Search NASA⌕ Search

SEARCH · Search NASA

Results for “gradient boost machine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

207 records · Page 12

Operation and Optimization of Microwave-Heated Continuous-Flow Microfluidics

Microwave (MW) technology can be powerful for electrification and process intensification but limited fundamental understanding of scalability and design principles hinders its effective use. In this work, we build a continuous-flow microreactor inside a commercial single-mode MW applicator and the corresponding computational fluid dynamics model to simulate the temperature profile. The model is in good agreement with experiments for various microreactor dimensions and operating conditions. The model indicates that MW heating is greatly influenced by reactor geometry as well as the operating parameters. We observe a strong correlation between parameters and develop a gradient boost regression tree model to predict the outlet temperature accurately. This model is then applied to optimize the dimensions and operating conditions to maximize the outlet temperature and energy efficiency, resulting in a Pareto optimal. We demonstrate computationally and experimentally that it is possible to surpass the Pareto optimal and achieve an energy efficiency of ~90% or greater at temperatures relevant for liquid-phase chemistry via salting of the solvent. The present methodology can be applied to other complex MW reactors. Lastly, the combined numerical and experimental approach provides insights into and a framework for scale-up and optimization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine-learning and first-principles investigation of lightweight medium-entropy alloys for hydrogen-storage applications

The transition to a low-carbon economy demands efficient and sustainable energy-storage solutions, with hydrogen emerging as a promising clean-energy carrier and with metal hydrides recognized for their hydrogen-storage capacity. Here, we leverage machine learning (ML) to predict hydrogen-to-metal (H/M) ratios and solution energy by incorporating thermodynamic parameters and local lattice distortion (LLD) as key features. Our best-performing ML model provides improvements to H/M ratios and solution energies over a broad class of medium-entripy alloys (easily extendable to multi-principal-element alloys), such as Ti–Nb-X (X = Mo, Cr, Hf, Ta, V, Zr) and Co–Ni-X (X = Al, Mg, V). Ti–Nb–Mo alloys reveal compositional effects in H-storage behavior, in particular Ti, Nb, and V enhance H-storage capacity, while Mo reduces H/M and hydrogen weight percent by 40–50 %. We attributed results in molybdenum-rich alloys to slow hydrogen kinetics, as validated by our pressure-composition-temperature (PCT) isotherm experiments on pure Ti and Ti 5 Mo 95 alloys. Density functional theory (DFT) and molecular dynamics (MD) simulations also confirm that Ti and Nb promote H diffusion, whereas Mo hinders it, highlighting the interplay between electronic structure, lattice distortions, and hydrogen uptake. Notably, our Gradient Boosting Regression model identifies LLD as a critical factor in H/M predictions. Here, to aid material selection, we present two periodic tables illustrating elemental effects on (a) H 2 wt% and (b) solution energy, derived from ML, and provide a reference for identifying alloying elements that enhance hydrogen solubility and storage.

08 HYDROGEN↗

Machine Learning Predicts the Timing and Shear Stress Evolution of Lab Earthquakes Using Active Seismic Monitoring of Fault Zone Processes

Abstract Machine learning (ML) techniques have become increasingly important in seismology and earthquake science. Lab‐based studies have used acoustic emission data to predict time‐to‐failure and stress state, and in a few cases, the same approach has been used for field data. However, the underlying physical mechanisms that allow lab earthquake prediction and seismic forecasting remain poorly resolved. Here, we address this knowledge gap by coupling active‐source seismic data, which probe asperity‐scale processes, with ML methods. We show that elastic waves passing through the lab fault zone contain information that can predict the full spectrum of labquakes from slow slip instabilities to highly aperiodic events. The ML methods utilize systematic changes in P‐wave amplitude and velocity to accurately predict the timing and shear stress during labquakes. The ML predictions improve in accuracy closer to fault failure, demonstrating that the predictive power of the ultrasonic signals improves as the fault approaches failure. Our results demonstrate that the relationship between the ultrasonic parameters and fault slip rate, and in turn, the systematically evolving real area of contact and asperity stiffness allow the gradient boosting algorithm to “learn” about the state of the fault and its proximity to failure. Broadly, our results demonstrate the utility of physics‐informed ML in forecasting the imminence of fault slip at the laboratory scale, which may have important implications for earthquake mechanics in nature.

