A parametric analysis of oilfield design factors affecting the detectability and characterization of electrically conductive hydrofracks

Electrical responses in the vicinity of energized steel-cased well sources offer significant potential for monitoring induced fractures. However, the high complexity of well-fracture-host models spanning multiple length scales compels analysts to simplify their numerical models due to enormous computational costs. This consequently limits our understanding regarding monitoring capabilities and the limitations of electrical measurements on realistic hydraulically fracturing systems. In this paper, we use the hierarchical finite element approach to construct geoelectric models in which geometrically complex fractures and steel-cased wells are discretely represented in 3D conducting media without sacrificing the model realism and computation efficiency. We have discovered systematic numerical analyses of the electrical responses to evaluate the influences of borehole material conductivity and the source type as well as the effects of well geometry, conductivity contrast, source location, fracture growth, and fracture propagation. Furthermore, the numerical results indicate that the borehole material property has a strong control on the electrical potentials along the production and monitoring wells. The monopole source located at a steel-cased well results in a current density distribution that decays away from the source location throughout the well length, whereas the dipole source produces a current density that dominates mainly along the dipole length. Moreover, the conductivity contrast between the fractures and host does not change the overall pattern of the electrical potentials but varies its amplitude. The fracture models near different well systems indicate that the well geometry controls the entire distribution of potentials, while the characteristics of the voltage difference profiles along the wells before and after fracturing are insensitive to the well geometry and the well in which the source is located. Further, the hydraulic-fracturing models indicate that the voltage differences along the production well before and after fracturing have strong sensitivity to fracture growth and fracture set propagation.

58 GEOSCIENCES↗

Laser Welder Startup Capacitor Failure Analysis & Suggested Potential Mitigation Factors [Slides]

On the morning of the failure (Mon 2/23/2023 5 AM), an unclassified Yttrium Aluminum Garnet Laser Welder system was working within operational parameters. However, when another part was positioned for drilling and it was activated, the coolant compressor was heard shutting off by everyone working on the laser. The coolant pump reportedly failed due to blown 5-amp fuses. Since the coolant pump was offline, the laser was automatically placed into an inoperable state. Failure of the coolant pump was due to a failed capacitor in the startup circuit for the pump.

42 ENGINEERING↗

Electrophoretic concentration of DNA at nanoporous polymer membranes for separations and diagnostics.

We report on the use of thin ({approx}30 micron) photopatterned polymer membranes for on-line preconcentration of single- or double-stranded DNA samples prior to electrophoretic analysis. Shaped UV laser light is used to quickly ({approx}10 seconds) polymerize a highly crosslinked polyacrylamide plug. By applying an electric field across the membrane, DNA from a dilute sample can be concentrated into a narrow zone (<100 micron wide) at the outside edge of the membrane. The field at the membrane can then be reversed, allowing the narrow plug to be cleanly injected into a separation channel filled with a sieving polymer for analysis. Concentration factors >100 are possible, increasing the sensitivity of analysis for dilute samples. We have fabricated both neutral membranes (purely size-based exclusion) as well as anionic membranes (size and charge exclusion), and characterized the rate of preconcentration as well as the efficiency of injection from both types of membrane, for DNA, ranging from a 20 base ssDNA oligonucleotide to >14 kbp dsDNA. We have also investigated the effects of concentration polarization on device performance for the charged membrane. Advantages of the membrane preconcentration approach include the simplicity of device fabrication and operation, and the generic (non-sequence specific) nature of DNA capture, which is useful for complex or poorly characterized samples where a specific capture sequence is not present. The membrane preconcentration approach is well suited to simple single-level etch glass chips, with no need for patterned electrodes, integrated heaters, valves, or other elements requiring more complex chip fabrication. Additionally, the ability to concentrate multiple charged analytes into a narrow zone enables a variety of assay functionalities, including enzyme-based and hybridization-based analyses.

