Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental measure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Neutron Capture and Transmission Measurements of 54 Fe at the RPI LINAC

54 Fe radiative capture cross section and transmission measurements were conducted at the Rensselaer Polytechnic Institute (RPI) Gaerttner Linear Accelerator (LINAC) Center using an enriched 54 Fe sample in the keV energy region. 54 Fe is a constituent of natural iron, which is present in a large variety of nuclear grade materials. Therefore, it is important to have an accurate understanding of the cross sections of 54 Fe, which can be measured experimentally. In the time-of-flight measurements conducted at the LINAC, an array of four C 6 D 6 detectors surrounded the sample and radiative capture data were collected using a digital data acquisition system. Additionally, a Li-glass detector was used to collect transmission data using an analog data acquisition system. The radiative capture yield of the 54 Fe measurements were normalized to saturated resonances observed in Au and Ta to obtain an absolute capture yield. The preliminary capture yield and preliminary transmission obtained can be compared to evaluations and existing experimental data. Some disagreements were observed in prominent d-wave capture resonances observed in 54 Fe in the low-keV neutron energy region. Both sets of experimental data along with pre-existing datasets will greatly enhance RPI’s ability to perform resonance evaluation for 54 Fe up to roughly 1 MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reaction Pathways and Energy Consumption in NH 3 Decomposition for H 2 Production by Low Temperature, Atmospheric Pressure Plasma

Pathways for NH 3 decomposition to N 2 and N 2 H 4 by atmospheric pressure nonthermal plasma are analyzed using a combination of molecular beam mass spectrometry measurements and zero-dimensional kinetic modeling. Experimental measurements show that NH 3 conversion and selectivity towards N 2 formation scale monotonically with the specific energy input into the plasma with ~ 100% selectivity to N 2 formation achieved at specific energy inputs above 0.12 J cm −3 (3.1 eV (molecule NH 3 ) −1 ). The kinetic model recovers these trends, although it underpredicts N 2 selectivity at low specific energy input. These discrepancies can be explained by the underestimation of reaction rate coefficients for reactions that consume N 2 H x species in collisions with H radicals and/or radial nonuniformities in power deposition, gas temperature, and species concentrations that are not represented by the plug flow approximation used in the model. The kinetic model shows that N 2 formation proceeds through N 2 H x decomposition pathways rather than NH x decomposition pathways in low temperature, atmospheric pressure plasma. Higher selectivity toward N 2 production can be achieved by operating at higher NH 3 conversion and with a higher gas temperature. Furthermore, the high energy cost of NH 3 decomposition by atmospheric pressure nonthermal plasma found in this work (25–50 eV (molecule NH 3 converted) −1 ; 17–33 eV (molecule H 2 formed) −1 ) is a result of the energy requirement for electron-impact dissociation of NH 3 and the significant re-formation of NH 3 by three-body recombination reactions between NH 2 and H.

Nonthermal plasma↗

Linking Pressure to Electrochemical Evolution in Solid-State Conversion Cathode Composites

Conversion-type cathodes, such as sulfur, FeS 2 , and FeF 3 , offer high theoretical capacities in solid-state lithium batteries but are hindered by substantial volume changes during cycling, leading to interfacial contact loss, crack formation, and microstructural degradation. Here, we investigate the relationships between electrochemical, mechanical, and structural evolution in solid-state electrode composites with these three active materials. Using real-time stack-pressure monitoring, synchrotron X-ray absorption spectroscopy, and electrokinetic modeling, we elucidate how stress evolution is linked to reversible and irreversible redox reactions. Nonlinear stack pressure evolution in cells with sulfur, FeS 2 , and FeF 3 electrode composites is found to arise from material-specific volume changes, the balance of volume change between the working and counter electrode, and the formation of distinct reaction intermediates. The three materials exhibit distinct stack pressure evolution, which is closely related to the different reaction processes in the materials, as demonstrated with X-ray absorption spectroscopy measurements. Through mesoscale modeling, we relate the experimental measurements to species evolution at the particle scale and track the dynamic coexistence of intermediate phases. Our findings highlight the importance of designing for volume changes of a given active material in solid-state battery systems.

batteries↗

Learning protein fitness models from evolutionary and assay-labeled data

Machine learning-based models of protein fitness typically learn from either unlabeled, evolutionarily related sequences or variant sequences with experimentally measured labels. For regimes where only limited experimental data are available, recent work has suggested methods for combining both sources of information. Toward that goal, we propose a simple combination approach that is competitive with, and on average outperforms more sophisticated methods. Our approach uses ridge regression on site-specific amino acid features combined with one probability density feature from modeling the evolutionary data. Within this approach, we find that a variational autoencoder-based probability density model showed the best overall performance, although any evolutionary density model can be used. Moreover, our analysis highlights the importance of systematic evaluations and sufficient baselines.

