At least 217 records · Page 12

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Prompt Gamma Analysis of ARIES Materials and Updates to the 2015 Calibration Equations

Prompt gamma (PG) analysis is a nondestructive, nuclear, elemental analysis technique that uses charged particle reactions to interrogate a sample, and elements present in the sample matrix are identified through the characteristic gamma-rays emitted from the product nuclei in alpha-p and alpha-n nuclear reactions. This technique has been applied to plutonium oxide packaged in over 4,000 individual 3013 containers, and the concentrations of certain light elements were determined from the integrated peak areas based on a calibration that was published previously. This report provides the results for a new population of 3013 containers packaged with oxide materials produced by the conversion of metal by Advanced Recovery and Integrated Extraction System (ARIES) project using the direct metal oxidation (DMO) process and muffle furnaces. New PG and analytical chemistry data collected since 2015 were added to the existing calibration data sets to refine the calibration parameters. Calibration equations were also developed for determining beryllium and fluorine at low concentrations in high-purity ARIES product oxides. The new fluorine calibration provides an order of magnitude greater sensitivity and results in an additional 1,408 containers in the original population identified as having fluorine as an impurity. Additionally, equations for calculating the lower limits of detection (LLDs) as a function of the actual counting time (live time) were obtained using WLS regression technique for samples in the calibration data set. This resulted in changes to the LLDs published previously.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Tank 9H Salt Dissolution Batch 2B in Support of Tank Closure Cesium Removal (TCCR) 1A Batch 2 Preparations

Savannah River Mission Completion (SRMC) is currently preparing the second batch of material to be processed through the Tank Closure Cesium Removal (TCCR) 1A system. The feed for TCCR 1A consists of dissolved saltcake from Tank 9H. The second batch of salt to make up processing Batch 2 (Batch 2B) has recently been dissolved in Tank 9H and transferred to Tank 10H where it was composited with the first part of the batch (Batch 2A) in preparation for processing through the TCCR 1A unit. Savannah River National Laboratory (SRNL) received samples from the recent batch (2B) of dissolved salt for characterization. Two samples from Batch 2B were received for characterization, a surface sample and a variable depth sample (VDS). Neither sample contained significant solids, although the VDS appeared slightly cloudy as compared to the surface sample. The sodium concentrations of both the surface and VDS filtrate samples were approximately 5.8 M, and the 137 Cs activity was 9.8E+07 dpm/mL in the surface sample and 9.5E+07 dpm/mL in the VDS. The total Cs concentrations were 2.5 mg/L and 2.4 mg/L in the surface sample and VDS, respectively, using the gamma activity and the Cs isotopic ratios determined by ICP-MS. The alpha activity was below the detection limit in both samples. Nitrate was the dominant anion present, and the samples were primarily concentrated sodium nitrate solutions with hydroxide, nitrite, and carbonate present at 0.1 – 0.2 M. In general, the Batch 2B samples were more dilute than the previously characterized Batch 2A samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Detector Characterization for SuperCDMS Commissioning

Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB is a next generation direct detection experiment search ing for low mass dark matter using cryogenic germanium and silicon detectors operated at millikelvin temperatures. As the experiment begins its first commissioning data taking, establishing that the detectors respond to energy deposits in a stable, predictable way is a prerequisite for any future physics analysis. This work presents a study of detector stability for four SuperCDMS SNOLAB detectors, det 7 and det 15 (germanium), and det 11 and det 14 (silicon), using two data sets taken during early commissioning: dedicated Barium-133 calibration runs, which provide a known gamma ray energy reference at 356 keV, and low background runs, which record whatever background radiation the detectors see with no external source present. The Ba-133 data do not show a distinct, well localized line at the expected energy, and the low background data show a baseline that drifts and oscillates over time rather than remaining flat. This baseline instability appears consistently across multiple channels rather than being confined to one, suggesting a shared, detector wide cause rather than a single faulty channel. Together, these observations point to the detectors’ cryogenic support system as the likely source of the instability, since small temperature fluctuations introduced during normal operation of the cooling system could plausibly couple into the exquisitely temperature sensitive detectors. These results inform the ongoing commissioning effort by narrowing down where instability in the current data is originating from.

