Search NASA⌕ Search

SEARCH · Search NASA

Results for “electricity storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Policy implications of net-zero emissions: A multi-model analysis of United States emissions and energy system impacts

Many countries, subnational jurisdictions, and companies are setting net-zero emissions goals; however, questions remain about strategies to reach these targets, policy measures, technology gaps, and economic impacts. Here, we investigate the potential policy implications of reaching economy-wide net-zero CO 2 emissions across the United States by 2050 using results from a multi-model comparison with 14 energy-economic models. Model results suggest that achieving net-zero CO 2 targets depends on policies that accelerate deployment of zero- and low-emitting technologies that have seen rapid cost reductions in recent years (including wind, solar, battery storage, and electric vehicles) as well as relatively nascent options (including carbon capture and storage, advanced biofuels, low-carbon hydrogen, advanced nuclear, and long-duration energy storage). While net-zero policies are likely to lower fossil fuel consumption, including considerable coal and petroleum reductions, achieving net-zero emissions does not necessarily mean phasing out all fossil fuels. Model results indicate that the Inflation Reduction Act’s energy and climate provisions amplify near-term decarbonization but that net-zero policies have larger impacts on long-run outcomes. Stringent climate policy can have large fiscal impacts on tax revenue and government spending—revenues from carbon pricing and subsidies for carbon removal range from 0.1 % to 3.7 % of GDP in 2050 across models. Each dollar per metric ton carbon price leads to a 0.06 % to 0.31 % reduction in economy-wide CO 2 emissions relative to a reference scenario with current policies. Spending on energy across the economy decreases relative to today for many models under reference and net-zero policies, especially as a share of GDP, due primarily to end-use electrification and energy efficiency.

54 ENVIRONMENTAL SCIENCES↗

Durian-Inspired Design of Bismuth–Antimony Alloy Arrays for Robust Sodium Storage

Sodium-ion batteries have attracted widespread attention for cost-effective and large-scale electric energy storage. However, their practical deployment has been largely retarded by the lack of choice of efficient anode materials featuring large capacity and electrochemical stability and robustness. Herein, we report a durian-inspired design and template-free fabrication of a robust sodium anode based on triangular pyramid arrays of Bi 0.75 Sb 0.25 alloy electrodeposited on Cu substrates. The Bi 0.75 Sb 0.25 arrays exhibit an appreciable electrochemical robustness for sodium storage, sustaining a reversible capability 335 mAh g –1 at a high rate of 2.5 A g –1 and 87% of the initial capacity over 2000 cycles. We further demonstrate the applicability of the Bi 0.75 Sb 0.25 array anode in sodium full cells by pairing it with a Na 3 V 2 (PO 4 ) 3 /C cathode. This full cell achieves a high specific energy of 203 Wh kg –1 (based on both active electrodes). Such an enhanced performance is attributed to the thorny-durian-like architecture and bimetallic alloy composition. In conclusion, the pyramid tip induces ion enrichment for rapid charge-transfer reaction, while the alloy design reduces the electrode volume swelling for stable Na cycling.

25 ENERGY STORAGE↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage

The energy system infrastructure that delivers power to a building's loads needs to be resilient to withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Resilience Metrics for Building-Level Electrical Distribution Systems with Energy Storage: Preprint

The energy system infrastructure that delivers power to a building's loads needs to be resilient, such that it can withstand and recover from extreme outages (e.g., grid faults that leave millions of people without power during severe weather events). Building-level electrical distribution systems (BEDSs) distribute power from a building's energy sources - including the grid, solar photovoltaic (PV) panels, and batteries - to its loads, including lighting, HVAC, and plug loads. BEDS with storage can provide resilience by distributing local electricity supply to critical loads during an outage. Quantitative metrics are needed to assess the resilience improvements associated with new BEDS and storage system technologies. In this paper, we apply an existing metric, the probability of outage survival curve (POSC), to BEDS with storage and propose a set of novel metrics that improve upon POSC. Through a simulation-based case study, we demonstrate how these metrics are impacted by the BEDS design and how they can be used to design a resilient system.

buildings↗

Value of Geothermal Energy Storage for Supply-Side and Demand-Side Applications

This report presents the results of a study examining the value potential for geothermal energy storage (GES), a long-duration energy storage resource that stores thermal and/or geomechanical energy in the subsurface. GES could benefit the overall U.S. power system by temporally shifting electricity generation (supply-side) or meeting building heating and cooling load (demand-side). This report analyzes supply-side and demand-side opportunities independently because of differences in applications and models. Currently there is significant uncertainty about the development costs for GES, with only a limited number of demonstration plants for electric energy storage and building heating and cooling storage developments. In this report, we estimate the value of supply-side and demand-side GES to the bulk power system in the contiguous United States. Because of the significant uncertainty about GES development costs, this analysis does not consider GES deployment costs but instead focuses on the value of GES to the U.S. electricity system. The estimated values of GES provide reference points for economically competitive commercial cost targets. Supply-side GES is modeled as part of an enhanced geothermal system (EGS) generation plant in NREL's Regional Energy Deployment System (ReEDS) capacity expansion model (Ho et al. 2021). In contrast to conventional geothermal plants, which generate constant power, EGS plants have unique features that may allow for in-reservoir energy storage for flexible generation. Demand-side GES for heating and cooling, including seasonal hot and cold storage and short-duration heat pump storage, is incorporated into a price-taker model using Cambium electricity marginal cost projections. To establish an upper bound for the value of GES, analysis focused on favorable scenarios for storage with high generation from zero marginal cost, variable renewable energy resources. High penetrations of variable renewable energy generation can increase hourly electricity price variability, which increases the value of temporal energy arbitrage for storage technologies like GES.

