Search NASA⌕ Search

SEARCH · Search NASA

Results for “dynamic solar control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Highly Conjugated Porphyrin Arrays Enable Optical Resolution of Ferromagnetic and Antiferromagnetic Aligned States of the Triplet Exciton and an Incorporated Stable Radical

Well-defined photogenerated molecular spin systems have potential utility in spintronics and quantum information science (QIS). Because molecular magnetic, optical, and electronic properties can be controlled by design, diverse spin systems can be prepared at modest temperatures. Photogenerated molecular spin systems often involve states prepared from the interaction of excitons and charges. Resolving the nature of electron spin alignment in photogenerated spin states described by the coupling of a triplet exciton and a stable radical commonly relies on EPR spectroscopy. Here, we describe ethyne-bridged (porphinato)metal ( PM n ) oligomers that incorporate a macrocycle-bound Cu(II) radical center. Upon photoexcitation of such PM n arrays, a singdoublet ( 2 S 1 ) state is formed; ultrafast internal conversion (IC) then produces a tripdoublet ( 2 T 1 ) state, which undergoes intersystem crossing (ISC) to produce a tripquartet ( 4 T 1 ) state, before relaxation to the ground state ( 2 S 0 ). These highly conjugated Cu(II) radical-containing PMn arrays enable direct observation of copper porphyrin 2 T 1 → 4 T 1 ISC dynamics from the biexponential decay of the near-infrared (NIR) 2,4 T 1 → 2,4 T n transient absorption manifold. Multireference n-electron valence perturbation theory (NEVPT2) computations illuminate how PM n electronic structure controls the relaxation dynamics of these long-lived (>10 ns) electronically excited multiplet states. These studies show that highly conjugated and polarizable porphyrin arrays incorporating stable spin centers provide rare π-delocalized systems where the ferromagnetic and antiferromagnetic alignment between a triplet exciton and a stable radical are both spectrally resolved and addressable using transient optical spectroscopy at wavelengths exceeding 1 μm, providing new opportunities to QIS.

14 SOLAR ENERGY↗

Progressing Analysis of Variable Electric Rates (PAVER) Study

The Progressing Analysis of Variable Electric Rates (PAVER) study analyzed the impact of a range of time-varying electric rates on the performance of a regional electric grid and the resulting costs for participating and non-participating customers. This analysis leveraged and extended the work of PNNL’s Distribution System Operator with Transactive (DSO+T) study. Five different rate designs were included: a flat volumetric energy charge, a typical Time of Use (TOU) rate, a dynamic energy (DE) rate (based on wholesale locational marginal prices), a dynamic energy and capacity (DE+C) rate, and, finally, a Block and Swing (B&S) rate that billed customers based on their average load profile at constant pricing, but used the DE+C dynamic price for load deviations from their average profile. These rates were analyzed in a large-scale co-simulation of an entire regional grid with a customer population representative of the current state. A large fraction (80%) of residential and commercial customers were assumed to participate in these time-varying rates with automatically controlled HVAC, water heaters, electric vehicles, and batteries. This study assumed no industrial sector participation. The DE and DE+C rates saw system peak loads reduced by 6-7%, while the large participation in the TOU rate case saw a significant rebound effect and a resulting peak load increase of >5%. The impacts to the annual and peak system demand impacted system wholesale prices and the overall grid operating costs. This cost structure determined the revenue needed to be collected from customers by each rate design. Participating customers on the DE and DE+C rates (located in one of the modeled DSOs) saw reductions in average annual electricity bills of 11-17% with average increases in monthly bill variation of no more than 13%. At such high participation levels, TOU customers saw 10% higher average annual bills (due to system-wide rebound effects) and average increased monthly bill variation of 16%. Residential owners of large flexible loads (such as electric vehicles) saw larger bill savings (17-20%) when on a fully dynamic rate. The presence of on-site generation (such as rooftop solar) did not appear to appreciably change customer outcomes. Customers on the Block and Swing rate did see 6% lower monthly bill variation (as intended) than the flat rate case, but at the expense of appreciable bill savings, which were only 3%, comparable to the savings seen by non-participants. Given this finding we recommend that additional research be conducted into how best various bill protection mechanisms can balance minimizing customer bill variation with providing financial incentives commensurate with the flexibility customers provide. We also recommend that customer outcomes be explored across a range of regions using current actual customer and system cost data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Harnessing Intermolecular Interactions to Promote Long-Lived Photoinduced Charge Separation from Copper Phenanthroline Chromophores

