Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical system integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Optimal Economic Dispatch and Load-Following Strategies for Nuclear Integrated Energy Systems

The need for distributed and adaptable energy resources that can handle the growing unpredictability in both supply and demand is rising as the power system continues to modernize. In order to satisfy those needs and maintain grid resilience, nuclear power plants can dynamically control their output, despite typically being used as baseload generators. By incorporating energy storage and renewable energy sources, nuclear integrated energy systems are designed to satisfy the electrical and thermal demands of different end-user applications while ensuring flexible power operation. These systems generate revenue by participating in both wholesale and ancillary services electricity markets, as well as commodity markets for various byproducts generated from coupled industrial processes. This study addresses the economic dispatch efficiency of a tightly coupled nuclear integrated energy system comprising a gigawatt-scale light water reactor, commercialized in the U.S., a high-temperature steam electrolysis unit, a district heating network, and specified electrical loads. To demonstrate the nuclear power plant’s flexibility within the day-ahead unit commitment and economic dispatch framework, while maintaining equilibrium even during periods of refueling outages, this paper develops a mixed-integer linear programming framework that models the subsystems and components of its nuclear steam supply system. A systematic comparative analysis of flexible versus baseload nuclear power plant operation under varying levels of renewable energy integration indicates that flexible operation enhances system profitability by more than 18% while also increasing energy storage utilization, improving reactor responsiveness to load fluctuations, and allowing for greater participation across numerous electricity markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Interoperability Maturity Roadmap Methodology, V1.3

The Interoperability Roadmap Methodology document supports the U.S. Department of Energy (DOE) Grid Modernization Laboratory Consortium (GMLC) Interoperability Project’s efforts to advance interoperability as an essential component for the successful and more seamless integration of intelligent, communicating technologies into the electric power system. This proposed methodology supports the strategic approach to advance interoperability described in the GMLC Interoperability Project’s Interoperability Strategic Vision: Enabling an Interactive Grid. That document proposes engaging an ecosystem of businesses interested in integrating smart technology with the electric power system to develop an interoperability roadmap using a methodical approach. This roadmap methodology is to be applied to technology integration ecosystems (e.g., electric vehicles, photovoltaic inverters, or automated buildings), using tools that measure the state of interoperability today, to identify the gaps and challenges that can be overcome to improve interoperability, and thereby, simplify the integration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NASA Electric Aircraft Testbed (NEAT) Single-Aisle Transport Air Vehicle Hybrid Electric Tail-Cone Thruster Powertrain Configuration and Test Results

A key technical challenge is to establish a viable concept for a MW-class hybrid gas-electric propulsion system for a commercial transport aircraft. This includes developing aircraft propulsion system conceptual designs, integrating sub-systems, high efficiency/power density electric machines, flight-weight power system and electronics, and enabling materials in high voltage insulation, high frequency soft magnetics, and conductors. The primary benefit of this research is to diversify the current turbofan propulsion options to include hybrid electric propulsion elements that reduce energy usage, emissions, and noise. A reconfigurable powertrain testbed at NASA Glenn Research Center is described including test results from the initial 500 kW powertrain configuration.

Dyson, Rodger W.↗

NASA Electric Aircraft Testbed Single-Aisle Transport Air Vehicle Hybrid Electric Tail-Cone Thruster Powertrain Configuration and Test Results

A key technical challenge is to establish a viable concept for a MW-class hybrid gas-electric propulsion system for a commercial transport aircraft. This includes developing aircraft propulsion system conceptual designs, integrating sub-systems, high efficiency/power density electric machines, flight-weight power system and electronics, and enabling materials in high voltage insulation, high frequency soft magnetics, and conductors. The primary benefit of this research is to diversify the current turbofan propulsion options to include hybrid electric propulsion elements that reduce energy usage, emissions, and noise.

Dyson, Rodger↗

EV Load Forecasting Guide: A Report by the Energy Systems Integration Group’s EV Load Forecasting Task Force

Forecasting electricity usage is a foundational planning activity for utilities, underpinning billions of dollars in grid investments that ensure system reliability. Historically, forecasting relied on trends in economic and population growth; however, transportation electrification presents a new and complex planning challenge. Unlike conventional loads, electric vehicle (EV) charging has relatively limited usage history. In addition, charging is driven by complex human behaviors, is mobile, and at the same time can concentrate geographically in ways that, without proper planning, can quickly overwhelm local distribution systems.