59 BASIC BIOLOGICAL SCIENCES↗

High-fidelity modeling of breakdown in helium: initiation processes and secondary electron emission

Understanding the role of physical processes contributing to breakdown is critical for many applications in which breakdown is undesirable, such as capacitors, and applications in which controlled breakdown is intended, such as plasma medicine, lightning protection, and materials processing. The electron emission from the cathode is a critical source of electrons which then undergo impact ionization to produce electrical breakdown. In this study, the role of secondary electron yields due to photons (γ ph ) and ions (γ i ) in direct current breakdown is investigated using a particle-in-cell direct simulation Monte Carlo model. The plasma studied is a one-dimensional discharge in 50 Torr of pure helium with a platinum cathode, gap size of 1.15 cm, and voltages of 1.2–1.8 kV. The current traces are compared with experimental measurements. Larger values of γ ph generally result in a faster breakdown, while larger values of γ i result in a larger maximum current. The 58.4 nm photons emitted from He(2 1 P) are the primary source of electrons at the cathode before the cathode fall is developed. Of the values of γ ph and γ i investigated, those which provide the best agreement with the experimental current measurements are γ ph = 0.005 and γ i = 0.01. In this work, these values are significantly lower than those in the literature for pristine platinum or for a graphitic carbon film which we speculate may cover the platinum. This difference is in part due to the limitations of a one-dimensional model but may also indicate surface conditions and exposure to a plasma can have a significant effect on the secondary electron yields. The effects of applied voltage and the current produced by a UV diode which was used to initiate the discharge, are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct comparison between experiments and dislocation dynamics simulations of high rate deformation of single crystal copper

A long standing challenge in computational materials science is to establish a quantitative connection between the macroscopic properties of plastic deformation with the microscopic mechanisms of dislocations in crystalline materials. Although the discrete dislocation dynamics (DDD) simulation method has been developed for several decades with the goal of addressing this challenge, a one-to-one comparison between the DDD predictions on single crystal stress–strain curves and experimental measurements under identical conditions has not been possible to date. Such a comparison is an essential step towards establishing a dislocation-physics based theory of plasticity and a multiscale framework of the plastic behaviors of crystalline materials. Here we provide direct comparisons between the stress–strain curves of Cu single crystals under high strain rate loading in the [0 0 1] and [0 1 1] directions obtained from miniaturized desktop Kolsky bar experiments and those from DDD simulations under identical loading conditions. With an appropriate set of parameters, DDD simulations can produce stress–strain curves that are in reasonable agreement with the experimental results. However, the dislocation mobility values needed to achieve this agreement are an order of magnitude lower than expected based on previous measurements and atomistic simulations. We hypothesize that this discrepancy could be caused by drag forces from jogs and point defects produced during the plastic deformation. Cross-slip of screw dislocations is also found to be necessary to capture the experimental stress–strain behavior, especially for the [0 1 1] loading direction. Finally, this work provides an example of how direct comparisons between DDD simulations and experimental measurements can provide new insight into the fundamental mechanisms of plastic deformation.

36 MATERIALS SCIENCE↗

Probing room temperature indirect and minimum direct band gaps of h-BN

Abstract Hexagonal boron nitride (h-BN) has attracted considerable interest as an ultrawide bandgap (UWBG) semiconductor. Experimental studies focused on the detailed near band-edge structure of h-BN at room temperature are still lacking. We report a direct experimental measurement of the near band-edge structure performed on h-BN quasi-bulk wafers via photocurrent excitation spectroscopy (PES). PES resolved the band-to-band transitions near M- and K-points in the Brillion zone (BZ), from which the room temperature indirect band gap of E g M K ∼6.02 eV, minimum direct bandgap at M-point of E g M = 6.36 eV and next lowest direct energy bandgap at K-point of E g K = 6.56 eV , have been simultaneously determined for the first time experimentally. The measured energy differences between K- and M-points in the conduction band minimum (CBM) and valence band maximum (VBM) are Δ E C M K = 0.54 eV and Δ E V M K = 0.34 eV, respectively, in good agreement with the calculation results. Significantly differing from its III-nitride wurtzite counterparts, in which only electrons and holes in the conduction and valence band extremes at the Γ-point are predominantly involved in the optical and transport processes, the results highlighted that charge carriers associated with both M- and K-valleys control to the optical excitation, recombination and charge transport processes in h-BN.