In this study, facilitating photoinduced electron transfer (PET) while minimizing rapid charge-recombination processes to produce a long-lived charge-separated (CS) state represents a primary challenge associated with achieving efficient solar fuel production. Natural photosynthetic systems employ intermolecular interactions to arrange the electron-transfer relay in reaction centers and promote a directional flow of electrons. This work explores a similar tactic through the synthesis and ground- and excited-state characterization of two Cu(I)bis(phenanthroline) chromophores with homoleptic and heteroleptic coordination geometries and which are functionalized with negatively charged sulfonate groups. The addition of sulfonate groups enables solubility in pure water, and it also induces assembly with the dicationic electron acceptor methyl viologen (MV 2+ ) via bimolecular, dynamic electrostatic interactions. The effect of the sulfonate groups on the ground- and excited-state properties was evaluated by comparison with the unsulfonated analogues in 1:1 acetonitrile/water. The excited-state lifetimes for all sulfonated complexes are similar to what we expect from previous literature, with the exception of the sulfonated heteroleptic complex whose metal-to-ligand charge-transfer (MLCT) lifetime in water has two components that are fit to 10 and 77 ns. For the sulfonated complexes, we detected reduced MV +$\bullet$ in both solvent environments following MLCT excitation, but control measurements in 1:1 acetonitrile/water with the unsulfonated analogues showed no PET to MV 2+ , indicating that electrostatically driven supramolecular assemblies of the sulfonated complexes with MV 2+ facilitate the observed PET. Additionally, the strength of the intermolecular interactions driving the formation of these assemblies changes drastically with the solvent environment. In 1:1 acetonitrile/water, PET occurred from both sulfonated complexes with quantum yields (Φ ET ) of 2-3% but increased to a remarkable 98% for the sulfonated heteroleptic complex with a 3 μs CS-state lifetime in water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coalescence of GaP on V-Groove Si

In recent years, better understanding and control over the formation of crystalline defects during the direct epitaxy of III-V semiconductors on Si substrates via metal organic vapor phase epitaxy (MOVPE) has enabled large gains in III-V-on-Si solar cell efficiency, pointing to pathway to lower-cost, high-performance III-V solar cells. However, such results have only been achieved on costly chemo-mechanically-polished (CMP) Si wafers. The use of V-groove nanopatterned Si substrates has demonstrated similarly high-crystalline-quality III-V-on-Si epitaxy, but also can be combined with lower-cost polishing techniques. Although they offer a potential cost advantage, growth on V-groove substrates adds challenges not present for epitaxy on planar wafers (the III-V material must be coalesced into a thin film after an initial nucleation stage). MOVPE growth conditions that promote highly facet-selective lateral growth needed for coalescence are generally actively avoided for conventional thin fim growth, so growth conditions need to be re-developed for V-groove-based epitaxy. Additionally, coalescence add complexity to the dislocation dynamics related to lattice relaxation, so strategies used to keep threading dislocation density (TDD) low on planar substrates need to be re-tuned for V-grooves. We have studied the morphological evolution and dislocation dynamics of GaP grown on V-groove Si by MOVPE. Growth conditions of V/III=5,000 and Tg=800 degrees C were uniquely found to produce extremely smooth coalesced thin films, with an RMS roughness of 0.2 nm measured by AFM. Additionally, at this growth condition, we identified two regimes of growth determined by the width of the SiNx cap (a remnant of the nanopatterning process) at the top of the V-grooves. For narrow caps, the GaP coalesces into a thin film, and for wide caps, the GaP evolves into {1 1 1}-faceted diamonds that do not coalesce. We suggest the influence of Si from the sidewalls of the V-grooves on the surface reconstruction of the GaP as the mechanism for this effect, with reflection difference spectroscopy (RDS) and Si doping experiments supporting this theory. In addition to morphology, the dislocation dynamics of the system were studied with electron channeling contrast imaging (ECCI) and transmission electron microscopy (TEM). The TDD of the coalesced GaP films was found to be 5 x 10^7 cm^-2 after coalescence via ECCI, a level still too high for high-quality solar cells. However, misfit dislocations crossing multiple grooves greater than 20 micrometers long were observed in ECCI, suggesting that the V-grooves do not block dislocation glide. TEM prior to and after coalescence was used to distinguish between dislocation creation driven by growth conditions and coalescence. Finally, strategies to reduce the dislocation density to levels acceptable for solar cells will be discussed.