Giraldez, Julieta [Electric Power Engineers, Austi↗

Cybersecurity Risk Profiles for Distributed Energy Resource Management Systems

Managing the digitalization of increasingly diversity energy resources is a complex challenge for energy systems planners and managers. As the penetration of solar photovoltaics (PV) and other distributed renewable energy resources (DERs) expands, distributed energy resource management systems (DERMS) will play an increasingly important role in managing, monitoring, and controlling DERs as electric systems before more distributed, interconnected, and networked. However, the cybersecurity implications of DERMS deployments are not well understood today. A lack of understanding around the cybersecurity implications of DERMS deployments and variability in the security posture of DERMS vendors, owners, and operators could introduce new security risks to evolving electric power systems. This paper describes cybersecurity attack scenarios on DERMS, identifies related cybersecurity standards and guidelines, reviews the security features of state-of-the-art DERMS solutions, and offers cybersecurity guidance for DERMS vendors, owners, and operators to protect DERMS' unique capabilities. Standardizing cybersecurity requirements for DERMS could help improve the security of DERMS integrations and improve innovations that are more secure by design. The cybersecurity guidance found in this paper is intended to offer a unified approach and lay the foundation for future standardization of DERMS cybersecurity to reduce risk to the solar industry and other renewable energy stakeholders when integrating these technologies with electric power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An integrated and modular digital modeling approach for the space station electrical power system development

An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.

Gombos, Frank J.↗

An integrated and modular digital modeling approach for the Space Station electrical power system development

An electrical power system for the Space Station was designed, developed and built. This system provides for electrical power generation, conditioning, storage, and distribution. The initial configuration uses photovoltaic power generation. The power system control is based on a hierarchical architecture to support the requirements of automation. In the preliminary design and technology development phase of the program, various modeling techniques and software tools were evaluated for the purpose of meeting the Space Station power system modeling requirements. Rocketdyne and LeRC jointly selected the EASY5 simulation software, developed by Boeing Computer Services, as a system level modeling tool. The application of the selected analytical modeling approach to represent the entire power system is described. Typical results of model predictions are also summarized. The equipment modeled includes solar arrays, dc to ac converters, resonant inverters, battery storage system, alternator, transmission line, switch gear, and system level microprocessor controls. During the advanced development phase of this program, several models were developed using this approach.

Gombos, Frank J.↗

The SPACE Computer Code for Analyzing the International Space Station Electrical Power System: Past, Present, and Future

The System Power Analysis for Capability Evaluation (SPACE) computer code was initially developed by NASA in 1988 to assess the Space Station Freedom electric power system and later adapted to support contractor electrical power system capability analyses for the International Space Station (ISS). Over time, the code has supported many efforts such as ISS redesign activities in the early 1990s, assessment of time-phased loads against power system operating limits for future ISS assembly flights (including Certification of Flight Readiness reviews by the ISS program office), and determining the optimum solar array gimbal positions while respecting keep-out zones which minimize both solar array contamination and structural loads. The code has been validated by comparisons with ISS on-orbit data in multiple validation episodes. Recent updates to the code include the incorporation of a Lithium-Ion battery model in addition to the Nickel Hydrogen battery model and modifications to the solar array degradation model to better match on-orbit test results. SPACE has also been extended beyond the ISS to include modeling of the Orion Multi-Purpose Crew Vehicle electrical power system (SPACE-MPCV) and Mars Surface Electrical Power Systems (MSEPS). Portions of SPACE were integrated with a trajectory code to form a Solar Electric Propulsion Simulation (SEPSim), which can be used for analyzing solar electric propulsion missions. In addition, SPACE methods and subroutines have been adapted to a multitude of other projects. This paper summarizes the initial code development and subsequent code utilization in the context of the overall ISS program development and on-orbit operations. Recent updates and results from the code are discussed, including preliminary analyses for the Orion power system.

