At least 217 records · Page 12

Nuclear Material Accounting and Control (NMAC) for a Commercial Fuel Debundling Facility in the United States

The concept of fuel debundling proposes that all non-fuel components of a fuel assembly be removed prior to beginning the recycling process. It was introduced to reduce the quantity of and cost of disposing high level radioactive waste during recycling in the United States. However, nuclear material accountancy and control programs could also benefit from fuel debundling due to a reduction in self-shielding material for individual fuel rods compared to a fuel assembly. Current NRC regulations and guidance point to an independent fuel debundling facility with a material-possession-only license as the best option for implementing this concept into a used fuel recycling scheme in the United States. This allows the facility to comply only with simple NMAC requirements under Subpart B of 10 CFR Part 74 without the need to submit an NMAC plan to the NRC, exempting it from more tedious and complex NMAC requirements. However, a recycling facility may desire a Pu mass estimate from measurements of each individual fuel rod to improve accountancy into the dissolver. Many technologies and methodologies were considered for performing NMAC in an independent fuel debundling facility in the United States. Few were able to meet anticipated throughput demands of up to 3,300 rods/day and achieve measurement uncertainties suitable for input accountancy for a recycling facility. The best option was a combination of passive gamma-ray spectroscopy and neutron coincidence counting to meet all requirements for the proposed Fuel Debundling Detector (FUDD). Follow-on work will include a full uncertainty analysis to inform what assumptions can be made to meet input accountancy objectives before beginning experimental activities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Delayed Neutron Temporal Signatures for Uranium Enrichment Measurement NA-241 SGTech (Final Report)

Nondestructive determination of uranium enrichment is a core capability for nuclear material accounting and control (NMAC) and safeguards verification measurements; however, traditional gamma spectroscopy-based techniques for enrichment measurement rely on significant assumptions of material composition and geometry, precluding their use in scenarios where a heterogeneous spatial distribution of enrichments is encountered. As an alternative, we are developing a technique to use delayed neutron temporal signatures for the measurement of uranium enrichment. Each uranium isotope has unique delayed neutron group yields, resulting in a unique delayed neutron decay time profile which can be analyzed to determine enrichment without the need for calibration sources. As part of this effort, we performed a series of measurement campaigns in which we used an active well coincidence counter (AWCC) retrofitted with commercial D-D and D-T generators to evaluate the operational characteristics of this method in response to a set of uranium enrichment and mass standards, as well as representative diversion scenarios in which either “concealed” enriched uranium is shielded by depleted uranium or declared enriched uranium is “hollowed out” and replaced with a central region of depleted uranium. A standard operating procedure and best practices were compiled to facilitate the use of delayed neutron-based enrichment measurements for international safeguards inspections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum enabled precision measurements of the 229Th nuclear isomer transition (final report)

The existence of the nuclear isomer transition in thorium-229 was first inferred from keV lines in the gamma spectrum of uranium-233 decay more than 40 years ago. Over the years, the value of the transition energy has been refined with indirect measurements using nuclear physics techniques, and the current evidence points to transition energy in the laser-accessible vacuum ultra-violet region of the spectrum. At the start of this project, the two best measurements of the transition energy were 7.8±0.5 eV and 8.28±0.17 eV from high precision gamma ray spectroscopy and kinetic energy of internal conversion electrons, respectively. This project aimed to reduce the uncertainty in the transition energy to 10 meV using direct calorimetric measurements of the decay energy with superconducting nanowire single photon detectors (SNSPDs). Specifically, the method that was pursued was to generate thorium-229 in the excited isomer state by the alpha decay of uranium-233, embed the excited state thorium into an SNSPD, then detect the energy released when the isomer deexcites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assembly and Initial Testing of the Gamma-Ray Emission Tomography Assessment Prototype for Irradiated Fuel

The following report documents the final development, assembly, and initial testing of the gamma-ray emission tomography assessment system (GRETA-1) for post-irradiation examination of irradiated fuel. It includes descriptions of the system components, including the high-purity germanium gamma-ray detector, the surrounding shield and collimator, the sample scanning hardware, and the control and collection software package. A series of MCNP6 simulations were performed that modeled a fuel rod scan to test image reconstruction algorithms with a complex and understood source distribution. A bench-top scan of isotopic check sources was also performed and analyzed using standard image reconstruction algorithms. The system is currently awaiting deployment at Idaho National Laboratory’s Hot Fuel Examination Facility.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Accelerated 133 Xe Quantification in Samples Containing Significant 133 mXe

