Comparison of theoretical and flight-measured local flow aerodynamics for a low-aspect-ratio fin

Flight test and theoretical aerodynamic data were obtained for a flight test fixture mounted on the underside of an F-104G aircraft. The theoretical data were generated using two codes, a two dimensional transonic code called Code H, and a three dimensional subsonic and supersonic code call wing-body. Pressure distributions generated by the codes for the flight test fixture as well as boundary layer displacement thickness generated by the two dimensional code were compared to the flight test data. The two dimensional code pressure distributions compared well except at the minimum pressure point and trailing edge. Shock locations compared well except at high transonic speeds. The three dimensional code pressure distributions compared well except at the trailing edge of the flight test fixture. The two dimensional code does not predict displacement thickness of the flight test fixture well.

Johnson, J. B.↗

Comparison of theoretical and flight-measured local flow aerodynamics for a low-aspect-ratio fin

Flight test and theoretical aerodynamic data were obtained for a flight test fixture mounted on the underside of an F-104G aircraft. The theoretical data were generated using two codes: a two-dimensional transonic code called code H, and a three-dimensional subsonic and supersonic code called wing-body. Pressure distributions generated by the codes for the flight test fixture, as well as compared with the flight-measured data. The two-dimensional code pressure distributions compared well except at the minimum pressure point and the trailing edge. Shock locations compared well except at high transonic speeds. However, the two-dimensional code did not adequately predict the displacement thickness of the flight test fixture. The three-dimensional code pressure distributions compared well except at the trailing edge of the flight test fixture.

Johnson, J. Blair↗

Space ultra-vacuum facility and method of operation

A wake shield facility providing an ultrahigh vacuum level for space processing is described. The facility is in the shape of a truncated, hollow hemispherical section, one side of the shield convex and the other concave. The shield surface is preferably made of material that has low out-gassing characteristics such as stainless steel. A material sample supporting fixture in the form of a carousel is disposed on the convex side of the shield at its apex. Movable arms, also on the convex side, are connected by the shield in proximity to the carousel, the arms supporting processing fixtures, and providing for movement of the fixtures to predetermined locations required for producing interations with material samples. For MBE processes a vapor jet projects a stream of vaporized material onto a sample surface. The fixtures are oriented to face the surface of the sample being processed when in their extended position, and when not in use they are retractable to a storage position. The concave side of the shield has a support structure including metal struts connected to the shield, extending radially inward. The struts are joined to an end plate disposed parallel to the outer edge of the shield. This system eliminates outgassing contamination.

Naumann, Robert J.↗

Design, analysis, and testing of a reusable wingbox for ballistic evaluation of composite structures

Future fighter aircraft will continue to be subjected to severe mechanical loading and ballistic impact. In the past aircraft primary wing structure was constructed predominantly with aluminum, but with increasing aircraft performance the need for more structurally efficient materials is necessary. In an attempt to achieve structural efficiency requirements, aircraft designers have begun using an increasing amount of composite materials. Composite materials were indicated to have a low level of ballistic tolerance in some applications. Composite materials possess the characteristic of structural tailoring, which was utilized to demonstrate that survivability can be designed into a structure. The combat flight environment subjects fighter aircraft wing structures to the effects of combined loading during ballistic impact. These loads were previously demonstrated independently, i.e., the application of structural load, hydrodynamic ram damage, and the effects of airflow. The objective was to design a reusable test fixture for the ballistic evaluation of advanced composite structures under all the effects of combined loading. The fixture that was developed provides a test bed that can completely simulate the flight environment of a generic fighter aircraft wing, but can be used for an indefinite number and variety of tests. It is intended that this fixture will provide a standardized method of ballistically evaluating an advanced composite primary wing structure. This fixture will be used to accomplish the development of designs and/or advanced concepts that lead to a survivable composite wing structure.

Baron, W. G.↗

Compression-after-impact testing of thin composite materials

A new method has been devised to test composite specimens as thin as 8 plies and up to 7.6 cm in width for compression strength. This method utilizes a fixture incorporating the best features of the Celanese and IITRI fixtures combined with an antibuckling jig developed at the University of Dayton Research Institute. This new method uses up to 83 percent less material than the most commonly used compression-after-impact technique (which calls for a 48 ply test specimen) and can also be performed on smaller loading frames since a much smaller force is needed to fail the specimen. The thickness of the test specimen can be fabricated to exactly match production part thickness, thus yielding more meaningful results. CAI tests were performed on IM6/3501 carbon/epoxy utilizing this new method. To verify the design, a series of tests were performed in which undamaged specimens were tested using the new fixture and ASTM D 3410-87 (Celanese compression test) and the results compared. The new fixture works well and will be a valuable asset to MSFC's damage tolerance program.

