Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow improvers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Relationships Between Mesoscale Convective System Properties and Midlevel Dynamic Perturbations

Abstract Past studies implicate dynamic anomalies operating on subsynoptic scales as a possible initiation source of summertime (July–August) mesoscale convective systems (MCSs) in the central United States during northwesterly flow regimes. To improve our understanding of warm season MCSs occurring over a variety of flow regimes, we track midlevel (600 hPa) vorticity perturbations (“MPs”) as 2D objects comprising wavelengths of 500–2,500 km over the central US from May–August of 2004–2021. We perform statistical analysis of relationships between metrics of MP objects (e.g., duration, size, intensity, and origin) and high‐resolution MCS precipitation characteristics (e.g., duration, total rainfall, rain coverage area, and motion) that occur while collocated with or in the absence of MPs to discern predictive capability of background dynamic features on storm precipitation potential. Although the majority of MPs collocated with MCS initiation occur during July–August, a significant number (40%) occur between May and June. Northwesterly flow MPs comprise a relative minority of our events, suggesting that MPs can affect MCSs across a variety of warm season flow regimes. MPs affecting MCSs initiated primarily over the high plains near the central Rockies. Only approximately 20% of tracked MCS initiation events were collocated with MPs, but these storms produced ∼25% greater lifetime rainfall and coverage area, and ∼29% more stratiform rain than non‐MP‐induced MCSs. In general, larger and more vigorous MPs resulted in more hydrologically impactful MCSs. The most directly attributable benefit to MCS initiation was from MP‐enhanced background vertical motion and thermodynamic instability (e.g., increased CAPE).

54 ENVIRONMENTAL SCIENCES↗

Improving I/O-aware Workflow Scheduling via Data Flow Characterization and trade-off Analysis

The scientific computing paradigm has transitioned from compute-intensive to I/O-intensive and memory-intensive in the past decade, especially when data-driven science has become common practice. Numerous empirical I/O-aware scheduling optimizations have been developed by incorporating I/O capacity and bandwidth as constraints into scheduling. Unfortunately, there is a lack of data flow (I/O) characterization tool and an understanding of trade-offs between concurrency, locality, and I/O bandwidth. To bridge the gap, this work 1) presents a set of descriptors to characterize, organize, and visualize I/O profiles, including flow size, I/O bandwidth, and operation count, which group data flows by I/O types, tasks, and files; 2) proposes an I/O Roofline model-based trade-off analysis to find the optimal trade-off between flow operational intensity, concurrency, and flow performance. The I/O descriptors generate useful insights into complicated I/O behaviors, suggesting distinct concurrency, storage, and scheduling to be used by types, tasks, and files. The proposed trade-off analysis guides scheduling decisions that generate resource assignment with the best flow parallelism. We evaluate our I/O-aware scheduling methodology on a highly I/O-intensive workflow–1000 Genomes. The experimental results demonstrate speedups of up to 2.4× compared to the state-of-the- art methods.

Guo, Luanzheng [BATTELLE (PACIFIC NW LAB)]↗

Rational Evaluation and Cycle Life Improvement of Quinone-Based Aqueous Flow Batteries Guided by In-Line Optical Spectrophotometry

We measure electrolyte concentration and state-of-charge in real time in an operating aqueous anthraquinone-based flow battery using in-line optical spectrophotometry. By capitalizing on the linear transition in absorption spectra between oxidized and reduced states, we show how discontinuous capacity fade rates in redox flow batteries can be caused by a transition from one capacity-limiting electrolyte to the other, which is caused by reactant crossover. With this insight, we demonstrate an electrolyte-balancing scheme, which can be broadly applicable to flow battery systems with asymmetric electrolyte crossover rates.

25 ENERGY STORAGE↗

High-Capacity Organic Radical Mediated Phosphorus Anode for Sodium-Based Redox Flow Batteries

An innovative approach to improve the energy density of redox flow batteries (RFBs) through electrochemically mediated reactions is demonstrated. Soluble anion radical species (biphenyl and pyrene) mediate reversible sodium storage in a red phosphorus (P) anode located in an external packed bed reactor in the absence of binders or conductive additives. Because the anion radical species can be recycled several times through the cell stack during a single charge/discharge cycle, a mediated RFB effectively decouples the battery’s energy density from the redox species’ solubility in the electrolyte. The present study demonstrates the highest capacity reported to date for a mediated anode (up to 800 mAh/gP via reversible formation of Na x P). Finally, this approach represents a paradigm shift in the field and can conceivably achieve energy densities exceeding 200 Wh/kg, which is ~10 times greater than that of conventional RFBs (e.g., 25 Wh/kg for an aqueous vanadium system).

