Search NASA⌕ Search

SEARCH · Search NASA

Results for “embedded sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Experimental Investigation of Low-Frequency Distributed Acoustic Strain-Rate Responses to Propagating Fractures

Summary Low-frequency distributed acoustic sensing (LF-DAS) responds to strain changes due to far-field fracture propagation. To better understand the LF-DAS response to fracture propagation, we performed laboratory-scale hydraulic fracture experiments with embedded optical strain sensors. The objectives of this research are to generate hydraulic fractures of known geometry, measure the strain response along the embedded fiber-optic cable comparable to LF-DAS measurements, and use the results to inform the interpretation of field-derived LF-DAS data. The experiments were conducted in unconfined transparent cubic blocks with a dimension of 8 in. on each side. The block was made of transparent epoxy to visualize the fracture propagation. Fiber-optic sensing cables were embedded in the block at different distances to the source of injection. We injected dyed water through an injection tubing to generate a transverse, radial fracture along an initial flaw. An optical interrogator recorded the response of offset fiber Bragg grating (FBG) strain sensors normal to the plane of the fracture. The strain data were visualized on a waterfall plot, akin to visualizations of field-derived LF-DAS data. Dimensional analysis was used to scale the laboratory results to field conditions. We compared the evolution of the strain response at the fiber-optic cable, injection pressure, and rate with known fracture geometry. The measured strains were compared with Sneddon’s (1946) linear elastic solution for a penny-shaped crack and found to follow this behavior. The generated radial fractures in transparent media can be modeled with Sneddon’s linear elastic radial fracture model and a Mode I critical stress intensity factor. The LF-DAS characteristic response of a narrowing region of extension surrounded by compression was exhibited as a fracture that approached and intersected the fiber-optic cable. The experimentally derived strain and strain-rate waterfall plots with known fracture geometry, injection rate, and pressure response provide insight in understanding LF-DAS responses in the field. Furthermore, we developed a method to estimate fracture geometry evolution from the fiber-optic strain data and validated the method against the experimental data.

Engineering↗

MELDI2 Do No Harm Test Series

Mars 2020 will fly the Mars Entry, Descent, and Landing Instrumentation II (MEDLI2) sensor suite consisting of a total of seventeen instrumented thermal sensor plugs, eight pressure transducers, two heat flux sensors, and one radiometer embedded in the thermal protection system (TPS). Of the MEDLI2 instrumentation, eleven instrumented thermal plugs and seven pressure transducers will be installed on the heatshield of the Mars 2020 vehicle while the rest will be installed on the backshell. The goal of the MEDLI2 instrumentation is to directly inform the large performance uncertainties that contribute to the design and validation of a Mars entry system. A better understanding of the entry environment and TPS performance could lead to reduced design margins enabling a greater payload mass-fraction and smaller landing ellipses. To prove that the MEDLI2 system will not degrade the performance of the Mars 2020 TPS, an Aerothermal Do No Harm (DNH) test series was designed and conducted. Like Mars 2020's predecessor, Mars Science Laboratory (MSL), the heatshield material will be Phenolic Impregnated Carbon Ablator (PICA); the Mars 2020 entry conditions are enveloped by the MSL design environments, therefore the development and qualification testing performed during MEDLI is sufficient to show that the similar MEDLI2 heatshield instrumentation will not degrade PICA performance. However, given that MEDLI did not include any backshell instrumentation, the MEDLI2 team was required to design and execute a DNH test series utilizing the backshell TPS material (SLA-561V) with the intended flight sensor suite. To meet the requirements handed down from Mars 2020, the MEDLI2 DNH test series emphasized the interaction between the MEDLI2 sensors and sensing locations with the surrounding backshell TPS and substrucutre. These interactions were characterized by performing environmental testing of four 12" by 12" test panels, which mimicked the construction of the backshell TPS and the integration of the MEDLI2 sensors as seen in Figure 1. The testing included thermal vacuum/ cycling, random vibration, shock, and arc jet testing. The test panels were fabricated by Lockheed Martin, establishing techniques that will be utilized during the Mars 2020 vehicle installation. Each test panel included one thermal sensor plug (two embedded thermocouples), one heat flux sensor, and multiple pressure port holes for evaluation. This presentation will discuss the planning and execution of the MEDLI2 DNH test series. Selected highlights and results of each environmental test will be presented, and lessons learned will be addressed that will feed forward into the planning for the MEDLI2 flight system certification testing.