59 BASIC BIOLOGICAL SCIENCES↗

ESTIMATES OF DENSITIES AND FILLING FACTORS FROM A COOLING TIME ANALYSIS OF SOLAR MICROFLARES OBSERVED WITH RHESSI

We use more than 4500 microflares from the RHESSI microflare data set to estimate electron densities and volumetric filling factors of microflare loops using a cooling time analysis. We show that if the filling factor is assumed to be unity, the calculated conductive cooling times are much shorter than the observed flare decay times, which in turn are much shorter than the calculated radiative cooling times. This is likely unphysical, but the contradiction can be resolved by assuming that the radiative and conductive cooling times are comparable, which is valid when the flare loop temperature is a maximum and when external heating can be ignored. We find that resultant radiative and conductive cooling times are comparable to observed decay times, which has been used as an assumption in some previous studies. The inferred electron densities have a mean value of 10{sup 11.6} cm{sup -3} and filling factors have a mean of 10{sup -3.7}. The filling factors are lower and densities are higher than previous estimates for large flares, but are similar to those found for two microflares by Moore et al.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of thin CdTe solar cells with a CdSeTe front layer

Thin CdTe photovoltaic device efficiencies show significant improvement with the incorporation of a CdSeTe alloy layer deposited between a MgZnO emitter and CdTe absorber. CdTe and CdSeTe/CdTe devices fabricated by close-space sublimation with a total absorber thickness of 1.5 µm are studied using microscopy measurements and show minimal diffusion of Se into the CdTe. Current loss analysis shows that the CdSeTe layer is the primary absorber in the CdSeTe/CdTe structure, and fill factor loss analysis shows that ideality-factor reduction is the dominant mechanism of fill factor loss. Improvement in the CdSeTe/CdTe absorber quality compared to CdTe is also reflected in spectral and time-resolved photoluminescence measurements. Current density vs. voltage measurements show an increase in current density of up to 2 mA/cm 2 with the addition of CdSeTe due to a band gap shift from 1.5 to 1.42 eV for CdTe and CdSeTe/CdTe absorbers respectively. Voltage deficit is lower with the incorporation of the CdSeTe layer, corroborated by improved electroluminescence intensity. Here, the addition of CdSeTe into CdTe device structures has increased device efficiencies from 14.7% to 15.6% for absorbers with a total thickness less than two microns.

14 SOLAR ENERGY↗

Initial Systems-Level Assessment of a Distributed Direct Air Capture System Concept at the Urban-scale (UrbanDAC)

Direct Air Capture (DAC) systems offer a promising solution for mitigating global carbon emissions by directly removing ambient carbon dioxide (CO 2 ) from the atmosphere. While future DAC facilities are typically envisioned as being large and centralized, small-scale systems present an alternative approach with advantages such as adaptability and lower uptake costs. By harnessing waste heat from the built environment, such small-scale systems become distributed DAC at the urban scale (UrbanDAC) that benefit from existing urban infrastructure, while presenting challenges such as identifying eligible buildings and sustainable transportation and storage of captured CO 2 . Collaborating with engineering experts and developers of a DAC unit that can be co-located with cooling towers of existing commercial buildings, this study explores the systems-level implications of UrbanDAC using a geographically explicit multi-decision criteria analysis (MCDA) framework. By considering various infrastructure and environmental factors, network analysis and geospatial techniques are applied to identify optimal building candidates for distributed DAC units within Knoxville, Tennessee, USA, as a representative mid-size city. The selected outputs of the MCDA are used to explore a scenario that assumes a CO 2 collection and transport route for 20 high-ranking candidate buildings; total carbon emissions, EV energy consumption, and net carbon dioxide removal (CDR) are then calculated. Results suggest that the spatial variation of optimal candidates between thriving commercial areas is an important planning consideration. Examining the feasibility of UrbanDAC at an urban planning level provides valuable insights into the barriers and enabling conditions for CDR in cities, where the vast majority of CO 2 emissions are produced, and supports decision-making processes for the implementation of decarbonization initiatives. Through this initial assessment, this research acts as a pilot study for an emerging technology that highlights the importance of distributed DAC technologies in addressing climate change and emphasizes the need for further research and exploration in this domain.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Delayed Complications in Patients Surviving at Least 3 Years After Stereotactic Radiosurgery for Brain Metastases