58 GEOSCIENCES↗

SU-E-T-305: Dosimetric Comparison of Cyberknife Versus Linac Based VMAT Stereotactic Treatment Planning for Localised Prostate Cancer

Purpose: The purpose of this study was to compare dosimetric indices of Cyberknife versus Linac for localised prostate cancer Methods: In this study, twenty patients were taken from Cyberknife Multiplan TPS v 4.6.0. All these patients underwent hypo fractionated boost treatment for localised prostate cancer in Cyberknife with the prescription dose of 18Gy in 3 fractions. For each patient VMAT stereotactic plans were generated in Monaco TPS v 5.0 using Elekta beam modulator MLC machine for 6MV photon beam. The plans quality were evaluated by comparing dosimetry indices such that D95, D90, D5 for target volume and V100, V80, V50, V30 for critical organs. The p values were calculated for target and OAR to ascertain the significant differences. Results: For each case, D95 of target coverage was achieved with 100% prescription dose with p value of 0.9998. The p value for D90, D5 and V100 for linac and Cyberknife plans was 0.9938, 0.9918 and 0.9838 respectively. For rectum, rectum-PTV and bladder doses were significantly less in Cyberknife compared to linac plans. For rectum, rectum-PTV and bladder at V100 the p value is 0.2402, 0.002, and 0.1615 respectively. Other indices V80, V50 and V30 were comparable in both plans. Conclusion: This study demonstrated that both linac and Cyberknife plans were shown adequate target coverage, while in Cyberknife the treatment time is longer and more MUs to be delivered. However, better conformity, lesser doses to the critical organs and dose gradient outside target for localised prostate treatment were achieved in Cyberknife plans due to multiple non coplanar beam arrangements.

60 APPLIED LIFE SCIENCES↗

Accelerating iterative ptychography with an integrated neural network

Electron ptychography is a powerful and versatile tool for high-resolution and dose-efficient imaging. Iterative reconstruction algorithms are powerful but also computationally expensive due to their relative complexity and the many hyperparameters that must be optimised. Gradient descent-based iterative ptychography is a popular method, but it may converge slowly when reconstructing low spatial frequencies. Here, in this work, we present a method for accelerating a gradient descent-based iterative reconstruction algorithm by training a neural network (NN) that is applied in the reconstruction loop. The NN works in Fourier space and selectively boosts low spatial frequencies, thus enabling faster convergence in a manner similar to accelerated gradient descent algorithms. We discuss the difficulties that arise when incorporating a NN into an iterative reconstruction algorithm and show how they can be overcome with iterative training. We apply our method to simulated and experimental data of gold nanoparticles on amorphous carbon and show that we can significantly speed up ptychographic reconstruction of the nanoparticles.

4DSTEM↗

The Global LAnd Surface Satellite (GLASS) evapotranspiration product Version 5.0: Algorithm development and preliminary validation

An accurate estimation of spatially and temporally continuous global terrestrial evapotranspiration (ET) is essential in the assessment of surface energy, water and carbon cycles. The Global LAnd Surface Satellite (GLASS) ET product Version 4.0 (v4.0) based on the Bayesian model averaging (BMA) method was generated to estimate global terrestrial ET. However, certain uncertainty for the GLASS ET product v4.0 limits its application. In this study, we introduced the deep neural networks (DNN) merging framework to improve terrestrial ET estimation for GLASS ET product Version 5.0 (v5.0) generation by integrating five satellite-derived ET products [Moderate Resolution Imaging Spectroradiometer (MODIS) ET product (MOD16), Shuttleworth–Wallace dual-source ET product (SW), Priestley–Taylor-based ET product (PT-JPL), modified satellite-based Priestley–Taylor ET product (MS-PT) and simple hybrid ET product (SIM)]. We compared the performance of DNN method against other merging methods, including GLASS ET algorithm v4.0 (BMA), the gradient boosting regression tree (GBRT) method and the random forest (RF) method, based on 195 global eddy covariance (EC) flux towers covering observations from 2000 through 2015. Validations indicated that the DNN had the highest accuracy among four merging methods across different land cover types, yielding the highest average determination coefficients (R 2 , 0.62), root-mean-squared-error (RMSE, 24.1 W/m 2 ) and Kling–Gupta efficiency (KGE, 0.77) with a of 99% confidence interval. Compared with GLASS ET algorithm v4.0, the DNN improved on the R 2 by approximately 7% (p < 0.01) and the KGE by 10%. Based on the DNN, we then generated 8-day GLASS ET product v5.0 globally with a 1 km spatial resolution from 2001 to 2015 driven by GLASS vegetation and surface net radiation (R n ) datasets and Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA2) datasets. Finally, this global terrestrial ET product provides a valuable dataset for monitoring regional and global water resources and environmental changes.