GaP↗

Behind the Meter Storage for Electric Vehicle Charging, Electrochemical and Thermal Energy Storage, and Solar Photovoltaic

In response to the potentially large and irregular demand from EVs, along with changing load profiles from buildings with on-site generation, utilities are evaluating multiple options for managing dynamic loads, including time-of-use pricing, demand charges, battery storage, and curtailment of variable generation. Buildings, as well as commercial, public, and workplace EV charging operations, can use a combination of electrochemical battery storage and thermal energy storage coupled with on-site generation to manage energy costs as well as provide resiliency and reliability for EV charging and building energy loads. We are completing a behind the meter storage analysis that focuses on determining the optimal system designs and energy flows for thermal and electrochemical behind the meter storage with on-site solar photovoltaic (PV) generation enabling electric vehicle charging in various climates, building types, and utility rate structures. In completing this analysis, we have developed a tool that combines existing battery models via the System Advisor Model (SAM) and building modeling software via EnergyPlus into a single interface. This tool allows us to simulate a building with a detailed battery model to properly size the battery, thermal energy storage, and solar PV systems to maximize profit for the system owner. This also allows us to assess how the battery degrades under various supervisory control dispatch algorithms to control charging/discharging; we can also see how thermal energy storage is created and used to complement the battery to reduce thermal loads in the building. With this project, we can analyze new batteries that are designed specifically for energy storage, rather than designed to be extremely energy dense for electric vehicle applications, using battery lifetime models from other national labs and the existing SAM battery model, which has detailed lifetime and degradation parameters. We can also assess novel thermal storage technologies by integrating them into the whole building energy simulation program EnergyPlus. Because the model calls both SAM and EnergyPlus, required inputs need to be compatible for both models. These inputs include, on a high-level, the following: weather files, building and electric vehicle load profiles, electricity rate tariff information, and system cost information for the stationary battery, solar PV, and thermal storage system. The various buildings we are studying for this analysis are retail big-box grocery store, commercial office building, fleet vehicle depot and operations facility, multi-family residential, and electric vehicle charging station. For these different applications, the battery and thermal storage will be dispatched differently, and the various technologies are sized differently to optimize cost.

30 DIRECT ENERGY CONVERSION↗

Energy flexibility of residential buildings: A systematic review of characterization and quantification methods and applications

