Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast diffraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Laboratory Instruments Available to Support Space Station Researchers at Marshall Space Flight Center

A number of research instruments are available at NASA's Marshall Space Flight Center (MSFC) to support ISS researchers and their investigations. These modern analytical tools yield valuable and sometimes new informative resulting from sample characterization. Instruments include modern scanning electron microscopes equipped with field emission guns providing analytical capabilities that include angstron-level image resolution of dry, wet and biological samples. These microscopes are also equipped with silicon drift X-ray detectors (SDD) for fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations in crystalline alloys. Sample chambers admit large samples, provide variable pressures for wet samples, and quantitative analysis software to determine phase relations. Advances in solid-state electronics have also facilitated improvements for surface chemical analysis that are successfully employed to analyze metallic materials and alloys, ceramics, slags, and organic polymers. Another analytical capability at MSFC is a mganetic sector Secondary Ion Mass Spectroscopy (SIMS) that quantitatively determines and maps light elements such as hydrogen, lithium, and boron along with their isotopes, identifies and quantifies very low level impurities even at parts per billion (ppb) levels. Still other methods available at MSFC include X-ray photo-electron spectroscopy (XPS) that can determine oxidation states of elements as well as identify polymers and measure film thicknesses on coated materials, Scanning Auger electron spectroscopy (SAM) which combines surface sensitivity, spatial lateral resolution (approximately 20 nm), and depth profiling capabilities to describe elemental compositions in near surface regions and even the chemical state of analyzed atoms. Conventional Transmission Electron Microscope (TEM) for observing internal microstructures at very high magnifications and the Electron Probe Micro-analyzer (EPMA) for very precise microanalysis are available as needed by the researcher. Space Station researchers are invited to work with MSFC in analyzing their samples using these techniques.

Panda, Binayak↗

Shielding design for a chip irradiation test facility at SNS - Paper 119

As digital and analog circuits are more and more sophisticatedly integrated, they become increasingly susceptible to single event upsets (SEU), a cause of electronic equipment malfunction induced by cosmic rays with particular hazard potential for aviation equipment. Electronic chips sensitive to SEU have to be tested in a simulated comic ray environment to ensure their reliability. It is found that the spallation induced fast neutron spectrum is very close to the neutron spectrum of the cosmic ray. Hence, a conceptual design study of a chip irradiation test facility is funded by FAA to be carried out at SNS, the world's most powerful accelerator driven facility for neutron scattering studies on materials. Compared to existing/being construct chip irradiation test facilities at LANL and ISIS, SNS can provide wider neutron energy range and much higher fluxes. This study focuses on the aspect of shielding design for such a chip irradiation facility. A number of medium-weighted and heavy materials were examined for efficiency in reducing radiation dose rate. In general, the smaller the target monolith is while satisfying the personnel-protection-driven radiation dose rate limit at its outside, the closer to the target chips could be placed and thus less beam power it demands to satisfy a given irradiation flux requirement. Before proceed to the shielding design, the neutron source coming off the target has to be determined for selecting a best spot for chip irradiation test, in which the incoming fast neutron spectrum approximate most to the atmospheric radiation condition. It also provides a source term for the following shielding design of the irradiation enclosure. (authors)

36 MATERIALS SCIENCE↗

Structural state of a radiation-modified Ti{sub 50}Ni{sub 47}Fe{sub 3} single crystal

The structural state of a Ti{sub 50}Ni{sub 47}Fe{sub 3} single crystal irradiated by fast neutrons (F = 2.5 Multiplication-Sign 10{sup 20} cm{sup -2}) at 340 K was studied by thermal neutron diffraction at 78 and 295 K. The melt of this composition was chosen with the purpose of designing a radiation-resistant material exhibiting a shape-memory effect. It was found that the melt remains crystalline after irradiation, whereas the Ti{sub 49}Ni{sub 51} crystal studied earlier becomes amorphous after an analogous irradiation. In spite of the fact that the main structural motif of the crystal remains unchanged after irradiation, martensitic transformations in the crystal do not occur and, consequently, the shape-memory effect is not retained. The radiation resistance of this class of crystals was estimated.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Time-of-Flight Chromatic Aberration on the Dynamics of Propagation of Pulsed Electron Beam in Ultrafast Electron Microscopy: A New Strategy for Better Temporal Resolution

