Flexible Grid Interconnections

Key Considerations: - Long-term coordination and collaboration with utilities and ISOs may provide mutual benefits and support flexible interconnectivity. - Onsite storage and energy production can reduce load fluctuations and support grid resilience in the future. - Geography and resource availability can impact energy demand and grid flexibility.

29 - ENERGY PLANNING, POLICY AND ECONOMY↗

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Software defined grid energy storage

Today, consumer battery installations are isolated, physical devices. Virtual power plants (VPPs) allow consumer devices to aggregate for grid services, but they are are vertically integrated, vendor controlled systems (e.g., Tesla’s VPP). Consumer batteries are therefore unable to participate in energy markets or other grid services outside what their vendor provides. We describe a software system that provides software control of multiple, networked battery energy storage systems in the electric grid. The system introduces two new ideas that enable flexible and dependable management of energy storage. The first is a virtual battery, which can either partition a battery or aggregate multiple batteries. The second is a reservation-based API which allows asynchronous control of batteries to meet contractual guarantees in a safe and dependable manner. Virtual batteries and a reservation-based API address the unique challenges of achieving high and efficient utilization of energy storage systems, including heterogeneity of battery systems such as varying C-rates, participation in energy markets, utility bill management systems, community resource sharing, and reliability. Using a testbed comprised of sonnen Inc. storage units installed in several homes and a lab, we demonstrate that virtualized batteries can seamlessly replace physical batteries, flexibly manage energy storage resources, isolate multiple clients using a shared battery, and create new energy storage applications.

25 ENERGY STORAGE↗

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

Optimizing Grid-interactive Efficient Building Designs with Stacked Value Streams

Grid-interactive efficient buildings (GEBs) are those characterized by the combination of energy efficiency and demand flexibility with smart technologies and communications to not only deliver greater affordability and comfort to buildings, but also help utilities manage grid operations and lower system costs. This paper presents an innovative techno-economic assessment framework to effectively examine different GEB design options, explore various use cases, define technically achievable benefits, and thereby assist in informed decision-making. In particular, building load flexibility, thermal storage, and battery energy storage are considered. Advanced optimal dispatch problem is formulated to maximize the stacked value streams from multiple, competing use cases, subject to the physical capabilities and operational flexibility associated with different designs and configurations. Comprehensive case studies were performed for a real-world building to evaluate the cost-effectiveness of different GEB designs and offer in-depth insights. It was found that the proposed assessment method could effectively capture the costs and benefits linked to each GEB design option. Furthermore, the study revealed that outage mitigation and demand response are the two most significant sources of benefits for GEBs.

Ma, Xu↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unleash Values From Grid-Edge Flexibility: An Overview, Experience, and Vision for Leveraging Grid-Edge Distributed Energy Resources to Improve Grid Operations

The power system landscape is presently undergoing a dramatic change with the rapid integration of numerous distributed energy resources (DERs) at the grid edge. Broadly, we consider grid-edge DERs as any electricity source, storage, and demand response program connected to the medium-to-low-voltage distribution system.

distributed energy resource↗

Energy Arbitrage with Hydrogen: HTSE + Combustion Turbine

The Light Water Reactor Sustainability (LWRS) program seeks to keep Nuclear Power Plants (NPPs) competitive in the changing energy market. The Flexible Plant Operation and Generation (FPOG) pathway investigates Energy Storage Systems (ESS) to give operators an alternative to curtailment or paying to put power on the grid. This work investigates the concept of diverting heat and electricity to High Temperature Steam Electrolysis (HTSE) to produce hydrogen when grid demand is low, storing that hydrogen, then burning it in a combustion turbine to produce zero-emission electricity when grid demand is high. A process model of the combustion turbine was developed in Aspen HYSYS, which was used to complete a parametric analysis and techno-economic analysis.