25 ENERGY STORAGE↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Accurate solar radiation measurements using pyranometers are required to understand radiative impacts on the Earth's energy budget, solar energy production, and to validate radiative transfer models. Ventilators of pyranometers, which are used to keep the domes clean and dry, also affect instrument thermal offset accuracy. This poster presents a high-level overview of the ventilators for single-black-detector pyranometers and black-and-white pyranometers. For single-black-detector pyranometers with ventilators, high-flow-rate (50-CFM and higher), 12-V DC fans lower the offsets, lower the scatter, and improve the predictability of nighttime offsets compared to lower-flow-rate (35-CFM), 120-V AC fans operated in the same type of environmental setup. Black-and-white pyranometers, which are used to measure diffuse horizontal irradiance, sometimes show minor improvement with DC fan ventilation, but their offsets are always small, usually no more than 1 W/m2, whether AC- or DC-ventilated.

54 ENVIRONMENTAL SCIENCES↗

Developing And Scaling an OpenFOAM Model to Study Turbulent Flow in a HFIR Coolant Channel

Improving the understanding of how computational fluid dynamics (CFD) direct numerical simulations (DNS) of flows in the High Flux Isotope Reactor (HFIR) perform when run in parallel using the high performance computing (HPC) platform Summit at the Oak Ridge Leadership Computing Facility (OLCF) is of particular importance to boost the computational tools used to support HFIR conversion to low enriched fuel (LEU). Evaluation of scaling performance was driven by the increasing importance of graphics processing unit (GPU) usage in HPC, which is becoming the standard for modern supercomputers such as Summit. The desired results are to obtain a strong positive correlation between the computational resources dedicated to a problem and the relative speed-up of the simulation in comparison to a benchmark. This capability will allow substantially improvement in HFIR flow analytical capabilities, specifically when predicting turbulence properties at high Reynolds numbers. The study leverages previous simulation results performed with code PHASTA (finite element) on HPC platforms Cori (NERSC) and Theta (ALCF) [1] with computing options provided in the computing platform OpenFOAM (finite volume) at OLCF. Transitioning from PHASTA to OpenFOAM will (1) eliminate dependence on third-party software for mesh generation and manipulation, (2) reduce resource needs by employing modern architectures, and (3) build expertise for future modeling of HFIR-specific problems like heat transfer in involute geometry, entrance effects, flow structure in channel corners, and so on—all important issues when defining the available thermal margins in the transition to LEU. CPUs and GPUs differ significantly in their architecture and utilization, as discussed in the literature [2]. The most important differences are in the approach to computations and their memory. A single GPU contains a large quantity of cores, enabling it to perform with a much higher throughput than a CPU, but execution requires a different approach. GPU codes execute instructions using the Single-Instruction Multiple-Thread (SIMT) approach in which a single instruction is used for groups of threads called warps. A warp typically consists of 32 threads which must execute the same set of instructions, although on separate threads. Alternately, a CPU has far fewer cores that are much more flexible in their operation, excelling at quickly performing more complex serial computations. This is why GPUs have greater throughput when properly utilized. The second important difference is seen when comparing their memory spaces. Limited memory allocations and CPU–GPU communications cause a significant bottleneck in GPU-accelerated programs. Further study was required to properly take advantage of GPU resources. A comprehensive analysis of code performance and the model-specific features of turbulence constitutes the core of this work. In this study, a DNS simulation of HFIR channel turbulence was performed with the finite volume CFD code OpenFOAM v2112 and CUDA v11.0 on Red Hat Enterprise Linux v8.2. The OpenFOAM installation had AMGx integrated to enable GPU acceleration and utilizes the PETSc4FOAM library. The computational resources and the problem size were scaled on CPU and CPU + GPU architectures to gain a better understanding of the performance of a DNS problem on modern computing hardware. The study aimed to analyze the scaling of the code exclusively on CPUs and then to examine the scaling of the codes with GPU acceleration enabled. Scaling studies included CPU and GPU acceleration on a mesh of varying resolution to analyze the impact of problem size relative to computational resources. In the course of preparing the GPU configuration on Summit, mainly using the AMGX solvers, difficulties were encountered stemming from constant changes resulting from extensive ongoing development activities and the changing environment. This resulted in the inability to complete the GPU portion of the work. The code was compiled and tested, but production runs to assess acceleration were not performed because the used discretional compute time allocation expired as year-end approached. The Summit HPC platform is scheduled for decommissioning in 2024, making it unattractive for future use with Nvidia-based GPUs. Therefore, the work will be moved onto NERSC machines in FY24. An application was prepared and submitted, and sufficient node-hours were awarded to continue the research in the next calendar year. This report summarizes work performed thus far, which mostly focused on CPU OpenFOAM computing.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Enhancing Streamflow Reanalysis Across the Conterminous US Leveraging Multiple Gridded Precipitation Data Sets

