Search NASA⌕ Search

SEARCH · Search NASA

Results for “dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A shielding application of perturbation theory to determine changes in neutron and gamma doses due to changes in shield layers

Perturbation theory for fixed sources was applied to radiation shielding problems to determine changes in neutron and gamma ray doses due to changes in various shield layers. For a given source and detector position, the perturbation method enables dose derivatives due to all layer changes to be determined from one forward and one inhomogeneous adjoint calculation. The direct approach requires two forward calculations for the derivative due to a single layer change. Hence, the perturbation method for a obtaining dose derivatives permits an appreciable savings in computation for a multilayered shield. A comparison was made of the fractional change in the dose per unit change in shield layer thickness as calculated by perturbation theory and by successive direct calculations; excellent agreement was obtained between the two methods.

Fieno, D.↗

Measured and Calculated Neutron Spectra and Dose Equivalent Rates at High Altitudes; Relevance to SST Operations and Space Research

Results of the NASA Langley-New York University high-altitude radiation study are presented. Measurements of the absorbed dose rate and of secondary fast neutrons (1 to 10 MeV energy) during the years 1965 to 1971 are used to determine the maximum radiation exposure from galactic and solar cosmic rays of supersonic transport (SST) and subsonic jet occupants. The maximum dose equivalent rates that the SST crews might receive turn out to be 13 to 20 percent of the maximum permissible dose rate (MPD) for radiation workers (5 rem/yr). The exposure of passengers encountering an intense giant-energy solar particle event could exceed the MPD for the general population (0.5 rem/yr), but would be within these permissible limits if in such rare cases the transport descends to subsonic altitude; it is in general less than 12 percent of the MPD. By Monte Carlo calculations of the transport and buildup of nucleons in air for incident proton energies E of 0.02 to 10 GeV, the measured neutron spectra were extrapolated to lower and higher energies and for galactic cosmic rays were found to continue with a relatively high intensity to energies greater than 400 MeV, in a wide altitude range. This condition, together with the measured intensity profiles of fast neutrons, revealed that the biologically important fast and energetic neutrons penetrate deep into the atmosphere and contribute approximately 50 percent of the dose equivalant rates at SST and present subsonic jet altitudes.

Foelsche, T.↗

Computer subroutines for the estimation of nuclear reaction effects in proton-tissue-dose calculations

Calculational methods for estimation of dose from external proton exposure of arbitrary convex bodies are briefly reviewed. All the necessary information for the estimation of dose in soft tissue is presented. Special emphasis is placed on retaining the effects of nuclear reaction, especially in relation to the dose equivalent. Computer subroutines to evaluate all of the relevant functions are discussed. Nuclear reaction contributions for standard space radiations are in most cases found to be significant. Many of the existing computer programs for estimating dose in which nuclear reaction effects are neglected can be readily converted to include nuclear reaction effects by use of the subroutines described herein.

Wilson, J. W.↗

Nuclear emulsion measurements of the dose contribution from tissue disintegration stars on the Apollo-Soyuz mission

A total of 996 disintegration stars were prong-counted in two 100 micron llford K.2 emulsions from the dosimeter of the Docking Pilot on Apollo-Soyuz. The change of slope of the distribution at a prong number of about 6 or 7 indicates 219 stars as originating in gelatin. Applying the QF values set forth in official regulations to the energy spectra of the proton and a alpha prongs of the gelatin stars leads to a tissue star dose of 7.8 millirad or 45 millirem. The quoted values do not include the dose contribution from star-produced neutrons since neutrons do not leave visible prongs in emulsion. Nuclear theory, in good agreement with measurements of galactic radiation in the earth's atmosphere, indicates that the dose equivalent from neutrons is about equal to the one from all ionizing secondaries of stars. Application of this proposition to the star prong spectrum found on Apollo-Soyuz would set the total tissue star dose for the mission at approximately 90 millirem.