08 HYDROGEN↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost and Performance Baseline for Fossil Energy Plants, Volume 5: Natural Gas Electricity Generating Units for Flexible Operation

To address the data needs of energy system designers and to serve as a baseline for research and development, NETL has carried out a study to characterize the flexibility attributes - both performance and cost - of nine common commercial natural gas-fueled electricity generating units. The intermittent output of low-carbon, renewable power generation sources such as wind and solar create challenges to grid stability and reliability. Fossil-fueled power generation technologies are currently used to provide reliable, on-demand power during periods of reduced renewable output. Dispatchable generators must be able to accommodate increasing renewable generation as the nation pursues the Administration’s target of a decarbonized energy sector by 2035. As energy system experts seek to identify least-cost approaches to decarbonization, accurate cost and performance data characterizing dispatchable fossil generators that operate flexibly, at capacity factors that have been declining over time, and are needed to inform models for capacity expansion. Furthermore, these technologies continue to be a significant source of carbon dioxide emissions, providing the impetus for research and development, including the advancement and potential incorporation of carbon capture technologies. This study characterizes the cost and performance of select state-of-the-art natural gas-fueled power generation technologies: reciprocating internal combustion engines (RICE), simple cycle combustion turbines, and natural gas combined cycles (NGCC). An emphasis is placed on flexibility characteristics, such as part-load heat rate, ramp rates, start up times, and start up costs.

03 NATURAL GAS↗

Fibrous Materials for Flexible Li–S Battery

The lithium–sulfur (Li–S) battery is an attractive high-energy-density technology for future flexible and wearable electronics, but it is a challenge to simultaneously realize adequate flexibility, stability, and energy density. Recent studies show that fibrous materials are promising to achieve flexible batteries with high energy density, by taking advantages of their intrinsic flexibility, lightweight, large surface area, and cost-effectiveness. With a good tunability of the structure and function, fibrous materials can be suitable to construct various components of a working battery, including current collectors, buffer layers, interlayers, and solid-state electrolytes. In this review, we summarize the recent development of fibrous materials for flexible Li–S batteries, with an emphasis on the discussion of the synthesis and preparation of materials, design of fibrous structures and functionalities, and layout of battery cells for achieving high Coulombic efficiency, long cycle life, and good flexibility.

25 ENERGY STORAGE↗

Resilient buildings for fire-adapted landscapes: EE and flexible loads integrated with solar and storage microgrids

Energy efficiency (EE) and flexible loads can be part of a resilient buildings packagewhen they are combined with solar and storage in a clean energy microgrid to reduce the carbonfootprint of buildings and enable resilience to extreme events. Recent large wildfires and an emerging understanding of the fire-adapted landscapes in the American West underscore the urgency of work towards scaling and commercializing these systems. For example, a recent power shutoff in Northern California (October 9-12, 2019) resulted in 738k customers disconnected at the peak of the outage and is emblematic of challenges to come. Our paper reports on insights from a clean energy microgrid deployment pilot that integrates a 50 kWAC PV array, a 109 kW / 174 kWh battery system, switchgear to safely isolate from the regional power system, and communicating controllers for HVAC and refrigeration. The project will be commissioned in May 2020 and is sited at a critical infrastructure site in rural Northern California – in this case a gasoline station with convenience store. Our experience and results shed light on capabilities of integrated microgrids to provide value to customers during blue sky conditions and resilience during black sky days with high fire risk, and what opportunities and barriers exist for scaling these integrated microgrid systems in the near term. We use a simulation model to estimate how EE and flexibility can extend the run time of solar and storage, improving the reliability of power at critical sites.