Purpose: Little is known about delayed complications after stereotactic radiosurgery in long-surviving patients with brain metastases. We studied the actual incidence and predictors of delayed complications. Patients and Methods: This was an institutional review board-approved, retrospective cohort study that used our database. Among our consecutive series of 2000 patients with brain metastases who underwent Gamma Knife radiosurgery (GKRS) from 1991-2008, 167 patients (8.4%, 89 women, 78 men, mean age 62 years [range, 19-88 years]) who survived at least 3 years after GKRS were studied. Results: Among the 167 patients, 17 (10.2%, 18 lesions) experienced delayed complications (mass lesions with or without cyst in 8, cyst alone in 8, edema in 2) occurring 24.0-121.0 months (median, 57.5 months) after GKRS. The actuarial incidences of delayed complications estimated by competing risk analysis were 4.2% and 21.2% at the 60th month and 120th month, respectively, after GKRS. Among various pre-GKRS clinical factors, univariate analysis demonstrated tumor volume-related factors: largest tumor volume (hazard ratio [HR], 1.091; 95% confidence interval [CI], 1.018-1.154; P=.0174) and tumor volume {<=}10 cc vs >10 cc (HR, 4.343; 95% CI, 1.444-12.14; P=.0108) to be the only significant predictors of delayed complications. Univariate analysis revealed no correlations between delayed complications and radiosurgical parameters (ie, radiosurgical doses, conformity and gradient indexes, and brain volumes receiving >5 Gy and >12 Gy). After GKRS, an area of prolonged enhancement at the irradiated lesion was shown to be a possible risk factor for the development of delayed complications (HR, 8.751; 95% CI, 1.785-157.9; P=.0037). Neurosurgical interventions were performed in 13 patients (14 lesions) and mass removal for 6 lesions and Ommaya reservoir placement for the other 8. The results were favorable. Conclusions: Long-term follow-up is crucial for patients with brain metastases treated with GKRS because the risk of complications long after treatment is not insignificant. However, even when delayed complications occur, favorable outcomes can be expected with timely neurosurgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis Report for Determination of pH Correction Factors for Brines under AP-157 Rev.1

This Analysis Report (AR) documents the determination of pH correction factors for the observed pH readings. The correction factor converts the observed pH reading recorded from the brines used in geochemical studies in support of the Waste Isolation Pilot Plant (WIPP) to a corrected pH value. The data analysis in this AR falls under AP-157 Rev. 1 Analysis Plan for Determination of pH Correction Factors in Brines (Kirkes et al, 2021). Measurement of pH in some solutions can be challenging due to numerous factors such as high ionic strength, elevated or lowered temperature, complex matrix composition, etc. (Knauss et al., 1990; and Rai et al., 1995). The measured pH can be corrected by applying the correction factor, empirically obtained from a specific test solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factors Influencing Electric Bike Share Ridership: Analysis of Park City, Utah

In recent years, bike share programs have become more popular as they contribute to the move toward sustainable mobility in cities. Electric bike sharing, however, remains in the early stages of development. In contrast to traditional bikes, electric bicycles (e-bikes) provide an extra boost via an electric pedal-assist motor, thereby making it much easier to travel around a city with a hilly terrain, such as Park City, Utah. The Summit Bike Share system in Park City is the nation’s first fully electric bike share system (e-BSS). Based on an analysis of historical trip data of Summit Bike Share, this paper presents the system’s performance experience and evaluates user characteristics and travel behavior. A Poisson regression analysis is performed to investigate the factors that influence the e-bike share usage of this e-BSS. The regression results reveal that weather factors, including temperature and wind speed, significantly affect e-bike share usage. It was also found that weekends, summer months, high population density, proximity to public transit centers, recreational centers, and bike trails positively affect the demand for e-bikes. The findings of this paper can help the operators of Summit Bike Share to better understand their users and their e-BSS, while also providing a guide for other e-bike projects currently in the planning stages.