A common strategy aimed at achieving a high temporal resolution in ultrafast electron microscopy and diffraction is based on the use of strong electrostatic fields in the accelerating gap to form fast electron pulses of ultrashort duration. In this work, the dynamics of the propagation of ultrashort photoelectron bunches is studied taking into account the time-of-flight chromatic aberration: the spread-out of electron pulses at the exit from the region of the accelerating electric field. The results of the calculation of the duration of photoelectron pulses taking into account Coulomb repulsion are presented. According to the analysis, the use of strong electrostatic fields in the accelerating gap for the formation of fast electron pulses of ultrashort duration is not a necessary condition for achieving the final high temporal resolution in the method of ultrafast electron microscopy. The modes of operation of ultrafast transmission electron microscope were found for which the temporal resolution increases with the growth of time-of-flight chromatic aberration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of solvent formulations in electrolytes on fast charging of Li-ion cells

Improving the fast charging performance of lithium ion batteries (LIBs) has the promise to increase the widespread adoption of electric vehicles (EVs). Electrolyte development plays an important role in enabling fast charging. In this study, fast charging performance of LIBs is studied with different electrolytes of 1.2 M LiPF 6 in Ethylene Carbonate (EC)/Ethyl Methyl Carbonate (EMC)/co-solvents at 30/50/20 wt%. The co-solvents are methyl acetate (MA), ethyl acetate (EA), ethyl formate (EF), dimethyl carbonate (DMC) and EMC. Long term cycling performance under fast charging shows different capacity retention behaviors for different co-solvents. The structural changes in the electrode material are studied by X-ray absorption spectroscopy (XAS) and X-ray diffraction (XRD). The molarity changes in electrolyte is investigated by inductively coupled plasma-optical emission spectroscopy (ICP-OES). The electrode/electrolyte interfaces before and after fast charging are analyzed by X-ray photoemission spectroscopy (XPS). The characterization results are in good agreement with the long-term cycling performance. DMC shows the highest fast-charging capability among the five studied co-solvents due to its increased conductivity, improved electrode/electrolyte interface and stable electrode structural integrity.

25 ENERGY STORAGE↗

Mechanisms in Knockout Reactions

We report the first detailed study of the relative importance of the stripping and diffraction mechanisms involved in nucleon knockout reactions, by the use of a coincidence measurement of the residue and fast proton following one-proton knockout reactions. The measurements used the S800 spectrograph in combination with the HiRA detector array at the NSCL. Results for the reactions {sup 9}Be({sup 9}C,{sup 8}B+X)Y and {sup 9}Be({sup 8}B,{sup 7}Be+X)Y are presented and compared with theoretical predictions for the two reaction mechanisms calculated using the eikonal model. The data show a clear distinction between the stripping and diffraction mechanisms and the measured relative proportions are very well reproduced by the reaction theory. This agreement adds support to the results of knockout reaction analyses and their applications to the spectroscopy of rare isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast attenuation of high-frequency acoustic waves in bicontinuous nanoporous gold

We studied the formation and attenuation of GHz elastic waves in free-standing nanoporous gold films by MeV ultrafast electron diffraction and finite element simulations. By tracing the evolution of the high frequency acoustic waves in time domain, we found that the bicontinuous nanoporous structure in nanoporous gold films results in three-dimensionally acoustic response with low coherence, leading to fast attenuation of the elastic waves in comparison with solid gold films. The morphologically dominated dynamics indicates the nanoporosity plays an important role in the high-frequency acoustic energy relaxation, which shines a light on the applications of dealloyed nanoporous materials in nanodevices and sensors as GHz and THz acoustic filters and dampers.

36 MATERIALS SCIENCE↗

Correlation Fourier diffractometry: 20 Years of experience at the IBR-2 reactor

The high-resolution Fourier diffractometer (HRFD) was commissioned at the IBR-2 pulsed reactor at FLNP JINR in 1994. The specific feature of the HRFD design is the use of fast Fourier chopper for modulating the primary neutron beam intensity and the correlation method of diffraction data acquisition. This allowed to reach with HRFD extremely high resolution (Δ d / d ≈ 0.001) over a wide range of inter-planar spacings at a relatively short flight path between chopper and sample (L = 20 m). Over time, a lot of diffraction experiments on crystalline materials, the main goal of which was to study their atomic and magnetic structures, were performed at HRFD. Successful implementation of the Fourier diffractometry technique at the IBR-2 reactor stimulated the construction of yet another Fourier diffractometer intended for internal mechanical stress studies in bulk materials (FSD, Fourier Stress Diffractometer). In this paper the experience of using this technique at the IBR-2, which is a long-pulse neutron source, is considered, the examples of HRFD studies are given, and possible solutions for existing technical problems of using correlation diffractometry and ways of increasing the intensity and resolution of HRFD are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Direct and real time probe of photoinduced structure transition in colossal magnetoresistive material