With building electric demand becoming increasingly dynamic, and a growing percentage of intermittent renewable power generation from solar photovoltaics and wind turbines, the power grid is facing increasing challenge to manage the real time balance between the supply and demand. With advancements in smart sensing and metering, smart appliances, electric vehicles, and energy storage technologies, demand side management of residential buildings can help the grid to improve stability by optimizing flexible loads. This paper reviews recent studies on residential building demand side management, with a focus on characterization and quantification of energy flexibility covering various types of flexible loads, metrics, methods, and applications. The reviewed studies showed four levels of applications: building level (45%), district or community level (29%), system level (19%), and building sector level (7%). Shifting loads is the dominant flexibility type in 60% of applications, followed by shedding (19%), generation (16%), and modulating (6%). Depending on the technology and application scope, flexible operations have a wide range of performance, with peak power reductions of 1%~65%, energy savings up to 60%, operational cost reduction of 1%~48%, and greenhouse gas emission reductions of up to29%. More than half (51%) of the studies employed control strategies to achieve flexibility; among those 72% used optimal controls, while 28% used rule-based controls. About 58% of the studies used mathematical formulation to quantify energy flexibility. Most studies were based on simulation, while less than 15% of the studies had measurements from experiments or field tests. The review reveals research opportunities to address significant gaps in the existing literature: (1) establishing a common definition and performance metrics for energy flexibility of buildings that are technology and application agnostic, (2) developing an ontology to standardize representation of flexibility resources for interoperability, (3) integrating occupant impacts into the quantification and optimization of energy flexibility, and (4) developing requirements and credits of energy flexibility in building energy codes and standards. Findings from the review can inform future research and development of energy flexible buildings which are essential to a reliable and resilient power grid.

Li, H↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

CsI-Antisolvent Adduct Formation in All-Inorganic Metal Halide Perovskites

The excellent optoelectronic properties shown by hybrid organic/inorganic metal halide perovskites are all predicated on precisely controlling the exact nucleation and crystallization dynamics that occur during film formation. In general, high-performance thin films are obtained by a method commonly called solvent engineering (or antisolvent quench) processing. The solvent engineering method removes excess solvent, but importantly leaves behind solvent that forms chemical adducts with the lead-halide precursor salts. These adduct-based precursor phases control nucleation and the growth of the polycrystalline domains. There has not yet been a comprehensive study comparing the various antisolvents used in different perovskite compositions containing cesium. In addition, there have been no reports of solvent engineering for high efficiency in all-inorganic perovskites such as CsPbI 3 . In this work, inorganic perovskite composition CsPbI 3 is specifically targeted and unique adducts formed between CsI and precursor solvents and antisolvents are found that have not been observed for other A-site cation salts. These CsI adducts control nucleation more so than the PbI 2 -dimethyl sulfoxide (DMSO) adduct and demonstrate how the A-site plays a significant role in crystallization. The use of methyl acetate (MeOAc) in this solvent engineering approach dictates crystallization through the formation of a CsI-MeOAc adduct and results in solar cells with a power conversion efficiency of 14.4%.

14 SOLAR ENERGY↗

Interplay of coulomb and exciton–phonon coupling controls singlet fission dynamics in two pentacene polymorphs

Pentacene is an important model organic semiconductor in both the singlet exciton fission (SF) and organic electronics communities. We have investigated the effect of changing crystal structure on the SF process, generating multiple triplet excitons from an initial singlet exciton, and subsequent triplet recombination. Unlike for similar organic semiconductors that have strong SF sensitive to polymorphism, we find almost no quantitative difference between the kinetics of triplet pair (TT) formation in the two dominant polymorphs of pentacene. Both pairwise dimer coupling and momentum-space crystal models predict much faster TT formation from the bright singlet excited state of the Bulk vs ThinFilm polymorph, contrasting with the experiment. GW and Bethe–Salpeter equation calculations, including exciton–phonon coupling, reveal that ultrafast phonon-driven transitions in the ThinFilm polymorph compensate the intrinsically slower purely Coulomb-mediated TT formation channel, rationalizing the similarity in observed rates. Taking into account the influence of subtle structural distinctions on both the direct and phonon-mediated SF pathways reveals a predictive capability to these methods, expected to be applicable to a wide variety of molecular crystals.

