subclassifications and further identify disk-bearing young stellar objects versus diskless sources with no detectable infrared (IR) excess emission using IR (1–8 μm) spectral energy distribution modeling. We then perform X-ray spectral fitting to determine the hydrogen-absorbing column density (N {sub H}), absorption-corrected X-ray luminosity (L {sub X}), and coronal plasma temperature (kT) for each source. We find that the X-ray spectra of both IMPS and TTS are characterized by similar kT and N {sub H}, and on average L {sub X}/L {sub bol} ~ 4 × 10{sup -4}. IMPS are systematically more luminous in X-rays (by ~0.3 dex) than all other subclassifications, with median L {sub X} = 2.5 × 10{sup 31} erg s{sup -1}, while AB stars of similar masses have X-ray emission consistent with TTS companions. These lines of evidence converge on a magnetocoronal flaring source for IMPS X-ray emission, a scaled-up version of the TTS emission mechanism. IMPS therefore provide powerful probes of isochronal ages for the first ~10 Myr in the evolution of a massive stellar population, because their intrinsic, coronal X-ray emission decays rapidly after they commence evolving along radiative tracks. We suggest that the most luminous (in both X-rays and IR) IMPS could be used to place empirical constraints on the location of the intermediate-mass stellar birth line.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2016 Alabama PV soft cost and workforce development

The Southeastern US has the largest potential for growth in the solar industry. However, currently they languish behind the rest of the US. There are several bright spots including the large number of utility scale installations in North Carolina and the recent successes in South Carolina under Act 236. In order to better understand the impacts of state legislation on the growth of the solar industry in the SE US, the Savannah River National Laboratory has undertaken a study to look at the growth in each state in order to develop recommendations to help reduce the cost of solar and to spur the industry. This is the second report in the series. The first focused on developing cost metrics for South Carolina under Act 236. This report focuses on Alabama, the 49th ranked state for solar business, which has very similar population and median income to South Carolina. For this survey, the ten known in-state installers were contacted. Responses were received from seven, representing 70% of the installers, a majority of which provide both residential and commercial installations. Interestingly, none of the respondents serve the utility scale sector. Overall, costs for Alabama are on track with the rest of the country with a reported average cost of $3.29/W-DC for residential systems and $2.44/W-DC for commercial systems. 60% of this cost is attributed to hardware only. Of the remaining costs, installation contributed to the largest percentage of soft costs followed by overhead, marketing and sales, and permitting, respectively. This also closely mirrors results seen in South Carolina. Job growth in the industry is expected to proceed well. An expected 34-42 additional full time equivalent jobs were expected to be added in Alabama within the six month window following the survey period. During the three years following the survey, this number was expected to double with 89-97 additional jobs being added to the market. In both cases, a vast majority of these jobs were for installation professionals and electricians. Despite the cost of solar, the industry continues to struggle in Alabama, largely due to the absence of any statewide net metering legislation. By current best estimates, there are over 60 residential installations statewide; however, this number is difficult to track due to the lack of a State authority keeping a consolidated list of grid connected distributed power systems. In South Carolina, the Energy Office tracks and reports grid connected distributed power systems by all Cooperatives and utilities. In Alabama, the Energy Office does not fulfill this role and data must be collected directly from each utility and cooperative, which makes collection and analysis difficult. Having a central state agency track this information would be extremely useful towards developing state policy recommendations, particularly if net metering were enabled within the state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Test Beam Results of Planar Pixel Sensor for the CMS Phase 2 Inner Tracker Upgrade