Here, we report a direct and real time measurement of photoinduced structure phase transition in single crystal La 0.84 Sr 0.16 MnO 3 using femtosecond electron diffraction. The melting of orthorhombic lattice ordering under femtosecond optical excitation is found involving two distinct processes with different time scales, an initial fast melting of orthorhombic phase in about 4 ps and a subsequent slower transformation in 90 ps and longer timescales. Furthermore, the fast process is designated as the initial melting of orthorhombic phase induced by the Mn-O bond change that is most likely driven by the quenching of the dynamic Jahn-Teller distortion following the photo-excitation. We attribute the slow process to the growing of newly formed structure domain from the photo-excited sites to the neighboring non-excited orthorhombic sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Faster Processing for Inverting GPS Occultation Data

A document outlines a computational method that can be incorporated into two prior methods used to invert Global Positioning System (GPS) occultation data [signal data acquired by a low-Earth-orbiting satellite as either this or the GPS satellite rises above or falls below the horizon] to obtain information on altitude-dependent properties of the atmosphere. The two prior inversion methods, known as back propagation and canonical transform, are computationally expensive because for each occultation, they involve numerical evaluation of a large number of diffraction-like spatial integrals. The present method involves an angular-spectrum-based phase-extrapolation approximation in which each data point is associated with a plane-wave component that propagates in a unique direction from the orbit of the receiving satellite to intersect a straight line tangent to the orbit at a nearby point. This approximation enables the use of fast Fourier transforms (FFTs), which apply only to data collected along a straight-line trajectory. The computation of the diffraction-like integrals in the angular-spectrum domain by use of FFTs takes only seconds, whereas previously, it took minutes.

Ao, Chi↗

Analysis of Al diffusion processes in TiN barrier layers for the application in silicon solar cell metallization

An evaporated Al layer is known as an excellent rear metallization for highly efficient solar cells, but suffers from incompatibility with a common solder process. To enable solar cell-interconnection and module integration, in this work the Al layer is complemented with a solder stack of TiN/Ti/Ag or TiN/NiV/Ag, in which the TiN layer acts as an Al diffusion barrier. X-ray photoelectron spectroscopy measurements prove that diffusion of Al through the stack and the formation of an Al{sub 2}O{sub 3} layer on the stack's surface are responsible for a loss of solderability after a strong post-metallization anneal, which is often mandatory to improve contact resistance and passivation quality. An optimization of the reactive TiN sputter process results in a densification of the TiN layer, which improves its barrier quality against Al diffusion. However, measurements with X-ray diffraction and scanning electron microscopy show that small grains with vertical grain boundaries persist, which still offer fast diffusion paths. Therefore, the concept of stuffing is introduced. By incorporating oxygen into the grain boundaries of the sputtered TiN layer, Al diffusion is strongly reduced as confirmed by secondary ion mass spectroscopy profiles. A quantitative analysis reveals a one order of magnitude lower Al diffusion coefficient for stuffed TiN layers. This metallization system maintains its solderability even after strong post-metallization annealing at 425 °C for 15 min. This paper thus presents an industrially feasible, conventionally solderable, and long-term stable metallization scheme for highly efficient silicon solar cells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microstructural characterization and assessment of mechanical properties of concrete based on combined elemental analysis techniques and Fast-Fourier transform-based simulations

This paper presents a pixel-based modeling approach of concrete which combines an experimental characterization of concrete and the Fast-Fourier transform simulations. High-resolution phase maps created from experimental characterization by micro X-ray fluorescence, energy dispersive X-ray analysis, and X-ray diffraction contain 9 different phases, including 22.17 vol.% of hydrated cement paste, 54.21 vol.% of minerals, and 23.62 vol.% of interfaces. These phases provide the input for determining the effective elastic properties, coupled with Fast-Fourier transform-based simulation. The simulation results show that the effective range of Young’s modulus of concrete is comparable with the range of experimental values ~ 37 ± 4 GPa with the assumption of realistic properties of interfaces.

