Spatially and temporally resolved H and OH densities in a nanosecond pulsed plasma jet: an analysis of the radical generation, transport, recombination and memory effects
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Electron beam (e-beam) treatment uses accelerated electrons to form oxidizing and reducing radicals when applied to water without the use of external chemicals. In this study, electron beam treatment was used to degrade 1,4-dioxane in several water matrices. Removal improved in the progressively cleaner water matrices and removals as high as 94% to 99% were observed at a dose of 2.3 kGy in secondary effluent. 1,4-dioxane removal was confirmed to be primarily through hydroxyl radical oxidation. The calculated electrical energy per order was found to be 0.53, 0.26, and 0.08 kWh/m 3 /order for secondary effluent (Avg. total organic carbon (TOC) 9.25 mg/L), granular activated carbon effluent (TOC 3.46 mg/L), and ultrapure water, respectively, with a 70% generation and transfer efficiency applied.
A modeling system to simulate fate and transport of contaminant plumes in groundwater beneath the Central Plateau to support the Cumulative Impact Evaluation (CIE) and Composite Analysis (CA) is being developed. The CIE will evaluate the cumulative effect of multiple Central Plateau radiological and chemical sources on groundwater quality (DOE/RL-2018-69, Cumulative Impact Evaluation Technical Approach Document ). This will enable cleanup decisions to be evaluated in the context of all Central Plateau waste sites and existing groundwater conditions. The CA evaluates the cumulative effect of all sources of radioactive materials on radiological dose to future members of the public (DOE/RL-2018-60, Annual Status Report (FY 2018): Composite Analysis of Low Level Waste Disposal in the Central Plateau of the Hanford Site ). Fate and transport modeling will be used to forecast future groundwater concentrations for both the CIE and CA. The CIE/CA subsurface modeling system is divided into source (inventory), vadose zone, and saturated zone facets. Source inventory is a necessary input to the vadose zone facet, and releases from the vadose zone to groundwater are inputs to the saturated zone facet. The vadose zone facet simulates historical and future releases from the vadose zone to groundwater for both liquid waste and solid waste disposal sites. Effluent release volumes and radionuclide inventory estimates for liquid waste sites are contained in ECFHANFORD- 17-0079, Hanford Soil Inventory Model (SIM-v2) Calculated Radionuclide Inventory of Direct Liquid Discharges to Soil in the Hanford Site’s 200 Areas , herein referred to as SIM-v2. The liquid waste sites in SIM-v2 include the 216-B-3 Pond near 200 East Area and the 216-U-10 Pond in 200 West Area. The 216-B-3 Pond system consisted of a main pond and 3 expansion lobes that were operational during overlapping time periods. It also included influent ditches, but these are not listed as liquid waste sources in SIM-v2 and are not included in the CIE/CA modeling. The total effluent volume released to the pond system was measured, but the partitioning of this volume to the various expansion lobes was not determined and is not accounted for in SIM-v2. Regarding the 216-U-10 Pond, it received water from several influent ditches. The pond and the influent ditches are listed as liquid waste sites in SIM-v2 and are included as sources in the CIE/CA modeling. Because water in the ditches flowed into the pond, only a portion of the effluent volumes and contaminant inventories assigned to the ditches in SIM-v2 infiltrated from the ditches. Thus, partitioning of infiltration and contaminant inventories between the ditches and the pond is not fully accounted for in SIM-v2. Further, some of the water in the 216-U-10 Pond entered overflow ditches and the amount of this overflow was not recorded and is not accounted for in SIM-v2. Thus, the purpose of this Environmental Calculation File (ECF) is to partition the infiltration of wastewater and contaminant inventory between the main pond and each expansion lobe of the 216-B-3 Pond system, and to partition the infiltration of wastewater and contaminant inventory between the ditches and pond of the 216-U-10 Pond system.
In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.