Heatshield↗

Thermal Studies of CMS High-Granularity Calorimeter (HGCAL) Cassettes for the HL-LHC Upgrade

The CMS High Granularity Calorimeter (HGCAL) is a key endcap upgrade for the High-Luminosity LHC, designed to operate in an environment of extreme radiation and high particle rates. Each HGCAL cassette integrates silicon and scintillator modules, front-end ASICs, and a copper cooling plate that provides both mechanical integrity and thermal coupling using two-phase CO₂ cooling. Stable and uniform temperature control is essential to ensure reliable performance of the front-end electronics and to limit radiation-induced leakage currents in the silicon sensors. We present results from thermal characterization studies of pre-series HGCAL cassettes assembled and tested at Fermilab. Embedded RTD/PT1000 temperature sensors were used to measure gradients across copper cooling plates, module layers, and cassette edges under powering conditions representative of operation. The measured thermal behavior demonstrates effective heat transport through the cassette stack and highlights small but systematic variations correlated with geometry and assembly tolerances. These results validate the cooling performance of HGCAL cassettes.

Wang, Jinglu [Northwestern U.]↗

JSC Wireless Sensor Network Update

Sensor nodes composed of three basic components... radio module: COTS radio module implementing standardized WSN protocol; treated as WSN modem by main board main board: contains application processor (TI MSP430 microcontroller), memory, power supply; responsible for sensor data acquisition, pre-processing, and task scheduling; re-used in every application with growing library of embedded C code sensor card: contains application-specific sensors, data conditioning hardware, and any advanced hardware not built into main board (DSPs, faster A/D, etc.); requires (re-) development for each application.

Wagner, Robert↗

Wireless Sensor Node for Autonomous Monitoring and Alerts in Remote Environments

A method, apparatus, system, and computer program products provides personal alert and tracking capabilities using one or more nodes. Each node includes radio transceiver chips operating at different frequency ranges, a power amplifier, sensors, a display, and embedded software. The chips enable the node to operate as either a mobile sensor node or a relay base station node while providing a long distance relay link between nodes. The power amplifier enables a line-of-sight communication between the one or more nodes. The sensors provide a GPS signal, temperature, and accelerometer information (used to trigger an alert condition). The embedded software captures and processes the sensor information, provides a multi-hop packet routing protocol to relay the sensor information to and receive alert information from a command center, and to display the alert information on the display.

Monacos, Steve P.↗

Low-cost embedded optical sensing systems for distribution transformer monitoring

There is a mounting need for low-cost monitoring with online sensing technologies to maintain grid reliability and uptime. Here we introduce an innovative low-cost, embedded optical sensing technology initially focused on transformers that was developed and demonstrated at a major electric utility, Con Edison. A version of it that can be retrofitted onto existing transformers in the field was also developed. Two new 500 kVA distribution network transformers were built with embedded fiber-optic (FO) sensors and qualified per industry standards. Vibration, temperature, and corrosion were key parameters monitored. The first transformer with embedded FO sensors was installed at a Con Edison facility and monitored at our team’s office. The second one was installed in an urban street-side underground location with online data processing/feature extraction algorithms and monitored through a wireless router. Additionally, an older transformer was also retrofitted. Data analysis was done on these transformers showing promising correlations with their corresponding loading cycles. Furthermore, key events such as the transformer primary-side energizing, and other events were detected. In general, the technology was demonstrated over 6 months across the 3 transformers instrumented with promising results. Thus, it has the potential to enable predictive maintenance for transformers and other grid assets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Additively manufactured tamper evident container

A tamper evident container includes a container body having walls surrounding a cavity. The walls are composed of a non-electrically conductive material and at least one integrity sensor that is embedded in the non-electrically conductive material. A monitoring circuit is configured to monitor the tamper evident container using the at least one integrity sensor and determine a state-of-health of the tamper evident container.

