Search NASA⌕ Search

SEARCH · Search NASA

Results for “graphite electrodes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Monitoring of Ionic Silver Biocide with Capacitively-Coupled Contactless Conductivity Detection (C4D)

Monitoring of biocide dosing in spacecraft potable water systems is desirable to ensure dosing system operation and resultant microbial control. Electrolytic conductivity is linearly related to the concentration ionic silver (Ag+, the baseline biocide for future NASA missions) chemically dosed into highly purified water, and could serve as a proxy measurement. Traditional conductivity cells rely on immersed metal or graphite electrodes, which may potentially be subject to significant current-induced or auto-galvanic deposition of Ag+. Furthermore, oxide fouling may potentially induce measurement errors. Capacitively-coupled contactless conductivity detection (C4D) is a promising alternative. C4D uses electrodes placed outside an inert, non-conductive flow path, potentially mitigating such problems. We identified and purchased a commercial C4D system with claimed performance (conductivity range: 20 nS/cm to 4 µS/cm) appropriate for this application. We characterized the instrument’s performance with conductivity standards and Ag+ solutions. We began investigations considering practical and long-term detector operation, including potential current-induced deposition of conductive deposits at the tubing wall. In addition, we designed a side-stream flow system to provide liquid flow through the narrow tubing (1/16” outer diameter) required by the detector and characterized the performance of the combined C4D detector/flow system. Finally, we completed theoretical modeling of expected conductivity change with multiple dosing techniques and water chemistries.

Lance Dean Delzeit↗

Considerations on Electrolytic Conductivity Measurement for Monitoring of Ionic Silver Biocide Dosing

NASA interest in ionic silver (Ag+) as a biocide for spacecraft potable water systems motivates the development of Ag+ concentration sensors to ensure nominal dosing. The electrolytic conductivity change of highly-purified potable water is linearly related to the concentration of chemically-dosed Ag+ and could serve as a useful proxy measurement, while the conductivity change during electrolytic dosing may be less so, depending on the influent water chemistry and electrolytic efficiency. Understanding and mitigating the potentially deleterious effects of Ag+ interaction with conductivity measurement systems requires investigation. Issues associated with traditional conductivity cells, which rely on wetted(typically metal or graphite) electrodes, and capacitively-coupled contactless conductivity detection (C4D) for this application are considered. Traditional conductivity cells may potentially be subject to significant excitation-induced or auto-galvanic reduction of Ag+. These may result in Ag+ depletion or electrode fouling and associated measurement error. Proper selection of electrode material, excitation parameters, and cell geometry may limit such effects. C4D uses electrodes placed outside an inert, insulating material, with dielectric polarization enabling the production of an electric field and resultant current across the analyte solution. This approach could potentially mitigate problems with Ag+ depletion and fouling by eliminating the possibility of auto-galvanic deposition and reducing the Faradaic current density. However, it is necessary to confirm C4D performance at very low conductivity levels and to determine if long-term operation produces conductive deposits, which could result in measurement error. A commercial C4D system with 1/16” (1.59 mm)outer diameter flow tubing and claimed performance in the conductivity range appropriate for this application was identified, and its sensitivity in the upper parts of this range was confirmed in a preliminary experiment. A concept for a C4D detector that could allow for full rate flow-through using planar electrodes and thin-film dielectric layers is discussed.

silver↗

Understanding the speciation of molten iodide salts via spectro-electrochemistry

Iodine is a high yield fission product of concern for the environmental effects due to its high volatility and biological impacts to the human body. Iodine speciation in molten salts, specifically iodide salts, is not well understood due to its reactivity at higher temperature domains. UV-Vis spectroscopy indicates a change in the speciation of the molten iodide salts starting at 500oC based on the decomposition of the salt itself, forming I3- ions. This work investigated the spectral changes of I- ions in molten LiI-KI and LiI-KI-NiI2 while manipulating the salts electrochemically using an inert graphite electrode at 400oC.The Li+/Li(s) and the Ni2+/Ni(s) transitions were studied using cyclic voltammetry, chronoamperometry/chronopotentiometry to characterize the respective reduction-oxidation waves. As cyclic voltammetry was applied, the UV-Vis spectroscopy showed a change in the characteristic signal of molten LiI-KI, indicating a disproportionation reaction in the molten salt, leading to formation of I3- ions and I2 gas.