O'Hanlon, Viktoria M. [Skidmore Coll.; Fermilab]↗

Limits on the non-thermal emission of the WR–WR system Apep

Colliding-wind binaries (CWBs) constitute an emerging class of γ-ray sources powered by strong, dense winds in massive stellar systems. The most powerful of them are those binaries hosting a Wolf-Rayet (WR) star. Following the recent discovery of Apep – the closest known Galactic WR–WR binary – we discuss the non-detection of its putative high-energy emission by the Fermi Large Area Telescope (Fermi-LAT) in this Letter. The limits reported in the GeV regime can be used to set a lower limit on the magnetic field pressure density within the shocked wind-collision region (WCR), and to exclude Apep as a bright γ-ray emitting binary. Given that this WR–WR system is the most luminous CWB identified until now at radio wavelengths, this result proves unambiguously that non-thermal synchrotron emission is not a suitable identifier for the subset of γ-ray emitters in this class of particle accelerators. Rather, Apep could be an interesting case of study for magnetic field amplification in shocked stellar winds.

79 ASTRONOMY AND ASTROPHYSICS↗

The spectra of IceCube Neutrino (SIN) candidate sources – III. Optical spectroscopy and source characterization of the full sample

A correlation between astrophysical high-energy neutrinos and blazars has been suggested by various authors. In particular, a likely association between IceCube events and intermediate- and high-energy peaked BL Lac objects has led to a sample of 47 objects having a high probability of being neutrino sources. In the first paper of this series we reported optical spectroscopy of 17 objects, which together with data taken from the literature covered 80 per cent of the sample. Here, we present spectroscopy obtained at large aperture telescopes of a further 17 objects (plus four additional targets), which completes the sample coverage. For 12 objects we are able to determine the redshift (0.07 < z < 1.6), while for the others we set a lower limit on it, based on either the robust detection of intervening absorption systems or on an estimation derived from the absence of spectral signatures of the host galaxy. With these new data we expand and reinforce the main results of our previous papers, namely the fact that in terms of their broad-band properties our sources appear to be indistinguishable from the rest of the blazar population and the relatively large (>34 per cent and possibly as high as 80 per cent) fraction of masquerading BL Lac objects, for which the low equivalent width of the emission lines is due to the brightness of the boosted continuum, rather than being an intrinsic property, in our sample.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototype for Unclassified Algorithm

Continuing previous efforts to investigate and develop the Unclassified Radioisotope Algorithm, the goal of the FY19-FY20 effort was to develop a prototype detector system which uses the algorithm to confirm warhead attributes related to the presence of either weapons grade plutonium (WGPu) or highly enriched uranium (HEU). The final deliverable is a prototype attribute measurement system built with common, commercially available gamma radiation detector components, capable of confirming the presence of specific, complex radioactive sources of interest, without the collection and storage of gamma energy spectra. This is accomplished by processing each gamma pulse as it is received, applying weight values based on the energy and incrementing or decrementing scalar counters which can be compared with expected values to determine if the measured source is consistent with WGPu or HEU. This report documents the design of the prototype system as well as the development of the algorithm and performance testing results. While the previously conceptualized, simple algorithm resulted in a prohibitive amount of false positives, the goal for a simple attribute measurement system capable of verifying Ba-133 and Ra-226 (weapons grade plutonium and highly enriched uranium surrogate testing sources) at over 95% accuracy with sub 5% false positive rate was demonstrated.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Production-Ready CsPbBr3 Module Fabrication