15 GEOTHERMAL ENERGY↗

Switchable Charge Storage Mechanism via in Situ Activation of MXene Enables High Capacitance and Stability in Aqueous Electrolytes

The need for reliable renewable energy storage devices has become increasingly important. However, the performance of current electrochemical energy storage devices is limited by either low energy or power densities and short lifespans. Herein, we report the synthesis and characterization of multilayer Ti 4 N 3 T x MXene in various aqueous electrolytes. We demonstrate that Ti 4 N 3 T x can be electrochemically activated through continuous cation intercalation over a 10 day period using cyclic voltammetry. A wide operating window of 2 V is maintained throughout activation. After activation, capacitance at 2 mV s -1 increases by 300%, 140%, and 500% in 1 M H2SO4, 1 M MgSO4, and 1 M KOH, respectively, while maintaining ~600 F g -1 at 2 mV s–1 after 50000 cycles in 1 M H 2 SO 4 . This activation process is possibly attributed to the unique morphology of the multilayered material, allowing cation intercalation to increase access to redox-active sites between layers. This work adds to the growing repository of electrochemically stable MXenes reported for aqueous energy storage applications. These findings offer a reliable option for reliable energy storage devices with potential applications in large-scale grid storage and electric vehicles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Compressors for CO2-Based Power Cycles and Energy

Pumped thermal energy storage (PTES) is a cost-effective method for grid-scale, long-duration electrical energy storage (LDES). PTES uses a heat pump cycle to transfer thermal energy from a low temperature reservoir (LTR) to a high temperature reservoir (HTR), later using a heat engine cycle to reverse the process. A key component of the PTES system, the heat pump compressor, represents a significant driver to the cost, performance and operating characteristics of the PTES system. For grid-scale charging (>100 MW), traditional compressor scaling charts indicate that the operating conditions needed would be best served by a multistage axial compressor. While frame gas turbine compressors at these power ratings exist and operate at higher pressure ratios than needed for the CO2 PTES system, the inlet pressure and fluid density of this application exceed experience values. A conceptual design of a large-scale CO2 axial compressor was completed, including mean-line estimates of the compressor performance at full power conditions. The results of the conceptual design were used to refine the PTES cycle design, and updated operating conditions provided for further aero design optimization. A roughly one third scale of the first three stages of the 100 MW compressor was designed, built, and tested at relevant PTES charging conditions. Results of this test program are compared against high-resolution computational fluid dynamics models.

Compressor Heat↗

Future energy infrastructure, energy platform and energy storage

Today fossil energy dominates energy consumption across the world. There has been an increasing momentum to reduce fossil energy consumption and increase renewable energy utilization to more than 70%. Such high penetrations of distributed renewable resources bring large uncertainty and complexity that cannot be easily handled by the current infrastructure. For the last two decades, telecommunication industry has gone through a similar transition from centralized to distributed systems, and more recently to platform approaches, which become the corner stone of today’s vibrant platform economy. Based on telecommunication history, we believe that a platform-based approach, called the energy platform, is a viable solution for addressing the renewable energy challenges. The energy platform consists of an array of computational algorithms, sensing and control technologies for key industry, energy generators and users to jointly manage and control the complex energy infrastructure. It includes the following key components: (1) the hardware and software to generate, store, control and transmit electricity/data (the energy cloud), (2) the digital platforms and tools for key energy producers, digital, service and communication industry to share the assets, participate in and manage the complex infrastructure, and for customers to participate in energy transactions, (3) the transaction platform for new service and business models. Additionally, the energy platform requires breakthroughs in large scale energy storage and many other areas including efficient power electronics, sensors and controls, new mathematical and computational tools, and deep integration of energy technologies and information sciences to control and stabilize such complex chaotic systems.

25 ENERGY STORAGE↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Medium-Duty Delivery Truck Integrated Bidirectional Wireless Power Transfer System With Grid and Stationary Energy Storage System Connectivity

Electric vehicles (EVs) can provide power to the grid or buildings similar to distributed energy resources (DER) for energy balancing applications or optimizing the operation of the microgrids in harmony with the other DER assets. This article presents the operating modes of a bidirectional wireless power transfer (WPT) system designed for a medium-duty package delivery vehicle. The WPT system designed for this study can transfer 20 kW of power across 11 in of air gap using custom-designed double-D (DD) couplers with LCC–LCC tuning networks. The proposed system utilizes a 480-V three-phase grid connection, a plug-in hybrid delivery truck with bidirectional WPT, and a stationary energy storage system (SESS) that can be connected to the primary-side dc link. Due to the differences in primary and secondary dc bus voltages, and considering the voltage of the SESS, asymmetric voltage gains were used in the system. Sensitivity analyses of this system with respect to these voltage levels are presented. Five different operating modes of the grid, SESS, and the EV battery are investigated with experimental results. Control algorithms are described for grid-to-vehicle (G2V) and vehicle-to-grid (V2G) operating modes. A bidirectional WPT system is operated with a power factor of 0.99 on the grid side in every operating mode. The EV battery was charged with 20.3 kW with an overall efficiency of 93.02% in the G2V operating mode. Finally, in the V2G operating mode, the WPT system provided 12.82 kW of power back to the grid with an overall efficiency of 89.08%.