Schaefer, H. J.↗

Deposition and dose from the 18 May 1980 eruption of Mount St. Helens

The downwind deposition and radiation doses was calculated for the tropospheric part of the ash cloud from the May 18, 1980 eruption of Mount St. Helens, by using a large cloud diffusion model. The naturally occurring radionnuclides of radium and thorium, whose radon daughters normally seep very slowly from the rocks and soil, were violently released to the atmosphere. The largest dose to an individual from these nuclides is small, but the population dose to those affected by the radioactivity in the ash is about 100 person rem. This population dose from Mount St. Helens is much greater than the annual person rem routinely released by a typical large nuclear power plant. It is estimated that subsequent eruptions of Mount St. Helens have doubled or tripled the person rem calculated from the initial large eruption. The long range global ash deposition of the May 18 eruption is estimated through 1984, by use of a global deposition model. The maximum deposition is nearly 1000 kg square km and occurs in the spring of 1981 over middle latitudes of the Northern Hemisphere.

Peterson, K. R.↗

Retention of ion-implanted-xenon in olivine: Dependence on implantation dose

The diffusion of Xe in olivine, a major mineral in both meteorites and lunar samples, was studied. Xe ions were implanted at 200 keV into single-crystal synthetic-forsterite targets and the depth profiles were measured by alpha particle backscattering before and after annealing for 1 hour at temperatures up to 1500 C. The fraction of implanted Xe retained following annealing was strongly dependent on the implantation dose. Maximum retention of 100% occurred for an implantion dose of 3 x 10 to the 15th power Xe ions/sq cm. Retention was less at lower doses, with (approximately more than or = 50% loss at one hundred trillion Xe ions/sq cm. Taking the diffusion coefficient at this dose as a lower limit, the minimum activation energy necessary for Xe retention in a 10 micrometer layer for ten million years was calculated as a function of metamorphic temperature.

Melcher, C. L.↗

Retention of ion-implemented-xenon in olivine - Dependence on implantation dose

The diffusion of Xe in olivine, a major mineral in both meteorites and linear samples, was studied. Xe ions were implanted at 200 keV into single-crystal synthetic-forsterite targets and the depth profiles were measured by alpha particle backscattering before and after annealing for 1 hour at temperatures up to 1500 C. The fraction of implanted XE retained following annealing was strongly dependent on the implantation dose. Maximum retention of 100 percent occurred for an implanting dose of 3 x 10 to the 15th power Xe ions/sq cm. Retention was less at lower doses, with approximately more than or = 50 percent loss at one hundred trillion Xe ions/sq cm. Taking the diffusion coefficient at this dose as a lower limit, the minimum activation energy necessary for Xe retention in a 10 micrometer layer for ten million years was calculated as a function of metamorphic temperature. Previously announced in STAR as N83-18528

Melcher, C. L.↗

Radiation dose to critical body organs for October 1989 proton event

The Geostationary Operational Environmental Satellite (GOES-7) provides high-quality environmental data about the temporal development and energy characteristics of the protons emitted during a solar particle event. The GOES-7 time history of the hourly averaged integral proton flux for various particle kinetic energies are analyzed for the solar proton event occurring October 19-29, 1989. This event is similar to the August 1972 event that has been widely studied to estimate free-space and planetary radiation-protection requirements. By analyzing the time-history data, the dose rates, which can vary over many orders of magnitude in the early phases of the flare, can be estimated as well as the cumulative dose as a function of time. When basic transport results are coupled with detailed body organ thickness distributions calculated with the Computerized Anatomical Man and Computerized Anatomical Female models, the dose rates and cumulative doses to specific organs can be predicted. With these results, the risks of cancer incidence and mortality are estimated for astronauts in free space protected by various water shield thicknesses.