Results of the test beam measurements that characterise the performance of CMS Readout Chip (CROC) sensors to be used in the High Luminosity era of the Large Hadron Collider (HL-LHC) are presented. The HL-LHC peak instantaneous luminosity of $7.5 \times 10^{34} \ \text{cm}^{-2} s^{-1}$ corresponds to an average of around 200 inelastic proton-proton collisions per beam-crossing every 25 ns. In order to efficiently reconstruct and track particles in this extreme and challenging conditions, the present CMS tracking detector will be completely replaced. The new tracking detector consists of an Inner Tracker closest to the beamline and an Outer Tracker surrounding it. These are populated with modules that comprise of readout chips and silicon sensors. The test beam measurements of these modules are vital to understand the performance of the related technologies. Using a primary 120 GeV proton beam from the Main Injector at Fermilab, data was collected at the Fermilab Test Beam Facility (FTBF) using the silicon tracker telescope that provides a precision position measurement of the track impact point with less than 5 $\mu$m uncertainty. The proton beam was incident on a 1x2 planar CROC module developed by Hamamatsu. The sensor has 100x25 $\mu m^2$ standard pixels and also a smaller number of 225x25 $\mu m^2$ longer pixels at the boundary between the two ROCs. We present characterization of these modules that includes pixel efficiency, resolution, cluster size and charge distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Polarization Transfers in Real Compton Scattering by a proton target at JLAB. A new source of information on the 3D shape of the nucleon

In this thesis work, results of the analysis of the polarization transfers measured in real Compton scattering (RCS) by the Collaboration E07-002 at the Je fferson Lab Hall-C are presented. The data were collected at large scattering angle (theta_cm = 70deg) and with a polarized incident photon beam at an average energy of 3.8 GeV. Such a kind of experiments allows one to understand more deeply the reaction mechanism, that involves a real photon, by extracting both Compton form factors and Generalized Parton Distributions (GPDs) (also relevant for possibly shedding light on the total angular momentum of the nucleon). The obtained results for the longitudinal and transverse polarization transfers K_LL and K_LT, are of crucial importance, since they confirm unambiguously the disagreement between experimental data and pQCD prediction, as it was found in E99-114 experiment, and favor the Handbag mechanism. The E99-114 and E07-002 results can contribute to attract new interest on the great yield of the Compton scattering by a nucleon target, as demonstrated by the recent approval of an experimental proposal submitted to the Jefferson Lab PAC 42 for a Wide-angle Compton Scattering experiment, at 8 and 10 GeV Photon Energies. The new experiments approved to run with the updated 12 GeV electron beam at JLab, are characterized by much higher luminosities, and a new GEM tracker is under development to tackle the challenging backgrounds. Within this context, we present a new multistep tracking algorithm, based on (i) a Neural Network (NN) designed for a fast and efficient association of the hits measured by the GEM detector which allows the track identification, and (ii) the application of both a Kalman filter and Rauch-Tung-Striebel smoother to further improve the track reconstruction. The full procedure, i.e. NN and filtering, appears very promising, with high performances in terms of both association effciency and reconstruction accuracy, and these preliminary results will be discussed in detail in the last chapters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-F-T-255: Accuracy and Precision of Dynamic Tracking Irradiation with VERO-4DRT System

Purpose: The VERO-4DRT system is able to provide dynamic tracking irradiation (DTI) for the target with respiratory motion. This technique requires enough commissioning for clinical implementation. The purpose of this study is to make sure the accuracy and precision of DTI using VERO- 4DRT through commissioning from fundamental evaluation to end-to-end test. Method: We evaluated several contents for DTI commissioning: the accuracy of absorption dose at isocenter in DTI, the field size and penumbra of DTI, the accuracy of 4D modeling in DTI. All evaluations were performed by respiratory motion phantom (Quasar phantom). These contents were compared the results between static irradiation and DTI. The shape of radiation field was set to square from 3 cm × 3 cm to 10 cm × 10 cm. The micro 3D chamber and Gafchromic EBT3 film were used for absorbed dose and relative dose distribution measurement, respectively. The sine and irregular shaped waves were used for demonstrative respiratory motion. The visicoil was implanted into the phantom for guidance of respiratory motion. The respiration patterns of frequency and motion amount were set to 10–15 BPM and 1–2 cm, respectively. Results: As the result of absorbed dose of DTI in comparison with static irradiation, the average dose error at isocenter was 0.5% even though various respiratory patterns were set on. As the result of relative dose distribution, the field size (set it on 50% dose line) was not significantly changed in all respiratory patterns. However, the penumbra was larger in greater respiratory motion (up to 4.1 mm). The 4D modeling coincidence between actual and created waves was within 1%. Conclusion: The DTI using VERO-4DRT can provide sufficient accuracy and precision in absorbed dose and distribution. However, the patientspecific quantitative internal margin corresponding respiratory motion should be taken into consideration with image guidance.