The purpose of this SBIR was to work on evaluation, development, and testing of CsPbBr3 semiconductors for use in commercial gamma-ray detection. The overarching goal was to demonstrate the capability to fabricate functional detectors through resources available to H3D, Inc in pursuit of an alternative to CdZnTe for room-temperature semiconductor detectors. Throughout the project, CdZnTe crystals from Redlen were used as a control group to demonstrate whether the fabrication processes could produce reasonable results. The CdZnTe crystals were diced into roughly 6 mm x 6 mm x 4.5 mm pieces and electrodes were evaporated onto planar faces. In one case, pixels were patterned through a laser ablation method; in the other, a rudimentary pixel shadow-mask was fabricated, and the pixels were generated in the evaporation process. A 16 mm x 16 mm x 14 mm CsPbBr3 crystal was diced into four smaller crystals. These CsPbBr3 had electrodes applied in a similar way to the CdZnTe samples with a rudimentary mask used for pixels on the cathode. Tested CdZnTe pieces were found to generally function with reasonable, low-energy performance. CsPbBr3 crystals were found to be non-functional under forward bias with a large dark-current. A separate attempt, using reverse bias in a non-H3D, Inc test system, observed a dark current similar to previous observations, and some active pixels but no waveforms were observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy neutrino emission from magnetized jets of rapidly rotating protomagnetars

ABSTRACT Relativistic jets originating from protomagnetar central engines can lead to long duration gamma-ray bursts (GRBs) and are considered potential sources of ultra-high-energy cosmic rays and secondary neutrinos. We explore the propagation of such jets through a broad range of progenitors, from stars which have shed their envelopes to supergiants which have not. We use a semi-analytical spin-down model for the strongly magnetized and rapidly rotating protoneutron star (PNS) to investigate the role of central engine properties such as the surface dipole field strength, initial rotation period, and jet opening angle on the interactions and dynamical evolution of the jet-cocoon system. With this model, we determine the properties of the relativistic jet, the mildly relativistic cocoon, and the collimation shock in terms of system parameters such as the time-dependent jet luminosity, injection angle, and density profile of the stellar medium. We also analyse the criteria for a successful jet breakout, the maximum energy that can be deposited into the cocoon by the relativistic jet, and structural stability of the magnetized outflow relative to local instabilities. Lastly, we compute the high-energy neutrino emission as these magnetized outflows burrow through their progenitors. Precursor neutrinos from successful GRB jets are unlikely to be detected by IceCube, which is consistent with the results of previous works. On the other hand, we find that high-energy neutrinos may be produced for extended progenitors like blue and red supergiants, and we estimate the detectability of neutrinos with next generation detectors such as IceCube-Gen2.

Astronomy & Astrophysics↗

Jetted and Turbulent Stellar Deaths: New LVK-detectable Gravitational-wave Sources

Upcoming LIGO–Virgo–KAGRA (LVK) observing runs are expected to detect a variety of inspiralling gravitational-wave (GW) events that come from black hole and neutron star binary mergers. Detection of noninspiral GW sources is also anticipated. We report the discovery of a new class of noninspiral GW sources—the end states of massive stars—that can produce the brightest simulated stochastic GW burst signal in the LVK bands known to date, and could be detectable in LVK run A+. Some dying massive stars launch bipolar relativistic jets, which inflate a turbulent energetic bubble—cocoon—inside of the star. We simulate such a system using state-of-the-art 3D general relativistic magnetohydrodynamic simulations and show that these cocoons emit quasi-isotropic GW emission in the LVK band, ~10–100 Hz, over a characteristic jet activity timescale ~10–100 s. Our first-principles simulations show that jets exhibit a wobbling behavior, in which case cocoon-powered GWs might be detected already in LVK run A+, but it is more likely that these GWs will be detected by the third-generation GW detectors with an estimated rate of ~10 events yr –1 . The detection rate drops to ~1% of that value if all jets were to feature a traditional axisymmetric structure instead of a wobble. Accompanied by electromagnetic emission from the energetic core-collapse supernova and the cocoon, we predict that collapsars are powerful multimessenger events.