Physics↗

Beam Spin Asymmetry Measurements of Deeply Virtual $π$ 0 Production with CLAS12

The new experimental measurements of beam spin asymmetry were performed for the deeply virtual exclusive $π$ 0 production in a wide kinematic region with the photon virtualities $Q$ 2 up to 8 GeV 2 and the Bjorken scaling variable $x$ $B$ in the valence regime. The data were collected by the CE BAF Large Acceptance Spectrometer (CLAS12) at Jefferson Lab with longitudinally polarized 10.6 GeV electrons scattered on an unpolarized liquid-hydrogen target. Sizable asymmetry values indicate a substantial contribution from transverse virtual photon amplitudes to the polarized structure functions. The interpretation of these measurements in terms of the Generalized Parton Distributions (GPDs) demonstrates their sensitivity to the chiral-odd GPD $\overline{E}$ $T$ , which contains information on quark transverse spin densities in unpolarized and polarized nucleons and provides access to the proton’s transverse anomalous magnetic moment. Additionally, the data were compared to a theoretical model based on a Regge formalism that was extended to the high photon virtualities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FY2022 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

This report describes the development of and experimental measurements made with the thermal conductivity and viscosity measurement systems for molten salts at Oak Ridge National Laboratory. The thermal conductivity system is based on a steady-state measurement technique in which a heat flux is driven across a variable gap, and the changes in temperature difference across the gap are measured as the gap size is varied. The system comprises an inner containment, which possesses the heating element, and an outer containment, which possesses the salt specimen and cooling channels. The gap is formed between the outer bottom of the inner containment and the inner bottom of the outer containment. The viscosity system is based on the falling-ball technique in which a salt-filled tubular crucible is fixed at an angle and a ball rolls through the salt. The terminal velocity of the ball can be converted into viscosity via a calibration factor calculated for crucible-ball combinations which account for thermal expansion and flow characteristics. Modifications were made to both systems this fiscal year. Modifications to the thermal conductivity system included adding guard heaters to prevent axial heating losses, and modifications to the viscosity system included changing the crucible design to prevent air pocket formation and providing the ability to conduct measurements with a glass or steel crucible.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evidence of ordering in Cu-Ni alloys from experimental electronic entropy measurements

Phase diagrams exhibiting extended solid-solution and lenslike melting are often reproduced using ideal solutions, where ideal mixing considers a fully random configurational entropy of mixing. In the field of irreversible thermodynamics, experimental measurements of the composition variation of high-temperature electronic transport and molten-state properties suggest, however, a strong role for short-range atomic ordering in these systems. Herein, measurements of the thermopower and resistivity are reported for Cu-Ni solid solutions as a function of temperature and composition. The electronic transport properties were interpreted with an irreversible thermodynamic framework, revealing a large electronic contribution to the entropy of mixing. By considering a cluster model for the configurational entropy that uses the electronic contribution to inform the existence of ordered associates, we rationalize such a contribution of the electronic entropy with the ideal entropy of mixing commonly used to model such systems. In conclusion, these results suggest that the short-range order of the atoms plays a significant role in both solid and liquid states, even when there are no dominant intermetallic compounds in these alloys.

36 MATERIALS SCIENCE↗

IER-580 CED-3b: Experiment Execution Summary for the Pulsed-Neutron Die-Away Experiments (PNDA) with H 2 O

This report summarizes new experiments performed with H 2 O for IER-580, a testbed for pulsed-neutron die-away (PNDA) experiments at Lawrence Livermore National Laboratory (LLNL). The experiments will become high-quality benchmarksthat serve to optimize and validate thermal neutron scattering laws (TSLs) of H 2 O, which are high-priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). The report presents the details of the measurements conducted in October of 2023, including the experimental set-up (PNDA equipment and H 2 O targets) and all experimentally measured data. The report gives the fitted decay constants for the die-away curves of each target sample. It also provides the tabulated data for the die-away curves in the appendices.