Streamflow observations, essential for various water resource applications, are often unavailable at critical locations in need. Although different models have been proposed to enhance streamflow predictability at ungauged locations, the challenge extends beyond model fidelity. Differences in meteorologic forcing data sets, precipitation in particular, can significantly affect the accuracy of hydrologic predictions. This challenge intensifies across regions characterized by diverse hydro-climatological and geographical conditions, such as in the conterminous US (CONUS) where a single precipitation product struggles to consistently replicate observed hydrographs, particularly peak flow dynamics. To enhance streamflow predictions, we utilize a VIC-RAPID hydrologic modeling framework driven by multiple commonly used meteorological forcing data sets, such as Daymet, PRISM, ST4, AORC, and their hybrids and create multiple sets of 40-year (1980–2019) hourly, daily, and monthly streamflow reanalysis, Dayflow Version 2, for 2.7 million river reaches across the CONUS. Most forcings lead to skillful streamflow performance, except for ST4 in the mountainous west, where severe radar blockage adversely affects the accuracy. The evaluation using over 6,000 hourly stream gauges shows that hourly AORC and ST4 lead to improved annual peak flow performance over Daymet—driven streamflow (Dayflow V1), particularly in smaller basins, highlighting the value of high temporal resolution forcings in hydrologic predictions. Compared with other benchmark data sets like National Water Model V3.0, AORC-driven VIC-RAPID exhibits improved regional streamflow performance, with comparable peak flow representation. We envision that multi-forcing streamflow reanalysis data can inform regions in need of forcing data enhancement, diagnose hydrologic model performance, and benefit diverse water resource applications.

54 ENVIRONMENTAL SCIENCES↗

Exergy and Economic Analysis of Catalytic Coal Gasifiers Coupled With Solid Oxide Fuel Cells

The National Energy Technology Laboratory (NETL) has undertaken a review of coal gasification technologies that integrate with solid oxide fuel cells (SOFC) to achieve system efficiencies near 60% while capturing and sequestering >90% of the carbon dioxide. One way to achieve an overall system efficiency of greater than 60% is in a power plant in which a catalytic coal gasifier produces a syngas with a methane composition of roughly 25% on a dry volume basis and this is sent to a SOFC, with CO{sub 2} capture occurring either before or after the SOFC. Integration of a catalytic gasifier with a SOFC, as opposed to a conventional entrained flow gasifier, is improved due to (a) decreased exergy destruction inside a catalytic, steam-coal gasifier producing a high-methane content syngas, and (b) decreased exergy destruction in the SOFC due to the ability to operate at lower air stoichiometric flow ratios. For example, thermal management of the SOFC is greatly improved due to the steam-methane reforming in the anode of the fuel cell. This paper has two main goals. First, we converted the levelized cost of electricity (LCOE) estimates of various research groups into an average internal rate of return on investment (IRR) in order to make comparisons between their results, and to underscore the increased rate of return on investment for advanced integrated gasification fuel cell systems with carbon capture & sequestration (IGFC-CCS) compared with conventional integrated gasification combined cycle (IGCC-CCS) systems and pulverized coal combustion (PCC-CCS) systems. Using capital, labor, and fuel costs from previous researchers and using an average price of baseload electricity generation of $61.50 / MW-hr, we calculated inflation-adjusted IRR values of up to 13%/yr for catalytic gasification with pressurized fuel cell and carbon dioxide capture and storage (CCS), whereas we calculate an IRR of ~4%/yr and ~2%/yr for new, conventional IGCC-CCS and PCC-CCS, respectively. If the carbon dioxide is used for enhanced oil recovery rather than for saline aquifer storage, then the IRR values improve to 16%/yr, 10%/yr, and 8%/yr, respectively. For comparison, the IRR of a new conventional IGCC or PCC power plant without CO{sub 2} capture are estimated to be 11%/yr and 15.0%/yr, respectively. Second, we conducted an exergy analysis of two different configurations in which syngas from a catalytic gasifier fuels a SOFC. In the first case, the CO{sub 2} is captured before the SOFC, and the anode tail gas is sent back to the catalytic gasifier. In the second case, the anode tail gas is oxy-combusted using oxygen ion ceramic membranes and then CO{sub 2} is captured for sequestration. In both cases, we find that the system efficiency is greater than 60%. These values compare well with previous system analysis. In future work, we plan to calculate the IRR of these two cases and compare with previous economic analyses conducted at NETL.

