Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron energy filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Designs and Materials for Better Coronagraph Occulting Masks

New designs, and materials appropriate for such designs, are under investigation in an effort to develop coronagraph occulting masks having broad-band spectral characteristics superior to those currently employed. These designs and materials are applicable to all coronagraphs, both ground-based and spaceborne. This effort also offers potential benefits for the development of other optical masks and filters that are required (1) for precisely tailored spatial transmission profiles, (2) to be characterized by optical-density neutrality and phase neutrality (that is, to be characterized by constant optical density and constant phase over broad wavelength ranges), and/or (3) not to exhibit optical- density-dependent phase shifts. The need for this effort arises for the following reasons: Coronagraph occulting masks are required to impose, on beams of light transmitted through them, extremely precise control of amplitude and phase according to carefully designed transmission profiles. In the original application that gave rise to this effort, the concern has been to develop broad-band occulting masks for NASA s Terrestrial Planet Finder coronagraph. Until now, experimental samples of these masks have been made from high-energy-beam-sensitive (HEBS) glass, which becomes locally dark where irradiated with a high-energy electron beam, the amount of darkening depending on the electron-beam energy and dose. Precise mask profiles have been written on HEBS glass blanks by use of electron beams, and the masks have performed satisfactorily in monochromatic light. However, the optical-density and phase profiles of the HEBS masks vary significantly with wavelength; consequently, the HEBS masks perform unsatisfactorily in broad-band light. The key properties of materials to be used in coronagraph occulting masks are their extinction coefficients, their indices of refraction, and the variations of these parameters with wavelength. The effort thus far has included theoretical predictions of performances of masks that would be made from alternative materials chosen because the wavelength dependences of their extinction coefficients and their indices of refraction are such that that the optical-density and phase profiles of masks made from these materials can be expected to vary much less with wavelength than do those of masks made from HEBS glass. The alternative materials considered thus far include some elemental metals such as Pt and Ni, metal alloys such as Inconel, metal nitrides such as TiN, and dielectrics such as SiO2. A mask as now envisioned would include thin metal and dielectric films having stepped or smoothly varying thicknesses (see figure). The thicknesses would be chosen, taking account of the indices of refraction and extinction coefficients, to obtain an acceptably close approximation of the desired spatial transmittance profile with a flat phase profile

Balasubramanian, Kunjithapatham↗

Electronic Power System Application of Diamond-Like Carbon Films

A prototype manufacturing technology for producing high volume efficiency and high energy density diamond-like carbon (DLC) capacitors has been developed. Unique dual ion-beam deposition and web-handling systems have been designed and constructed to deposit high quality DLC films simultaneously on both sides of capacitor grade aluminum foil and aluminum-coated polymer films. An optimized process, using inductively coupled RF ion sources, has been used to synthesize electrically robust DLC films. DLC films are amorphous and highly flexible, making them suitable for the production of wound capacitors. DLC capacitors are reliable and stable over a wide range of AC frequencies from 20 Hz to 1 MHz, and over a temperature range from .500 C to 3000 C. The compact DLC capacitors offer at least a 50% decrease in weight and volume and a greater than 50% increase in temperature handling capability over equal value capacitors built with existing technologies. The DLC capacitors will be suitable for high temperature, high voltage, pulsed power and filter applications.

Wu, Richard L. C.↗

NASA Tech Briefs, May 2004

Topics include: Embedded Heaters for Joining or Separating Plastic Parts; Curing Composite Materials Using Lower-Energy Electron Beams; Aluminum-Alloy-Matrix/Alumina-Reinforcement Composites; Fibrous-Ceramic/Aerogel Composite Insulating Tiles; Urethane/Silicone Adhesives for Bonding Flexing Metal Parts; Scalable Architecture for Multihop Wireless ad Hoc Networks; Improved Thermoplastic/Iron-Particle Transformer Cores; Cooperative Lander-Surface/Aerial Microflyer Missions for Mars Exploration Dual-Frequency Airborne Scanning Rain Radar Antenna System Eight-Channel Continuous Timer Reduction of Phase Ambiguity in an Offset-QPSK Receiver Ambient-Light-Canceling Camera Using Subtraction of Frames Lightweight, Flexible, Thin, Integrated Solar-Power Packs Windows(Registered Trademark)-Based Software Models Cyclic Oxidation Behavior Software for Analyzing Sequences of Flow-Related Images Improved Ball-and-Socket Docking Mechanism Two-Stage Solenoid Ordered Nanostructures Made Using Chaperonin Polypeptides Low-Temperature Plasma Functionalization of Carbon Nanotubes Improved Cryostat for Cooling a Wide Panel Current Pulses Momentarily Enhance Thermoelectric Cooling Hand-Held Color Meters Based on Interference Filters Calculating Mass Diffusion in High-Pressure Binary Fluids Fresnel Lenses for Wide-Aperture Optical Receivers Increasing Accuracy in Computed Inviscid Boundary Conditions Higher-Order Finite Elements for Computing Thermal Radiation Radar for Monitoring Hurricanes from Geostationary Orbit Time-Transfer System for Two Orbiting Spacecraft

