Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow induced vibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

202 records · Page 12

Influence of turbulence intensity on vortex pattern for a rigid cylinder with turbulence stimulation in flow induced oscillations

The effect of ambient turbulence intensity on the flow induced oscillations of rigid circular cylinders with symmetric and asymmetric local turbulence stimulation is studied. Cylinders oscillate in one degree of freedom transversely to a steady uniform flow. Two-dimensional unsteady Reynolds-Average Navier-Stokes equations with the Spalart-Allmaras turbulence model are used to solve the problem numerically. Three freestream turbulence intensity values (0.2%, 1%, 5%) are used to study the influence of turbulence intensity on vortex pattern. Simulation results are compared with experimental data measured in the Marine Renewable Energy Laboratory of the University of Michigan in the range of 30,000 ≤ Re ≤ 110,000. The amplitude ratio, lift coefficient, vortex modes, and the interactions between vortices and cylinders are observed and discussed. In conclusion, major conclusions are: (a) Vortex patterns strongly depend on the freestream ambient turbulence intensity. (b) Low turbulence intensity can generate multi-vortex patterns at high Re. (c) High turbulence intensity results in fewer separations of a shed vortex into multiple vortices inducing emergence of elongated vortex patterns.

42 ENGINEERING↗

Competing mechanisms at vibrated interfaces of density-contrast fluids

Fluid-fluid interfacial instability and subsequent fluid mixing are ubiquitous in nature and engineering. The hydrodynamic instability of fluid interfaces has long centered on the pressure gradient-driven long-wavelength Rayleigh-Taylor instability and the resonance-induced short-wavelength Faraday instability. However, neither instability alone can explain the dynamics when both mechanisms are present. We identify a previously unseen multi-modal instability emerging from their coexistence. When the denser fluid is polydimethylsiloxane, the mixed region at a high density contrast (Atwood number = 0.9) spans a vibration amplitude range approximately twice the gravitational acceleration. Using Floquet stability analysis, we show how vibrations govern transitions between the RT and Faraday instabilities, leading to contention between these instabilities rather than resonant enhancement. Here, the initial transient growth is represented by the exponential modal growth of the most unstable Floquet exponent, along with its accompanying periodic behavior. Direct numerical simulations validate these findings and track interface breakup into the multiscale and nonlinear regimes. Specifically, we show that growing RT modes nonlinearly suppresses Faraday responses even when the initial growth rate of the Faraday instability is 3.63 times that of RT, so a bidirectional competition hinders their sustained coexistence.

Direct numerical simulations↗

Simulating the Effect of Space Vehicle Environments on Directional Solidification of a Binary Alloy