14 SOLAR ENERGY↗

Control of CuPt Ordering in GaInP Grown by Hydride Vapor Phase Epitaxy

We investigate the degree of ordering present in GaInP layers grown by dynamic hydride vapor phase epitaxy (D-HVPE) as a function of various growth conditions. We assess order parameter from both transmission electron and x-ray diffraction and compare these trends to the order parameter estimated by the photoluminescence-determined band gap in the GaInP layers. The degree of ordering increases with deposition temperature and the ratio of gas-phase group V to group III precursors in the reactor. We also investigate the effect of growth rate, demonstrating the capability of HVPE to suppress order through rapid growth rates. Such ordering dependences are consistent with mechanisms established for ordering observed in GaInP grown by organometallic vapor phase epitaxy (OMVPE), but with weaker ordering than GaInP grown by that method.

growth↗

Model, Design, and Control for Power Conversion in Wave Energy Converter System

Wave energy, if all been harvested along the U.S. coastline, can power around 65% of the energy consumption in U.S.. Comparing to other renewable energy sources like solar or wind, ocean wave can provide up to 90% of steady uptime. With the high energy density (2-3 kW/m 2 ), it can produce more energy with the same amount of installation area comparing to the energy density of wind turbine (0.6 kW/m 2 ) and solar panel(0.2 kW/m 2 ). The predictability of wave provides advantages like planning installation, power dispatching, and maintenance activities. Although with all these advantages, wave energy converter system is still in the research stage due to its high system cost per electricity production. One of the challenges that need to be solved is the irregularity from the wave motion that leads to high instantaneous peak power into the wave energy converter, which usually reaches up to 10 - 20 times of the average power. The high peak power will not only bring high mechanical/electrical stress but also result in an overrating design of the components in the system. Another obstacle that prevents the wave energy system from moving forward is the high testing cost from the validations in wave-energy-test sites or tank-test sites. A high-fidelity multi-disciplinary system model, including hydrodynamics, mechanical dynamics, electromagnetics, and power electronics, is needed to predict the behavior of the system and reduce the cost of design validation.

16 TIDAL AND WAVE POWER↗

Inertia estimation for power grids: A review of methods, challenges, and future prospects

The electric power grid is undergoing a significant transformation, shifting from traditional synchronous generators to inverter-based resources (IBRs) such as solar photovoltaics, wind turbines, and energy storage systems. This evolution leads to a reduction in system inertia, a critical attribute for maintaining frequency stability in response to disturbances. Consequently, the ability to monitor and estimate system inertia has become increasingly essential. This paper provides a comprehensive review of existing inertia estimation methodologies, analyzing them from multiple perspectives, including the types of data utilized, underlying estimation principles, operational modes, and system-wide applicability. A comparative summary table is included to distill commonalities and key characteristics across various studies. In addition, the paper examines practical implementations of inertia estimation across several major power systems worldwide, including the U.S. interconnections, the Nordic power system, and the U.K. grid. Key challenges are identified, particularly in estimating contributions from virtual inertia sources and load-induced inertia in increasingly converter-dominated networks. To address these emerging challenges, the paper proposes an integrated framework for real-time inertia estimation and monitoring. This framework encompasses critical components such as data acquisition, inertia estimation from both synchronous and non-synchronous sources, load-induced effects, optimization techniques, forecasting, and virtual inertia scheduling. Collectively, these elements enable dynamic, system-wide monitoring and adaptive control of grid inertia.

Inertia estimation↗

Design Power Control Strategies of Grid-Forming Inverters for Microgrid Application

This paper develops and compares two control schemes in the application control layer of a non-phase-locked loop (non-PLL) grid-forming (GFM) inverter to gain insight and understanding into how the two schemes affect the dynamic responses of GFM inverters and the transition operation of microgrids. The first scheme adopts power tracking based on an outer current loop in grid-connected mode and droop control in islanded mode, and the second uses droop control in both grid-connected and islanded modes. Analytical study is developed to compare the performance of these two strategies from various aspects, including fundamental differences, transition operation, power tracking, and P-Q capability with low point-of-common-coupling (PCC) voltages. Extensive simulation testing is carried out to validate the control performance of these two control strategies, and the simulation testing confirms the findings of the analytic study. Finally, the second strategy is recommended because of its superior control performance and ease of implementation. The analysis and results are useful in developing reliable control schemes for non-PLL GFM inverters because increasing numbers of inverters will work as non-PLL grid-forming sources in future grids because of their improved stability and reliability.