Electrical Power System↗

Integrated propulsion for near-Earth space missions. Volume 1: Executive summary

Tradeoffs between electric propulsion system mass ratio and transfer time from LEO to GEO were conducted parametrically for various thruster efficiency, specific impulse, and other propulsion parameters. A computer model was developed for performing orbit transfer calculations which included the effects of aerodynamic drag, radiation degradation, and occultation. The tradeoff results showed that thruster technology areas for integrated propulsion should be directed towards improving primary thruster efficiency in the range from 1500 to 2500 seconds, and be continued towards reducing specific mass. Comparison of auxiliary propulsion systems showed large total propellant mass savings with integrated electric auxiliary propulsion. Stationkeeping is the most demanding on orbit propulsion requirement. At area densities above 0.5 sq m/kg, East-West stationkeeping requirements from solar pressure exceed North-South stationkeeping requirements from gravitational forces. A solar array pointing strategy was developed to minimize the effects of atmospheric drag at low altitude, enabling electric propulsion to initiate orbit transfer at Shuttle's maximum cargo carrying altitude. Gravity gradient torques are used during ascent to sustain the spacecraft roll motion required for optimum solar array illumination. A near optimum cover glass thickness of 6 mils was established for LEO to GEO transfer.

Dailey, C. L.↗

Do agrivoltaics improve public support for solar? A survey on perceptions, preferences, and priorities

Abstract Agrivoltaic systems integrate agricultural production with solar photovoltaic electricity generation. Given the proven technical, economic, and environmental co-benefits provided by agrivoltaic systems, increased proliferation is anticipated, which necessitates accounting for the nuances of community resistance to solar development on farmland and identifying pathways for mitigation. Minimizing siting conflict and addressing agricultural communities’ concerns will be key in continued deployment of agrivoltaics, as localized acceptance of solar is a critical determinant of project success. This survey study assessed if public support for solar development increases when energy and agricultural production are combined in an agrivoltaic system. Results show that 81.8% of respondents would be more likely to support solar development in their community if it integrated agricultural production. This increase in support for solar given the agrivoltaic approach highlights a development strategy that can improve local social acceptance and the deployment rate of solar. Survey respondents prefer agrivoltaic projects that a) are designed to provide economic opportunities for farmers and the local community b) are not located on public property c) do not threaten local interests and d) ensure fair distribution of economic benefits. Proactively identifying what the public perceives as opportunities and concerns related to agrivoltaic development can help improve the design, business model, and siting of systems in the U.S.

Pascaris, Alexis S. (ORCID:0000000253806927)↗

Distributed photovoltaic systems: Utility interface issues and their present status

Major technical issues involving the integration of distributed photovoltaics (PV) into electric utility systems are defined and their impacts are described quantitatively. An extensive literature search, interviews, and analysis yielded information about the work in progress and highlighted problem areas in which additional work and research are needed. The findings from the literature search were used to determine whether satisfactory solutions to the problems exist or whether satisfactory approaches to a solution are underway. It was discovered that very few standards, specifications, or guidelines currently exist that will aid industry in integrating PV into the utility system. Specific areas of concern identified are: (1) protection, (2) stability, (3) system unbalance, (4) voltage regulation and reactive power requirements, (5) harmonics, (6) utility operations, (7) safety, (8) metering, and (9) distribution system planning and design.

Hassan, M.↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Production of Fischer-Tropsch Synfuels at Nuclear Plants