In order to limit and mitigate the environmental impacts associated with coal combustion, flue gas desulfurization (FGD) systems have been put into place to reduce the release of contaminates. The main constituent targeted by FGD systems is sulfur oxide gasses (SOx). While FGD systems have been able to achieve high removal rates of SOx gasses, the wastewater effluent requires treatment before release back into the environment. The release of wastewater is heavily regulated by the U.S. Environmental Protection Agency (EPA) and their effluent guideline limitations rule (ELG). The ELG rule set new limits on discharges containing constituents such as selenium, nitrogenous species, mercury, and arsenic in the effluent. This report seeks to give background on abiotic removal methods as well as highlight the most important issues when utilizing biological treatment to treat the FGD wastewater for the constituents of interest mentioned. This report also seeks to discuss the issues of foaming which can occur during biological treatment.
The A-01 wetland treatment system (WTS) was designed to remove metals from the effluent at the A-01 National Pollution Discharge Elimination System (NPDES) outfall at the Savannah River Site, Aiken, SC. The A-01 effluent flows from a retention basin to a splitter box, where it is distributed to four pairs of cells in series before discharge to a stream. Each treatment cell is a one-acre wetland that contains Schoenoplectus californicus (giant bulrush) and has a nominal 24-hour retention time. The purpose of this research was to investigate metal removal, distribution and retention in the A-01 WTS over a period of 20 years. During 20 years of operation, systematic water and sediment sampling validated the wetlands' performance. After passage through the treatment cells, Cu concentrations were well below permit limits (22 pg L -1 ) during all years of operation, often falling below 10 pg L -1 . Cu removal has been consistent over time, averaging about 80% despite large changes in influent Cu concentrations. Most divalent metals were rapidly removed from the water and held in the sediments shortly after the water entered the treatment wetlands. Average removal of Pb from water by the wetland system was 67 and 74%, respectively, in 2004, and 2020. Comparable values for Zn were 52 and 65%, respectively. Generally, the highest concentrations of Cu, Pb, and Zn were found in the sediment from the first cell in each pair of cells suggesting that most of the Cu, Pb, and Zn in the A-01 effluent was bound to the sediment quickly. Diffusive gradients in thin films (DGT) measurements of Cu and Zn in the sediments were much lower than bulk sediment concentrations. These results suggest that most of the Cu and Zn in the A-01 WTS sediments was not bioavailable, hence not toxic to aquatic organisms, as a likely consequence of adsorption to sediment particles and complexation with organic and inorganic substances.
At the time of this testing, the Low-Activity Waste Pretreatment System (LAWPS) was to provide for the initial production of immobilized low-activity waste by feeding Hanford tank supernate from tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Facility for immobilization. Washington River Protection Solutions requested that Hanford tank waste collected from tank 241-AP-107 (hereafter called AP-107) be processed using conceived pretreatment steps (suspended solids removal by filtration, Cs removal by ion exchange) then vitrified. A small-scale test platform to demonstrate the solids filtration, Cs removal, and LAW vitrification was constructed and installed at Pacific Northwest National Laboratory. Bench-scale ion exchange testing with approximately 9 L of AP-107 supernate was conducted using crystalline silicotitanate (CST) ion exchange media. The IONSIV R9140-B CST was provided by Honeywell UOP, LLC in 2018 (Batch 2081000057). The ion exchange media was first tested with simulant and was previously described. This report describes the Cs ion exchange batch contact and column test results with the AP-107 tank waste. Batch contact testing helps to evaluate CST performance on tank waste supernate prior to processing it in the ion exchange columns. Batch contacts were performed with the waste at four Cs concentrations at a phase ratio of 200 (liquid volume to exchanger mass) with AP-107. The distribution coefficient (K d ) at the equilibrium condition of 8.57 µg Cs/mL (AP-107 feed condition) was determined to be 669 mL AP-107/g CST. With a CST bed density of 1.00 g/mL, this K d corresponded to a predicted 50% Cs breakthrough of 669 bed volumes (BVs). The Cs load capacity at the equilibrium feed condition was determined to be 7.5 mg Cs/g dry CST. The column testing was prototypic to the intended LAWPS operations in a lead-lag column format, although on a small-scale basis with 10-mL CST beds. The feed was processed downflow through the lead column and then through the lag column at ~2.2 BV/h. Loading continued until the lag column reached the WTP waste acceptance criteria (WAC) for receiving supernatant waste for vitrification (a function of the Na and 137 Cs concentrations). For AP-107, the WAC is 0.114% of the influent 137 Cs concentration; this required a Cs decontamination factor of 876. The Cs effluent from the lag column reached the WAC after processing ~410 BVs. To keep the subsequent product effluent below the WAC, a replacement lag column was prepared, the lead column was removed from service (after processing a total of 471 BVs), the lag column was put into the lead column position, and the replacement lag column was installed. Feed processing continued and after another ~290 BVs the Cs effluent from the lag column again exceeded the WAC. In both cases, the lead columns only reached 25% Cs breakthrough before removal. Although 50% Cs breakthrough was not reached, this value was estimated and averaged based on extrapolation of the loading curves (640 BVs) and agreed within 4% of the predicted 50% Cs breakthrough from batch contact test results (669 BVs). Table ES.1 summarizes the observed column performance and relevant Cs loading characteristics.
