Progress on the design of the interaction region of the Electron-Ion Collider EIC

We present an update on the design of the Interaction Region (IR) for the the Electron Ion Collider (EIC) being built at Brookhaven National Laboratory (BNL). The EIC will collide high energy and highly polarized hadron and electron beams with a center of mass energy up to 140 GeV with luminosities of up to 10^34 /cm^2/s. The IR, located at RHIC's IR6, is designed to meet the requirements of the nuclear physics community as outlined in [1]. A second IR is technically feasible but not part of the project.The magnet apertures are sufficiently large to allow desired collision products to reach the far-forward detectors; the electron magnet apertures in the rear direction are chosen to be large enough to pass the synchrotron radiation fan. In the forward direction the electron apertures are large enough for non-Gaussian tails.The paper discusses a number of recent recent changes to the design. The machine free region was recently increased from 9 to 9.5 m to allow for more space in the forward direction for the detector. The superconducting magnets on the forward side now operate at 1.9 K, which helps crosstalk and space issues.

43 PARTICLE ACCELERATORS↗

The Installation of Direct Water-Cooling Systems to Reduce Cooling Energy Requirements for High-Performance Computing Centers

A large cluster of High-Performance Computing (HPC) equipment at the Lawrence Livermore National Laboratory in California was retrofitted with an Asetek cooling system. The Asetek system is a hybrid scheme with water-cooled cold plates on high-heat-producing components in the information technology (IT) equipment, and with the remainder of the heat being removed by conventional air-cooling systems. In order to determine energy savings of the Asetek system, data were gathered and analyzed two ways: using top-down statistical models, and bottom-up engineering models. The cluster, “Cabernet”, rejected its heat into a facilities cooling water loop which in turn rejected the heat into the same chilled water system serving the computer-room air handlers (CRAHs) that provided the air-based cooling for the room. Because the “before” and “after” cases both reject their heat into the chilled water system, the only savings is due to reduction in CRAH fan power. The top-down analysis showed a 4% overall energy savings for the data center (power usage effectiveness (PUE) —the ratio of total data center energy to IT energy— dropped from 1.60 to 1.53, lower is better); the bottom-up analysis showed a 3% overall energy savings (PUE from 1.70 to 1.66) and an 11% savings for the Cabernet system by itself (partial PUE of 1.51). Greater savings, on the order of 15-20%, would be possible if the chilled water system was not used for rejecting the heat from the Asetek system. About 37% of the heat from the Cab system was rejected to the cooling water, lower than at other installations.

Earni, Shankar↗

Evaluation of short-term initial performance of a “Molekule Air” portable air cleaner

The aim of this project was to evaluate and characterize the performance of a MOLEKULE AIR air cleaner unit. The testing protocol comprised the evaluation of an unused Molekule Air unit operating at maximum (“boost” setting) fan speed setting. The device was tested over initial short-term periods of 70-80 h of continuous operation. The tested air cleaner was challenged in separate experiments with a well-characterized mixture of volatile organic compounds (VOCs), and with ozone. All tests were performed at realistic pollutant levels in a 20-m 3 environmental stainless-steel chamber. Variables controlled and measured in this study included the chamber temperature, relative humidity, the composition and concentration of the challenge VOCs, and the concentrations of ozone. Potential formation of byproducts was also investigated to assess the overall performance.

47 OTHER INSTRUMENTATION↗

MCNP modelling of the Thermo SPA3 with Tungsten (Rees model) collimator

A Thermo Model SPA3 2”x2” NaI probe fitted with a Tungsten collimator has been modelled using MCNP6. The collimator was assumed to be machinable Tungsten which typically includes Ni and Fe. Various ratios of these additives are used in industry and for the purposes of these calculations the collimator was assumed to contain 7% Ni and 3% Fe with a density of 17.0 g/cm 3 . The dimensions of the collimator were based on measurements taken by Mike Fanning. The above detector model was used, in a manner similar to the approach described in LA-UR-19-32358, to calculate photopeak count rates per unit activity per unit area (i.e. cpm per pCi/cm 2 ) conversion factors for various contamination scenarios.

