Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Moderate pressure plasma source of nonthermal electrons

Plasma sources of electrons offer control of gas and surface chemistry without the need for complex vacuum systems. The plasma electron source presented here is based on a cold cathode glow discharge (GD) operating in a dc steady state mode in a moderate pressure range of 2–10 torr. Ion-induced secondary electron emission is the source of electrons accelerated to high energies in the cathode sheath potential. The source geometry is a key to the availability and the extraction of the nonthermal portion of the electron population. The source consists of a flat and a cylindrical electrode, 1 mm apart. Our estimates show that the length of the cathode sheath in the plasma source is commensurate (~0.5–1 mm) with the inter-electrode distance so the GD operates in an obstructed regime without a positive column. Estimations of the electron energy relaxation confirm the non-local nature of this GD, hence the nonthermal portion of the electron population is available for extraction outside of the source. The use of a cylindrical anode presents a simple and promising method of extracting the high energy portion of the electron population. Langmuir probe measurements and optical emission spectroscopy confirm the presence of electrons with energies ~15 eV outside of the source. These electrons become available for surface modification and radical production outside of the source. In conclusion, the extraction of the electrons of specific energies by varying the anode geometry opens exciting opportunities for future exploration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic neutron sources for compensated porosity well logging

The viability of replacing Americium–Beryllium (Am–Be) radiological neutron sources in compensated porosity nuclear well logging tools with D–T or D–D accelerator-driven neutron sources is explored. The analysis consisted of developing a model for a typical well-logging borehole configuration and computing the helium-3 detector response to varying formation porosities using three different neutron sources (Am–Be, D–D, and D–T). The results indicate that, when normalized to the same source intensity, the use of a D–D neutron source has greater sensitivity for measuring the formation porosity than either an Am–Be or D–T source. The results of the study provide operational requirements that enable compensated porosity well logging with a compact, low power D–D neutron generator, which the current state-of-the-art indicates is technically achievable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron energy distributions and electron impact source functions in Ar/N{sub 2} inductively coupled plasmas using pulsed power

In plasma materials processing, such as plasma etching, control of the time-averaged electron energy distributions (EEDs) in the plasma allows for control of the time-averaged electron impact source functions of reactive species in the plasma and their fluxes to surfaces. One potential method for refining the control of EEDs is through the use of pulsed power. Inductively coupled plasmas (ICPs) are attractive for using pulsed power in this manner because the EEDs are dominantly controlled by the ICP power as opposed to the bias power applied to the substrate. In this paper, we discuss results from a computational investigation of EEDs and electron impact source functions in low pressure (5–50 mTorr) ICPs sustained in Ar/N{sub 2} for various duty cycles. We find there is an ability to control EEDs, and thus source functions, by pulsing the ICP power, with the greatest variability of the EEDs located within the skin depth of the electromagnetic field. The transit time of hot electrons produced in the skin depth at the onset of pulse power produces a delay in the response of the EEDs as a function of distance from the coils. The choice of ICP pressure has a large impact on the dynamics of the EEDs, whereas duty cycle has a small influence on time-averaged EEDs and source functions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

61 RADIATION PROTECTION AND DOSIMETRY↗

Thermionic Sources For Electron Cooling At IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project at the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling of 2.5 MeV protons in the presence of intense space-charge. Furthermore, we are constructing an electron source test stand at the University of Chicago which will validate the electrical, thermal, and vacuum characteristics of thermionic sources. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources for electron cooling and the test stand.