The quantification of 133 Xe in the presence of its mother radionuclide 133 mXe requires the full quantification of both to perform the ingrowth correction for 133 Xe. Due to the nature of both of these radionuclides, the 133 mXe requires significantly more time to quantify by High Purity Germanium (HPGe) detectors due to lower production yields, lower gamma emission probabilities, and lower detection efficiencies. This work shows that 133 Xe and 133 mXe quantification can be accelerated by measuring the 133m:133 activity ratio for a large batch of material and applying this activity ratio to assays of lower activity subsamples of the same batch of material. Included in this report are derivations of the required decay correction equations, and experiments using actual samples to validate the performance of these equations. A detector calibration method is also shown that leverages this method as an alternative to existing calibration methods for 133 mXe quantification.

133mXe↗

Variance Preserving Spectral Subsampling

Generating statistically faithful short-duration gamma-ray spectra from a single long measurement is essential in nuclear safeguards, supporting tasks such as algorithm development and machine-learning applications, especially when list-mode data are unavailable. Existing subsampling methods often distort the statistical characteristics of genuine short-duration measurements, leading to biased or unreliable analytical outcomes and thereby undermining downstream tasks. In this work, we compare five subsampling approaches using a benchmark set of 156 genuine replicate spectra collected with a high-purity germanium detector. We evaluate each method with respect to run-to-run variance, channel-to-channel variance, and preservation of total counts (losslessness). Across a wide range of subsampling ratios, only binomial subsampling without replacement consistently reproduces the statistical properties of genuine short-duration spectra, maintaining proper dispersion even in sparse spectral regions and perfectly preserving total counts. These results provide a mathematically principled and practically validated framework for generating synthetically shortened spectra when true short-duration measurements are unavailable.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

Spectroscopy of the Hamburg Meteorite, Michigan H4

Spectroscopic studies of the Hamburg (Michigan H4) meteorite using visible–near-infrared (VNIR), mid-infrared (MIR), Raman, and Mössbauer data reproduce the results of more conventional laboratory measurements of petrology and geochemistry. This combination provides general information on the mineral modes of silicates, although spectroscopy was performed on different splits of this meteorite, and varying results may be explained by heterogeneity that is typical of ordinary chondrites. Raman also detects small features assigned to first-order D and G carbon bands, while Mössbauer data show the presence of Fe oxides and carbides. The electron microprobe (EMPA) composition of olivine in this meteorite is accurately measured to be Fo 81.3 , while MIR and Raman closely agree with Fo 80 and Fo 82 , respectively, and Mössbauer, at Fo 60 − Fo 70 , is in the ballpark. Similarly, P. R. Heck et al. report pyroxenes with compositions of Fs 16 Wo 1 , while Raman suggests a somewhat similar composition of Fs 28 Wo 0 . Both VNIR and MIR detect the presence of small amounts of feldspar, while EMPA identifies its composition as An 14 Ab 8 Or 5 . VNIR data were matched to spectral libraries of meteorite and asteroid data and shown to closely match other L and H meteorites. The best spectral matches to the Michigan H4 meteorite are to asteroid classes L/H/LL/URE, EH/EL/AUB, and CO/CV from M. D. Dyar et al.; objects in this group are intermediate in semimajor axis lengths for their orbits. The results highlight the strengths and weaknesses of each technique and show their collective strength when applied together to a single meteorite sample.

58 GEOSCIENCES↗

Cumulative short-lived photofission product yields for nuclear forensic application