61 RADIATION PROTECTION AND DOSIMETRY↗

HEX 2-piece ID Absorber: Steady and Transient Thermal FEA

Radiation fans from Insertion Devices and Bending Magnets are “trimmed” by various water-cooled absorbers located strategically downstream of those sources. Mostly, the absorber surfaces onto which power is deposited are constructed from Glidcop Al-15 (rarely OFHC copper). On the basis of Tech Note 327 a re-design for improved thermal performance has evolved to a two-piece ID Absorber configuration; one between dipole chamber and quadrupole, another after the sextupole, each with reduced incident angle. The ring’s Active Interlock (AI) system protects against overheating by disabling mis-steered beam within an allotted time. SRP (Synchrotron Radiation Protection) protocol has a limiting maximum allowable temperature of 100*C at any point when subject to mis-steered beam for a fixed period before AI activation. After 0.2 msec, radiation exceeding +/- 0.5mm offset and +/- 0.25 mrad angular error from the HEX SCW will trip in fault. AI specification allows 1.0 msec to fully dump the electron beam.

36 MATERIALS SCIENCE↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving AHU Performance by Minimizing Approach Temperature, Reducing Air Maldistribution, and Efficiently Handling Sensible and Latent Loads (Phase 1 Interim Final Technical Report)

Residential air handling units (AHUs) have stayed the same in form and efficiency for the past 30+ years, with incremental improvements made to address safety, functionality, and energy-efficiency. The purpose of this research in Phase I, Topic 9a: Next Generation Residential Air Handlers, was to improve AHU performance by minimizing heat exchanger (HX) approach temperature, reducing air maldistribution, and developing alternative system configurations which more efficiently handle sensible and latent loads. In this research Optimized Thermal Systems (OTS) developed, modeled, and evaluated multiple alternative system concepts. A dual vapor compression system separate sensible and latent cooling (SSLC) concept was studied to inform work on alternative concepts and to show best-case performance benefit. System concepts included ejector enhanced vapor compression cycles, desiccant assisted dehumidification, dual evaporator SSLC, and alternative AHU HX configurations. A dual vapor compression system showed COP improvement of 20%, however, required additional components, increased unit size, and increased cost. Two types of ejector enhanced vapor compression cycles with dual evaporators improved system COP by 9 to 11%, and reduced AHU losses by as much as 18%, with design changes limited to the AHU, no unit physical size increase, and a moderate increase to system first cost. Desiccant assisted air-conditioning required increased air flow rate resulting in higher fan power and the desiccant wheel increased sensible heat load leading to increased compressor power and reduced system COP. Dual evaporator cycles were found to degrade performance due to increased expansion losses. Optimized single slab HX designs used in place of the traditional A-coil HX led to 44–49% reduction in aluminum, 47–60% less refrigerant charge, and improved HX velocity distribution.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empowering Energy Efficiency in Existing Big-Box Retail/Grocery Stores (Final Optimization Report)

The Center for Sustainable Energy (CSE), in partnership with the National Renewable Energy Laboratory (NREL), TRC Energy Services, P2S Engineering Inc, Walmart, and five innovative technology providers, are to demonstrate the impact of an integrated suite of pre-commercial energy efficiency (EE) technologies in a large, existing, retail building located within an inland disadvantaged community. Proposed technology packages include three categories of advanced EE solutions: heating, ventilating, air-conditioning, and refrigerating (HVAC/R); lighting; and integrated system and building level controls. The project is designed to impact Walmart’s future store specifications, which can be replicated and deployed in other buildings across California with similar end-use and system characteristics. The following lists the technologies considered for this project: DualCool (HVAC evaporative cooling); Software Motor Company (SMC) (HVAC and refrigeration fan motor); I2S: DC LED lighting; LocBit: building energy management and optimization; Saya: water monitoring.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Agricultural Impacts on Nitrogen Cycling: Climate and Air Pollution (Final Technical Report)