Space microgravity missions are designed to provide a microgravity environment for scientific experiments, but these missions cannot provide a perfect environment, due to vibrations caused by crew activity, on-board experiments, support systems (pumps, fans, etc.), periodic orbital maneuvers, and water dumps. Therefore, it is necessary to predict the impact of these vibrations on space experiments, prior to performing them. Simulations were conducted to study the effect of the vibrations on the directional solidification of a dendritic alloy. Finite element ca!cu!attie?ls were dme with a simd2titcr based on a continuum model of dendritic solidification, using the Fractional Step Method (FSM). The FSM splits the solution of the momentum equation into two steps: the viscous intermediate step, which does not enforce continuity; and the inviscid projection step, which calculates the pressure and enforces continuity. The FSM provides significant computational benefits for predicting flows in a directionally solidified alloy, compared to other methods presently employed, because of the efficiency gains in the uncoupled solution of velocity and pressure. finite differences, arises when the interdendritic liquid reaches the eutectic temperature and concentration. When a node reaches eutectic temperature, it is assumed that the solidification of the eutectic liquid continues at constant temperature until all the eutectic is solidified. With this approach, solidification is not achieved continuously across an element; rather, the element is not considered solidified until the eutectic isotherm overtakes the top nodes. For microgravity simulations, where the convection is driven by shrinkage, it introduces large variations in the fluid velocity. When the eutectic isotherm reaches a node, all the eutectic must be solidified in a short period, causing an abrupt increase in velocity. To overcome this difficulty, we employed a scheme to numerically predict a more accurate value for the rate of change of fraction of liquid as the liquid in an element solidifies. The new method enables us to contrast results of simulations in which the alloy is subjected to no gravity or a steady-state acceleration versus simulations when the alloy is subjected to vibration disturbances; therefore, the effect of vibration disturbances can be assessed more accurately. To assess the impact of these vibration-perturbations, transient accelerometer data from a space shuttle mission are used as inputs for the simulation model. These on-orbit acceleration data were obtained from the Microgravity Science Division at Glenn Research Center (GRC- MSD) and are applied to the buoyancy term of the momentum equation in a simulation of a Pb-5.8 wt. % Sb alloy that solidifies in a thermal gradient of 4000 K/m and a translation velocity of 3 p d s . Figure 2 shows the vertical velocity of a node that begins in the all-liquid region and subsequently solidifies; the vibrations are applied at 5000 seconds in this simulation. An important difficulty, common to all solidification models based on finite elements or 2 The magnitudes of the velocity oscillations that are vibration-induced are very small and acceptable. The biggest concern is whether the concentration of the liquid near the dendrite tips is distorted because of the vibration-induced perturbations. Results for this case show no concentration oscillations present in the all-liquid region.

Westra, D. G.↗

SiC-Based Miniature High-Temperature Cantilever Anemometer

The figure depicts a miniature cantilever-type anemometer that has been developed as a prototype of compact, relatively nonintrusive anemometers that can function at temperatures up to 600 C and that can be expected to be commercially mass-producible at low cost. The design of this anemometer, and especially the packaging aspect of the design, is intended to enable measurement of turbulence in the high-temperature, high-vibration environment of a turbine engine or in any similar environment. The main structural components of the anemometer include a single-crystal SiC cantilever and two polycrystalline SiC clamping plates, all made from chemical-vapor-deposited silicon carbide. Fabrication of these components from the same basic material eliminates thermal-expansion mismatch, which has introduced spurious thermomechanical stresses in cantilever-type anemometers of prior design. The clamping plates are heavily oxidized to improve electrical insulation at high temperature. A cavity that serves as a receptacle for the clamped end of the cantilever is etched into one end of one clamping plate. Trenches that collectively constitute a socket for a multipin electrical plug (for connection to external electronic circuitry) are etched into the opposite end of this clamping plate. Metal strips for electrical contact are deposited on one face of the other clamping plate. Piezoresistive single-crystal SiC thin-film strain gauges are etched in the n-type SiC epilayer in a Wheatstone-bridge configuration. Metal contact pads on the cantilever that extend into the clamping-receptacle area, are obtained by deposition and patterning using standard semiconductor photolithography and etching methods. The cantilever and the two clamping plates are assembled into a sandwich structure that is then clamped in a stainless-steel housing. The Wheatstone- bridge carrying SiC cantilever with the metal contact pads on the piezoresistors is slid into the receptacle in the bottom clamping plate. The top clamping plate is brought into contact with the bottom plate so that the narrow section of the metal strips on the top clamp plate aligns with the metal contact pads on the cantilever. When the parts are clamped together, the metal strips provide electrical connections between the Wheatstone-bridge contact points and the sides the trenches that constitute the socket for the multipin electrical plug. Hence, to connect the Wheatstone bridge to external circuitry for processing of the anemometer readout, one need only insert the plug in the socket. In operation, the cantilever end of the stainless-steel housing is mounted flush with an engine wall and the unclamped portion of the cantilever is exposed into the flow. The cantilever is deflected in direct proportion to the force induced by component of flow parallel to the engine wall and perpendicular to the broad exposed face of the cantilever. The maximum strain on the cantilever occurs at the clamped edge and is measured by the piezoresistors, which are located there. The corresponding changes in resistance manifest themselves in the output of the Wheatstone bridge.

Okojie, Robert S.↗