Experiments have long been carried out with linear accelerator (linac) produced bremsstrahlung X-rays to study high-energy photon-induced fission, known as “photofission”. One benefit of photofission, when compared with neutron-induced fission, is the ability to investigate fundamental physics of fission at excitation energies lower than what is possible with neutrons [1]. Absorption of an incident neutron results in a compound nucleus with an excitation energy at least equal to the neutron binding energy; thus, the lowest energy region of the fission barrier cannot be studied. Fission product yield distributions are dependent on the incident particle energy and the target nucleus mass. They are generally represented by a double-humped curve, with low and high mass “peaks” and an intermediate mass “valley”. As incident particle energy increases, the excitation energy of the nucleus increases, thereby increasing the overall yield of isotopes in the valley with respect to the two maxima or peaks of the fission product curve [3]. Photofission is most probable for incident photons around 14 MeV due to the giant dipole resonance. Induced photofission around this energy results in a fission product yield distribution that resembles 14 MeV DT neutron fission more than thermal or fast (500 keV) neutron fission. In post-detonation nuclear forensics, the peak-to-valley ratio of the fission product yield curve could be used for characterizing device type by providing an indication of the neutron energy spectrum that had induced fission (e.g., 500 keV vs. 14 MeV). The goal of this work is to improve nuclear data for isotopes of interest in nuclear forensics and special nuclear material (SNM) detection, specifically the fission product yield data via photofission experiments for the isotopes of 238U and 232Th. Photofission has been proposed as a less costly and more flexible production method for the valley isotopes that are representative of DT neutron fission product yield distributions, which would benefit nuclear forensics exercises in testing for analysis techniques. Natural uranium and thorium targets were irradiated with bremsstrahlung photons (nominal endpoint energies of 8, 14, and 20 MeV), generated via impingement of high-energy electrons on a tungsten electron-to-photon radiator. Gamma-ray spectroscopy was used to observe and identify the decay of the resulting fission products. The photofission yields of 102 fission products were measured for the set of the 238U and 232Th targets at the three bremsstrahlung X-ray endpoint energies 8, 14, and 20 MeV. These fragments included masses ranging from A=84 to A=144, with half-lives as short as 1.07 seconds.

07 ISOTOPE AND RADIATION SOURCES↗

Correlated Signal Analysis for Nuclear Emergency Response

In the context of nuclear emergency response (NER) scenarios, the critical task is to quickly identify a "black box" as a potential threat, as failing to do so could have catastrophic consequences. Techniques for passive assay of a “black box” typically include gamma-ray spectroscopy and neutron coincidence/multiplicity counting. However, there are significant challenges associated with these type of measurements. First, the presence of intervening materials can obstruct the detection of relevant signatures. Second, the presence of strong non-fission neutron sources, like (α, n) emitters, can add uncertainties to the neutron multiplicity analysis. In our LDRD-MFR Phase II work, a portable neutron spectrometer, called the Compact Fast Neutron Spectrometer (CFNS), was developed for NER applications. The CFNS system leverages information-rich neutron energy spectra to derive actionable information. This work investigates the use of correlated signals in the CFNS from special nuclear material (SNM) to characterize physical properties, such as intervening shielding material and fission to non-fission neutron contributions. In this report, the Phase II results from bulk SNM measurements at the National Criticality Experiments Research Center (NCERC) are briefly discussed along with the motivation for this work. Afterwards, simulations using the MCNPX-PoliMi transport code are discussed, which were used to expand our correlated signal study. Signal triggered analysis for neutron multiplicity extraction will also be discussed. Lastly, the use neutron-photon correlations for intervening material identification are shown, along with the use of correlated neutron energy spectra for α-ratio extraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced Radionuclide Gamma spectrOmeter-2 (ARGO-2) for Low-level Radionuclide Measurements

A low-level multidimensional gamma spectrometer was recently installed at Pacific Northwest National Laboratory, USA. The spectrometer utilizes a dual-detector design and advanced detection techniques, demonstrating superior detection efficiency/sensitivity. This work details integral components of the system, including the dual-detector design, its shielding, and cosmic veto panels for background reduction. Results from system’s operation in singles and coincidence mode are highlighted.

ARGO, Coincidence measurements, Multidimensional g↗

Feedback on Forty-year Long Clean-up Operations of a Contaminated Soil for Environmental Purpose - 20026