79 ASTRONOMY AND ASTROPHYSICS↗

Alpha Spectrometry Results for Groundwater Samples Collected in Northern Iraq and a Summary of the Environmental Setting of the Adaya Burial Site

The Radiation Protection Center (RPC) of the Iraqi Ministry of Environment continues to evaluate the potential health impacts associated with the Adaya Burial Site, which is located 33 kilometers (20.5 miles) southwest of Mosul. This report documents the radiological analyses of 16 groundwater samples collected from wells located in the vicinity of the Adaya Burial Site and at other sites in northern Iraq. The Adaya Burial Site is a high-risk dump site because a large volume of radioactive material and contaminated soil is located on an unsecure hillside above the village of Tall ar Ragrag. The uranium activities for the 16 water samples in northern Iraq are considered to be naturally occurring and do not indicate artificial (man-made) contamination. With one exception, the alpha spectrometry results for the 16 wells that were sampled in 2019 indicate that the water quality concerning the three uranium isotopes (Uranium-233/234, Uranium-235/236, and Uranium-238) was acceptable for potable purposes (drinking and cooking). However, Well 7 in Mosul had a Uranium-233/234 activity concentration that slightly exceeded the World Health Organization guidance level. Eight of the 16 wells are located in the villages of Tall ar Ragrag and Adaya and had naturally occurring uranium concentrations. Wells in the villages of Tall ar Ragrag and Adaya are located near the Adaya Burial Site and should be sampled on an annual schedule. The list of groundwater analytes should include metals, total uranium, isotopic uranium, gross alpha/beta, gamma spectroscopy, organic compounds, and standard water quality parameters. Our current understanding of the hydrogeologic setting in the vicinity of the Adaya Burial Site is solely based on villager's domestic wells, topographic maps, and satellite imagery. To better understand the hydrogeologic setting, a Groundwater Monitoring Program needs to be developed and should include the installation of twelve groundwater monitoring wells in the vicinity of Tall ar Ragrag and the Adaya Burial Site. Characterization of the limestone aquifer and overlying alluvium is needed. RPC should continue to support health assessments for the villagers in Tall ar Ragrag and Adaya. Collecting samples for surface water (storm water), airborne dust, vegetation, and washway sediment should be conducted on a routine basis. Human access to the Adaya Burial Site needs to be strictly limited. Livestock access on or near the burial site needs to be eliminated. The surface-water exposure pathway is likely a greater threat than the groundwater exposure pathway. Installation of a surface-water diversion or collection system is recommended in order to reduce the potential for humans and livestock to come in contact with contaminated water and sediment. To reduce exposure to villagers, groundwater treatment should be considered if elevated uranium or other contaminants are detected in drinking water. Installing water-treatment systems would likely be quicker to accomplish than remediation and excavation of the Adaya Burial Site. The known potential for human exposure to uranium and metals (such as arsenic, chromium, selenium, and strontium) at the Adaya Burial Site is serious. Additional characterization , mitigation, and remediation efforts should be given a high priority.