Engineering↗

Effect of Tumor Subtype on Survival and the Graded Prognostic Assessment for Patients With Breast Cancer and Brain Metastases

Purpose: The diagnosis-specific Graded Prognostic Assessment (GPA) was published to clarify prognosis for patients with brain metastases. This study refines the existing Breast-GPA by analyzing a larger cohort and tumor subtype. Methods and Materials: A multi-institutional retrospective database of 400 breast cancer patients treated for newly diagnosed brain metastases was generated. Prognostic factors significant for survival were analyzed by multivariate Cox regression and recursive partitioning analysis (RPA). Factors were weighted by the magnitude of their regression coefficients to define the GPA index. Results: Significant prognostic factors by multivariate Cox regression and RPA were Karnofsky performance status (KPS), HER2, ER/PR status, and the interaction between ER/PR and HER2. RPA showed age was significant for patients with KPS 60 to 80. The median survival time (MST) overall was 13.8 months, and for GPA scores of 0 to 1.0, 1.5 to 2.0, 2.5 to 3.0, and 3.5 to 4.0 were 3.4 (n = 23), 7.7 (n = 104), 15.1 (n = 140), and 25.3 (n = 133) months, respectively (p < 0.0001). Among HER2-negative patients, being ER/PR positive improved MST from 6.4 to 9.7 months, whereas in HER2-positive patients, being ER/PR positive improved MST from 17.9 to 20.7 months. The log-rank statistic (predictive power) was 110 for the Breast-GPA vs. 55 for tumor subtype. Conclusions: The Breast-GPA documents wide variation in prognosis and shows clear separation between subgroups of patients with breast cancer and brain metastases. This tool will aid clinical decision making and stratification in clinical trials. These data confirm the effect of tumor subtype on survival and show the Breast-GPA offers significantly more predictive power than the tumor subtype alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Factorization for azimuthal asymmetries in SIDIS at next-to-leading power

Differential measurements of the semi-inclusive deep inelastic scattering (SIDIS) process with polarized beams provide important information on the three-dimensional structure of hadrons. Among the various observables are azimuthal asymmetries that start at subleading power, and which give access to novel transverse momentum dependent distributions (TMDs). Theoretical predictions for these distributions are currently based on the parton model rather than a rigorous factorization based analysis. Working under the assumption that leading power Glauber interactions do not spoil factorization at this order, we use the Soft Collinear Effective Theory to derive a complete factorization formula for power suppressed hard scattering effects in SIDIS. This yields generalized definitions of the TMDs that depend on two longitudinal momentum fractions (one of them only relevant beyond tree level), and a complete proof that only the same leading power soft function appears and can be absorbed into the TMD distributions at this order. We also show that perturbative corrections can be accounted for with only one new hard coefficient. Factorization formulae are given for all spin dependent structure functions which start at next-to-leading power. Prospects for improved subleading power predictions that include resummation are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Decision-Relevant Factor-Fixing Framework: Application to Uncertainty Analysis of a High-Dimensional Water Quality Model

Factor Fixing (FF) is a common method for reducing the number of model parameters to lower computational cost. FF typically starts with distinguishing the insensitive parameters from the sensitive and pursues uncertainty quantification (UQ) on the resulting reduced-order model, fixing each insensitive parameter at a fixed value. There is a need, however, to expand such a common approach to consider the effects of decision choices in the FF-UQ procedure on metrics of interest. Therefore, to guide the use of FF and increase confidence in the resulting dimension-reduced model, we propose a new adaptive framework consisting of four principles: (a) re-parameterize the model first to reduce obvious non-identifiable parameter combinations, (b) focus on decision relevance especially with respect to errors in quantities of interest (QoI), (c) conduct adaptive evaluation and robustness assessment of errors in the QoI across FF choices as sample size increases, and (d) reconsider whether fixing is warranted. The framework is demonstrated on a spatially-distributed water quality model. The error in estimates of QoI caused by FF can be estimated using a Polynomial Chaos Expansion (PCE) surrogate model. Built with 70 model runs, the surrogate is computationally inexpensive to evaluate and can provide global sensitivity indices for free. For the selected catchment, just two factors may provide an acceptably accurate estimate of model uncertainty in the average annual load of Total Suspended Solids (TSS), suggesting that reducing the uncertainty in these two parameters is a priority for future work before undertaking further formal uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Source Characterization of Volatile Organic Compounds at Carlsbad Caverns National Park