Bernardin, John D.↗

Optical Strain Sensing for HEP and QIS

Optomechanical strain sensing provides attractive opportunities for novel particle detection schemes, as well as studying stress-induced (i.e. non-radiogenic) phonon bursts, which have been demonstrated to limit the coherence times of superconducting qubits [1,2] and are a suspected culprit in the low energy excesses observed by many dark matter direct detection experiments [3,4]. We are investigating SiN microring optical resonator strain sensors, developed at Purdue University [5], for applications in fundamental particle sensing and QIS. These sensors can be embedded in the substrate upon which superconducting qubits are patterned, providing a handle to distinguish decoherence events of radiogenic origin from those due to crystal stress. In a similar way, these sensors can be operated in conjunction with superconducting detectors (e.g., MKIDs, TES) to enable multi-channel readout of particle interactions in the device substrate or serve as anticoincidence detectors, which may be r equired to identify low-energy interactions from dark matter particles down to the fermionic thermal relic mass limit of a few keV. Such sensors can also be used to directly observe resonant scattering processes of gamma rays (and perhaps neutrinos) where no detectable quanta are produced in the target, via the microscopic strain induced by the momentum transfer to the (fixed-in-place) crystal lattice as a whole. These strain sensors have so far found application in photonics and communications, but have yet to be adopted for HEP uses, where they can provide unique capabilities in the search for dark matter, observing neutrino interactions, and improving the coherence times of superconducting qubits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Strain Sensing for Particle Detection

Optomechanical strain sensing provides attractive opportunities for novel particle detection schemes, as well as studying stress-induced (i.e. non-radiogenic) phonon bursts, which have been demonstrated to limit the coherence times of superconducting qubits and are a suspected culprit in the low energy excesses observed by many dark matter direct detection experiments. We are investigating SiN microring optical resonator strain sensors, developed at Purdue University, for applications in fundamental particle sensing and QIS. These sensors can be embedded in the substrate upon which superconducting qubits are patterned, providing a handle to distinguish decoherence events of radiogenic origin from those due to crystal stress. In a similar way, these sensors can be operated in conjunction with superconducting detectors (e.g., MKIDs, TES) to enable multi-channel readout of particle interactions in the device substrate or serve as anticoincidence detectors, which may be required to ident ify low-energy interactions from dark matter particles down to the fermionic thermal relic mass limit of a few keV. Such sensors can potentially be used to directly observe resonant scattering processes of gamma rays (and perhaps neutrinos) where no detectable quanta are produced in the target, via the microscopic stress induced by the momentum transfer to the (fixed-in-place) crystal lattice as a whole. These strain sensors have so far found application in photonics and communications, but have yet to be adopted for HEP uses, where they can provide unique capabilities in the search for dark matter as well as understanding and improving the coherence times of superconducting qubits.

43 PARTICLE ACCELERATORS↗

Distributed Sensing of Composite Over-wrapped Pressure Vessel Using Fiber-Bragg Gratings at Ambient and Cryogenic Temperatures

Fiber Bragg gratings are use to monitor the structural properties of composite pressure vessels. These gratings optically inscribed into the core of a single mode fiber are used as a tool to monitor the stress strain relation in laminate structure. The fiber Bragg sensors are both embedded within the composite laminates and bonded to the surface of the vessel with varying orientations with respect to the carbon fiber in the epoxy matrix. The response of these fiber-optic sensors is investigated by pressurizing the cylinder up to its burst pressure of around 2800 psi. This is done at both ambient and cryogenic temperatures using water and liquid nitrogen. The recorded response is compared with the response from conventional strain gauge also present on the vessel. Additionally, several vessels were tested that had been damaged to simulate different type of events, such as cut tow, delimitation and impact damage.