42 ENGINEERING↗

Comparison of Modeled to Measured Spectra using MCNP and GADRAS to Benchmark and Contrast Modeling Limitations

The desire to improve nuclear material detection through portal monitors and other low resolution detectors has led to interest in benchmarking the performance of radiation transport codes. These codes can be used to generate a variety and quantity of spectra that may be cost prohibitive to measure directly. Particular characteristics of typical detection scenarios were isolated to compare the performance of radiation transport codes to laboratory experiments. These benchmark experiments were performed to validate simulations in a number of key areas. These experiments included high areal density configurations in both one- and three-dimensional configurations. In addition, off-angle measurements were conducted to investigate the impact of detector response assumptions on complex geometries, for example where an unknown source is not physically collocated with an apparent hot spot. Furthermore, by examining both simple shielding and backscatter configurations, isolation of the scatter emanating from the object and environmental background scatter contributions to the spectra could be elucidated. A series of experiments were performed in which the order of shielding layers and the thickness were evaluated to examine the ability of the simulations to address these variables. Experiments with increasing thickness of polyethylene around a neutron source also allows for examinations of the ability of the transport simulations to properly model n,γ reactions. Finally, depleted uranium (DU) measurements have more complicated spectra than the cobalt-60 and consequently allow for investigations into the ability of transport simulations to model self-shielding. In each case, the results of the experiments were compared to MCNP simulations to judge the performance of the code, as was done previously with GADRAS 18.7.9 simulations [7]. All of the benchmark measurements were taken with a liquid nitrogen cooled 140% high purity germanium (HPGe) detector with a bismuth collimator that had the front tin filter removed. The measurement location and detector configuration were subsequently used for all experimental configurations. The remainder of this report details the experimental measurements, Section 2 and the MCNP model, Section 3. Comparisons between the experimental results and MCNP-generated spectra are performed, Section 4. Section 5 compares the results obtained with MCNP with the previously reported results obtained with GADRAS [2]. Finally, Section 6 presents the conclusions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Impulse response measurements of fast scintillator-based current mode detectors

In this study, experimental measurements were performed to characterize the impulse response of seven different gamma ray detector prototypes being considered to be fielded as a current mode diagnostic for neutron-diagnosed subcritical experiments at the Nevada National Security Site (NNSS). For such experiments, the impulse response of the fielded detector is required to have a full-width half-maximum (FWHM) of approximately 5 ns or less and a low amplitude tail. Each of the detector prototypes evaluated in this work were selected based on the potential to meet this performance requirement. An impulse of bremsstrahlung x-rays created from 2 MeV electrons from the NNSS’s Transformational Diagnostics and Imaging, Los Alamos, linear accelerator was measured with each detector. The measured impulse response was evaluated for each detector configuration. A comparison of these impulse responses revealed a relationship between fast timing performance and scintillator material, geometry, surface reflectivity conditions, and photomultiplier tube (PMT) selection. The detector configuration yielding an impulse response with the shortest FWHM of 3.82 ± 0.11 ns and possessing a low amplitude tail was a 5-inch (12.7-cm) diameter, 5-inch (12.7-cm) height cylindrical EJ-399-17-VI liquid scintillator in a black-painted housing coupled to an Adit D798B 5-inch (12.7-cm) PMT by means of a 0.079-inch (0.2-cm) EJ-560 optical coupling pad.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Preorganized Electric Field Leads to Minimal Geometrical Reorientation in the Catalytic Reaction of Ketosteroid Isomerase

Electrostatic interactions play a pivotal role in enzymatic catalysis and are increasingly modeled explicitly in computational enzyme design; nevertheless, they are challenging to measure experimentally. Using vibrational Stark effect (VSE) spectroscopy, we have measured electric fields inside the active site of the enzyme ketosteroid isomerase (KSI). These studies have shown that these fields can be unusually large, but it has been unclear to what extent they specifically stabilize the transition state (TS) relative to a ground state (GS). In the following, we use crystallography and computational modeling to show that KSI’s intrinsic electric field is nearly perfectly oriented to stabilize the geometry of its reaction’s TS. Moreover, we find that this electric field adjusts the orientation of its substrate in the ground state so that the substrate needs to only undergo minimal structural changes upon activation to its TS. This work provides evidence that the active site electric field in KSI is preorganized to facilitate catalysis and provides a template for how electrostatic preorganization can be measured in enzymatic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inference of strength and phase transition kinetics in dynamically-compressed tin

Dynamic compression experiments in condensed matter are of interest in part because they provide opportunities to examine material response under extreme conditions; however, the inference of material behavior from dynamic experiments is challenging in the presence of phase transitions exhibiting kinetic processes. Demonstrating an approach to quantitative interpretation of such dynamic experiments, here we present a Bayesian model calibration of strength and phase transformation parameters to data drawn from pulsed power and gas gun shot experiments. The posterior predictions of the Bayesian model capture the experimental measurements and account for the various uncertainties in the experimental configurations. This holistic approach to model calibration utilizing multiple types of experimental data identifies important cross correlations among kinetics, strength, and the phase boundary. Improved insight into potential sources of current model form error is provided by comparing the differences between calibrations against different subsets of the experimental data.