One of the CEA facilities in France is the place of miscellaneous mapping and clean-up operations since the 1980's. The final purpose of the conducted work deals with the environmental remediation of the building. In France, the absence of a regulatory framework for the management of sites polluted by radioactive substances, especially as the lack of release thresholds, has led to develop different approaches of soil radiological characterization. The geostatistical approach is part of them. Preliminary investigations are an unavoidable step prior to clearance and remediation. First, historical analysis enables to define site perimeters to investigate as well as to precisely locate expected contaminated parts. For radioactive pollutants, the media (water, soil, air) and transfer routes participate in the definition of the investigation perimeter and thus also need to be identified through a geological study. At the same time, functional analysis leads to choose the best measurement means which could provide useful information when combined with visual inspection. An equipment well adapted to easy-to-measure radionuclides as gamma emitters, such as gamma probe or on-site gamma spectrometry, is usually selected as a non-destructive assay. Coupled with spatial positions, processed on-site radiological data can be mapped. Data processing consists in mapping and kriging before a geostatistical analysis in order to identify the zones of interest to be targeted. Selected zones are not only linked to high level count rates but also to low level ones so that a pollution-free reference is known in the area. This data processing also enables to categorize waste types according to their origin and contamination levels. An expected volume of different waste then follows as well as the waste characterization equipments. In-depth investigations, e.g. core drillings and samplings, naturally ensue to aim at remediation optimization through the assessment of environmental impact. After clean-up operations, non-destructive assays as well as destructive samplings enable to check the effective clearance. Following this methodology in the present remediation work, results of the first non-destructive assay campaign highlighted a long-lived transuranic radionuclides contamination in the concrete flagstone. Successive non-destructive assays were then performed in the defined zones of interest. Count rates measured with a surface probe were first mapped. The best localization of destructive assays, i.e. core drillings at a 1 meter depth, came from this surface mapping followed by a geostatistical analysis. The concrete flagstone was totally removed. Then, the depth of soil to remove under the flagstone was optimized from the results of radiological activities measured in core drillings samples. A new surface mapping was then drawn after this partial soil excavation. The sand and demolition rubble samples, homogeneously constituted from the flagstone fragments, were analyzed by gamma spectrometry. Meanwhile, waste drums and other containers were also measured by gamma spectrometry and passive neutron measurement devices. All these results have brought miscellaneous pieces of information. In this context, major issues appear in terms of physical constraints such as the premises tininess as well as of soil sampling techniques and in terms of measurement performances assessment and the representativeness of homogeneous samples. The choice of radiological soil and waste characterization devices is described in the light of enhanced performances by keeping in mind radiation protection requirements and a willing to always optimize waste categories (very low level waste) and volume. The improvement of the characterization methods appears through this forty-year long work while sharing the feedback of encountered difficulties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ISOCS-based Extended In Situ Gamma Spectrometry Services Tool SuperISOCS for Waste Measurements - 20275

Canberra's In Situ Object Counting System (ISOCS) is an established tool used for gamma spectrometry. It allows physical representation of complex geometries and mathematical calculation of the calibration function while avoiding the need for radioisotope standards. ISOCS provides a large range of templates to generate the geometry for most nuclear waste components in nuclear facilities. Nonetheless, there are some complex geometries where the accuracy attainable is limited by the conventional ISOCS templates. An ISOCS-based extended in-situ Gamma Spectrometry service tool has been developed, based on the so-called SuperISOCS (SISOCS) software. This tool was developed to generate the most complex geometries. The principle of geometry construction is based on the composition of 8 different primitive geometries. The primitive object is able to be cut and to change a part of an object. An object is able to overlap to another one to form a more complex object. These functions refine the modelled geometry compared to the real objects and decrease the measurement systematic error because they allow the mathematical model to represent the real-life geometry more faithfully through reducing the approximations and simplifications that need to be made The algorithm of SISOCS is the same as that of standard ISOCS. A set of calculations was done in comparison with MCNP efficiency calculation and SISOCS results. 80 different models were compared between SISOCS and MCNP, with added 30 cases compared between ISOCS and SISOCS. The average differences were less than 2%, for all energy's efficiency calculations. In this paper we illustrate the benefits that this new tool can provide, in terms of improved accuracy for complex realistic geometries, through simulation of some example scenarios. Furthermore, we demonstrate, through SISOCS modelling of the real object data test, the comparison between SISOCS to ISOCS calculations for the same geometry. This paper describes the added functions that are easily employed using SISOCS. Our results show the potential application and benefit of this technique for real waste assay projects and the way to integrate the tool into the waste assay systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Strategy of a Limited Number of Radioactive Waste Effluent Tanks in View of Decommissioning a Large Number of Tanks - 20286

In order to organize the D and D of the former effluent treatment facility at the CEA Cadarache Center (France), the key data to gather through the facility characterization are the following:: volumes and masses, liquid/solid distribution and specific activity. By studying the treatment processes and the history of the facility, families of tanks have been defined and a reference tank chosen for investigation in each family. The intrusive investigations (video, residue thickness, dose rate..), the gamma spectrometry measurements carried out on site on the residue samples and radiochemical results collected in laboratories, led us to conclude that there was a relative radiological homogeneity (for specific activity and Am-241/Cs-137 ratio) within each tank. The next step consisted in extrapolating the specific activity evaluated for the reference tanks, to the other tanks of each family by using data such as geometry, dose rate or the function of the tanks within the process. Thus, a cartography of the 130 tanks of the facility is available. Finally, the conclusions drawn from the radiological homogeneity of the tanks and their affiliation to homogeneous, well-identified tank clusters lead to a simple and efficient operational approach for the D and D of the 130 tanks of the facility. Indeed, because of the residue characteristics (homogeneous activity and strong differentiation of Cs/Am ratio), a sample collected when opening the tank, and measured on site by gamma spectrometry will allow us to validate the operational design and the emptying techniques defined during the D and D study phase thanks to the characterization of a limited number of reference tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Requalification and Declaration of High-alpha Cemented TRU-waste from the Late 70's and Early 80's - 20499