60 APPLIED LIFE SCIENCES↗

Evaluations of an adaptive planning technique incorporating dose feedback in image-guided radiotherapy of prostate cancer

Purpose: Online image guidance (IG) has been used to effectively correct the setup error and inter-fraction rigid organ motion for prostate cancer. However, planning margins are still necessary to account for uncertainties such as deformation and intra-fraction motion. The purpose of this study is to investigate the effectiveness of an adaptive planning technique incorporating offline dose feedback to manage inter-fraction motion and residuals from online correction. Methods: Repeated helical CT scans from 28 patients were included in the study. The contours of prostate and organs-at-risk (OARs) were delineated on each CT, and online IG was simulated by matching center-of-mass of prostate between treatment CTs and planning CT. A seven beam intensity modulated radiation therapy (IMRT) plan was designed for each patient on planning CT for a total of 15 fractions. Dose distribution at each fraction was evaluated based on actual contours of the target and OARs from that fraction. Cumulative dose up to each fraction was calculated by tracking each voxel based on a deformable registration algorithm. The cumulative dose was compared with the dose from initial plan. If the deviation exceeded the pre-defined threshold, such as 2% of the D{sub 99} to the prostate, an adaptive planning technique called dose compensation was invoked, in which the cumulative dose distribution was fed back to the treatment planning system and the dose deficit was made up through boost radiation in future treatment fractions. The dose compensation was achieved by IMRT inverse planning. Two weekly compensation delivery strategies were simulated: one intended to deliver the boost dose in all future fractions (schedule A) and the other in the following week only (schedule B). The D{sub 99} to prostate and generalized equivalent uniform dose (gEUD) to rectal wall and bladder were computed and compared with those without the dose compensation. Results: If only 2% underdose is allowed at the end of the treatment course, then 11 patients fail. If the same criteria is assessed at the end of each week (every five fractions), then 14 patients fail, with three patients failing the 1st or 2nd week but passing at the end. The average dose deficit from these 14 patients was 4.4%. They improved to 2% after the weekly compensation. Out of these 14 patients who needed dose compensation, ten passed the dose criterion after weekly dose compensation, three patients failed marginally, and one patient still failed the criterion significantly (10% deficit), representing 3.6% of the patient population. A more aggressive compensation frequency (every three fractions) could successfully reduce the dose deficit to the acceptable level for this patient. The average number of required dose compensation re-planning per patient was 0.82 (0.79) per patient for schedule A (B) delivery strategy. The doses to OARs were not significantly different from the online IG only plans without dose compensation. Conclusions: We have demonstrated the effectiveness of offline dose compensation technique in image-guided radiotherapy for prostate cancer. It can effectively account for residual uncertainties which cannot be corrected through online IG. Dose compensation allows further margin reduction and critical organs sparing.

61 RADIATION PROTECTION AND DOSIMETRY↗

Computational Fluid Dynamics Modeling of the John Day Dam Tailrace

US Army Corps of Engineers-Portland District required that a two-dimensional (2D) depth-averaged and a three-dimensional (3D) free-surface numerical models to be developed and validated for the John Day tailrace. These models were used to assess potential impact of a select group of structural and operational alternatives to tailrace flows aimed at improving fish survival at John Day Dam. The 2D model was used for the initial assessment of the alternatives in conjunction with a reduced-scale physical model of the John Day Project. A finer resolution 3D model was used to more accurately model the details of flow in the stilling basin and near-project tailrace hydraulics. Three-dimensional model results were used as input to the Pacific Northwest National Laboratory particle tracking software, and particle paths and times to pass a downstream cross section were used to assess the relative differences in travel times resulting from project operations and structural scenarios for multiple total river flows. Streamlines and neutrally-buoyant particles were seeded in all turbine and spill bays with flows. For a Total River of 250 kcfs running with the Fish Passage Plan spill pattern and a spillwall, the mean residence times for all particles were little changed; however the tails of the distribution were truncated for both spillway and powerhouse release points, and, for the powerhouse releases, reduced the residence time for 75% of the particles to pass a downstream cross section from 45.5 minutes to 41.3 minutes. For a total river of 125 kcfs configured with the operations from the Fish Passage Plan for the temporary spillway weirs and for a proposed spillwall, the neutrally-buoyant particle tracking data showed that the river with a spillwall in place had the overall mean residence time increase; however, the residence time for 75% of the powerhouse-released particles to pass a downstream cross section was reduced from 102.4 min to 89 minutes.