Simonsen, Lisa C.↗

Predictions of dose from electrons in space

The objective of the project is to develop a general-purpose, user-friendly computerized database and code package, for the PC as well as larger computers, which can be used for the routine prediction of the absorbed dose from incident electrons and their secondary bremsstrahlung (and from incident protons) as functions of the thickness of aluminum shielding in space. The assumption of homogeneous aluminum shields and of isotropic incident fluxes (at least in a time-averaged sense) allows for the rather reliable conversion of doses in slabs to those in other simple bodies, such as spherical and cylindrical solids and shells. On such a basis, depth-dose data for monoenergetic incident radiation can be generated once-and-for-all from accurate transport calculations, and this database can then be used repeatedly in rapid dose predictions for arbitrary radiation spectra and for a variety of spacecraft sizes and shapes, without recourse to the very time-consuming Monte Carlo calculations. This project entails a thorough updating, extension, and refinement of our earlier SHIELDOSE package, with the goal of a more reliable, fool-proof, and general system.

Seltzer, Stephen M.↗

Summary of LET spectra and dose measurements on ten STS missions

A comparison of linear energy transfer (LET) spectra measurements made with plastic nuclear track detectors (PNTD's) from area passive dosimeters (APD's), was made for ten different STS missions under similar shielding. The results show that integral flux, dose rate and equivalent dose rate values follow a general increase with respect to increasing orbital inclination and altitude but that there are large variations from a simple relationship. This is to be expected since it has been shown that Shuttle attitude variations, combined with the anisotropic particle flux at the South Atlantic Anomaly (SAA), can result in differences of a factor of 2 in dose rate inside the Shuttle (Badhwar et al., 1995). Solar cycle and shielding differences also result in variations in radiation dose between STS missions. Spaceflight dosimeters from the STS missions are also being used in the development of a method for increasing LET spectra measurement accuracy by extending LET measurements to particle tracks of ranges 10-80 microns. Refinements in processing and measurement techniques for the flight PNTD's have yielded increased detection efficiencies for the short tracks when LET spectra determined by using the standard and refined methods were intercompared.

Source record↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day(exp -1) have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLD's) made in U.S.S.R. and U.S.A. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

Watts, J. W., Jr.↗

Solar particle dose rate buildup and distribution in critical body organs

Human body organs have varying degrees of radiosensitivity as evidenced by radioepidemiologic tables. The major critical organs for both the male and female that have been identified include the lung, thyroid, stomach, and breast (female). Using computerized anatomical models of the 50th percentile United States Air Force male and female, we present the self-shielding effects of these various body organs and how the shielding effects change as the location (dose point) in the body varies. Several major solar proton events from previous solar cycles and several events from the current 22nd solar cycle have been analyzed. The solar particle event rise time, peak intensity, and decay time vary considerably from event to event. Absorbed dose and dose equivalent rate calculations and organ risk assessment data are presented for each critical body organ. These data are compared with the current NASA astronaut dose limits as recommended by the National Council on Radiation Protection and Measurements.

Atwell, William↗

Detailed Comparison of Observed Dose-Time Profile of October 19-20, 1989 SPE on Mir with Model Calculations

The dose rate dynamics of the October 19-20,1989 solar energetic particle (SPE) event as observed by the Liulin instrument onboard the Mir orbital station was analyzed in light of new calculations of the geomagnetic cutoff and improved estimates of the less than 100 MeV energy spectra from the GOES satellite instrument. The new calculations were performed using the as-flown Mir orbital trajectory and includes time variations of the cutoff rigidity due to changes in the kappa (sub p) index. Although the agreement of total event integrated calculated dose to the measured dose is good, it results from some measured dose-time profile been higher and some lower than model calculations. They point to the need to include the diurnal variation of the geomagnetic cutoff and modifications of the cutoffs to variations in kappa (sub p) in model calculations. Understanding of such events in light of the upcoming construction of the International Space Station during the period of maximum solar activity needs to be vigorously pursued.

