Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

SRF CAVITY FAULT PREDICTION USING DEEP LEARNING AT JEFFERSON LAB

In this study, we present a deep learning-based pipeline for predicting superconducting radio-frequency (SRF) cavity faults in the Continuous Electron Beam Accelera-tor Facility (CEBAF) at Jefferson Lab. We leverage pre-fault RF signals from C100-type cavities and employ deep learning to predict faults in advance of their onset. We train a binary classifier model to distinguish between stable and impending fault signals. Test results show accuracies exceeding 99% for distinguishing between normal signals and pre-fault signals from a class of more slowly developing fault types, such as microphonics. We describe results from a proof-of-principle demonstration on a realistic, imbalanced data set and report performance metrics. Encouraging results suggest that future SRF systems could leverage this framework and implement measures to mitigate the onset in more slowly developing fault types.

Rahman, M.↗

Seismic Elastic Double-Beam Characterization of Faults and Fractures for CO₂ Storage Site Selection

Site characterization for underground injection and storage of gigatonne-scale CO₂ requires reliable and cost-effective methods to detect and characterize faults and fractures and to assess their stress state and fault activation potential. This is critical, as wastewater injection and disposal have been shown to activate faults and induce earthquakes, and CO₂ leakage remains a key concern for long-term storage. In this project, we developed seismic methods to detect and characterize large-scale sedimentary and crystalline basement faults and associated small-scale fractures below conventional seismic imaging resolution using multicomponent (9C) surface seismic data. Machine learning was used to automatically interpret large-scale faults, providing key information for estimating the maximum magnitude of potential induced earthquakes. High-fidelity imaging was achieved by exploiting redundancy across multiple elastic wave modes, where independent images from different modes and frequencies cross-validate each other. We also used our nonlinear signal comparison (NLSC) method for ground roll removal, improving data quality in complex near-surface conditions. The methods were validated using field data acquired in central Montana. Results show that basement faults extend into the sedimentary section and that small-scale fractures are widespread above the basement. The inferred stress orientation is consistent with regional stress data, and the estimated maximum induced earthquake magnitude is small (Mw ~2.3). The developed workflow provides a practical approach for fault and fracture characterization and for assessing induced seismicity and leakage risk. It is directly applicable to CO₂ storage site selection and to other subsurface systems.

02 PETROLEUM↗

Experimental Investigation of Steel-Borne Acoustic Pulses for Fault Pinpointing in Pipe-Type Cable Systems: A Scaled-Down Model Approach

Pipe-type cable systems, including high-pressure fluid-filled (HPFF) and high-pressure gas-filled cables, are widely used for underground high-voltage transmission. These systems consist of insulated conductor cables within steel pipes, filled with pressurized fluids or gases for insulation and cooling. Despite their reliability, faults can occur due to insulation degradation, thermal expansion, and environmental factors. As many circuits exceed their 40-year design life, efficient fault localization becomes crucial. Fault location involves prelocation and pinpointing. Therefore, a novel pinpointing approach for pipe-type cable systems is proposed, utilizing accelerometers mounted on a steel pipe to capture fault-induced acoustic signals and employing the time difference of arrival method to accurately pinpoint the location of the fault. The experimental investigations utilized a scaled-down HPFF pipe-type cable system setup, featuring a carbon steel pipe, high-frequency accelerometers, and both mechanical and capacitive discharge methods for generating acoustic pulses. The tests evaluated the propagation velocity, attenuation, and pinpointing accuracy with the pipe in various embedment conditions. The experimental results demonstrated accurate fault pinpointing in the centimeter range, even when the pipe was fully embedded, with the acoustic pulse velocities aligning closely with the theoretical values. These experimental investigation findings highlight the potential of this novel acoustic pinpointing technique to improve fault localization in underground systems, enhance grid reliability, and reduce outage duration. Further research is recommended to validate this approach in full-scale systems.

Moutassem, Zaki↗

The application of Skylab imagery to analysis of fault tectonics and earthquake hazards in the Peninsular Ranges, southern California

The author has identified the following significant results. Frame 114 of the Salton Sea area was studied in all bands to analyze the appearance of important faults. These faults were also studied in the field as well as from aircraft and in aerial photography. The San Andreas/Banning and the Mission Creek faults can be traced across Coachella Valley even though they are buried by alluvium. The faults form ground water barriers and the near surface ground water on the northeast sides of the faults supports patches of vegetation (mesquite and palms) in an otherwise barren desert. These oases are best seen in band 3 (color IR). Otherwise, faults are best seen in band 4 (aerial color). Of the B and W bands, 5 (red) is best for delineating faults. Bands 1 and 2 are excessively grainy and the resolution is considerably inferior to the other bands.