Grant, Joseph↗

Distributed sensing of Composite Over-wrapped Pressure Vessel using Fiber-Bragg Gratings at Ambient and Cryogenic Temperatures

Fiber Bragg gratings are use to monitor the structural properties of composite pressure vessels. These gratings optically inscribed into the core of a single mode fiber are used as a tool to monitor the stress strain relation in laminate structure. The fiber Bragg sensors are both embedded within the composite laminates and bonded to the surface of the vessel with varying orientations with respect to the carbon fiber in the epoxy matrix. The response of these fiber-optic sensors is investigated by pressurizing the cylinder up to its burst pressure of around 2800 psi. This is done at both ambient and cryogenic temperatures using water and liquid nitrogen. The recorded response is compared with the response from conventional strain gauge also present on the vessel. Additionally, several vessels were tested that had been damaged to simulate different type of events, such as cut tow, delimitation and impact damage.

Grant, Joseph↗

Distributed Pressure Sensing for Enabling Self-Aware Autonomous Aerial Vehicles

Autonomous aerial transportation will be a fixture of future robotic societies, simultaneously requiring more stringent safety requirements and fewer resources for characterization than current commercial air transportation. More robust, adaptable, self-state estimation will be necessary to create such autonomous systems. We present a modular, scalable, distributed pressure sensing skin for aerodynamic state estimation of a large, flexible aerostructure. This skin used a network of 22 nodes that performed in-situ computation and communication of data collected from 74 pressure sensors, which were embedded into the skin panels of an ultra-lightweight 14-foot wingspan made from commutable, lattice-based subcomponents, and tested at NASA Langley Research Center's 14X22 wind tunnel. The density of the pressure sensors allowed for the use of a novel distributed algorithm to generate estimates of the wing lift contribution that were more accurate than the direct integration of the pressure distribution over the wing surface.

Daniel Cellucci↗

Embedded Data Acquisition Tools for Rotorcraft Diagnostic Sensors

Rotorcraft drive trains must withstand enormous pressure while operating continuously in extreme temperature and vibration environments. Captive components, such as planetary and spiral bevel gears, see enormous strain but are not accessible to fixed instrumentation, such as a piezoelectric transducer. Thus, it is difficult to directly monitor components that are most susceptible to damage. This innovation is a self-contained data processing unit within a specialized fixture that installs directly inside the rotating pinion gear in the gearbox. From this location, it detects and transmits high-resolution prognostic data to a fixed transceiver. The sensor is based on microelectromechanical systems (MEMS) technology and uses innovative circuit designs to capture high-bandwidth data and transmit it wirelessly from inside an operational helicopter transmission. With Ridgetop's advanced MEMS-based sensor, researchers have, for the first time, been able to extract high-resolution acoustic signatures wirelessly from sensors within the transmission that would otherwise be muffled by background gear noises. Ridgetop's innovative instrument will help researchers perform dynamic analysis of gear interaction and develop improved designs for gear components. In addition, data from this instrument can be used to validate new algorithms that detect and predict faults based on external acoustic signatures, for prognostic purposes. The result of this work will be an improvement in safety, performance, and cost for future generations of rotating components.

Wagoner, Robert↗

Simulation, Challenge Testing and Validation of Solutions for Residential and Commercial Occupancy Sensing/Counting and CO2 Sensing (Final Report)