Microplastics are commonly found near wastewater treatment facilities with the source originating typically from fibers associated with laundry detergents. Fourmile branch would have limited laundry associated effluent and does not receive any input from water originating from upstream industry sources, therefore microplastics would have originated from Site operations or through atmospheric deposition which are both unexplored pathways. In order to assess environmental inventory effects on the biota, water samples were collected from sampling locations along Fourmile Branch on the Savannah River Site using plankton nets and grab samples at Fourmile Branch locations (i.e., FM-2B, FM-A7, and FM6). Fourmile Branch has a long history of receiving industrial effluents from site operations as well effluent from the site’s wastewater treatment plant. Water samples and the debris collected in the nets were rinsed with deionized water and sieved to remove the larger fractions of plastics (4000-2000 µm) and retain fractions <500 µm. The water samples were analyzed for the type and size of plastics by μ-Raman, mass spectrometry, and Fourier Transform Infrared Spectroscopy (FTIR) methods. Previously collected bivalves were prepared into thin sections and analyzed using microscopy.
This U.S. Department of Energy/National Energy Technology Laboratory techno-economic analysis evaluates those parameters having the greatest performance and cost impact on wet flue gas desulfurization (FGD) effluent wastewater treatment systems, and air cooled condensers for dry cooling systems. Two supercritical pulverized coal power plants are considered: 1) an existing plant (modified for surface water discharge and air emissions consistent with limits for existing plants) retrofitted with wet FGD effluent wastewater treatment and 2) a greenfield plant constructed with an air-cooled condenser (ACC). Sensitivity analyses are completed on various process parameters associated with the wet FGD effluent wastewater treatment system and ACC to determine the impact on the net plant efficiency and levelized cost of electricity (LCOE). Research and development targets are recommended for the parameters shown to have the greatest potential impact on cost or performance.
The Treated Effluent Disposal Facility (TEDF) is a site where treated non-hazardous and non-radioactive liquid wastes are collected and disposed of in two state-permitted disposal basins near the 200 East Area at the Hanford Site. In 2016, a renewal application was submitted for TEDF that requested mass loading effluent limits instead of concentration-based effluent limits. The Washington State Department of Ecology denied this request due to a lack of groundwater monitoring wells that can be used to identify and characterize the impact of TEDF discharges on the underlying groundwater. Current TEDF monitoring wells are screened in the confined aquifer below the Ringold Lower Mud (RLM) unit and are not representative of TEDF discharges that can potentially mound above the RLM unit.