Nettles, Alan T.↗

Design and Evaluation of Composite Fuselage Panels Subjected to Combined Loading Conditions

Methodologies used in industry for designing transport aircraft composite fuselage structures are discussed. Several aspects of the design methodologies are based on assumptions from metallic fuselage technology which requires that full-scale structures be tested with the actual loading conditions to validate the designs. Composite panels which represent crown and side regions of a fuselage structure are designed using this approach and tested in biaxial tension. Descriptions of the state-of-the-art test facilities used for this structural evaluation are presented. These facilities include a pressure-box test machine and a D-box test fixture in a combined loads test machine which are part of a Combined Loads Test System (COLTS). Nonlinear analysis results for a reference shell and a stiffened composite panel tested in the pressure-box test machine with and without damage are presented. The analytical and test results are compared to assess the ability of the pressure-box test machine to simulate a shell stress state with and without damage. A combined loads test machine for testing aircraft primary structures is described. This test machine includes a D-box test fixture to accommodate curved stiffened panels and the design features of this test fixture are presented. Finite element analysis results for a curved panel to be tested in the D-box test fixture are also discussed.

Ambur, Damodar R.↗

Torque-Limiting Manipulation Device

A device for manipulating a workpiece in space includes a fixture, a stanchion assembly, a manipulation mechanism, an actuation mechanism, and a reaction mechanism. The fixture has an end onto which the workpiece affixes. The stanchion assembly has an upper and a lower end. The manipulation mechanism connects the fixture and the upper end of the stanchion assembly. The lower end of the stanchion assembly mounts, via probe and a socket, to a structure. The actuation mechanism operably connects to the manipulation mechanism, and moves the fixture in space. The reaction mechanism provides a point through which force inputs into the actuation mechanism may react.

Moetteli, John B.↗

Simulated Space Environmental Testing on Thin Films

An exploratory program has been conducted, to irradiate some mature commercial and some experimental polymer films with radiation simulating certain Earth orbits, and to obtain data about the response of each test film's reflective and tensile properties. Protocols to conduct optimized tests were considered and developed to a "prototype" level during this program. Fifteen polymer film specimens were arranged on a specially designed test fixture. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture featured controlled exposure areas, and protected the ends of the samples for later gripping in tensile tests. The fixture containing the films was installed in a clean vacuum chamber where protons, electrons and solar ultraviolet (UV) radiation could simultaneously irradiate the specimens. Near realtime UV rates were used, whereas proton and electron rates were accelerated appreciably to simulate 5 years in orbit during a two month test. Periodically, the spectral reflectance of each film was measured in situ. After the end of the irradiation, final reflectance measurements were made in situ, and solar absorptance values were derived for each specimen. These samples were then measured in air for thermal emittance and for tensile strength. Most specimens withstood the irradiation intact, but with reduced reflectance (increased solar absorptance). Thermal emittance changed slightly in several materials, as did their tensile strength and elongation at break. Conclusions are drawn about the performance of the films. Simulated testing to an expected 5 year dose of electrons and protons consistent with those expected at L2 and 0.98 AU orbits and 100 equivalent solar hours exposure.