43 PARTICLE ACCELERATORS↗

Compact x-ray source and panel

A compact, self-contained x-ray source, and a compact x-ray source panel having a plurality of such x-ray sources arranged in a preferably broad-area pixelized array. Each x-ray source includes an electron source for producing an electron beam, an x-ray conversion target, and a multilayer insulator separating the electron source and the x-ray conversion target from each other. The multi-layer insulator preferably has a cylindrical configuration with a plurality of alternating insulator and conductor layers surrounding an acceleration channel leading from the electron source to the x-ray conversion target. A power source is connected to each x-ray source of the array to produce an accelerating gradient between the electron source and x-ray conversion target in any one or more of the x-ray sources independent of other x-ray sources in the array, so as to accelerate an electron beam towards the x-ray conversion target. The multilayer insulator enables relatively short separation distances between the electron source and the x-ray conversion target so that a thin panel is possible for compactness. This is due to the ability of the plurality of alternating insulator and conductor layers of the multilayer insulators to resist surface flashover when sufficiently high acceleration energies necessary for x-ray generation are supplied by the power source to the x-ray sources.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-71: A Practical Method for Evaluation of Electron Virtual Source Position

Purpose: Since electrons are easily scattered, the virtual source position for electrons is expected to locate below the x-ray target of Medical Linacs. However, the effective SSD method yields the electron virtual position above the x-ray target for some applicators for some energy in Siemens Linacs. In this study, we propose to use IC Profiler (Sun Nuclear) for evaluating the electron virtual source position for the standard electron applicators for various electron energies. Methods: The profile measurements for various nominal source-to-detector distances (SDDs) of 100–115 cm were carried out for electron beam energies of 6–18 MeV. Two methods were used: one was to use a 0.125 cc ion chamber (PTW, Type 31010) with buildup mounted in a PTW water tank without water filled; and the other was to use IC Profiler with a buildup to achieve charge particle equilibrium. The full width at half-maximum (FWHM) method was used to determine the field sizes for the measured profiles. Backprojecting (by a straight line) the distance between the 50% points on the beam profiles for the various SDDs, yielded the virtual source position for each applicator. Results: The profiles were obtained and the field sizes were determined by FWHM. The virtual source positions were determined through backprojection of profiles for applicators (5, 10, 15, 20, 25). For instance, they were 96.415 cm (IC Profiler) vs 95.844 cm (scanning ion chamber) for 9 MeV electrons with 10×10 cm applicator and 97.160 cm vs 97.161 cm for 12 MeV electrons with 10×10 cm applicator. The differences in the virtual source positions between IC profiler and scanning ion chamber were within 1.5%. Conclusion: IC Profiler provides a practical method for determining the electron virtual source position and its results are consistent with those obtained by profiles of scanning ion chamber with buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A liquid jet setup for x-ray scattering experiments on complex liquids at free-electron laser sources

In this paper we describe a setup for x-ray scattering experiments on complex fluids using a liquid jet. The setup supports Small and Wide Angle X-ray Scattering (SAXS/WAXS) geometries. The jet is formed by a gas-dynamic virtual nozzle (GDVN) allowing for diameters ranging between 1 μm and 20 μm at a jet length of several hundred μm. To control jet properties such as jet length, diameter, or flow rate, the instrument is equipped with several diagnostic tools. Three microscopes are installed to quantify jet dimensions and stability in situ. The setup has been used at several beamlines performing both SAXS and WAXS experiments. As a typical example we show an experiment on a colloidal dispersion in a liquid jet at the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source free-electron laser.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Thermionic Sources for Electron Cooling at IOTA

We are designing and fabricating two new thermionic sources of magnetized electrons for use in the electron lens project in the Integrable Optics Test Accelerator (IOTA) at Fermilab. These electron sources will be used for cooling 2.5 MeV protons. One source will be used to compensate for emittance growth due to Intra Beam Scattering in experiments with weak space-charge, while the other source will be used to research the interplay between electron cooling and intense space charge. In this paper we present the progress made so far and the upcoming steps for the thermionic electron sources.