42 ENGINEERING↗

Double photoionization of atomic oxygen: Feshbach resonances in the two-electron continuum

In this work, we describe a joint experimental and theoretical investigation on oxygen double photoionization—the emission of two electrons from atomic oxygen following single photon absorption. High-resolution experimental measurements were performed at the Advanced Light Source, revealing sharp resonance structure superimposed on the more familiar Wannier-like, nearly-linear background. These resonance features are attributed to ionization-plus-excitation Feshbach resonances embedded in the double ionization continuum, doubly-excited states that lie above the double-ionization threshold. Such features are absent in the double photoionization cross section of He, or other quasi-two-electron systems, for which the doubly-ionized atomic core remains inert. For a corresponding theoretical analysis, the R-matrix with pseudostates (RMPS) method was invoked by calculating final-state, two-electron resonances-plus-continua wavefunctions and corresponding single-photon absorption cross sections. Overall agreement is found in the direct, background double photoionization cross section. However, the RMPS method, using a small basis due to practical computational limitations, was unable to reproduce quantitatively the smooth background or the sharper resonance features observed in the measurements, showing instead large-scale oscillations about the experimental background, and characteristic pseudoresonance jitter, associated with an insufficient convergence of the pseudostate representation to the true two-electron infinite series of Feshbach resonances embedded in the two-electron continuum. The prominent resonance structure observed highlights the need to consider multiple excitation processes in atoms more complex than He or quasi-two-electron systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Retrieval of the molecular orientation distribution from atom-pair angular distributions

Imaging laser-induced rotational dynamics is an important and active field due to its applications in capturing reactions in the molecular frame and in molecular imaging. Experimental measurement of the molecular orientation distribution, as a function of the Euler angles, has only been demonstrated for special cases when the detectable signal is generated along the molecular symmetry axis. Here we developed the general theory that maps the probability density distribution of the molecular orientation to the atom-pair angular distributions for nonlinear molecules. With the theory, the molecular orientation distribution can be retrieved from the measured atom-pair angular distribution, which we demonstrate experimentally using ultrafast electron diffractive imaging of impulsively aligned trifluoro-iodomethane molecules. Here, the retrieved molecular orientation distribution is in good agreement with direct numerical simulations of the time-dependent Schrodinger equation using the experimental conditions. Unlike the existing retrieval methods, the retrieval method does not require solving Schrodinger equation, works for any alignment method, and is in principle applicable to asymmetric top molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sensitivity of Thermal Predictions to Uncertain Surface Tension Data in Laser Additive Manufacturing

To understand the process-microstructure relationships in additive manufacturing (AM), it is necessary to predict the solidification characteristics in the melt pool. This study investigates the influence of Marangoni driven fluid flow on the predicted melt pool geometry and solidification conditions using a continuum finite volume model. A calibrated laser absorptivity was determined by comparing the model predictions (neglecting fluid flow) against melt pool dimensions obtained from single laser melt experiments on a nickel super alloy 625 (IN625) plate. Using this calibrated efficiency, predicted melt pool geometries agree well with experiments across a range of process conditions. When fluid mechanics is considered, a surface tension gradient recommended for IN625 tends to overpredict the influence of convective heat transfer, but the use of an intermediate value reported from experimental measurements of a similar nickel super alloy produces excellent experimental agreement. Despite its significant effect on the melt pool geometry predictions, fluid flow was found to have a small effect on the predicted solidification conditions compared to processing conditions. We find that this result suggests that under certain circumstances, a model only considering conductive heat transfer is sufficient for approximating process-microstructure relationships in laser AM. Extending the model to multiple laser passes further showed that fluid flow also has a small effect on the solidification conditions compared to the transient variations in the process. Furthermore, limitations of the current model and areas of improvement, including uncertainties associated with the phenomenological model inputs are discussed.

36 MATERIALS SCIENCE↗