KTE and Siemens launched a project to qualify a series of 391 waste drums and 115 concrete containers produced from 1979 to 1984. The waste is characterized by a high content of long-lived alpha-nuclides (TRU-waste - Pu, U, Am in the range of 1 E+11-1 E+12 Bq/ drum. This high radionuclide inventory requires a special packaging according to the waste acceptance criteria (WAC) of the repository Konrad [1] despite the fact, that the waste was treated manually. The raw waste originally was delivered in nitric acid solution and was solidified using ordinary Portland cement. The existing documentation comprises analyses, transfer documentation for the nuclear fuel nuclides and waste treatment documentation yielding information, which waste was treated together in a batch. Additionally all drums were subjected to non-destructive gamma-spectrometry assay. A small number of 7 drums were opened and sampled to support the existing declaration. For the entire series the waste products were attributed to defined batches using the accountancy data supported by the analyses and the gamma-spectrometry. Each batch was produced from a homogeneous stock of waste solution and can therefore be declared and documented together. The declaration concept is based on the gamma spectrometry results performed on the entire drums, which were corrected and extended for the uncertainty of the analyses. The declaration concept is verified by the regulator and its independent expert. The state of the project is in the documentation of the solidification campaigns followed by the planning of the container configuration. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MEASUREMENT OF THE NEUTRON FLUENCE-RATES IN THE ADVANCED TEST REACTOR

The axial neutron fluence-rate distribution at the Advanced Test Reactor (ATR) is determined using a combination of pure nickel and cobalt-aluminium alloy dosimeter wires. Most irradiation programs at ATR need to know the fast neutron fluence-rate surrounding their experiment to correlate post-irradiation examination results with neutron dose. The activated dosimeter wires, which extend beyond the full fuelled region of the reactor core, are highly radioactive following the full cycle in ATR and must therefore be measured in the ATR canal. The system that is employed for these measurements is mechanical scanning mechanism is used to scan the activated wires across the face of a columnated shield and a NaI detector. This detector is not sufficiently calibrated to provide absolute activity measurements, therefore, the count-rate is recorded and normalized to the highest activity for that wire. Then, an approximately 3-mm long portion of the wire is removed from the highest activity region in the wire. The wires are then transferred, and an absolute activity measurement is made using a calibrated ionization chamber. These measurements are combined with corrections for decay, neutron energy spectrum, burnup, dosimeter composition, reactor power fluctuations, and reactor outages to determine the average axial neutron fluence-rate at various locations within ATR during the cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Internal-Gelation Production of Uranium Oxide Sol-Gel Particles for Forensic Applications

The purpose of this project was to develop and demonstrate a novel method for the production of uranium oxide microsphere particles with tunable chemical compositions via a sol-gel process using a 3D-printer setup. These particles can serve several purposes in research and development as a forensic training tool or as standard reference materials. A key component of the project was to demonstrate the ability to control physical and chemical parameters of the particles created. First, we demonstrated the ability to employ an internal gelation sol-gel process to create individual uranium oxide particles. The particles were successfully dispensed using a unique 3D-printing setup onto a substrate to react and then were collected and thermally processed. A series of temperatures for the annealing process was tested on individual samples to investigate the effect on the sol-gel chemical composition and physical integrity. Next, we demonstrated the ability to control matrix composition of the particles by separately incorporating fission product isotopes as well as Np-237 into the sol-gel solution. It was shown by gamma-ray spectroscopy that these matrix elements were successfully retained during the gelation process. We studied the retention of the elements across a series of annealing temperatures. Additionally, we demonstrated the ability to quantitatively control the isotopic composition of the particles by altering the U-237/U-238 ratio to a controlled value. Finally, X-ray diffraction analysis (XRD) was used to investigate the oxidation state of the sol-gel after annealing at different temperatures.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