Source record↗

Process Recipes for Additively Printed Copper Ink Flexible Circuits using Direct Write Methods

In this paper, the process-recipes and process-performance relationships for additive-printing of copper circuits using direct-write methods have been studied. The process has been implemented on the direct write platform. Interest in the use of additive printing methods for the manufacture of micro-circuits has grown immensely in recent times. Direct write methods have been shown to have the ability to create circuits in a limited manner. However, the process recipes and the effect of process parameters on the manufactured properties are not well understood. Copper ink is a good and cost-effective alternative to silver ink but its use has lagged owing to an increased propensity for oxidation. In this paper, photonic curing has been used to sinter copper ink to make the traces conductive. The method flashes high energy light that sinter metal particles instantaneously and the temperature of the substrate remains low. The effect of the different photonic sintering profiles on the mechanical and electrical properties of the printed traces has been studied in this paper.The print process parameters also play an important role in the line width and height that has been studied to print with the desired line profile for the end application. An LC filter circuit is been printed with SMD components been attached using an electrically conductive adhesive (ECA). The manufactured flexible LC filter is been tested for its frequency sweep to compare with the commercially available LC filer with the help of the Bode plot.

Process control↗

Machine-learning-assisted analysis of transition metal dichalcogenide thin-film growth

In situ reflective high-energy electron diffraction (RHEED) is widely used to monitor the surface crystalline state during thin-film growth by molecular beam epitaxy (MBE) and pulsed laser deposition. With the recent development of machine learning (ML), ML-assisted analysis of RHEED videos aids in interpreting the complete RHEED data of oxide thin films. The quantitative analysis of RHEED data allows us to characterize and categorize the growth modes step by step, and extract hidden knowledge of the epitaxial film growth process. In this study, we employed the ML-assisted RHEED analysis method to investigate the growth of 2D thin films of transition metal dichalcogenides (ReSe2) on graphene substrates by MBE. Principal component analysis (PCA) and K-means clustering were used to separate statistically important patterns and visualize the trend of pattern evolution without any notable loss of information. Using the modified PCA, we could monitor the diffraction intensity of solely the ReSe2 layers by filtering out the substrate contribution. These findings demonstrate that ML analysis can be successfully employed to examine and understand the film-growth dynamics of 2D materials. Further, the ML-based method can pave the way for the development of advanced real-time monitoring and autonomous material synthesis techniques.

36 MATERIALS SCIENCE↗

Resonant tunneling IR detectors

Researchers propose a novel semiconductor heterojunction photodetector which would have a very low dark current and would be voltage tunable. A schematic diagram of the device and its band structure are shown. The two crucial components of the device are a cathode (InGaAs) whose condition band edge is below the conduction band edge of the quantum wells and a resonant tunneling filter (GaAs-AlGaAs). In a standard resonant tunneling device the electrodes are made of the same material as the quantum wells, and this device becomes highly conducting when the quantum levels in the wells are aligned with the Fermi level in the negatively biased electrode. In contrast, the researchers device is essentially non-conducting under the same bias conditions. This is because the Fermi Level of the cathode (InGaAs) is still well below the quantum levels so that no resonant transport occurs and the barriers (AlGaAs) effectively block current flow through the device. However, if light with the same photon energy as the conduction-band discontinuity between the cathode and the quantum wells, E sub c3-E sub c1, is shone on the sample, free carriers will be excited to an energy corresponding to the lowest quantum level in the well closest to the cathode (hv plue E sub c1 = E sub o). These electrons will resonantly tunnel through the quantum wells and be collected as a photocurrent in the anode (GaAs). To improve the quantum efficiency, the cathode (InGaAs) should be very heavily doped and capped with a highly reflective metal ohmic contact. The thickness of the device should be tailored to optimize thin film interference effects and afford the maximum absorption of light. Because the device relies on resonant tunneling, its response should be very fast, and the small voltages needed to change the responsivity should allow for very high frequency modulation of the photocurrent. In addition, the device is tuned to a specific photon energy so that it can be designed to detect a fairly narrow range of wavelengths. This selectivity is important for reducing the photocurrent due to spurious light sources.