54 ENVIRONMENTAL SCIENCES↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Variable frequency iteration MPPT for resonant power converters

A method of maximum power point tracking (MPPT) uses an MPPT algorithm to determine a switching frequency for a resonant power converter, including initializing by setting an initial boundary frequency range that is divided into initial frequency sub-ranges bounded by initial frequencies including an initial center frequency and first and second initial bounding frequencies. A first iteration includes measuring initial powers at the initial frequencies to determine a maximum power initial frequency that is used to set a first reduced frequency search range centered or bounded by the maximum power initial frequency including at least a first additional bounding frequency. A second iteration includes calculating first and second center frequencies by averaging adjacent frequent values in the first reduced frequency search range and measuring second power values at the first and second center frequencies. The switching frequency is determined from measured power values including the second power values.

14 SOLAR ENERGY↗

A phase model approach for thermostatically controlled load demand response

A significant portion of electricity consumed worldwide is used to power thermostatically controlled loads (TCLs) such as air conditioners, refrigerators, and water heaters. Because the short-term timing of operation of such systems is inconsequential as long as their long-run average power consumption is maintained, they are increasingly used in demand response (DR) programs to balance supply and demand on the power grid. Here, we present an ab initio phase model for general TCLs, and use the concept to develop a continuous oscillator model of a TCL and compute its phase response to changes in temperature and applied power. This yields a simple control system model that can be used to evaluate control policies for modulating the power consumption of aggregated loads with parameter heterogeneity and stochastic drift. We demonstrate this concept by comparing simulations of ensembles of heterogeneous loads using the continuous state model and an established hybrid state model. The developed phase model approach is a novel means of evaluating DR provision using TCLs, and is instrumental in estimating the capacity of ancillary services or DR on different time scales. We further propose a novel phase response based open-loop control policy that effectively modulates the aggregate power of a heterogeneous TCL population while maintaining load diversity and minimizing power overshoots. This is demonstrated by low-error tracking of a regulation signal by filtering it into frequency bands and using TCL sub-ensembles with duty cycles in corresponding ranges. As a result, control policies that can maintain a uniform distribution of power consumption by aggregated heterogeneous loads will enable distribution system management (DSM) approaches that maintain stability as well as power quality, and further allow more integration of renewable energy sources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