54 ENVIRONMENTAL SCIENCES↗

Large-Scale Groundwater Monitoring in Brazil Assisted With Satellite-Based Artificial Intelligence Techniques

Here, we develop and test an artificial intelligence (AI)-based approach to monitor major Brazilian aquifers. The approach combines Gravity Recovery and Climate Experiment (GRACE) data and ground-based hydrogeological measurements from Brazil’s Integrated Groundwater Monitoring Network at hundreds of wells distributed in twelve aquifers across the country. We tested model ensembles based on three AI approaches: Extreme Gradient Boost, Light Gradient Boosting Model and CatBoost, followed by a Linear Regression (LR) step. The approach is further boosted with wavelet and seasonal decomposition processes applied to GRACE data. To determine the AI-based model’s sensitivity to data availability, we propose four experiments combining hydrogeological measurements from different aquifers. Groundwater storage estimates from the Global Land Data Assimilation System (GLDAS) are used as benchmark. A sensitivity analysis shows that the LR-based model ensemble is the best suited and to reproduce groundwater storage change in all studied Brazilian aquifers. Results show that the proposed approach outperforms GLDAS in all experiments, with an RMSE value of 2.68cm for the experiment that covers all monitored wells in Brazil. GLDAS resulted in RMSE=6.76cm. Using our AI model outputs, we quantified the groundwater storage change of two major aquifers, Urucuia and Bauru-Caiuá, over the past two decades: -31km 3 and -6km 3 , respectively. Water loss is driven by a prolonged drought across most of the country and intensification of groundwater pumping for irrigation. This study demonstrates that combining satellite data and AI can be a cost-effective alternative to monitor poorly equipped aquifers at the continental scale, with possible global replicability.

GRACE↗

A Novel Machine Learning Method for Surface PM2.5 Estimations from Geostationary Satellites

Particulate matter (PM) with a diameter of less or equal to 2.5 μm, known as PM , affects human health as it penetrates the respiratory system. The Environmental Protection Agency (EPA) measures the atmospheric concentration of PM using air quality monitors stationed throughout the Continental United States (CONUS). Such measurements are points on a spatial domain and therefore, might not be representative of the air quality at nearby areas considering that the composition of the atmosphere is highly variable from place to place. Satellite based AOD permits a spatially uniform means of estimating PM and new geostationary satellites provide high temporal and spatial resolution estimation of AOD. However, the concentration of PM is non-linearly dependent on other atmospheric parameters that include relative humidity, temperature, and height of the planetary boundary layer. This information may be estimated at similar spatial and temporal resolutions as AOD from numerical modeling such as from the National Oceanic and Atmospheric Administration’s (NOAA) High Resolution Rapid Refresh (HRRR) model which resolves near real-time atmospheric conditions over the CONUS. The estimation of PM concentration is a multi-parametric problem that considers the effect of temporal dependencies among the different parameters. Deep learning approaches are appropriate for such complex estimation problems as they intrinsically capture relations among multiple non-linear parameters. This study compares deep-learning methods to traditional regression analysis to demonstrate the capabilities of these methods in predicting PM2.5 concentrations. Additionally, a novel ensemble learning approach is employed to identify scientific processes that could further improve the estimation of PM concentration. Utilizing Long Short-Term Memory (LSTM) neural networks, which are suitable for multivariate time series estimation problems as they are capable of learning long-term dependencies, individual models are created for each EPA station and trained on the aforementioned dataset collocated over each station. Individual station models are merged if the model's performance is improved by reducing the root mean squared error (RMSE) metric. This ensemble training method ultimately reduces the RMSE value. Evaluation of these results provide insights into physical processes and related observable parameters that may contribute to PM concentrations. Identified parameters evaluated to be statistically different between the merged and unmerged models are expected to improve overall performance. These new parameters are then utilized for reevaluation of the deep learning methods with an extreme gradient boosting model with an RMSE of 5.5 providing the best results.

George Priftis↗

Pharmacoepidemiology, Machine Learning and COVID-19: An intent-to-treat analysis of hydroxychloroquine, with or without azithromycin, and COVID-19 outcomes amongst hospitalized US Veterans

Hydroxychloroquine (HCQ) was proposed as an early therapy for coronavirus disease 2019 (COVID-19) after in vitro studies indicated possible benefit. Previous in vivo observational studies have presented conflicting results, though recent randomized clinical trials have reported no benefit from HCQ amongst hospitalized COVID-19 patients. In this work, we examined the effects of HCQ alone, and in combination with azithromycin, in a hospitalized COVID-19 positive, United States (US) Veteran population using a propensity score adjusted survival analysis with imputation of missing data. From March 1, 2020 through April 30, 2020, 64,055 US Veterans were tested for COVID-19 based on Veteran Affairs Healthcare Administration electronic health record data. Of the 7,193 positive cases, 2,809 were hospitalized, and 657 individuals were prescribed HCQ within the first 48-hours of hospitalization for the treatment of COVID-19. There was no apparent benefit associated with HCQ receipt, alone or in combination with azithromycin, and an increased risk of intubation when used in combination with azithromycin [Hazard Ratio (95% Confidence Interval): 1.55 (1.07, 2.24)]. In conclusion, we assessed the effectiveness of HCQ with or without azithromycin in treating patients hospitalized with COVID-19 using a national sample of the US Veteran population. Using rigorous study design and analytic methods to reduce confounding and bias, we found no evidence of a survival benefit from the administration of HCQ.

60 APPLIED LIFE SCIENCES↗