36 - MATERIALS SCIENCE↗

Electrochemical behavior and separation of iodide in molten LiF-NaF-KF melt

This work studied the electrochemical behavior of iodide in molten LiF-NaF-KF mixture and the separation of iodide from the molten salt at 973 K using a graphite working electrode. The cyclic voltammetry (CV) and chronoamperometry (CA) measurements indicated an anodic passivation layer was formed on the graphite electrode in this melt and the layer blocked the charge transfer across the electrolyte/electrode interface. However, the added I- ions could pass through the passivation layer and were oxidized at the graphite electrode. The characterization of the obtained products proved that iodide ions was efficiently oxidized to I2 gas during electrolysis. Furthermore, the graphite anode showed excellent stability without any obvious change in dimensions after electrolysis, which showed the high current efficiency of I2 evolution reaction. Thus, the graphite electrode was possible to be served as an excellent anode to separate other anions (such as Br) from molten fluoride salts.

36 MATERIALS SCIENCE↗

MnO{sub 2}-wrapped hollow graphitized carbon nanosphere electrode for supercapacitor

Highlights: • MnO{sub 2}/HGC nanospheres are prepared by a cooperative template wrapping method. • MnO{sub 2}/HGC nanospheres possess large specific surface area. • MnO{sub 2}/HGC nanospheres are benefit for transmission of ions and electrons. • MnO{sub 2}/HGC electrodes exhibit a high specific capacitance. - Abstract: MnO{sub 2}-wrapped hollow graphitized carbon nanospheres (MnO{sub 2}/HGC) electrodes are prepared by a cooperative template wrapping method. hollow Graphitized carbon nanospheres (HGC) are firstly obtained by carbonizing phenolic resin followed by etching the SiO{sub 2} template, then the MnO{sub 2} ultrathin nanoplates are coated on the surfaces of the HGC nanospheres through a redox reaction between KMnO{sub 4} and HGC nanospheres. The as-prepared MnO{sub 2}/HGC hollow nanospheres possess porous structure and large specific surface area (∼230 m{sup 2} g{sup −1}). The specific capacitances of MnO{sub 2}/HGC nanosphere electrodes with different mass ratios of MnO{sub 2} to HGC are about 340–380 F g{sup −1} at a scan rate of 5 mV s{sup −1} in Na{sub 2}SO{sub 4} solution, and shows relative good cycling performance of the initial capacitance after 1000 cycles. The good specific capacitance is ascribed to the novel hollow nanosphere structure, which possesses high surface-to-volume ratio, and makes it easy for the mass diffusion of electrolyte and transmission of ions and electrons and also maintains the mechanical integrality.

36 MATERIALS SCIENCE↗

Traveling-wave tube efficiency improvement with textured pyrolytic graphite multistage depressed collector electrodes

The improved efficiency of a multistage depressed collector (MDC) with ion-beam textured pyrolytic graphite electrode surfaces is demonstrated by comparison with the performance of other MDC's tested with the same microwave RF amplifier traveling-wave tube (TWT). Because of the sensitivity of overall TWT efficiency to collector efficiency, significant improvements in TWT performance are possible with the use of textured pyrolytic graphite MDC's.

Curren, A. N.↗

Eeffect of electrolyte composition on initial cycling and impedance characteristics of lithium-ion-cells.

Hybrid-electric vehicles require lithium-battery electrolytes that form stable, low impedance passivation layers to protect the electrodes, while allowing rapid lithium-ion transport under high current charge/discharge pulses. In this article, we describe data acquired on cells containing LiNi{sub 0.8}Co{sub 0.15}Al{sub 0.05}O{sub 2}-based positive electrodes, graphite-based negative electrodes, and electrolytes with lithium hexafluorophosphate (LiPF{sub 6}), lithium tetrafluoroborate (LiBF{sub 4}), lithium bis(oxalato)borate (LiBOB) and lithium difluoro(oxalato) borate (LiF{sub 2}OB) salts. The impedance data were collected in cells containing a Li-Sn reference electrode to determine effect of electrolyte composition and testing temperature on individual electrode impedance. The full cell impedance data showed the following trend: LiBOB > LiBF{sub 4} > LiF{sub 2}OB > LiPF{sub 6}. The negative electrode impedance showed a trend similar to that of the full cell; this electrode was the main contributor to impedance in the LiBOB and LiBF{sub 4} cells. The positive electrode impedance values for the LiBF{sub 4}, LiF{sub 2}OB, and LiPF{sub 6} cells were comparable; the values were somewhat higher for the LiBOB cell. Cycling and impedance data were also obtained for cells containing additions of LiBF{sub 4}, LiBOB, LiF{sub 2}OB, and vinylene carbonate (VC) to the EC:EMC (3:7 by wt.) + 1.2 M LiPF{sub 6} electrolyte. Our data indicate that the composition and morphology of the graphite SEI formed during the first lithiation cycle is an important determinant of the negative electrode impedance, and hence full cell impedance.