Merifield, P. M.↗

On-line diagnosis of unrestricted faults

A formal model for the study of on-line diagnosis is introduced and used to investigate the diagnosis of unrestricted faults. A fault of a system S is considered to be a transformation of S into another system S' at some time tau. The resulting faulty system is taken to be the system which looks like S up to time tau, and like S' thereafter. Notions of fault tolerance error are defined in terms of the resulting system being able to mimic some desired behavior as specified by a system similar to S. A notion of on-line diagnosis is formulated which involves an external detector and a maximum time delay within which every error caused by a fault in a prescribed set must be detected. It is shown that if a system is on-line diagnosable for the unrestricted set of faults then the detector is at least as complex, in terms of state set size, as the specification. The use of inverse systems for the diagnosis of unrestricted faults is considered. A partial characterization of those inverses which can be used for unrestricted fault diagnosis is obtained.

Meyer, J. F.↗

Fault tectonics and earthquake hazards in the Peninsular Ranges, Southern California

The author has identified the following significant results. ERTS and Skylab images reveal a number of prominent lineaments in the basement terrane of the Peninsular Ranges, Southern California. The major, well-known, active, northwest trending, right-slip faults are well displayed, but northeast and west to west-northwest trending lineaments are also present. Study of large-scale airphotos followed by field investigations have shown that several of these lineaments represent previously unmapped faults. Pitches of striations on shear surfaces of the northeast and west trending faults indicate oblique-slip movement; data are insufficient to determine the net-slip. These faults are restricted to the pre-Tertiary basement terrane and are truncated by the major northwest trending faults; therefore, they may have formed in response to an earlier stress system. Future work should be directed toward determining whether the northeast and west trending faults are related to the presently active stress system or to an older inactive system, because this question relates to the earthquake risk in the vicinity of these faults.

Merifield, P. M.↗

A renormalization group model for the stick-slip behavior of faults

A fault which is treated as an array of asperities with a prescribed statistical distribution of strengths is described. For a linear array the stress is transferred to a single adjacent asperity and for a two dimensional array to three ajacent asperities. It is shown that the solutions bifurcate at a critical applied stress. At stresses less than the critical stress virtually no asperities fail on a large scale and the fault is locked. At the critical stress the solution bifurcates and asperity failure cascades away from the nucleus of failure. It is found that the stick slip behavior of most faults can be attributed to the distribution of asperities on the fault. The observation of stick slip behavior on faults rather than stable sliding, why the observed level of seismicity on a locked fault is very small, and why the stress on a fault is less than that predicted by a standard value of the coefficient of friction are outlined.

Smalley, R. F., Jr.↗

Fault friction, regional stress, and crust-mantle coupling in southern California from finite element models

To determine the correct fault rheology of the Transverse Ranges area of California, a new finite element to represent faults and a mangle drag element are introduced into a set of 63 simulation models of anelastic crustal strain. It is shown that a slip rate weakening rheology for faults is not valid in California. Assuming that mantle drag effects on the crust's base are minimal, the optimal coefficient of friction in the seismogenic portion of the fault zones is 0.4-0.6 (less than Byerly's law assumed to apply elsewhere). Depending on how the southern California upper mantle seismic velocity anomaly is interpreted, model results are improved or degraded. It is found that the location of the mantle plate boundary is the most important secondary parameter, and that the best model is either a low-stress model (fault friction = 0.3) or a high-stress model (fault friction = 0.85), each of which has strong mantel drag. It is concluded that at least the fastest moving faults in southern California have a low friction coefficient (approximtely 0.3) because they contain low strength hydrated clay gouges throughout the low-temperature seismogenic zone.