Badhwar, Gautam D.↗

Long-term effects of low-dose proton radiation on immunity in mice: shielded vs. unshielded

BACKGROUND: Outside the protection of the terrestrial environment, astronauts on any long-term missions will unavoidably be exposed to fields of charged particle radiation dominated by protons. These fields and their biological risks are modified in complex ways by the presence of protective shielding. METHODS: To examine the long-term effects of space-like proton exposures on immune status, we treated female C57BL/6 mice with 3 or 4 Gy of 250 MeV monoenergetic protons or the complex space-like radiation field produced after 250 MeV protons are transported through 15 g x cm(-2) aluminum shielding. The animals were euthanized 122 d post-irradiation and lymphocyte phenotypes, hematological parameters, and lymphocyte blastogenesis were characterized. RESULTS: There were significant dose-dependent decreases in macrophage, CD3+/CD8+ T, NK, platelet, and red blood cell populations, as well as low hematocrit and hemoglobin levels. In contrast, dose-dependent increases in spontaneous, but not mitogen-induced, blastogenesis were noted. The differences in dose composition between pristine and shielded proton fields did not lead to significant effects in most measures, but did result in significant changes in monocyte and macrophage populations and spontaneous blastogenesis in the spleen. CONCLUSIONS: The data indicate that whole body exposure to proton radiation at doses of the order of large solar particle events or clinical treatment fractions may have long-term effects on immune system status.

NASA Discipline Radiation Health↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Depth distribution of absorbed dose on the external surface of Cosmos 1887 biosatellite

Significant absorbed dose levels exceeding 1.0 Gy day-1 have been measured on the external surface of the Cosmos 1887 biosatellite as functions of depth in stacks of thin thermoluminescent detectors (TLDs) of U.S.S.R. and U.S.A. manufacture. The dose was found to decrease rapidly with increasing absorber thickness, thereby indicating the presence of intensive fluxes of low-energy particles. Comparison between the U.S.S.R. and U.S.A. results and calculations based on the Vette Model environment are in satisfactory agreement. The major contribution to the dose under thin shielding thickness is shown to be from electrons. The fraction of the dose due to protons and heavier charged particles increases with shielding thickness.

NASA Discipline Number 04-10↗

Dose equivalent near the bone-soft tissue interface from nuclear fragments produced by high-energy protons

During manned space missions, high-energy nucleons of cosmic and solar origin collide with atomic nuclei of the human body and produce a broad linear energy transfer spectrum of secondary particles, called target fragments. These nuclear fragments are often more biologically harmful than the direct ionization of the incident nucleon. That these secondary particles increase tissue absorbed dose in regions adjacent to the bone-soft tissue interface was demonstrated in a previous publication. To assess radiological risks to tissue near the bone-soft tissue interface, a computer transport model for nuclear fragments produced by high energy nucleons was used in this study to calculate integral linear energy transfer spectra and dose equivalents resulting from nuclear collisions of 1-GeV protons transversing bone and red bone marrow. In terms of dose equivalent averaged over trabecular bone marrow, target fragments emitted from interactions in both tissues are predicted to be at least as important as the direct ionization of the primary protons-twice as important, if recently recommended radiation weighting factors and "worst-case" geometry are used. The use of conventional dosimetry (absorbed dose weighted by aa linear energy transfer-dependent quality factor) as an appropriate framework for predicting risk from low fluences of high-linear energy transfer target fragments is discussed.

NASA Discipline Number 45-10↗

Solar Variability and the Near-Earth Environment: Mining Enhanced Low Dose Rate Sensitivity Data From the Microelectronics and Photonics Test Bed Space Experiment

This effort is a detailed analysis of existing microelectronics and photonics test bed satellite data from one experiment, the bipolar test board, looking to improve our understanding of the enhanced low dose rate sensitivity (ELDRS) phenomenon. Over the past several years, extensive total dose irradiations of bipolar devices have demonstrated that many of these devices exhibited ELDRS. In sensitive bipolar transistors, ELDRS produced enhanced degradation of base current, resulting in enhanced gain degradation at dose rates <0.1 rd(Si)/s compared to similar transistors irradiated at dose rates >1 rd(Si)/s. This Technical Publication provides updated information about the test devices, the in-flight experiment, and both flight-and ground-based observations. Flight data are presented for the past 5 yr of the mission. These data are compared to ground-based data taken on devices from the same date code lots. Information about temperature fluctuations, power shutdowns, and other variables encountered during the space flight are documented.

Turflinger, T.↗