36 MATERIALS SCIENCE↗

Beamline I11 at Diamond: A new instrument for high resolution powder diffraction

The performance characteristics of a new synchrotron x-ray powder diffraction beamline (I11) at the Diamond Light Source are presented. Using an in-vacuum undulator for photon production and deploying simple x-ray optics centered around a double-crystal monochromator and a pair of harmonic rejection mirrors, a high brightness and low bandpass x-ray beam is delivered at the sample. To provide fast data collection, 45 Si(111) analyzing crystals and detectors are installed onto a large and high precision diffractometer. High resolution powder diffraction data from standard reference materials of Si, {alpha}-quartz, and LaB{sub 6} are used to characterize instrumental performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and Tuning of Hematite (α-Fe{sub 2}O{sub 3}) Iron Oxide Nanorods with Magnetism

In recent years, hematite (α-Fe{sub 2}O{sub 3}) iron oxide nanorods have attracted the attention of many researchers due to their wide applications in nanobiosensors, lithium batteries and nanomagnetism. In the present work, hematite nanorods with magnetic and optical properties were synthesized in desirable qualities via a fast and low-cost method. Features of these nanorods were determined using X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM), ultraviolet–visible (UV–vis) spectroscopy and vibrating sample magnetometry (VSM). Uniform nanorods with a length of between 20 and 30 nm were fabricated in a 0.05:1:3.4 molar ratio of cetyltrimethylammonium bromide (CTAB)/FeCl{sub 3}/NaOH. The VSM technique showed that the presence of the CTAB as a surfactant agent in 0.1, 0.05 and 0.025 mol L{sup − 1} concentrations can reduce the magnetization of nanorods with an increase in surface layers. The optical absorbance properties of the hematite nanorods demonstrated that the absorption peaks are well tuned in wavelengths of about 250 and 400 nm. The hematite nanorods with the tuned structure in terms of magnetic and optical properties can be proposed as a desirable option in future applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Myosin-binding protein C regulates the sarcomere lattice and stabilizes the OFF states of myosin heads

Muscle contraction is produced via the interaction of myofilaments and is regulated so that muscle performance matches demand. Myosin-binding protein C (MyBP-C) is a long and flexible protein that is tightly bound to the thick filament at its C-terminal end (MyBP-C C8C10 ), but may be loosely bound at its middle- and N-terminal end (MyBP-C C1C7 ) to myosin heads and/or the thin filament. MyBP-C is thought to control muscle contraction via the regulation of myosin motors, as mutations lead to debilitating disease. We use a combination of mechanics and small-angle X-ray diffraction to study the immediate and selective removal of the MyBP-C C1C7 domains of fast MyBP-C in permeabilized skeletal muscle. We show that cleavage leads to alterations in crossbridge kinetics and passive structural signatures of myofilaments that are indicative of a shift of myosin heads towards the ON state, highlighting the importance of MyBP-C C1C7 to myofilament force production and regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Deposition and composition-control of Mn-doped ZnO thin films by combinatorial pulsed laser deposition using two delayed plasma plumes

Thin films of ZnO doped with manganese were deposited by double-beam, combinatorial pulsed laser deposition. The laser-induced plasmas were studied by means of fast photography and using a Langmuir probe, whereas the films were analyzed by x-ray-diffraction and energy-dispersive x-ray spectroscopy. The effect of the relative delay between plasma plumes on the characteristics of the films was analyzed. It was found that using this parameter, it is possible to control the dopant content keeping the oriented wurtzite structure of the films. The minimum content of Mn was found for plume delays between 0 and 10 {mu}s as the interaction between plasmas scatters the dopant species away from the substrate, thus reducing the incorporation of Mn into the films. Results suggest that for delays shorter than {approx}100 {mu}s, the expansion of the second plume through the region behind the first plume affects the composition of the film.

36 MATERIALS SCIENCE↗

Fast x-ray microdiffraction techniques for studying irreversible transformations in materials.

A pair of techniques have been developed for performing time-resolved X-ray microdiffraction on irreversible phase transformations. In one technique capillary optics are used to focus a high-flux broad-spectrum X-ray beam to a 60 {micro}m spot size and a fast pixel array detector is used to achieve temporal resolution of 55 {micro}s. In the second technique the X-rays are focused with Kirkpatrick-Baez mirrors to achieve a spatial resolution better than 10 {micro}m and a fast shutter is used to provide temporal resolution better than 20 {micro}s while recording the diffraction pattern on a (relatively slow) X-ray CCD camera. Example data from experiments are presented where these techniques are used to study self-propagating high-temperature synthesis reactions in metal laminate foils.

43 PARTICLE ACCELERATORS↗