Woodall, Jerry M.↗

Software Development for Data Visualization and Analysis of PN-Diodes & MOSFET Devices

The U.S. Department of Energy has a broad mission to ensure the nation’s security by addressing ongoing environmental challenges, developing novel energy production technologies, and mitigating nuclear security concerns. These efforts benefit from developing more effective semiconductor materials and devices. The research discussed in this report aims to further the development of these new electronics by improving implementations of vertical device structures, which offer theoretically better performance compared to lateral structures. Specifically, it reviews the background and development of a new and easy-to-use program for data processing and analysis from experiments run on vertical gallium nitride power devices. Current vertical structures fall short in critical performance metrics, such as On-Resistance and Breakdown Voltage, due to poor management of the device’s electric field. Junction termination extensions, or JTEs, are a field management technique that increases a device’s resilience to expected failure modes by controlling its surface electric fields. Each JTE design requires significant experimental validation, consisting of hundreds of tested devices, each outputting an enormous set of data points. The new software includes multiple methods of filtering large sets of device testing data to identify and remove flawed devices, automate device analyses, and provide statistical breakdowns for four metrics used to define the effectiveness of the JTE and the current carrying capacity of the device. These results can then be related back to fabrication techniques and device design, and in the future, be combined with processing simulations to further improve our understanding of the JTE mechanisms.

97 MATHEMATICS AND COMPUTING↗

Non-fullerene acceptor organic photovoltaics with intrinsic operational lifetimes over 30 years

Abstract Organic photovoltaic cells (OPVs) have the potential of becoming a productive renewable energy technology if the requirements of low cost, high efficiency and prolonged lifetime are simultaneously fulfilled. So far, the remaining unfulfilled promise of this technology is its inadequate operational lifetime. Here, we demonstrate that the instability of NFA solar cells arises primarily from chemical changes at organic/inorganic interfaces bounding the bulk heterojunction active region. Encapsulated devices stabilized by additional protective buffer layers as well as the integration of a simple solution processed ultraviolet filtering layer, maintain 94% of their initial efficiency under simulated, 1 sun intensity, AM1.5 G irradiation for 1900 hours at 55 °C. Accelerated aging is also induced by exposure of light illumination intensities up to 27 suns, and operation temperatures as high as 65 °C. An extrapolated intrinsic lifetime of > 5.6 × 10 4 h is obtained, which is equivalent to 30 years outdoor exposure.

14 SOLAR ENERGY↗

Quantitative approaches for multiscale structural analysis with atomic resolution electron microscopy

Atomic-resolution imaging with scanning transmission electron microscopy is a powerful tool for characterizing the nanoscale structure of materials, in particular features such as defects, local strains, and symmetry-breaking distortions. In addition to advanced instrumentation, the effectiveness of the technique depends on computational image analysis to extract meaningful features from complex datasets recorded in experiments, which can be complicated by the presence of noise and artifacts, small or overlapping features, and the need to scale analysis over large representative areas. Here, we present image analysis approaches which synergize real and reciprocal space information to efficiently and reliably obtain meaningful structural information with picometer scale precision across hundreds of nanometers of material from atomic-resolution electron microscope images. Damping superstructure peaks in reciprocal space allows symmetry-breaking structural distortions to be disentangled from other sources of inhomogeneity and measured with high precision. Real-space fitting of the wavelike signals resulting from Fourier filtering enables absolute quantification of lattice parameter variations and strain, as well as the uncertainty associated with these measurements. Implementations of these algorithms are made available as an open source python package.

36 MATERIALS SCIENCE↗

Correcting x ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Correcting X-ray spectra obtained from the AXAF VETA-I mirror calibration for pileup, continuum, background and deadtime

The VETA-I mirror was calibrated with the use of a collimated soft X-ray source produced by electron bombardment of various anode materials. The FWHM, effective area and encircled energy were measured with the use of proportional counters that were scanned with a set of circular apertures. The pulsers from the proportional counters were sent through a multichannel analyzer that produced a pulse height spectrum. In order to characterize the properties of the mirror at different discrete photon energies one desires to extract from the pulse height distribution only those photons that originated from the characteristic line emission of the X-ray target source. We have developed a code that fits a modeled spectrum to the observed X-ray data, extracts the counts that originated from the line emission, and estimates the error in these counts. The function that is fitted to the X-ray spectra includes a Prescott function for the resolution of the detector a second Prescott function for a pileup peak and a X-ray continuum function. The continuum component is determined by calculating the absorption of the target Bremsstrahlung through various filters, correcting for the reflectivity of the mirror and convolving with the detector response.