36 MATERIALS SCIENCE↗

Electrochemical behavior of 0.2 to 3 molar ferrous chloride-ferric chloride mixtures on edge-on pyrolytic graphite rotated disk electrodes

Potentiostatic determinations in various mixtures of FeCl2-FeCl3 with excess HCl show rest potentials that are 0.1 V less electropositive than the theoretical values from the formulated ratios of FeII to FeIII (probably as a result of complexing). The standard rate constant sub s. ranges between 0.0001 and 0.000 cm/sec. Tafel slopes b of roughly 0.12V per decade indicate single-electron exchange kinetics. No significant trend in either b or sub s was attributed to mixture composition. The higher sub s. values occurred with and edge-on pyrolytic graphite that had undergone a permanent surface change.

Miller, R. O.↗

High-capacity nanostructured germanium-containing materials and lithium alloys thereof

Electrodes comprising an alkali metal, for example, lithium, alloyed with nanostructured materials of formula Si.sub.zGe.sub.(z-1), where 0<z.ltoreq.1; formula Si.sub.zGe.sub.(z-1), where 0<z<1; and/or germanium exhibit a combination of improved capacities, cycle lives, and/or cycling rates compared with similar electrodes made from graphite. These electrodes are useful as anodes for secondary electrochemical cells, for example, batteries and electrochemical supercapacitors.

Graetz, Jason A↗

Density impact on performance of composite Si/graphite electrodes

The ability of alkali-substituted binders for composite Si and graphite negative electrodes to minimize capacity fade for lithium ion batteries is investigated. Polymer films and electrodes are described and characterized by FTIR following immersion in electrolyte (1:2 EC:DMC) for 24 h. FTIR analysis following electrode formation displayed similar alkali-ion dependent shifts in peak location suggesting that changes in the vibrational structure of the binder are maintained after electrode formation. The Si and graphite composite electrodes prepared using the alkali-substituted polyacrylates were also exposed to electrochemical cycling and it has been found that the performance of the Na-substituted binder is superior to a comparable density K-substituted system. However, in comparing performance across many different electrode densities attention needs to be placed on making comparisons at similar densities, as low density electrodes tend to exhibit lower capacity fade over cycling. This is highlighted by a 6% difference between a low density K-substituted electrode and a high density Na-substituted sample. As a result, this low variance between the two systems makes it difficult to quickly make a direct evaluation of binder performance unless electrode density is tightly controlled.

25 ENERGY STORAGE↗

Study of the Design and Characteristics of a Modified Pulsed Plasma Thruster with Graphite and Tungsten Trigger Electrodes

The paper presents experimental results for a modified pulsed plasma thruster (PPT) with solid propellant, using a coaxial anode–cathode design. Graphite from pencil leads served as propellant, and a tungsten trigger electrode was tested to reduce carbonization effects. Experiments were performed in a vacuum chamber at 0.001 Pa, employing diagnostics such as discharge current/voltage recording, power measurement, ballistic pendulum, time-of-flight (TOF) method, and a Faraday cup. Current and voltage waveforms matched an oscillatory RLC circuit with variable plasma channel resistance. Key discharge parameters were measured, including current pulse duration/amplitude and plasma channel formation/decay dynamics. Impulse bit values, obtained with a ballistic pendulum, reached up to 8.5 μN·s. Increasing trigger capacitor capacitance reduced thrust due to unstable “pre-plasma” formation and partial pre-discharge energy loss. Using TOF and Faraday cup diagnostics, plasma front velocity, ion current amplitude, current density, and ion concentration were determined. Tungsten electrodes produced lower charged particle concentrations than graphite but offered better adhesion resistance, minimal carbonization, and stable long-term performance. The findings support optimizing trigger electrode materials and PPT operating modes to extend lifetime and stabilize thrust output.