Russell, Dennis A.↗

Braided Carbon Fiber Rope Flow Characteristics

I am submitting the following technical subject for consideration as a thesis topic for the master degree: The reusable solid rocket motor (RSRM) nozzle internal joints are being evaluated for the incorporation of a carbon fiber rope (CFR) as a thermal barrier. The CFR is approximately 0.260 in. diameter and is composed of approximately 12,000 carbon fibers, woven in ten sheaths or layers. The CFR is manufactured by a sub-tier vendor and subsequently several of its manufacturing details are proprietary to that vendor. The CFR design intent is to prevent hot motor combustion products and slag from intruding into the joint scaling area while still approaching a vented joint design to avoid the detriments of gas jet impingement. As a member of the Heat Transfer section at Thiokol Propulsion, two main goals exist as part of this NASA funded design effort: (1) development of flow model through the CFR and (2) development of a heat transfer model through the CFR. While both models are needed and most probably interrelated, the gas flow model is being targeted as the subject matter. Essentially, the topic would be "Modeling of Gas Flow through a Braided Carbon Fiber Rope". An AIAA journal or conference paper is being considered through Thiokol/NASA as well. A sub-scale CFR flow test fixture was designed to simulate the relative levels of CFR compression. The test fixture provides the means to measure gas mass flow rate upstream of the CFR and the pressure and temperature both upstream and downstream of the CFR. The test fixture was designed to eliminate the possibility of dynamic gapping at the CFR location and provide minimal flow resistance to ambient for gases exiting the rope. The data collected in the experiment will be evaluated to define a permeability/flow resistance model. Two possibilities exist for the flow characteristics through the CFR from choked flow to strictly friction driven. A test matrix for evaluating the CFR has been compiled, which addresses both of these characteristics. The range of pressures to be tested covers a relatively low delta pressure where non-choked flow is impossible, while the high pressure shown is dictated by the RSRM joint operating pressure where choking is possible. The test matrix, was also designed for a range of rope compressions or test fixture gaps ranging from 0.025" to 0.070". These gaps are controlled by the range of RSRM full-scale hardware joint gaps that will be expected by virtue of the joint design.

Heman, J. R. C.↗

Optical Alignment of the JWST ISIM to the OTE Simulator (OSIM): Current Concept and Design Studies

The James Webb Space Telescope's (JWST) Integrated Science Instrument Module (ISIM) is the scientific payload of the observatory and contai ns four science instruments. During alignment and test of the integrated ISIM (i.e. ISIM + science instruments) at NASA's Goddard Space Fli ght Center (GSFC), the Optical telescope element SIMulator (OSIM) wil l be used to optically stimulate the science instruments to verify their operation and performance. In this paper we present the design of two cryogenic alignment fixtures that will be used to determine and verify the proper alignment of OSIM to ISIM during testing at GSFC. The se fixtures, the Master Alignment Target Fixture (MATF) and the ISIM Alignment Target Fixture (IATF), will provide continuous, 6 degree of freedom feedback to OSIM during initial ambient alignment as well as during cryogenic vacuum testing.

Frey, Bradley J.↗

Deployable Aeroshell Flexible Thermal Protection System Testing

Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

Hughes, Stephen J.↗

Computer Controlled Solid State Lighting Assembly to Emulate Diurnal Cycle and Improve Circadian Rhythm Control

A light system can simultaneously emulate more than one different diurnal cycle to individually improve circadian rhythm control for more than one observer by having each light fixture autonomously self-controlled. Each light fixture is mountable in respective locations to individually treat respective observers. Each light fixture includes one or more light elements mounted to a housing and are controllable to emit a selected light intensity at a selected light temperature. A micro controller is contained in the housing and includes memory containing instructions for one or more automatic diurnal cycle protocols. The micro controller is in communication with the memory and the one or more light elements to execute the instructions to configure the light fixture to vary the light intensity and the light temperature of the emitted light.