We have successfully added a parameterization of ammonia emissions from synthetic fertilizer and manure from agriculture to Earth System Models. We have evaluated how emissions change in the future and the processes driving these changes. We have examined the impact of agricultural ammonia emissions on present-day air quality and have evaluated the impact of resolving the emissions with high temporal resolution. We have also examined the impact of how Earth System Models treat the cycling of emissions in soils. Our code, the Flows of Agricultural Nitrogen – version 2 – model (FANv2) has been run in both the CLM framework and the ELM framework. To my knowledge the code has not yet been fully implemented into ELM. Volatilization of ammonia (NH3) from fertilizers and livestock wastes forms a significant pathway of nitrogen losses in agricultural ecosystems and constitutes the largest source of atmospheric emissions of NH3. We have provided a major update to the process model FAN (Flow of Agricultural Nitrogen), which evaluates NH3 emissions interactively within an Earth system model; in this work, the Community Earth System Model (CESM) is used. The updated version (FANv2) includes a more detailed treatment of both physical and agricultural processes, which allows the model to differentiate between the volatilization losses from animal housings, manure storage, grazed pastures, and the application of manure and different types of mineral fertilizers. The modeled ammonia emissions are first evaluated at a local scale against experimental data for various types of fertilizers and manure, and they are subsequently run globally to evaluate NH3 emissions for 2010–2015 based on gridded datasets of fertilizer use and livestock populations. Comparison of regional emissions shows that FANv2 agrees with previous inventories for North America and Europe and is within the range of previous inventories for China. However, due to higher NH3 emissions in Africa, India, and Latin America, the global emissions simulated by FANv2(48 Tg N) are 30 %–40 % higher than in the existing inventories.

54 ENVIRONMENTAL SCIENCES↗

Hotel Room Computational Fluid Dynamics to Investigate Airborne Pathogen Dispersal Patterns

A hotel room unit consisting of a bedroom and bathroom was modelled using computational fluid dynamics (CFD) to investigate airborne pathogen dispersal patterns. The full-scale model includes a ‘typical’ hotel room configuration, furniture, and vents. The air sources and sinks include a bathroom vent, a heating, ventilation, and cooling (HVAC) unit located in the bedroom, and a ½” gap at the bottom of the entry door. In addition, the entry door and window can be opened or closed, as desired. Three key configuration simulations were conducted: 1) both the bathroom vent and HVAC were on, 2) only the HVAC was on, and 3) only the bathroom vent was on. If the HVAC air is from a fresh, clean source, or passes through a high-efficiency filter/UV device, then the first configuration is the safest, as contaminated air is highly reduced. The second configuration is also safe, but does not benefit from the outsourcing of potentially-infected air, such as contaminated air flowing through an ineffective filter. The third configuration should be avoided, as the bathroom vent causes air to flow from the hallway, which can be of dubious origin. The CFD simulations also showed that recirculation and swirling regions tend to accumulate the largest concentrations of heavier airborne particles, pathogens, dust, etc. These regions are associated with the largest turbulence kinetic energy (TKE) , and tend to occur in areas with flow recirculation and corners. Therefore, TKE presents a reasonable metric to guide the strategic location of pathogen mitigation devices. The simulations show complex flow patterns with distinct upper and lower flow regions, swirling flow, and significant levels of turbulent mixing. These simulations provide intriguing insights that can be applied to help mitigate pathogen aerosol dispersal, generate building design guidelines, as well as provide insights for the strategic placement of mitigation devices, such as ultraviolet (UV) light, supplemental fans, and filters.

54 ENVIRONMENTAL SCIENCES↗

Cooling Performance Testing of Attaway's Negative Pressure CDU

Attaway is a recently installed High-Performance Computing (HPC) machine at Sandia National Labs that is 70% water-cooled and 30% air-cooled. This machine, supplied by Penguin Computing, uses a novel new cooling system from Chilldyne that operates in a vacuum, preventing water leaks. If water-cooling is to fail, fans inside of each node will ramp up to do 100% of the cooling on Attaway. Various tests were completed on Attaway to determine the robustness of its cooling system as well as its ability to respond to sudden changes in states. These changes include an immediate change from an idle compute load to full load (Linpack) as well as running Linpack without any water cooling from Attaway's CDUs. It was discovered that Attaway could respond to sudden compute load changes very well, never throttling any nodes. When Linpack was run without water cooling, the system was able to operate for a short time before throttling happened.