ANGULAR MOMENTUM AND GALAXY FORMATION REVISITED

Motivated by a new wave of kinematical tracers in the outer regions of early-type galaxies (ellipticals and lenticulars), we re-examine the role of angular momentum in galaxies of all types. We present new methods for quantifying the specific angular momentum j, focusing mainly on the more challenging case of early-type galaxies, in order to derive firm empirical relations between stellar j{sub *} and mass M{sub *} (thus extending earlier work by Fall). We carry out detailed analyses of eight galaxies with kinematical data extending as far out as 10 effective radii, and find that data at two effective radii are generally sufficient to estimate total j{sub *} reliably. Our results contravene suggestions that ellipticals could harbor large reservoirs of hidden j{sub *} in their outer regions owing to angular momentum transport in major mergers. We then carry out a comprehensive analysis of extended kinematic data from the literature for a sample of {approx}100 nearby bright galaxies of all types, placing them on a diagram of j{sub *} versus M{sub *}. The ellipticals and spirals form two parallel j{sub *}-M{sub *} tracks, with log-slopes of {approx}0.6, which for the spirals are closely related to the Tully-Fisher relation, but for the ellipticals derives from a remarkable conspiracy between masses, sizes, and rotation velocities. The ellipticals contain less angular momentum on average than spirals of equal mass, with the quantitative disparity depending on the adopted K-band stellar mass-to-light ratios of the galaxies: it is a factor of {approx}3-4 if mass-to-light ratio variations are neglected for simplicity, and {approx}7 if they are included. We decompose the spirals into disks and bulges and find that these subcomponents follow j{sub *}-M{sub *} trends similar to the overall ones for spirals and ellipticals. The lenticulars have an intermediate trend, and we propose that the morphological types of galaxies reflect disk and bulge subcomponents that follow separate, fundamental j{sub *}-M{sub *} scaling relations. This provides a physical motivation for characterizing galaxies most basically with two parameters: mass and bulge-to-disk ratio. Next, in an approach complementary to numerical simulations, we construct idealized models of angular momentum content in a cosmological context, using estimates of dark matter halo spin and mass from theoretical and empirical studies. We find that the width of the halo spin distribution cannot account for the differences between spiral and elliptical j{sub *}, but that the observations are reproduced well if these galaxies simply retained different fractions of their initial j complement ({approx}60% and {approx}10%, respectively). We consider various physical mechanisms for the simultaneous evolution of j{sub *} and M{sub *} (including outflows, stripping, collapse bias, and merging), emphasizing that the vector sum of all such processes must produce the observed j{sub *}-M{sub *} relations. We suggest that a combination of early collapse and multiple mergers (major or minor) may account naturally for the trend for ellipticals. More generally, the observed variations in angular momentum represent simple but fundamental constraints for any model of galaxy formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration Assessment of LED Roadway Lighting: Philadelphia, PA

For this demonstration assessment, 10 different groups of LED luminaires were installed at three sites in Philadelphia, PA. Each of the three sites represented a different set of conditions, most importantly with regard to the incumbent HPS luminaires, which were nominally 100 W, 150 W, and 250 W. The performance of each product was evaluated based on manufacturer data, illuminance calculations, field measurements of illuminance, and the subjective impressions of both regular and expert observers. Most, but not all, of the LED luminaires had a higher rated luminous efficacy compared to the HPS product they were replacing. Some provided more lumens than their HPS counterpart, whereas others emitted fewer, and they drew between 10% and 40% less power. All of the LED luminaires had improved color rendering and a higher CCT. Field illuminance measurements were taken at each site, but the large difference in pole spacing for each area limited the usefulness of that dataset for comparing performance. However, it did reveal that the difference in measured and calculated illuminance was up to approximately 40%, and that the HPS luminaires were more likely to provide lower illuminance than predicted by calculations. In order to compare luminaire performance, supplemental calculations were performed using a single representative model of each of the three sites. These calculations showed that the delivered illuminance from the LED luminaires was generally similar to the baseline HPS luminaires. On average, the LED luminaires were predicted to provide 24% higher initial illuminance on the roadway surface, but 13 % less on the bicycle lanes and 11% less on the adjacent sidewalks. Based on the lumen depreciation factor applied to each luminaire type, the difference in predicted maintained illuminance would change. Two of the three HPS luminaires and seven of the ten LED luminaires were predicted not to meet at least one of the maintained illuminance design criteria. These results are dependent on both the lumen output and luminous intensity distribution characteristics of the luminaires. Importantly, the LED systems were designed with the intent of providing performance similar to the HPS luminaires, rather than to meet illuminance criteria. Despite lower input power for the LED luminaires, energy cost savings are not currently possible for Philadelphia because they have yet to reach an agreement for a new tariff for LED street lighting with the local utility, a situation that is common throughout the country. Even with a new tariff, energy savings alone are unlikely to result in a reasonable payback period given current LED efficacy levels. However, additional cost savings from reduced maintenance could make widespread luminaire replacement cost effective. In particular, the LED luminaires installed at one of the three sites—where the luminaires were mounted on an elevated rail track—were less susceptible the premature failure from strong vibrations. Two sets of subjective evaluations were collected: one included local residents and passersby, whereas the other was completed by lighting professionals. In general, there were only small deviations in the perception of the luminaires, and it would be difficult to select any products that were clearly superior to the others in the same category. Nonetheless, both groups generally viewed the demonstration LED lighting favorably, especially compared to the typical HPS luminaires used in Philadelphia.