Chartas, G.↗

Laboratory Astrophysics Using a Spare XRS Microcalorimeter

The XRS instrument on Astro-E is a fully self-contained microcalorimeter x-ray instrument capable of acquiring optimally filtering, and characterizing events for 32 independent pixels. With the launch of the Astro-E spacecraft, a full flight spare detector system has been integrated into a laboratory cryostat for use on the electron beam ion trap (EBIT) at Lawrence Livermore National Laboratory. The detector system contains a microcalorimeter array with 32 instrumented pixels heat sunk to 60 mK using an adiabatic demagnetization refrio,erator. The instrument has a composite resolution of 8eV at 1 keV and 12eV at 6 keV with a minimum of 95% quantum efficiency. This will allow high spectral resolution, broadband observations of collisionally excited plasmas which are produced in the EBIT experiment. Unique to our instrument are exceptionally well characterized 1000 Angstrom thick aluminum on polyimide infrared blocking filters. The detailed transmission function including the edc,e fine structure of these filters has been measured in our laboratory using an erect field grating spectrometer. This will allow the instrument to perform the first broadband absolute flux measurements with the EBIT instrument. The instrument performance as well as the results of preliminary measurements will be discussed. Work performed under the auspices of the U.S. D.o.E. by Lawrence Livermore National Laboratory under contract W-7405-ENG-48 and was supported by the NASA High Energy Astrophysics Supporting Research and Technology Program.

Audley, M. Damian↗

Real-time data reduction at 100 Tbps: Challenge and opportunity for AI-based data reduction for next-generation large-scale nuclear physics collider experiment

The modern large-scale nuclear physics (NP) experiments in high-energy particle colliders utilize streaming-readout electronics to digitize detector response at O(100) Tbps bandwidth. Prominent examples at Brookhaven National Lab (BNL) include the sPHENIX experiment at Relativistic Heavy Ion Collider (RHIC), which is under construction, and the experiments proposed for the Electron-Ion Collider (EIC), planned for the 2030s . One of the main challenges for these streaming readout systems is to manage the data rate with sufficient data reduction in real time so the end-data fit persistent storage for offline analysis, which is typically at O(1000) times smaller and O(100) Gbps. Such data reduction traditionally is achieved via real-time high level triggers, which select and save a small subset of collisions of interest. Although triggering is applicable to high energy collider experiments such as those at the Large Hardron Collider at CERN, it is insufficient for these nuclear physics experiments which study diverse collision topologies. And traditional triggering approach is inefficient to preserve the max information harvested from the operation of colliders that costs O(100)M per year to DOE. Meanwhile, in recent years, ML-based high-throughput data reduction has emerged as a promising approach to efficiently preserve max information for a given space of persistent storage, e.g. via AI data compression, feature extraction, and noise filtering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetometer Based on Optoelectronic Microwave Oscillator

proposed instrument, intended mainly for use as a magnetometer, would include an optoelectronic oscillator (OEO) stabilized by an atomic cell that could play the role of a magnetically tunable microwave filter. The microwave frequency would vary with the magnetic field in the cell, thereby providing an indication of the magnetic field. The proposed magnetometer would offer a combination of high accuracy and high sensitivity, characterized by flux densities of less than a picotesla. In comparison with prior magnetometers, the proposed magnetometer could, in principle, be constructed as a compact, lightweight instrument: It could fit into a package of about 10 by 10 by 10 cm and would have a mass <0.5 kg. As described in several prior NASA Tech Briefs articles, an OEO is a hybrid of photonic and electronic components that generates highly spectrally pure microwave radiation, and optical radiation modulated by the microwave radiation, through direct conversion between laser light and microwave radiation in an optoelectronic feedback loop. As used here, "atomic cell" signifies a cell containing a vapor, the constituent atoms of which can be made to undergo transitions between quantum states, denoted hyperfine levels, when excited by light in a suitable wavelength range. The laser light must be in this range. The energy difference between the hyperfine levels defines the microwave frequency. In the proposed instrument (see figure), light from a laser would be introduced into an electro-optical modulator (EOM). Amplitude-modulated light from the exit port of the EOM would pass through a fiber-optic splitter having two output branches. The light in one branch would be sent through an atomic cell to a photodiode. The light in the other branch would constitute the microwave-modulated optical output. Part of the light leaving the atomic cell could also be used to stabilize the laser at a frequency in the vicinity of the desired hyperfine or other quantum transition. The microwave signal from the output of the photodiode would be amplified (if necessary, as explained below) and fed back into the EOM. This system would oscillate if the amplification in the closed loop exceeded the linear absorption of the loop. The microwave amplifier may be unnecessary to sustain stable oscillations, depending on the power of the laser radiation at the photodetector and on particular features of the modulator and optical delay line.