54 ENVIRONMENTAL SCIENCES↗

Rapid Sample Insertion/Extraction Systems for Gamma Irradiation

The Rapid Sample Insertion/Extraction System for Gamma Irradiation, otherwise known as the "rabbit" system, was a four-week long project which included many different aspects; from coding an Arduino to building PVC piping to 3-D printing the "rabbit" capsules. The "rabbit" system is a system of PVC piping that allows a quick and efficient transfer of materials into/out of one of the irradiation chambers in the Gamma Irradiation Facility (GIF) with the use of a 3-D printed "rabbit." This "rabbit" encapsulates material to be irradiated and carries it from a position outside of the irradiation chamber to the basket inside of the chamber. The main purpose of this system is to save time and provide more exact data without any delays that normally occur when a person has to enter the chamber, retrieve data, and then analyze the data. This system should take measurements and retrieve the data instantaneously. The way in which the "rabbit" is sent through the PVC piping is with an advanced bi-directional, high-throughput pneumatic system, or a shop vacuum cleaner. When the vacuum is set to blow or suck then the "rabbit" will be pulled through the PVC piping to its intended destination and will hit sensors along the sides of the tubing when it reaches the end of the piping. These sensors tell the Arduino that the "rabbit" is finished moving throughout the tubing and stops a timer. Another timer is used to see how long the "rabbit" is being irradiated so when the "rabbit" reaches the sensors in the basket in the irradiation chamber another timer is started and it ends when the sensors no longer detect the "rabbit," which means that it has begun its journey back to the starting point.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Search for PeV Gamma-Ray Emission from the Southern Hemisphere with 5 Yr of Data from the IceCube Observatory

The measurement of diffuse PeV gamma-ray emission from the Galactic plane would provide information about the energy spectrum and propagation of Galactic cosmic rays, and the detection of a pointlike source of PeV gamma-rays would be strong evidence for a Galactic source capable of accelerating cosmic rays up to at least a few PeV. This paper presents several unbinned maximum-likelihood searches for PeV gamma-rays in the Southern Hemisphere using 5 yr of data from the IceTop air shower surface detector and the in-ice array of the IceCube Observatory. The combination of both detectors takes advantage of the low muon content and deep shower maximum of gamma-ray air showers and provides excellent sensitivity to gamma-rays between ~0.6 and 100 PeV. Our measurements of pointlike and diffuse Galactic emission of PeV gamma-rays are consistent with the background, so we constrain the angle-integrated diffuse gamma-ray flux from the Galactic plane at 2 PeV to 2.61 × 10 -19 cm -2 s -1 TeV -1 at 90% confidence, assuming an E -3 spectrum, and we estimate 90% upper limits on pointlike emission at 2 PeV between 10 -21 and 10 -20 cm -2 s -1 TeV -1 for an E -2 spectrum, depending on decl. Furthermore, we exclude unbroken power-law emission up to 2 PeV for several TeV gamma-ray sources observed by the High Energy Spectroscopic System and calculate upper limits on the energy cutoffs of these sources at 90% confidence. We also find no PeV gamma-rays correlated with neutrinos from IceCube's high-energy starting event sample. Lastly, these are currently the strongest constraints on PeV gamma-ray emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Black Hole to Photosphere: 3D GRMHD Simulations of Collapsars Reveal Wobbling and Hybrid Composition Jets

Long-duration γ-ray bursts (GRBs) accompany the collapse of massive stars and carry information about the central engine. However, no 3D models have been able to follow these jets from their birth via black hole (BH) to the photosphere. We present the first such 3D general-relativity magnetohydrodynamic simulations, which span over six orders of magnitude in space and time. The collapsing stellar envelope forms an accretion disk, which drags inwardly the magnetic flux that accumulates around the BH, becomes dynamically important, and launches bipolar jets. The jets reach the photosphere at ~10 12 cm with an opening angle θ j ~ 6° and a Lorentz factor Γ j ≲ 30, unbinding ≳90% of the star. We find that (i) the disk–jet system spontaneously develops misalignment relative to the BH rotational axis. As a result, the jet wobbles with an angle θ t ~ 12°, which can naturally explain quiescent times in GRB lightcurves. The effective opening angle for detection θ j + θ t suggests that the intrinsic GRB rate is lower by an order of magnitude than standard estimates. This suggests that successful GRBs are rarer than currently thought and emerge in only ~0.1% of supernovae Ib/c, implying that jets are either not launched or choked inside most supernova Ib/c progenitors. (ii) The magnetic energy in the jet decreases due to mixing with the star, resulting in jets with a hybrid composition of magnetic and thermal components at the photosphere, where ~10% of the gas maintains magnetization σ ≳ 0.1. This indicates that both a photospheric component and reconnection may play a role in the prompt emission.