A case study analysis was performed to evaluate nuclear-powered synthetic fuel production in the midwestern United States (U.S.). A Fischer-Tropsch (FT) fuel synthesis plant design was used as the basis for the analysis. The FT plant design was configured to produce a product slate consisting of diesel fuel, jet fuel, and motor gasoline blend stocks from carbon dioxide (CO 2 ) and hydrogen (H 2 ) feedstocks. The CO 2 feedstock for the FT plant was assumed to be sourced from biorefineries in the region around a Midwest light water reactor (LWR) nuclear power plant (NPP). The analysis specifies that power from the LWR is used to produce H 2 via high-temperature steam electrolysis and to operate the FT synfuel production plant. Capital costs were estimated for the FT plant while capital costs for the electrolysis plant were based on previous Idaho National Laboratory (INL) studies. In addition to labor and maintenance costs for the FT and electrolysis plants, operating costs also include the costs for CO 2 feedstock transport. An analysis was performed to determine the cost of transporting CO 2 from the distributed biorefinery sources to the centralized fuel synthesis plant as a function of the synfuel plant capacity and corresponding CO 2 demand. The primary revenue streams are associated with sales of the synthetic fuel products. The synthetic fuel products will likely follow the same market trends as the conventional fuel products. The synfuel price data was thus based on projections made by the U.S. Energy Information Administration (EIA) 2021 Annual Energy Outlook (AEO) for conventional fuel products minus federal and state taxes, as well as marketing and distribution costs. The economic analysis also considered cases that included and excluded revenues from the 2022 Inflation Reduction Act (IRA) clean hydrogen production tax credit (PTC) of $\$ $3.00/kg for the first ten years of operation. The economic analysis calculated the net present value (NPV) for cases involving steady-state synfuel production for comparison with the NPV for a business-as-usual case in which NPP continues to sell only electric power to the grid. A synfuel production “Reference Case” was considered in addition to sensitivity cases in which the plant capacity, electricity price, and synthetic fuel product prices were perturbed. The synfuel production Reference Case considered a scenario in which the electrolysis and synfuel plants utilized a combined electrical load of 1000 megawatt electrical (MWe) from the LWR with the balance of the LWR power output being sold to the electric grid. The economic analysis suggests that the synfuel production Reference Case evaluated in this analysis would lead to considerable economic potential for near-term deployment of a nuclear-based synfuel production plant. Specifically, the economic analysis suggests that the deployment of a 1000 megawatt (MW) nuclear-powered synfuel plant could result in a NPV increase of approximately $\$ $1.7 billion for a case with no clean synfuel price premium relative to conventional petroleum fuels when accounting for the additional revenues from the 2022 IRA clean hydrogen PTCs of $\$ $3/kg. Sensitivity analysis was performed to evaluate the effect of perturbation of selected model input parameters on the NPV for the synfuel production Reference Case. The sensitivity analysis indicates that the plant capacity has the largest impact on the differential NPV, with a smaller synfuel production capacity resulting in a decrease in revenue when a larger fraction of the power from the NPP is sold to the grid and a smaller fraction of the power is used to produce synthetic fuel products. The synfuel product pricing has the next largest impact on the differential NPV, with lower synfuel prices resulting in decreased NPV from decreased synfuel sales revenue while higher synfuel prices result in increased NPV from increased synfuel sales revenue. Electricity pricing has a smaller effect on the NPV than the fuel sales price since, in the Reference Case, most of the energy from the NPP is used for synfuel production and a smaller amount of the system revenues are associated with electrical power sales. However, the electricity price sensitivity does indicate that the Synfuel Integrated Energy System (IES) would have a greater NPV than the business-as-usual case (e.g., grid power sales only) when electricity market prices are low, suggesting that synfuel production could provide a strategy for decreasing the economic risks to NPPs posed by a loss of revenues attributed to falling electricity market prices.

10 SYNTHETIC FUELS↗

Comparison of fuel-cell and diesel integrated energy systems and a conventional system for a 500-unit apartment

The electrical and thermal energy utilization efficiencies of a 500 unit apartment complex are analyzed and compared for each of three energy supply systems. Two on-site integrated energy systems, one powered by diesel engines and the other by phosphoric-acid fuel cells were compared with a conventional system which uses purchased electricity and on-site boilers for heating. All fuels consumed on-site are clean, synthetic fuels (distillate fuel oil or pipeline quality gas) derived from coal. Purchased electricity was generated from coal at a central station utility. The relative energy consumption and economics of the three systems are analyzed and compared.

Simons, S. N.↗

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Developing a Reduced 240-Bus WECC Dynamic Model for Frequency Response Study of High Renewable Integration

The ongoing changes in the generation resource mix, driven by the rapid adoption of inverter-based resources (IBR) as well as the early retirement of synchronous generators, are bringing new challenges to the planning and operation of bulk electric power systems. Consequently, there is an increasing need to understand, design, and quantify the reliability service provision from IBRs by performing integrated scheduling and dynamic simulations. However, test systems that have consistent scheduling and dynamic models rarely exist largely because of the decoupled nature of the two simulations on a synchronous generator-dominated system. This paper develops the dynamic model of a reduced Western Electricity Coordinating Council (WECC) system. In conjunction with the existing scheduling model, it is suitable for integrating scheduling and dynamic simulations. The reduced 240-bus WECC model reflects the generation resource mix of the Western Interconnection as of 2018. Moreover, the developed dynamic model is validated against field frequency events measured by FNET/GridEye and preserves the dominant inter-area oscillation mode in WECC.

dynamic simulation↗