GATEWAY↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

The evolution of far-infrared co emission from protostars

We investigate the evolution of far-IR CO emission from protostars observed with Herschel/PACS for 50 sources from the combined sample of HOPS and DIGIT Herschel key programs. From the uniformly sampled spectral energy distributions, whose peaks are well sampled, we computed the L{sub bol}, T{sub bol}, and L{sub bol}/L{sub smm} for these sources to search for correlations between far-IR CO emission and protostellar properties. We find a strong and tight correlation between far-IR CO luminosity (L{sub CO}{sup fir}) and the bolometric luminosity (L{sub bol}) of the protostars with L{sub CO}{sup fir} ∝L{sub bol}{sup 0.7}. We, however, do not find a strong correlation between L{sub CO}{sup fir} and protostellar evolutionary indicators, T{sub bol} and L{sub bol}/L{sub smm}. FIR CO emission from protostars traces the currently shocked gas by jets/outflows, and far-IR CO luminosity, L{sub CO}{sup fir}, is proportional to the instantaneous mass-loss rate, M-dot {sub out}. The correlation between L{sub CO}{sup fir} and L{sub bol}, then, is indicative of instantaneous M-dot {sub out} tracking instantaneous M-dot {sub acc}. The lack of a correlation between L{sub CO}{sup fir} and evolutionary indicators T{sub bol} and L{sub bol}/L{sub smm} suggests that M-dot {sub out} and, therefore, M-dot {sub acc} do not show any clear evolutionary trend. These results are consistent with mass accretion/ejection in protostars being episodic. Taken together with the previous finding that the time-averaged mass-ejection/accretion rate declines during the protostellar phase, our results suggest that the instantaneous accretion/ejection rate of protostars is highly time variable and episodic, but the amplitude and/or frequency of this variability decreases with time such that the time-averaged accretion/ejection rate declines with system age.

79 ASTRONOMY AND ASTROPHYSICS↗

In situ measurement of three-dimensional intergranular stress localizations and grain yielding under elastoplastic axial-torsional loading

The three-dimensional grain-averaged response of solid bar samples under non-proportional (NP) elastoplastic axial-torsional loading was investigated using in situ high energy diffraction microscopy (HEDM) and companion crystal plasticity finite element (CPFE) modeling. Important stress metrics including applied shear (σ θZ ) and axial (σ ZZ ) stress tensor components, stress and stress deviator tensor invariants (I 1 , J 2 , and J 3 ), von Mises equivalent stress (σ$^{grain}_{VM}$), maximum resolved shear stress (mRSS), stress triaxiality (η), and lode angle parameter ($\barθ$) values were tracked for ~300 grains under two different loading conditions: (1) Torsion-dominated loading (low NP) and (2) Tension-torsion loading (high NP) in equiatomic NiCoCr, a representative multicomponent face-centered cubic (FCC) superalloy. Overall, significant stress localizations existed within both samples as evidenced by the radial dependence of grain-resolved σ θZ , σ$^{grain}_{VM}$, and J 2 ; by comparison, I 1 , J 3 , η, and $\barθ$ metrics did not show discernible trends within the volume. These stress localizations reveal a complex interplay between axial and shear stress components (e.g., stress coupling) resulting in grain yielding near the sample surface largely driven by shear stress, whereas internal grain yielding was largely accommodated by axial stress. Grain-resolved stress localization trends were described well by the CPFE model, although some discrepancies in magnitude occurred, particularly for volumetric stress metrics (I 1 and η) due to initial type II residual stress distributions. The superposition of initial residual stress states onto CPFE grain-resolved data significantly improved model accuracy for η. This suggests that residual stresses more strongly influence the simulation of volumetric rather than deviatoric (yield) stress metrics.