Alstone, Peter↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER) With Envelope Improvements and Advanced Air Sealing

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson, et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (GHP) (4.0 COP, 20.5 EER) With Envelope Improvements. This measure combines a two-stage GHP with envelope improvements as a single package. As this package is a combination of two other measures, this document focused on documenting the results associated with this combination of technologies, with individual measure documents for two-stage GHPs and envelope improvements providing the information on the details of these measures. When the two technologies are combined, envelope improvements can modestly reduce energy consumption by a further 10%-15%, but also reduce the required size of the ground heat exchanger and heat pump by approximately 33% on average across all sites. The cost of installing envelope improvements in these homes is likely to be more than paid for by the reduction in equipment and drilling costs in these buildings for the majority of the stock.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Single-Stage Geothermal Heat Pump (3.8 COP, 18.6 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Single-Stage Geothermal Heat Pump (GHP).?Single-stage GHPs are able to reduce energy consumption by 31% for the entire stock. Additional results provided below detail how savings changes for sections of the housing stock with different base heating fuel and in different climate zones, as well as the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This document focuses on a single end-use savings shape measure: Residential Two-Stage Geothermal Heat Pump (4.0 COP, 20.5 EER). This document builds on details established in the single-stage document (Maguire et al. 2025) to detail differences in the approach to modeling this higher efficiency, but more commonly deployed, type of geothermal heat pump. Specific EnergyPlus objects and product specific curves used are highlighted along with showing the results of this measure compared to the baseline and single-speed geothermal heat pumps. Two-speed geothermal heat pumps are able to save even more energy and on utility bills than single-speed products, albeit at the expense of a higher first cost.

15 GEOTHERMAL ENERGY↗

ResStock Measure Documentation: Residential Variable-Speed Geothermal Heat Pump (4.4 COP, 30.9 EER)

The goal of this work is to develop energy efficiency, demand flexibility, and other retrofit end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to retrofits that can be applied to buildings during modeling. An "end-use savings shape" is the difference in energy consumption between a baseline building and a building with an energy efficiency, demand flexibility, or other retrofit measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ResStock (TM) is a highly granular, physics-based, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the residential building stock across the United States. The baseline model intends to represent the U.S. residential building stock as it existed in 2018. Technical documentation for the inputs and assumptions in the baseline building stock model is available in Reyna et al. (2025). Calibration and validation of the baseline model results are available in the final technical report of the End-Use Load Profiles project (Wilson et al. 2022). This documentation focuses on a single end-use savings shape measure: Residential Variable-Speed Geothermal Heat Pump (GHP). This document provides the relevant new modeling information for variable-speed systems not previously covered in either the single-stage or two-stage documents. Variable-speed GHPs represent the most efficient option available for this technology: They provide the most savings, with up to 46% for the applicable portion of the housing stock, compared to 31% for less efficient single-stage GHPs. Additional results shown here detail how the savings change for sections of the housing stock with different base heating fuels and in different climate zones, and they show the savings potential by state for both heating and cooling. Utility bills and electric panel impacts are also shown and discussed.

15 GEOTHERMAL ENERGY↗

Conceptual Design of Pulverized Coal Electricity Generating Units for Flexible Operation

This National Energy Technology Laboratory (NETL) study addresses the conceptual design of greenfield pulverized coal (PC) plants intended for flexible rather than high capacity factor baseload operation. The United States has plentiful, low-cost natural gas resources - studies of aggressive decarbonization scenarios of the US energy sector suggest that the variability of carbon-free power can be economically addressed using dispatchable natural gas-fueled generation. Globally, natural gas resources are not as plentiful or low cost; consequently, some regions of the world are anticipated to continue to rely upon coal generation, even as they pursue decarbonization efforts. To support the increased utilization of variable renewable generation in these coal-dependent regions, plant designs must target low-capacity factor coal plants with increased emphasis on flexibility attributes such as start-up times, ramp rates, minimum load, and part-load heat rates. While much work has been performed on the improvement of the flexibility for existing coal plants originally designed for baseload service, little public literature exists on clean sheet design for flexible operation. This conceptual design study aims to define the features, performance characteristics, and costs for greenfield coal plants intended for flexible operation. Quantifying these characteristics provides critical information required by utility owners, grid planners, energy market modelers, and energy policy decision makers in coal-dependent regions of the world to better understand how coal-fired power plants can support a transition to low carbon generation.

20 FOSSIL-FUELED POWER PLANTS↗