42 ENGINEERING↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space conditioning loads.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Listen: Oppenheimer’s office chair one of the only possessions the lab has from our first director

Even the father of the atomic bomb had to sit down somewhere. It's hard to believe that our legendary first Lab director and brilliant physicist J. Robert Oppenheimer did something as ordinary as using a chair at work like the rest of us do. However, aside from a recently gifted book, this chair from the 1940s is the only Oppenheimer possession that the Lab has. And Oppie fans love it. The chair is routinely loaned to museums nationwide for display.

99 GENERAL AND MISCELLANEOUS↗

Smart Labs Final Report Summer 2021

The Smart Labs Project at Los Alamos National Laboratory (LANL) is an initiative derived from The University of California, Irvine and is part of the Department of Energy’s (DOE) Better Buildings Challenge. These carbon abatement strategies aim to reduce energy consumption of laboratories while also maintaining health and safety requirements. Smart Labs designs incorporate seven key principles which are: digital control systems, demand-based ventilation, low power-density demand-based lighting, exhaust fan discharge velocity optimization, pressure drop optimization, fume hood flow optimization, and commissioning with automated cross-platform fault detection. As the ALDCP Smart Labs team for the summer of 2021, the scope of the project is to determine the energy savings within building 03-1698 (Material Science Laboratory - MSL). Over the past couple of years, the Sustainability Group has been adding Smart Labs upgrades into the MSL building and the summer team would like to understand the impact made for the overall energy consumption/demand and safety for the building, determine the overall return on investment (ROI), and recommend more Smart Labs upgrades that can be added to the MSL building. The goal is to enable the UI FOD (Utilities and Infrastructure Facility Operation Division) to promote more Smart Labs projects in the future and further the reputation LANL and DOE facilities have of being leading examples of developers of high performing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Model-based Design Optimization to Achieve the Performance Goals (16.0 SEER/9.5 HSPF), Developing Heat Pump by Using Low-GWP Refrigerants and 5 mm Diameter Tubes

Usage of low-GWP refrigerants can reduce the Green House Gas (GHG) emission of HVAC systems. Our research in previous milestone report has shown that using heat exchangers with 5 mm diameter tubes instead of 9 mm diameter tubes is a promising solution to meet the performance goals of heat pump using low-GWP refrigerants. In addition, the 5mm tube heat exchangers can lead to lower system refrigerant charge and as a result, reduce environmental impact further. However, shifting to small tube diameters requires in-depth heat exchanger design optimization to adapt to the transition to low-GWP refrigerants. In the 2nd quarter of FY21, we conducted multi-objective optimizations using Particle Swarm Optimization algorithm on a residential 5-ton air source heat pump to investigate the potential system performance improvements and material savings. 4 low-GWP refrigerants, ARM20A, ARM20B, R454A and R454C are investigated in this study. The objectives of the optimization are to minimize the heat pump material cost and to maximize the system performance simultaneously. As a result, the HXs material cost is reduced by up to 77% according to the copper and aluminum material price in current market. Under heating mode operation, the smart 4-way valve guarantees that the optimal low-GWP systems maintain or outperform the heating performance of the R410A baseline system. The model-based design optimization yields 18.3-18.9 SEER and 10.6-11.9 HSPF for optimal systems using different low-GWP refrigerants. The initial performance goals (16.0 SEER/9.5 HSPF) are achieved. Furthermore, up to 50% system refrigerant charge reduction is possible in the optimized low-GWP heat pump system using ARM20B. And 91%-95% predicted life-time direct CO 2 emission reduction is achieved by using the optimal 5mm tube low-GWP heat pumps. The significant material saving, charge reduction and direct CO 2 emission reduction help in reducing the environmental impacts of heat pump systems. The optimal heat exchangers resulting from this research can fit into the original baseline indoor and outdoor fan-coil unit. This can reduce the retrofitting effort by minimizing the change in manufacturing and installation of the heat pumps and guarantee the compatibility with end-users’ house structure. Finally, the new products can be easily accepted by manufacturers and end-users.

42 ENGINEERING↗