36 MATERIALS SCIENCE↗

Vertical column dual-comb spectroscopy to a TBS

Open-path dual-frequency-comb spectroscopy (DCS) is a broadband, high spectral resolution, and high precision method for measuring gas concentrations over kilometer-scale paths. It has been used for detection and quantification of emissions of pollutants, hazardous gasses, and greenhouse gasses (GHGs). DCS has been shown to measure trace-gas mixing ratios with 0.14%-0.4% agreement between instruments. To achieve high signal-to-noise ratios (SNRs) with DCS, comb light is targeted onto a retroreflector at the end of the measurement path, which returns the signal to a detector co-located with the launch signal. Installing the retroreflector on a mobile platform such as a balloon or unmanned aerial vehicle (UAV) extends the capabilities of DCS by enabling variable path lengths, greater mobility, and access to higher altitudes. Mobile-target DCS has many uses in plume and leak detection, emissions modeling, and planetary boundary layer (PBL) studies. It is a promising method for observing vertical distributions of GHGs and mixing processes in the PBL, which are difficult to measure but important for pollution and climate monitoring as well as for understanding transport of gasses through the atmosphere. Tethered balloons are an intriguing platform because they enable longer flight durations and higher altitudes than easily obtainable with a UAV and thus allow for column measurements up to and above the PBL. New measurements completed in October/November 2024 reach the highest altitudes above ground level yet achieved by mobile-target DCS. For these measurements, the retroreflector was mounted on a 7 m diameter tethered helium balloon. An actively tracking gimbal on the ground holds the DCS launch telescope and keeps the 5 cm beam pointed onto the retroreflector while the balloon is lifted, lowered, and moved by wind and turbulence.

atmosphere↗

Spacer Grid and Mixing Vanes Effects Study on Two-phase Flow Using Bubble Tracking Simulations

In Light Water Reactor (LWR) cores, the nuclear fuel rods are arranged together as rod bundles in a triangular or square pattern. The fuel rod bundles are supported by the spacer grids with mixing vanes. An understanding of spacer grid and mixing vanes effect is important since it has a direct impact on the turbulence structure in the flow and the heat removal efficiency from the fuel rod surface. Although a considerable amount of literature has been published on the experimental investigation of spacer grid and mixing vanes effect, the measurements were mainly focused on single-phase flow. The influence of spacer grid and mixing vanes on two-phase flow is yet to be fully understood. Some preliminary research efforts have been invested in nuclear community. For example, Wheeler et al. experimentally studied the effects of spacer grid in air-water two-phase flow. Although mixing vanes are not considered, they presented interesting results of time-averaged two-phase flow quantities at upstream and downstream locations of the spacer grid. Over the past decades, the rapid development of High-Performance Computing (HPC) is allowing for the increasingly larger-scale high-fidelity simulations. Thanks to this favorable historical trend, Direct Numerical Simulation (DNS), integrated with Interface Tracking Methods (ITM), has been emerging as a valuable tool to complement and expand our ability to understand the two-phase flow phenomenon. Meanwhile, in order to make best use of the large-scale two-phase flow simulations, advanced data analysis techniques are being developed, as they enable the extraction of detailed parameters about individual bubble behavior. The level set ITM is utilized in our DNS flow solver, which makes use of a signed distance field. The gas-liquid interface is modeled by the zero level set. The level set method can be readily used to distinguish different phases based on the sign of corresponding level set value (e.g. the sign is positive in the liquid phase while negative in the gas phase.). However, the traditional level set approach is not able to collect calculated values and associate with specific bubbles when multiple (even thousands of) bubbles present in the simulations of two-phase flow. This drawback hinders the collection of useful bubble information, which can give us valuable insights about bubbly flows. For example, how the different local fluid conditions could affect bubble interfacial forces, bubble deformation level, and eventually the bubble distribution throughout the whole domain. A bubble tracking methodology has been developed to address the drawbacks and improve the data collection efficiency of level set based two-phase flow simulations. In the present work, a single Pressurized Water Reactor (PWR) subchannel with reduced size spacer grid and mixing vanes is chosen as the computational domain. The springs and dimples of the spacer grid are not represented for simplicity in the present investigation. The bubble tracking methodology is applied to the simulations of two-phase bubbly flow through spacer grid and mixing vanes region. In the intended simulation, the liquid turbulence will be fully resolved by DNS while the two-phase behaviors are captured by level set ITM. Bubble tracking data are to be processed to investigate the spacer grid and mixing vanes effect on two-phase bubbly flow. (authors)