grid-forming↗

Enabling Cybersecurity, Situational Awareness and Resilience in Distribution Grids with High Penetration of Photovoltaics (CARE-PV) (Final Report)

Since legacy distribution systems have very limited visibility beyond the substation, high penetration of PV at the grid edge presents some unique operational challenges. One approach to address these challenges is to use information from advanced metering infrastructure (AMI) and µPMUs. However, exploiting this information is impacted by a number of factors, including multi-timescale measurements, volume of data generated, communication network impairments (e.g., information loss and latency) and susceptibility to cyber-attacks. Therefore, one of the critical tasks involved in the management of a distribution grid is to develop complete situational awareness by integrating cyber-security mechanisms with state estimation strategies and leveraging this situational awareness to assure energy services at strategic locations while exploiting AMI/PV inverter/ µPMU data. This CARE-PV project addresses the fundamental challenges in situational awareness and resilience to cyber and physical vectors by exploiting the synergy between innovative modeling, estimation, data analytics, testing and validation using smart PV inverters designed at K-State and facilities at NREL. Specifically, the project involved the development, testing and validation of the following novel enabling technologies: (Thrust 1) Resilience to cyber vectors that impact data integrity was addressed via a two-level defense strategy that combines cyber intrusion detection using self-learning, cooperative smart PV inverters, and a novel moving target defense framework to combat data integrity attacks. (Thrust 2) Resilience to cyber-physical vectors that impact situational awareness by limiting data availability was addressed via novel centralized and decentralized, sparsity-based static and dynamic state estimation approaches that enhance observability even when the underlying system is unobservable. (Thrust 3) Leveraging a unique probabilistic sensitivity analysis approach accompanied by one-of-a-kind dominant influencer set computation, the vulnerability of critical infrastructure at strategic locations was evaluated so that proactive PV-based control strategies can be used to support operations under normal/outage scenarios. These CARE-PV project innovations were demonstrated on both small-scale IEEE and larger utility-scale testbeds (Thrust 4). Feedback from Industry Advisory Board members was used to formulate a commercialization pathway for a subset of CARE-PV technologies. These CARE-PV technologies will ultimately lead to reliable and secure, large-scale integration of renewable energy and mitigate the risk of energy disruption resulting from cyber incidents and other emerging threats within the energy environment.

14 SOLAR ENERGY↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Feedback and Oscillations: Constructing Feedback Systems for Root Cause Analysis of Oscillations in Power Grids

Dynamic phenomena linked to inverter-based resources (IBRs) have gained global attention. Several IBR-induced dynamics have caused bulk power system-connected wind or solar power plants to trip, and some have even led to widespread outages. In addition, many oscillations have been observed involving IBR power plants. In 2023, the IEEE Power & Energy Society (PES) IBR Subsynchronous Oscillations (SSO) task force published a journal article, “Real-World Subsynchronous Oscillation Events in Power Grids With High Penetrations of Inverter-Based Resources,” in which 19 IBR oscillation events were examined for their causation. Earlier in 2020, another PES task force article, “Definition and Classification of Power System Stability-Revisited & Extended,” authored by prominent academics, introduced converter-driven stability as a new category of stability. The international power grid industry community also took action by publishing the CIGRE Green Book, Power System Dynamic Modelling and Analysis in Evolving Networks (led by Babak Badrzadeh and Zia Emin) in 2024. In August 2024, the Energy Systems Integration Group (ESIG) released a practical guide led by Nick Miller, “Diagnosis and Mitigation of Observed Oscillations in IBR-Dominant Power System: A Practical Guide.” The goal of the guide is to assist practicing engineers in making initial judgments and conducting detailed analyses about oscillations. Finally, when addressing the classification of stability and oscillations, the guide emphasizes a causality-based taxonomy for grouping, such as voltage control-induced oscillations, synchronization-induced oscillations, and frequency or active power control-induced oscillations.

Fan, Lingling [Univ. of South Florida, Tampa, FL (↗

Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems with Coupled and Full-Order Dynamics from Control Systems and Power Networks

The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. Here, in this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

14 SOLAR ENERGY↗