01 COAL, LIGNITE, AND PEAT↗

Flow synthesis of iron oxide nanoparticles: using multiple precursor additions to improve size control

Controlling the size of iron oxide nanoparticles while maintaining uniformity in flow-based synthesis systems has been a great challenge in nanoparticle synthesis. Using an extended LaMer mechanism, we improve both the size and shape uniformity as compared to a conventional flow synthesis. The key to this approach is the injection of additional Fe precursor during the flow reaction, providing extra precursor during the growth process leading to a size focusing step. This approach has also allowed for the systematic variation of the nanoparticle size produced in the flow reaction. This work represent a new synthetic concept for improving the size uniformity of iron oxide nanoparticles in flow-based synthesis and has potential for application across a wide range of nanoparticle systems.

36 MATERIALS SCIENCE↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Air Flow Measurement Methods for Residential HVAC Returns

This project improved the accuracy of air flow measurements used in commissioning California heating and air conditioning systems in Title 24 (Building and Appliance Efficiency Standards), thereby improving system performance and efficiency of California residences. The research team at Lawrence Berkeley National Laboratory addressed the issue that typical tools used by contractors in the field to test air flows may not be accurate enough to measure return flows used in Title 24 applications. The team developed guidance on performance of current diagnostics as well as a draft test method for use in future evaluations. The series of tests performed measured air flow using a range of techniques and devices. The measured air flows were compared to reference air flow measurements using inline air flow meters built into the test apparatus. The experimental results showed that some devices had reasonable results (typical errors of 5 percent or less) but others had much bigger errors (up to 25 percent). Because manufacturers’ accuracy estimates for their equipment do not include many of the sources of error found in actual field measurements (and replicated in the laboratory testing in this study) it is essential for a test method that could be used to determine the actual uncertainty in this specific application. The study team prepared a draft test method through ASTM International to determine the uncertainty of air flow measurements at residential heating ventilation and air conditioning returns and other terminals. This test method, when finalized, can be used by the Energy Commission and other entities to specify required accuracy of measurement devices used to show compliance with standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Primary coolant flow measurement for integral pressurized water reactors using ultrasonic technique - 182

Several pressurized water reactor (PWR) systems under development employ integral primary coolant loop designs, where the primary coolant does not leave the reactor pressure vessel during operation (I{sup 2}S-LWR, mPower, NuScale). The absence of primary coolant piping inhibits traditional pressurized water reactor primary coolant flow measurement, in which the differential pressure across the steam generator is correlated to flow rate. To address this, a transit time, reflection mode, ultrasonic flow meter is proposed. An experimental flow loop utilizing a test section representative of a thin azimuthal slice of the down-comer region of an integral PWR has been constructed to test the efficacy of the General Electric AT600 ultrasonic flow meter (UFM) in such an application. A Great Plains Industries TM300 turbine flow meter (TFM), reporting volumetric flow rate and installed in-line with the flow loop piping, is used as the reference meter. UFM performance is affected by several factors, including flow development and symmetry. The UFM was installed on three locations along the flow path of water through the test section. The meter performed the best at the downstream end of the test section, where the fluid flow is the most developed. Performance, measured by percent error in UFM average reading with respect to the TFM average reading, generally improved with increasing flow rate at all locations, though absolute difference between meter readings increased with flow rate. This research suggests that ultrasonic approaches hold promise for non-invasive measurement of primary coolant flow in integral PWRs. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Significant Improvements in Pyranometer Nighttime Offsets Using High-Flow DC Ventilation