43 PARTICLE ACCELERATORS↗

Numerical simulations of early-stage dynamics of electron bunches emitted from plasmonic photocathodes

High-brightness electron sources are a key ingredient to the development of compact accelerator-based light sources. The electron sources are commonly based on (linear) photoemission process where a laser pulse with proper wavelength impinges on the surface of a metallic or semiconductor photocathode. Very recently, the use of plasmonic cathodes - cathodes with a nano-patterned surface - have demonstrated great enhancement in quantum efficiencies (Li et al., 2013 [1]). Alternatively, this type of photocathodes could support the formation of structured beams composed of transversely-separated beamlets. In this paper we discuss numerical simulations of the early-stage beam dynamics of the emission process from plasmonic cathodes carried out using the Warp (Friedman et al., 2014 [2]) framework. Furthermore, the model is used to investigate the properties of beams emitted from these photocathode and subsequently combined with particle-in-cell simulations to explore the imaging of cathode pattern after acceleration in a radiofrequency gun.

43 PARTICLE ACCELERATORS↗

Electron Accelerator Shielding Design of KIPT Neutron Source Facility

The Argonne National Laboratory of the United States and the Kharkov Institute of Physics and Technology of the Ukraine have been collaborating on the design, development and construction of a neutron source facility at Kharkov Institute of Physics and Technology utilizing an electron-accelerator-driven subcritical assembly. The electron beam power is 100 kW using 100-MeV electrons. The facility was designed to perform basic and applied nuclear research, produce medical isotopes, and train nuclear specialists. The biological shield of the accelerator building was designed to reduce the biological dose to less than 5.0e-03 mSv/h during operation. The main source of the biological dose for the accelerator building is the photons and neutrons generated from different interactions of leaked electrons from the electron gun and the accelerator sections with the surrounding components and materials. The Monte Carlo N-particle extended code (MCNPX) was used for the shielding calculations because of its capability to perform electron-, photon-, and neutron-coupled transport simulations. The photon dose was tallied using the MCNPX calculation, starting with the leaked electrons. However, it is difficult to accurately tally the neutron dose directly from the leaked electrons. The neutron yield per electron from the interactions with the surrounding components is very small, similar to 0.01 neutron for 100-MeV electron and even smaller for lower-energy electrons. This causes difficulties for the Monte Carlo analyses and consumes tremendous computation resources for tallying the neutron dose outside the shield boundary with an acceptable accuracy. To avoid these difficulties, the SOURCE and TALLYX user subroutines of MCNPX were utilized for this study. The generated neutrons were banked, together with all related parameters, for a subsequent MCNPX calculation to obtain the neutron dose. The weight windows variance reduction technique was also utilized for both neutron and photon dose calculations. Two shielding materials, heavy concrete and ordinary concrete, were considered for the shield design. The main goal is to maintain the total dose outside the shield boundary less than 5.0e-03 mSv/h during operation. The shield configuration and parameters of the accelerator building were determined and are presented in this paper. Copyright (C) 2016, Published by Elsevier Korea LLC on behalf of Korean Nuclear Society.

43 PARTICLE ACCELERATORS↗

Wall heating by subcritical energetic electrons generated by the runaway electron avalanche source *

Abstract Subcritical energetic electrons (SEEs) produced by the runaway electron (RE) avalanche source at energies below the runaway threshold are found to be the primary contributor to surface heating of plasma-facing components (PFCs) during final loss events. This finding is supported by theoretical analysis, computational modeling with the Kinetic Orbit Runaway electrons Code (KORC), and qualitative agreement with DIII-D experimental observations. The avalanche source generates significantly more secondary electrons below the runaway threshold, which thermalize rapidly when well-confined. However, during a final loss event, the RE beam impacts the first wall, and SEEs are deconfined before they can thermalize. Additionally, because the energy deposition length decreases faster than energy, the deposited energy density, and thus the maximum PFC surface temperature change, is larger for SEEs than REs. KORC simulations employ an analytic first wall to model particle deconfinement onto a non-axisymmetric wall composed of individual tiles. PFC surface heating is calculated using a 1D model extended to include an energy-dependent deposition length scale. Simulations of DIII-D qualitatively agree with infrared (IR) imaging only when SEEs from the avalanche source are included. These results demonstrate that SEEs are the dominant contributor to PFC surface heating and indicate that the avalanche source plays a critical role in the PFC damage caused during final loss events. The prominence of SEEs also has important implications for interpreting IR imaging, one of the primary diagnostics for RE-wall interaction diagnosis, despite REs dominating the energy and current density. This result improves predictions of wall damage due to post-disruption REs to estimate material lifetime and design RE mitigation systems for ITER and future reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical simulation of ion charge breeding in electron beam ion source