Bird, P.↗

Development and evaluation of a Fault-Tolerant Multiprocessor (FTMP) computer. Volume 3: FTMP test and evaluation

The experimental test and evaluation of the Fault-Tolerant Multiprocessor (FTMP) is described. Major objectives of this exercise include expanding validation envelope, building confidence in the system, revealing any weaknesses in the architectural concepts and in their execution in hardware and software, and in general, stressing the hardware and software. To this end, pin-level faults were injected into one LRU of the FTMP and the FTMP response was measured in terms of fault detection, isolation, and recovery times. A total of 21,055 stuck-at-0, stuck-at-1 and invert-signal faults were injected in the CPU, memory, bus interface circuits, Bus Guardian Units, and voters and error latches. Of these, 17,418 were detected. At least 80 percent of undetected faults are estimated to be on unused pins. The multiprocessor identified all detected faults correctly and recovered successfully in each case. Total recovery time for all faults averaged a little over one second. This can be reduced to half a second by including appropriate self-tests.

Lala, J. H.↗

New results in fault latency modelling

The test design and results from assessment of the performance of the self-test program and the extent of fault latency in a redundant flight control system (FCS) are reported. Assembly language programming generated gate-level faults directed to every avionics component. Details of the fault-simulation software are described, noting the input needed to match the five control-surface parameters managed by the FCS. Most faults were immediately detected, and component-level faults, occurring at pins, were more easily noted than gate-level faults. The results indicated that a 200-word self-test program is sufficient to obtain a fault coverage of 85 percent. Minor hardware changes are required to reach levels over 90 percent.

Mcgough, J. G.↗

A renormalization group approach to the stick-slip behavior of faults

A fault which is treated as an array of asperities with a perscribed statistical distribution of strengths is described. For a linear array the stress is transferred to a single adjacent asperity and for a two dimensional array to three adjacent asperities. It is shown that the solutions bifurcate at a critical applied stress. At stresses less than the critical stress virtually no asperities fail on a large scale and the fault is locked. At the critical stress the solution bifurcates and asperity failure cascades away from the nucleus of failure. It is found that the stick slip behavior of most faults can be attributed to the distribution of asperities on the fault. The observation of stick slip behavior on faults rather than stable sliding, why the observed level of seismicity on a locked fault is very small, and why the stress on a fault is less than that predicted by a standard value of the coefficient of friction are outlined.

Smalley, R. F., Jr.↗

Dislocation model for aseismic fault slip in the transverse ranges of Southern California

Geodetic data at a plate boundary can reveal the pattern of subsurface displacements that accompany plate motion. These displacements are modelled as the sum of rigid block motion and the elastic effects of frictional interaction between blocks. The frictional interactions are represented by uniform dislocation on each of several rectangular fault patches. The block velocities and fault parameters are then estimated from geodetic data. Bayesian inversion procedure employs prior estimates based on geological and seismological data. The method is applied to the Transverse Ranges, using prior geological and seismological data and geodetic data from the USGS trilateration networks. Geodetic data imply a displacement rate of about 20 mm/yr across the San Andreas Fault, while the geologic estimates exceed 30 mm/yr. The prior model and the final estimates both imply about 10 mm/yr crustal shortening normal to the trend of the San Andreas Fault. Aseismic fault motion is a major contributor to plate motion. The geodetic data can help to identify faults that are suffering rapid stress accumulation; in the Transverse Ranges those faults are the San Andreas and the Santa Susana.

Cheng, A.↗

A preliminary transient-fault experiment on the SIFT computer system

This paper presents the results of a preliminary experiment to study the effectiveness of a fault-tolerant system's ability to handle transient faults. The primary goal of the experiment was to develop the techniques to measure the parameters needed for a reliability analysis of the SIFT computer system which includes th effects of transient faults. A key aspect of such an analysis is the determination of the effectiveness of the operating system's ability to discriminate between transient and permanent faults. A detailed description of the preliminary transient fault experiment along with the results from 297 transient fault injections are given. Although not enough data was obtained to draw statistically significant conclusions, the foundation has been laid for a large-scale transient fault experiment.

Butler, Ricky W.↗

Hardware fault insertion and instrumentation system: Mechanization and validation

Automated test capability for extensive low-level hardware fault insertion testing is developed. The test capability is used to calibrate fault detection coverage and associated latency times as relevant to projecting overall system reliability. Described are modifications made to the NASA Ames Reconfigurable Flight Control System (RDFCS) Facility to fully automate the total test loop involving the Draper Laboratories' Fault Injector Unit. The automated capability provided included the application of sequences of simulated low-level hardware faults, the precise measurement of fault latency times, the identification of fault symptoms, and bulk storage of test case results. A PDP-11/60 served as a test coordinator, and a PDP-11/04 as an instrumentation device. The fault injector was controlled by applications test software in the PDP-11/60, rather than by manual commands from a terminal keyboard. The time base was especially developed for this application to use a variety of signal sources in the system simulator.