Abstract Ventilators are used to keep the domes of pyranometers clean and dry, but they affect the nighttime offset as well. This paper examines different ventilation strategies. For the several commercial single-black-detector pyranometers with ventilators examined here, high-flow-rate [50 cubic feet per minute (CFM) and higher] 12-VDC (where VDC refers to voltage direct current) fans lower the offsets, lower the scatter, and improve the predictability of the offsets during the night compared with lower-flow-rate (35 CFM) 120-VAC (where VAC refers to voltage alternating current) fans operated in the same ventilator housings. Black-and-white pyranometers sometimes show improvement with DC ventilation, but in some cases DC ventilation makes the offsets slightly worse. Since the offsets for these black-and-white pyranometers are always small, usually no more than 1 W m−2, whether AC or DC ventilated, changing their ventilation to higher CFM DC ventilation is not imperative. Future work should include all major manufacturers of pyranometers and unventilated and ventilated pyranometers. An important outcome of future research will be to clarify under what circumstances nighttime data can be used to predict daytime offsets.

14 SOLAR ENERGY↗

Refinement of Fread s Method for improved tracking of stream discharges during unsteady flows

There are a plethora of analytical approaches to account for the effect of unsteady flow (a.k.a. hysteretic behavior) on the conventionally-built steady rating curves (RCs) used to continuously estimate discharges in open channel flow. One of the most complete correction methods is Fread s method (Fread, 1975) which is based on fully dynamic one-dimensional wave equation. Proposed herein is a modified Fread s method which is adjusted to account for the actual geometry of the cross section. This method improves the accuracy associated with the estimation of conveyance factor and energy slope, so it is particularly useful for small to mid-size streams/rivers where the original method s assumption does not properly hold. The modified Fread s method is tested for the sites in Clear Creek (Iowa, USA) and Ebro River (Spain) to illustrate the significance of its improvement in discharge estimation. While the degree of improvement is apparent for the conveyance factor because the hydraulic depth is replaced by hydraulic radius, that for the energy slope term specifically depends on the site and event conditions.

54 ENVIRONMENTAL SCIENCES↗

Peridigm summary report : lessons learned in development with agile components.

This report details efforts to deploy Agile Components for rapid development of a peridynamics code, Peridigm. The goal of Agile Components is to enable the efficient development of production-quality software by providing a well-defined, unifying interface to a powerful set of component-based software. Specifically, Agile Components facilitate interoperability among packages within the Trilinos Project, including data management, time integration, uncertainty quantification, and optimization. Development of the Peridigm code served as a testbed for Agile Components and resulted in a number of recommendations for future development. Agile Components successfully enabled rapid integration of Trilinos packages into Peridigm. A cost of this approach, however, was a set of restrictions on Peridigm's architecture which impacted the ability to track history-dependent material data, dynamically modify the model discretization, and interject user-defined routines into the time integration algorithm. These restrictions resulted in modifications to the Agile Components approach, as implemented in Peridigm, and in a set of recommendations for future Agile Components development. Specific recommendations include improved handling of material states, a more flexible flow control model, and improved documentation. A demonstration mini-application, SimpleODE, was developed at the onset of this project and is offered as a potential supplement to Agile Components documentation.

99 GENERAL AND MISCELLANEOUS↗

Eddy Current Flow Meter Measurements and Modeling Validation

The goal of the eddy current flow meter (ECFM) is to monitor velocities and temperatures of conductive liquid metals. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of these flows can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core and aid in mapping any non-uniformities in fluid flow such as estimates of temperature and phase. While the eventual goal is to develop the ECFM for the liquid sodium surrounding the Versatile Test Reactor (VTR) core, this report focuses on modeling and experimental validation of ECFM for a moving solid test rod and for liquid mercury in the Target Test Facility (TTF) flow loop to better understand and further develop ECFM measurement capabilities by validating model predictions with benchmark experiments. Eventually the models could be used to design and optimize future ECFMs for specific applications such as monitoring flow within the VTR pool.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