Carbon dioxide sensors used for monitoring and control applications in buildings are known to be sensitive to long term drift and can be affected by variations in temperature, humidity, other gas interferents, pressure and other factors that cannot be corrected through the typical auto-calibration methods often embedded in the sensor electronics. This investigation was part of the Category D defined in the ARPA-E Saving Energy Nationwide in Structures With Occupancy Recognition (SENSOR) Financial Assistance Funding Opportunity Announcement No. DE-FOA-0001737, FFDA No. 81.135, January 18, 2017. The FOA defined target criteria for the evaluation of the Category C commercial CO2 sensors selected for review and development through the ARPA-E SENSOR program and charged the Iowa State Category D team with developing an evaluation methodology for Category C sensors in accordance with these criteria. As part of the work, the Iowa State team chose to engage the standards community in the development of the evaluation methodology. Standard development work in the D22.05 Indoor Air and D22.03 Ambient Atmospheres and Source Emissions subcommittees of ASTM International Committee D22 on Air Quality on the evaluation of low cost sensors and provision of guidance for using indoor carbon dioxide concentrations to evaluate indoor air quality and ventilation is of particular relevance to the Category D efforts. To date, three draft standards with specific input by the Iowa State Category D team have passed the subcommittee balloting stage and are being balloted in December 2022 and January 2023 in the main D22 committee. In addition to the aforementioned standards to which the PI was a contributing author, intellectual property developed in this project pertaining to “An Automated System for Evaluation of the Long Term Performance of Carbon Dioxide Sensors” and “An Automated Ground Truth System for Real-Time Reliability Assessment, Capture of Control Decisions and Energy Savings Measurements for Occupancy Recognition Systems and Other Applications” are the other major deliverables of the project. These standards and the developed intellectual property are expected to benefit the public in a number of ways stemming from their provision of means to benchmark the performance of carbon dioxide and other sensor systems. In particular, there is high interest in techniques to demonstrate the performance of low-cost carbon dioxide sensors which can be used for typical HVAC applications (e.g., demand controlled ventilation, outdoor and indoor air monitoring, estimation of occupancy, etc.).

42 ENGINEERING↗

Experimental Investigation of Low-Frequency Distributed Acoustic Sensor Responses to Two Parallel Propagating Fractures

Low-frequency distributed acoustic sensing (LF-DAS) is a diagnostic tool for hydraulic fracture propagation with far-field monitoring using fiber optic sensors. LF-DAS senses strain rate variation caused by stress field change due to fracture propagation. Fiber optic sensors are installed in the monitoring wells in the vicinity of a fractured well. From the strain responses, fracture propagation can be evaluated. To understand subsurface conditions with multiple propagating fractures, a laboratory-scale hydraulic fracture experiment was performed simulating the LF-DAS response to fracture propagation with embedded distributed optical fiber strain sensors under these conditions. The experiment was performed using a transparent cube of epoxy with two parallel radial initial flaws centered in the cube. Fluid was injected into the sample to generate fractures along the initial flaws. The experiment used distributed high-definition fiber optic strain sensors with tight spatial resolutions. The sensors were embedded at two different locations on opposite sides of the initial flaws, serving as observation/monitoring locations. We also employed finite element modeling to numerically solve the linear elastic equations of equilibrium continuity and stress–strain relationships. The measured strains from the experiment were compared to simulation results from the finite element model. The experimentally derived strain and strain-rate waterfall plots from this study show the responses to both fractures propagating, while the fracture at the lower position took most of the fluid during the experiment. Interestingly, a fracture first began propagating from the upper flaw of the two flaws, but once the lower fracture was initiated, it grew much faster than the upper fracture. Both fibers were intercepted by the lower fracture, further verifying the strain signature as a fracture is approaching and intersecting an offset fiber.

Chemistry↗

Development of Optical Step Height Measurement Capability for the BOLT Flight Vehicle

This paper presents details on the development of testing procedures to evaluate two different optical step height sensors that were intended for use on the first and second Boundary Layer Transition (BOLT and BOLT II) flight vehicle as well as other flight vehicles. The accurate and precise measurement of step height at the interface of different sections of a flight vehicle is important, as small changes in the step height (in some instances < 10 microns) at such locations can have a significant influence on the development of a boundary layer over the outer surface of the vehicle, which in turn can significantly impact aeroheating (among other things). In this paper, testing procedures have been developed, and test hardware assembled, to determine the capabilities of two optical step height sensor candidates. The first candidate is a miniaturized camera sensor that would be embedded into the body of a flight vehicle and would image the interface between two sections of that vehicle. The second candidate is a small fiber-based optical sensor that would also be embedded into the body of the flight vehicle, but projects light onto the interface between two sections of the flight vehicle, and then monitors any reflected/scattered light from that interface. Preliminary data from these two sensor candidates are presented, and a discussion of improvements that will be made in the testing procedures and to the test hardware is provided.