Carlsbad Caverns National Park (CAVE), located in southeastern New Mexico, experiences elevated ground-level ozone (O 3 ) exceeding the National Ambient Air Quality Standard (NAAQS) of 70 ppbv. It is situated adjacent to the Permian Basin, one of the largest oil and gas (O&G) producing regions in the US. In 2019, the Carlsbad Caverns Air Quality Study (CarCavAQS) was conducted to examine impacts of different sources on ozone precursors, including nitrogen oxides (NO x ) and volatile organic compounds (VOCs). Here, we use positive matrix factorization (PMF) analysis of speciated VOCs to characterize VOC sources at CAVE during the study. Seven factors were identified. Three factors composed largely of alkanes and aromatics with different lifetimes were attributed to O&G development and production activities. VOCs in these factors were typical of those emitted by O&G operations. Associated residence time analyses (RTA) indicated their contributions increased in the park during periods of transport from the Permian Basin. These O&G factors were the largest contributor to VOC reactivity with hydroxyl radicals (62%). Two PMF factors were rich in photochemically generated secondary VOCs; one factor contained species with shorter atmospheric lifetimes and one with species with longer lifetimes. RTA of the secondary factors suggested impacts of O&G emissions from regions farther upwind, such as Eagle Ford Shale and Barnett Shale formations. The last two factors were attributed to alkenes likely emitted from vehicles or other combustion sources in the Permian Basin and regional background VOCs, respectively.

54 ENVIRONMENTAL SCIENCES↗

Source characterization of volatile organic compounds at Carlsbad Caverns National Park

Carlsbad Caverns National Park (CAVE), located in southeastern New Mexico, experiences elevated ground-level ozone (O 3 ) exceeding the National Ambient Air Quality Standard (NAAQS) of 70 ppbv. It is situated adjacent to the Permian Basin, one of the largest oil and gas (O&G) producing regions in the US. In 2019, the Carlsbad Caverns Air Quality Study (CarCavAQS) was conducted to examine impacts of different sources on ozone precursors, including nitrogen oxides (NO x ) and volatile organic compounds (VOCs). Here, we use positive matrix factorization (PMF) analysis of speciated VOCs to characterize VOC sources at CAVE during the study. Seven factors were identified. Three factors composed largely of alkanes and aromatics with different lifetimes were attributed to O&G development and production activities. VOCs in these factors were typical of those emitted by O&G operations. Associated residence time analyses (RTA) indicated their contributions increased in the park during periods of transport from the Permian Basin. These O&G factors were the largest contributor to VOC reactivity with hydroxyl radicals (62%). Two PMF factors were rich in photochemically generated secondary VOCs; one factor contained species with shorter atmospheric lifetimes and one with species with longer lifetimes. RTA of the secondary factors suggested impacts of O&G emissions from regions farther upwind, such as Eagle Ford Shale and Barnett Shale formations. The last two factors were attributed to alkenes likely emitted from vehicles or other combustion sources in the Permian Basin and regional background VOCs, respectively. Implications: Carlsbad Caverns National Park experiences ground-level ozone exceeding the National Ambient Air Quality Standard. Volatile organic compounds are critical precursors to ozone formation. Measurements in the Park identify oil and gas production and development activities as the major contributors to volatile organic compounds. Emissions from the adjacent Permian Basin contributed to increases in primary species that enhanced local ozone formation. Observations of photochemically generated compounds indicate that ozone was also transported from shale formations and basins farther upwind. Therefore, emission reductions of volatile organic compounds from oil and gas activities are important for mitigating elevated O 3 in the region.

54 ENVIRONMENTAL SCIENCES↗

Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that vary as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Human Reliability Analysis for Design: Using Reliability Methods for Human Factors Issues

This paper reviews the application of human reliability analysis methods to human factors design issues. An application framework is sketched in which aspects of modeling typically found in human reliability analysis are used in a complementary fashion to the existing human factors phases of design and testing. The paper provides best achievable practices for design, testing, and modeling. Such best achievable practices may be used to evaluate and human system interface in the context of design safety certifications.