Benson, J. W.↗

Design and validation of fault-tolerant flight systems

Flight systems must be validated to show that they are consistent with the requirements of their intended applications. While high reliability is difficult to validate, the additional complexity of fault tolerance further compounds the validation problem. The objective of NASA’s research is to develop a methodology for designing validatable fault-tolerant systems. Under the design-for-validation philosophy, emphasis is placed on developing validation methods that can be incorporated into the design process right from the start and design methods and guidance which, while incorporating fault tolerance, can assure validatability. This paper examines the statistical issues of validating highly reliable, fault tolerant system. There are many problems associated with traditional methods of designing and validating these potentially complex hardware and software systems. Useful design-for-validation methods, which include structured specification and design methodologies, mathematical proof techniques, analytical modeling, simulation and emulation, and physical testing, are discussed. Important design issues associated with fault tolerance are presented along with the related validation concerns which must be addressed. Experience has shown that synchronization and Byzantine resilience must accompany fault tolerance. Other design attributes associated with fault tolerance may be used by a designer on the basis of cost, weight, performance, and validation considerations.

Computer systems↗

An autonomous fault detection, isolation, and recovery system for a 20-kHz electric power distribution test bed

Future space explorations will require long term human presence in space. Space environments that provide working and living quarters for manned missions are becoming increasingly larger and more sophisticated. Monitor and control of the space environment subsystems by expert system software, which emulate human reasoning processes, could maintain the health of the subsystems and help reduce the human workload. The autonomous power expert (APEX) system was developed to emulate a human expert's reasoning processes used to diagnose fault conditions in the domain of space power distribution. APEX is a fault detection, isolation, and recovery (FDIR) system, capable of autonomous monitoring and control of the power distribution system. APEX consists of a knowledge base, a data base, an inference engine, and various support and interface software. APEX provides the user with an easy-to-use interactive interface. When a fault is detected, APEX will inform the user of the detection. The user can direct APEX to isolate the probable cause of the fault. Once a fault has been isolated, the user can ask APEX to justify its fault isolation and to recommend actions to correct the fault. APEX implementation and capabilities are discussed.

Quinn, Todd M.↗

Delivery and application of precise timing for a traveling wave powerline fault locator system

The Bonneville Power Administration (BPA) has successfully operated an in-house developed powerline fault locator system since 1986. The BPA fault locator system consists of remotes installed at cardinal power transmission line system nodes and a central master which polls the remotes for traveling wave time-of-arrival data. A power line fault produces a fast rise-time traveling wave which emanates from the fault point and propagates throughout the power grid. The remotes time-tag the traveling wave leading edge as it passes through the power system cardinal substation nodes. A synchronizing pulse transmitted via the BPA analog microwave system on a wideband channel sychronizes the time-tagging counters in the remote units to a different accuracy of better than one microsecond. The remote units correct the raw time tags for synchronizing pulse propagation delay and return these corrected values to the fault locator master. The master then calculates the power system disturbance source using the collected time tags. The system design objective is a fault location accuracy of 300 meters. BPA's fault locator system operation, error producing phenomena, and method of distributing precise timing are described.

Street, Michael A.↗

A verified design of a fault-tolerant clock synchronization circuit: Preliminary investigations

Schneider demonstrates that many fault tolerant clock synchronization algorithms can be represented as refinements of a single proven correct paradigm. Shankar provides mechanical proof that Schneider's schema achieves Byzantine fault tolerant clock synchronization provided that 11 constraints are satisfied. Some of the constraints are assumptions about physical properties of the system and cannot be established formally. Proofs are given that the fault tolerant midpoint convergence function satisfies three of the constraints. A hardware design is presented, implementing the fault tolerant midpoint function, which is shown to satisfy the remaining constraints. The synchronization circuit will recover completely from transient faults provided the maximum fault assumption is not violated. The initialization protocol for the circuit also provides a recovery mechanism from total system failure caused by correlated transient faults.

Miner, Paul S.↗