Savannah River National Laboratory has identified a magnesium oxysulfate grout formulation to solidify the liquid effluent from the Savannah River Plutonium Processing Facility (SRPPF) Aqueous Recovery System (ARS). The formulation uses reactive, light burnt MgO, anhydrous MgSO 4 , and dead burnt MgO and provides good mixability, similar density to the original Portland Cement-based mix, and a leachate pH of 9.39, within the assumed Waste Isolation Pilot Plant (WIPP) brine pH range. The formulation will solidify the effluent using a solid first, lost paddle design, within a 55-gallon drum. A series of seven different process disruptions, or irregular processing during the expected ARS liquid effluent solidification process, were completed to assess the severity of the impact of the process disruption and how the formulation behaves under these conditions. Seven process disruptions were investigated including: No Mixing, Partial Mixing, Compacted/Stratified, Sealed, Overfilled, Underfilled, and Undermixed. The impact on solidification, leachate pH, Er (a Pu/Am surrogate) distribution, and density of the resulting grout were established. Overall, four of the process disruptions, No Mixing, Partial Mixing, Compacted/Stratified, and Overfilled, resulted in basic, unabsorbed liquid that would require additional solidification to be acceptable for WIPP. Most solids generated in this testing met the expected WIPP leachate pH requirements. Solids from the Compacted/Stratified process disruption test, however, produced a leachate pH slightly above the assumed range in the WIPP performance assessment. The distribution of Er for most of the tests was relatively consistent. The No Mixing process disruption test, however, resulted in non-homogeneous Er distribution, indicating that radioactive material would not be evenly distributed throughout this solid’s matrix. The Overfilled test is the only mix with a density slightly below the acceptable value. The Sealed and Overmixed tests produced a solid closest to the standard mix with no unabsorbed liquid, expected leachate pH levels, consistent Er concentrations, and expected density, indicating these process disruptions do not have a negative impact on the final grout form. Based on the other process disruptions, it is critical to have premixed dry materials and a well-defined mixing process to produce a solid, homogeneous magnesium oxysulfate cement, with no unabsorbed liquid. These process disruption tests show that the lack of adequate mixing is fundamental to creating an improperly solidified material that may require remediation.
This research explored vitrification of U-Zr nuclear fuel that exhibits an explosion hazard when processed by common nitric acid dissolution. Glass frits were chosen based on properties that had been previously measured as well as being demonstrated successfully in production at the Defense Waste Process Facility (DWPF). Zirconium and Aluminum metal powders were chosen to represent the spent fuels after literature demonstrated that the potential phase that causes the issue for explosive reaction in the effluent stream is tied to the Zirconium-III phase field. DSC measurements were carried out on various simulants and waste forms to better understand thermal behavior of these materials. Zirconium (Zr) was tested with both nitric acid and the new effluent flowsheet that is under development by the SRNL Chemical Process Control (CPC) group. The nitric acid test did show the expected exothermic behavior as well as how the behavior is affected by particle size of the powders used. In contrast, the effluent samples did not show an exothermic peak. However, the concentration of metal in the samples was orders of magnitude lower than in the nitric acid testing and further testing of the effect of concentration on the exothermicity that could be measured confirmed a dampened signal. Tests were run that included frit, both DWPF Frit 510 and Iron Phosphate frit, exhibiting complex curves that included multiple endothermic and exothermic peaks during heating and cooling. The final crucible samples appear similarly to the bulk glasses pointing to these peaks being a part of the dissolution of the simulant into the base glasses.
Tests were conducted on a DM10 vitrification system with prototypical off-gas treatment system, which includes an SBS, WESP, and evaporator based on the design of the evaporator to be installed at the WTP for concentration of the liquid effluents. This allowed determination of the partitioning and speciation of iodine between the melter and the off gas system components, including liquid effluents from the SBS and WESP as well as in the evaporator condensate and concentrate. Evaporator testing was decoupled from melter testing to permit filtration and pH adjustments of process solutions prior to evaporation. In addition, a slip stream was pulled from the exhaust downstream of the WESP and High-Efficiency Particulate Air (HEPA) filters and passed through a caustic scrubber simulating the WTP caustic scrubber to assess iodine partitioning to the caustic scrubber liquid effluent. The tests were conducted using simulated Hanford LAW from tank AP-107, which is the planned first feed for Direct Feed LAW (DFLAW) operations, at a nominal feed concentration of 5.6 molar Na over about 120 hours of testing.