Holbert, Eirik↗

Restore-L Satellite Servicing Internship Final Report

An experiment was conducted to determine whether a sample of shorter flexible metal hoses could sustain tensile loads of up to 200 lbf and continue to meet the minimum mission requirements. The purpose of this experiment was to determine if tension loads during the processing of the hoses compromise performance. With this information, it will be decided whether the flight flex-hose manufacturer should proceed with the testing of the full-scale flex-hoses. To reduce the time and funding required for this test, a test fixture was designed and assembled in the Engineering Development & Operations (EDO) test facility. In this test fixture, two Engineering Development Unit (EDU) flex-hoses were loaded with free floating weights up to 350 lbf. A load of 200 lbf equates to the maximum expected loading with a margin of safety, thus all data recorded after 200 lbf was purely for reference. Measurements were taken using a tape measure and a custom datum measurement system to record the loaded and unloaded length of each flex-hose at various loads. Any permanent stretching beyond a 1/8th of an inch was indicative of inelastic yielding. The loading of each flex-hose was done with an initial weight 80 lbf and was increased to 100 lbf. Additional loading up to 350 lbf was done by 50 lbf increments thereafter. During the performance of the test, slippage occurred in the mounting of the flex-hoses in the test fixture. The first slippage occurred during the testing of the first flex-hose due to the collar of the flex-hose slipping within the collet of the top Kellem. As a result, the first flex-hose test was terminated early to modify the fixture. Due to the flex-hose not inelastically yielding, the test was repeated on the first flex hose. This test resulted in another instance of slippage in the upper collar of the Kellem due to tape interfering with the securing of a collet around the collar of the flex-hose. The test was then continued with one more slippage of the flex-hose within the collet of the bottom Kellem. Preventive measures were taken for future slippage, and the second hose remained secure during testing.Once the tests were concluded, the elongation of each hose was analyzed for inelastic yielding. Both flex-hoses stretched a measurable and repeatable amount under loading, however, this stretching was recovered once each hose was unloaded. As a result, both EDU flex-hoses did not experience any inelastic yielding during the tension testing. Once received, one additional flex-hose will be tested for yielding, but at the time of this paper, the recommendation is to proceed with testing of the full-scale flex-hoses at the flex-hose manufacturer.

Dziekan, Joseph↗

High-performance space shuttle auxiliary propellant valve system

Several potential valve closures for the space shuttle auxiliary propulsion system (SS/APS) were investigated analytically and experimentally in a modeling program. The most promising of these were analyzed and experimentally evaluated in a full-size functional valve test fixture of novel design. The engineering investigations conducted for both model and scale evaluations of the SS/APS valve closures and functional valve fixture are described. Preliminary designs, laboratory tests, and overall valve test fixture designs are presented, and a final recommended flightweight SS/APS valve design is presented.

Smith, G. M.↗

Evaluation of a metal shear web selectively reinforced with filamentary composites for space shuttle application. Phase 2: summary report: Shear web component fabrication

The fabrication of two shear web test elements and three large scale shear web test components are reported. In addition, the fabrication of test fixtures for the elements and components is described. The center-loaded beam test fixtures were configured to have a test side and a dummy or permanent side. The test fixtures were fabricated from standard extruded aluminum sections and plates and were designed to be reuseable.

Laakso, J. H.↗

Shuttle antenna radome technology test program. Volume 2: Development of S-band antenna interface design

The effects of the Thermal Protection Subsystem (TPS) contamination on the space shuttle orbiter S band quad antenna due to multiple mission buildup are discussed. A test fixture was designed, fabricated and exposed to ten cycles of simulated ground and flight environments. Radiation pattern and impedance tests were performed to measure the effects of the contaminates. The degradation in antenna performance was attributed to the silicone waterproofing in the TPS tiles rather than exposure to the contaminating sources used in the test program. Validation of the accuracy of an analytical thermal model is discussed. Thermal vacuum tests with a test fixture and a representative S band quad antenna were conducted to evaluate the predictions of the analytical thermal model for two orbital heating conditions and entry from each orbit. The results show that the accuracy of predicting the test fixture thermal responses is largely dependent on the ability to define the boundary and ambient conditions. When the test conditions were accurately included in the analytical model, the predictions were in excellent agreement with measurements.

Kuhlman, E. A.↗

Rail shear test method

The results of both an experimental test program and a finite element analysis of selected graphite/polyimide rail shear test specimens are discussed. The two dimensional finite element analysis includes both mechanical and thermal loading (differential expansion) of the specimens and their elastic rails. Parameters in this analysis of unidirectional and symmetric, balanced angle-ply laminates include ply layup angles, the effect of flexible rails, the method of load introduction to the specimen and the effect of uniform heating of the specimen and rails. Two types of tensile rail shear fixtures were investigated experimentally: a uniform thickness, bolted-rail shear fixture loaded diagonally across the specimen test section; and a tapered thickness, bonded-rail shear fixture loaded axially along the center-line of the specimen test section. Test results include room-temperature and 589K strain data taken from the center of the specimen test section during loading.

Garcia, R.↗

Multiple-creep-test apparatus

Simplified, compact apparatus uses fixtures that can test three samples at once for flexure, compression, or double-shear creep. Each fixture uses series of rods and plates to divide one load equally among three samples. Fixtures could be expanded to carry more samples by adding more rods and plates.

Haehner, C. L.↗