The Electron Beam Ion Source particle-in-cell code (EBIS-PIC) tracks ions in an EBIS electron beam while updating electric potential self-consistently and atomic processes by the Monte Carlo method. Recent improvements to the code are reported in this paper. The ionization module has been improved by using experimental ionization energies and shell effects. The acceptance of injected ions and the emittance of extracted ion beam are calculated by extending EBIS-PIC to the beam line transport region. An EBIS-PIC simulation is performed for a Cs charge-breeding experiment at BNL. The charge state distribution agrees well with experiments, and additional simulation results of radial profiles and velocity space distributions of the trapped ions are presented.

43 PARTICLE ACCELERATORS↗

Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer’s compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model for the description of ion beam extraction from electron cyclotron resonance ion sources

The finite difference method trajectory code KOBRA3-INP has been developed now for 25 years to perform the simulation of ion beam extraction in three dimensions. Meanwhile, the code has been validated for different applications: high current ion beam extraction from plasma sources for ion implantation technology, neutral gas heating in fusion devices, or ion thrusters for space propulsion. One major issue of the development of this code was to improve the flexibility of the applied model for the simulation of different types of particle sources. Fixed emitter sources might be simulated with that code as well as laser ion sources, Penning ion sources, electron cyclotron resonance ion sources (ECRISs), or H{sup -} sources, which require the simulation of negative ions, negative electrons, and positive charges simultaneously. The model which has been developed for ECRIS has now been used to explore the conditions for the ion beam extraction from a still nonexisting ion source, a so called ARC-ECRIS [P. Suominen and F. Wenander, Rev. Sci. Instrum. 79, 02A305 (2008)]. It has to be shown whether the plasma generator has similar properties like regular ECRIS. However, the emittance of the extracted beam seems to be much better compared to an ECRIS equipped with a hexapole.

43 PARTICLE ACCELERATORS↗

CW Superconducting RF Photoinjector Development for Energy Recovery Linacs

ERLs have the powerful potential to provide very high current beams with exceptional and tailored parameters for many applications, from next-generation light sources to electron coolers. However, the demands placed on the electron source are severe. It must operate CW, generating a current of 100 mA or more with a normalized emittance of order 1 {micro}m rad. Beyond these requirements, issues such as dark current and long-term reliability are critical to the success of ERL facilities. As part of the BERLinPro project, Helmholtz Zentrum Berlin (HZB) is developing a CWSRF photoinjector in three stages, the first of which is currently being installed at HZB's HoBiCaT facility. It consists of an SRF-cavity with a Pb cathode and a superconducting solenoid. Subsequent development stages include the integration of a high-quantum-efficiency cathode and RF components for high-current operation. This paper discusses the first stage towards an ERL-suitable SRF photoinjector, the present status of the facility and first cavity tests.

43 PARTICLE ACCELERATORS↗

Quasi-monochromatic field-emission x-ray source

By favoring the L-peak emission over the bremsstrahlung part, direct quasi-monochromatic soft x-ray emission has been obtained with a field emission (FE) x-ray source. The electron impact x-ray setup uses an arrayed cathode of carbon nanopearl FE tips as a stable cold electron source within a vacuum of 10{sup -6}-10{sup -7} Torr. The high brightness of the FE e-beam coupled with the array structure of the cold cathode allows a smoother control of the x-ray emission intensity. The wavelength of the x-ray source can be modified by the choice of target materials. Using Mo as the target material, the x-ray emission shows a peak centered at 2.45 keV with a monochromaticity between 75% and 55% and a FWHM in the range of 450 eV.

43 PARTICLE ACCELERATORS↗