25 ENERGY STORAGE↗

Welcome to the Special Issue on Grid-Edge Computing With Behind-the-Meter Resources [Guest Editorial]

The integration of distributed energy resources (DERs), such as solar photovoltaic systems, as well as other synergistic assets, including electric vehicles, energy storage, and smart appliances, in electric power systems has been dramatically increasing in the past few years. These assets have the capability to provide much-needed flexibility to electric power systems for improved grid reliability, resilience, and economic efficiency; however, most of these resources are located behind the meter (BTM) on customer premises, and their flexibility is not fully used in current grid operations. Grid-edge computing plays an important role in unlocking the great benefits and potential that BTM resources could provide to electric power systems by enhancing visibility and controllability at the grid edge.

behind-the-meter resources↗

System and Component Development of Particle-Based Pumped Thermal Energy Storage

Reliable power supply from variable renewable resources requires energy storage at various scales to overcome resource intermittency. Long-duration energy storage (LDES, 10-100 hours) can improve dispatchability and grid reliability with increasing levels of renewable power supply. Thermal energy storage (TES) has siting flexibility and the ability to store a large capacity of energy, and thus has the potential to meet the LDES need and provide charging and discharging durations beyond the economic capacity of conventional batteries. TES technology has evolved from concentrating solar thermal power (CSP) generation and is recognized as an economic large-scale energy storage method. A standalone electric-thermal energy storage system supporting renewable integration of wind and solar power without CSP solar field can firm renewable generation and boost overall grid resilience and security.

concentrating solar thermal power↗

200 h of discharge cycling with an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) offer an approach to energy storage and electricity generation by harnessing low-grade heat (T < 150 °C). A TRAB discharge resembles that of a flow battery, where electrochemical reactions produce electrical power from energy stored within aqueous electrolytes. While there are many types of TRABs, the all-aqueous copper TRAB (Cu aq -TRAB) has produced the largest power and energy storage densities. Despite many improvements to TRAB performance, most tests have only lasted a few hours, which are not representative of operation times expected of these devices. Herein, we operated a Cu aq -TRAB for 200 h of constant current discharging to assess battery performance and component stability. After 200 h of testing, the average power density increased slightly to 7.2 mW cm -2 , which was within 0.01 % of starting conditions. Likewise, the average energy density for the final cycle was only 0.03 % lower than the initial cycle. The overall insensitivity of the power cell to cycling represents a major milestone in the advancement of TRAB systems. In conclusion, energy dispersive X-ray spectroscopy provides evidence to suggest that these small changes in power and energy density are likely to the membrane acclimating to TRAB electrolytes.

25 ENERGY STORAGE↗

Grid-Interactive Efficient Buildings Technical Report Series: Overview of Research Challenges and Gaps

These reports evaluate state-of-the-art and emerging building technologies that have significant potential to provide grid services. The reports also identify major research challenges and gaps facing the technologies as well as opportunities for technology-specific R&D. The GEB Technical Report Series will help inform and guide BTO's portfolio and serve as a foundational resource for the larger building research community. On-site behind-the-meter generation, battery storage, and electric vehicles are also an important part of the distributed energy resource (DER) optimization strategy for buildings. In general, the component technology reports do not focus on distributed generation or battery storage, but the Whole-Building Controls, Sensors, Modeling, and Analytics report discusses how a building can optimize across all DERs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Spatial Variation in Flexibility on System Operations in Electric Power Systems

With the expansion of renewable energy resources in the electric power systems, having flexibility in the setup will allow to maintain the system's reliability and prevailing operations. Such flexibility can be extracted from utility operated and/or consumer owned devices, such as, storage devices, electric vehicles, etc. For the demand side, generally consumer preferences, incentives, etc. enact on the availability of the flexibility; besides, both the spatial and temporal dimension dictates the degree of the flexibility. Consequently, the optimal dispatch of the grid resources might appear intractable as the considerable amount of flexibility are obliquely stemming from the ungovernable consumer devices. Thus characterizing the consequences of diverged feasible flexibility in the system is crucial for operations. In this paper, a procedure is developed to quantify the degree of flexibility of power systems in terms of resource dispatch reconfiguration. Specifically, we develop optimization problems to attain equivalent resource configurations for the power systems to evaluate the spatial volatility of the network and asses the flexibility of the system. The developed process is then validated using numerical simulations for IEEE-30 bus test system.

Sadnan, Rabayet↗