Maleki, Lute↗

Demonstration of a laser-driven, narrow spectral bandwidth x-ray source for collective x-ray scattering experiments

X-ray Thomson scattering (XRTS) is a powerful diagnostic technique that involves an x-ray source interacting with a dense plasma sample, resulting in a spectrum of elastically and inelastically scattered x-rays. Depending on the plasma conditions, one can measure a range of parameters from the resulting spectrum, including plasma temperature, electron density, and ionization state. To achieve sensitivity to collective electron oscillations, XRTS measurements require limited momentum transfer where the spectral separation of elastic and inelastic scattering is small. Such measurements require an x-ray probe source with a narrow bandwidth in order to reduce the spectral overlap between scattering contributions, allowing for the different features to be more precisely deconvolved. In this investigation, we discuss the theory behind how the bandwidth for a common XRTS probe, Zn He-α emission at 9 keV, can be reduced using a Cu K-edge filter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Photochemical Decomposition of Y‐Series Non‐Fullerene Acceptors Is Responsible for Degradation of High‐Efficiency Organic Solar Cells

Abstract Organic photovoltaic cells that employ Y‐series non‐fullerene acceptors (NFAs) have recently achieved impressive power‐conversion efficiencies (>18%). To fulfill their commercial promise, it is important to quantify their operational lifetimes and understand their degradation mechanisms. In this work, the spectral‐dependent photostability of films and solar cells comprising several Y‐series acceptors and the donor polymer PM6 is investigated systematically. By applying longpass filters during aging, it is shown that UV/near‐UV photons are responsible for the photochemical decomposition of Y‐series acceptors; this degradation is the primary driver of early solar cell performance losses. Using mass spectrometry, the vinylene linkage between the core and electron‐accepting moieties of Y‐series acceptors is identified as the weak point susceptible to cleavage under UV‐illumination. Employing a series of device characterization, along with numerical simulations, the efficiency losses in organic photovoltaic cells are attributed to the formation of traps, which reduces charge extraction efficiency and facilitates non‐radiative recombination as the Y‐series acceptors degrade. This study provides new insights for molecular degradation of organic photovoltaic absorber materials and highlights the importance of future molecular design and strategies for improved solar cell stability.

14 SOLAR ENERGY↗

Simulation Study of Landau Damping Near the Persisting to Arrested Transition

A one-dimensional electrostatic filtered Vlasov-Poisson simulation study is discussed. The transition from persisting to arrested Landau damping that is produced by increasing the strength of a sinusoidal perturbation on a background Vlasov-Poisson equilibrium is explored. Emphasis is placed on observed features of the electron phase-space distribution when the perturbation strength is near the transition value. A single ubiquitous waveform is found perturbing the space-averaged phase-space distribution at almost any time in all of the simulations; the sole exception is the saturation stage that can occur at the end of the arrested damping scenario. This waveform contains relatively strong, very narrow structures in velocity bracketing (plus or minus velocity (sub res)) - the velocities at which electrons must move to traverse the dominant field mode wavelength in one of its oscillation periods - and propagating with (plus or minus velocity (sub res)) respectively. Local streams of electrons are found in these structures crossing the resonant velocities from low speed to high speed during Landau damping and from high speed to low speed during Landau growth. At the arrest time, when the field strength is briefly constant, these streams vanish. It is conjectured that the expected transfer of energy between electrons and field during Landau growth or damping has been visualized for the first time. No evidence is found in the phase-space distribution to support recent well-established discoveries of a second-order phase transition in the electric field evolution. While trapping is known to play a role for larger perturbation strengths, it is shown that trapping plays no role at any time in any of the simulations near the transition perturbation strength.

plasma simulation↗