Brett F Bathel↗

Self-Sensing Composites via an Embedded 3D-Printed PVDF-MoS 2 Nanosensor for Structural Health Monitoring

Carbon fiber (CF)-reinforced epoxy composites are widely used in vehicle applications, where early damage detection is crucial for reliability and safety. To address this need, we developed a self-sensing epoxy/CF composite by embedding a PVDF-MoS 2 nanosensor via an embedded 3D printing method. By harnessing the intrinsic curing kinetics of epoxy, we tailored its rheological properties to optimize the embedded printing process, enabling precise and reliable support for sensor filaments without compromising the composite’s structural and functional integrity. Through comprehensive rheological and kinetic analysis, we established a quantitative relationship among curing temperature, conversion rate, and resulting yield modulus─defining a narrow processing window essential for successful sensor integration. Specifically, we identified that an epoxy yield modulus range of 180–294 Pa and a conversion rate below 10% are critical to support the PVDF-MoS 2 filament architecture. Here, this embedded 3D printing method produces complex and multimaterial PVDF-MoS 2 sensors within an epoxy matrix with minimal deformation and reduced postprocessing, which is scalable and adaptable for industrial applications. Under cyclic loading, the embedded sensors exhibited stable signals under constant loads and increased voltage signals in response to crack formation (17–35% higher) and catastrophic failure (1 order of magnitude higher), effectively capturing structural changes in real time. This study demonstrates the potential of PVDF-MoS 2 nanocomposite sensor materials for real-time structural health monitoring in epoxy–CF composite systems, enabling early detection of defects and stress anomalies, significantly reducing the risk of unexpected failures, and enhancing structural reliability.

PVDF-MoS2 sensor↗

Mechanical properties, strain hardening, and fracture behavior of ultrasonic additively manufactured Zircaloy-4 after low-temperature neutron irradiation

Ultrasonic additive manufacturing (UAM) is a solid-state, layer-by-layer advanced manufacturing process that has the potential to create custom spatially controlled composites with embedded wires and sensors for nuclear component manufacture. For this work, to assess the feasibility of using UAM for nuclear-relevant materials research, the technique was used to produce a 3.5-mm-thick Zircaloy-4 plate for irradiation testing. The UAM Zircaloy-4 specimens were irradiated in the High Flux Isotope Reactor at a target irradiation temperature of 117 °C to 2.9 displacements per atom (dpa) to assess differences in irradiation-hardening behavior as a function of alloy processing path. The UAM and reference baseplate (BP) materials increased in yield strength by 372±27 MPa and 346±21 MPa, respectively, and both suffered significant reductions in uniform and total elongation attributed to irradiation hardening at low-temperature. Although the materials had similar nanoscale defect structures, including nanoscale black dot/loop features and strain-induced dislocation channels, the UAM material’s processing-related defects resulted in accelerated strain localization and failure as demonstrated by lower post-irradiation uniform elongation of UAM specimens (0.5 %) compared to BP (1.5 %) material. The UAM material also showed considerable anisotropy in mechanical response due to crack propagation along weld boundaries, resulting in differences in strength & ductility when tested parallel and perpendicular to the prior UAM build orientation. Therefore, although the fundamental irradiation response of UAM-processed Zircaloy-4 was phenomenologically comparable to that of BP reference material, additional optimization of the UAM processing is needed to produce irradiation-resistant and nuclear-relevant materials.

Digital image correlation↗