Microalgae-based tertiary wastewater treatment has the potential to meet stringent effluent phosphorus limits, with the added benefit of producing a marketable feedstock. However, the lack of validated mechanistic models and their implementation in process simulators have limited the adoption of this technology. In this study, an updated lumped pathway metabolic model (Phototrophic-Mixotrophic Process Model, PM 2 ), including both photoautotrophic and heterotrophic metabolisms of microalgae, was developed to predict effluent phosphorus concentration and biomass yield in response to dynamic influent and varying environmental conditions. The model was implemented in QSDsan – an open-source, Python-based design and simulation platform – for robust simulation under uncertainty. A global sensitivity analysis was performed to prioritize model parameters for calibration. The model was then calibrated and validated using batch experimental data and 45 days of continuous online monitoring data from a full-scale (568 m 3 ·d -1 ) microalgae-based tertiary wastewater treatment plant (EcoRecover process). In particular, along with dynamic influent composition, temperature and light intensity data with diel variation were provided as model inputs to reflect the microalgal behavior under day-night cycling. Overall, the QSDsan-based microalgae process simulator was able to predict effluent phosphorus within 0.02–0.04 mg-P·L -1 , while also capturing the general trends of state variables according to nutrient availability.
Exhaust flow contamination aspects of the biowaste resistojet are studied by evaluating effects of operating pressure, temperature and composition. Biowaste propellant mixtures considered are comprised of: (1) The Sabatier reactor effluent; (2) the effluent of the cabin carbon dioxide molecular sieve; and (3) water and water vapor from various sources. Results show that plume shapes of resistojet thrusters in the 25 to 100 mlb range exhibit greater apex angles for a given density contour than a scaled inviscid jet. Operation at low thrust, low pressure and high temperature accentuates this pluming due to viscous effects in the nozzle flow. Since the biowaste resistojet effluent is traveling at high velocity in the plume away from the aircraft it is found to be a superior method of damping than the ambient venting.
The dynamic behavior of neutral gases emitted from lunar surface sources is investigated. Pressure transients to be expected from several types of possible lunar surface sources are constructed. An approximate method is developed to estimate the source-sensor separation distance and the amount of effluent release. The case for which the source location and effluent molecular weight can be determined from ancillary data is discussed. It is shown that, if such data are available, pressure transients detected by either Apollo lunar surface experiment package ion spectrometers or cold cathode gages can be used to determine the release rate and the total amount of effluent release from the source.
A method was developed to quantitatively delineate waste concentrations throughout waste effluent mixing zones on the basis of densitometric measurements extracted from aerial photography. A mixing zone is the extent of a receiving water body ultilized to dilute a waste discharge to a concentration characteristic of a totally mixed condition. Simultaneously-acquired color infrared photography and suspended solids water samples were used to quantitatively delineate the mixing zone resulting from the discharge of a paper mill effluent. Digital scanning microdensitometer data was used to estimate and delineate suspended solids concentrations on the basis of a semi-empirical model. Photographic photometry, when predicated on a limited amount of ground sampling, can measure and delineate mixing zone waste distributions in more detail then conventional surface measuring techniques. The method has direct application to: (1) the establishment of definite and rational water quality guidelines; (2) the development of sampling and surveillance programs for use by governmental and private agencies; and (3) the development of design and location criteria for industrial and municipal waste effluent outfalls.
Effluent concentration distributions from the waste water discharge of the Kraft Division Mill, Consolidated Paper Company, into the Wisconsin River at Wisconsin Rapids, Wisconsin, is investigated. Effluent concentrations were determined from measurements of the temperature distribution, using temperature as a tracer. Measurements of the velocity distribution in the vicinity of the outfall were also made. Due to limitations in the extent of the field observations, the analysis and comparison of the measurements is limited to the region within about 300 feet from the outfall. Effects of outfall submergence, of buoyancy and momentum of the effluent and of the pattern and magnitude of river currents on these characteristics are considered.