Faraday cup↗

Polarity effects and apparent ion recombination in microionization chambers

Purpose: Microchambers demonstrate anomalous voltage-dependent polarity effects. Existing polarity and ion recombination correction factors do not account for these effects. As a result, many commercial microchamber models do not meet the specification of a reference-class ionization chamber as defined by the American Association of Physicists in Medicine. The purpose of this investigation is to determine the cause of these voltage-dependent polarity effects. Methods: A series of microchamber prototypes were produced to isolate the source of the voltage-dependent polarity effects. Parameters including ionization-chamber collecting-volume size, stem and cable irradiation, chamber assembly, contaminants, high-Z materials, and individual chamber components were investigated. Measurements were performed with electrodes coated with graphite to isolate electrode conductivity. Chamber response was measured as the potential bias of the guard electrode was altered with respect to the collecting electrode, through the integration of additional power supplies. Ionization chamber models were also simulated using COMSOL Multiphysics software to investigate the effect of a potential difference between electrodes on electric field lines and collecting volume definition. Results: Investigations with microchamber prototypes demonstrated that the significant source of the voltage-dependent polarity effects was a potential difference between the guard and collecting electrodes of the chambers. The voltage-dependent polarity effects for each prototype were primarily isolated to either the guard or collecting electrode. Polarity effects were reduced by coating the isolated electrode with a conductive layer of graphite. Polarity effects were increased by introducing a potential difference between the electrodes. COMSOL simulations further demonstrated that for a given potential difference between electrodes, the collecting volume of the chamber changed as the applied voltage was altered, producing voltage-dependent polarity effects in the chamber response. Ionization chamber measurements and COMSOL simulations demonstrated an inverse relationship between the chamber collecting volume size and the severity of voltage-dependent polarity effects on chamber response. The effect of a given potential difference on chamber polarity effects was roughly ten times greater for microchambers as compared to Farmer-type chambers. Stem and cable irradiations, chamber assembly, contaminants, and high-Z materials were not found to be a significant source of the voltage-dependent polarity effects. Conclusions: A potential difference between the guard and collecting electrodes was found to be the primary source of the voltage-dependent polarity effects demonstrated by microchambers. For a given potential difference between electrodes, the relative change in the collecting volume is smaller for larger-volume chambers, illustrating why these polarity effects are not seen in larger-volume chambers with similar guard and collecting electrode designs. Thus, for small-volume chambers, it is necessary to reduce the potential difference between the guard and collecting electrodes in order to reduce polarity effects for reference dosimetry measurements.

60 APPLIED LIFE SCIENCES↗

Electrode behavior RE-visited: Monitoring potential windows, capacity loss, and impedance changes in Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 /silicon-graphite full cells

Here, the capacity and power performance of lithium-ion battery cells evolve over time. The mechanisms leading to these changes can often be identified through knowledge of electrode potentials, which contain information about electrochemical processes at the electrode-electrolyte interfaces. In this study we monitor electrode potentials within full cells containing a Li 1.03 (Ni 0.5 Co 0.2 Mn 0.3 ) 0.97 O 2 –based (NCM523) positive electrode, a silicon-graphite negative electrode, and an LiPF6-bearing electrolyte, with and without fluoroethylene carbonate (FEC) or vinylene carbonate (VC) additives. The electrode potentials are monitored with a Li-metal reference electrode (RE) positioned besides the electrode stack; changes in these potentials are used to examine electrode state-of-charge (SOC) shifts, material utilization, and loss of electrochemically active material. Electrode impedances are obtained with a Li x Sn RE located within the stack; the data display the effect of cell voltage and electrode SOC changes on the measured values after formation cycling and after aging. Our measurements confirm the beneficial effect of FEC and VC electrolyte additives in reducing full cell capacity loss and impedance rise after cycling in a 3.0–4.2 V range. Comparisons with data from a full cell containing a graphite-based negative highlight the consequences of including silicon in the electrode. Our observations on electrode potentials, capacity, and impedance changes on cycling are crucial to designing long-lasting, silicon-bearing, lithium-ion cells.

25 ENERGY STORAGE↗

Unlocking Mesoscopic Disorder in Graphitic Carbon with Spectroelectrochemistry

Intrinsic structural and oxidic defects activate graphitic carbon electrodes towards electrochemical reactions underpinning energy conversion and storage technologies. Yet, these defects can also disrupt the long-range and periodic arrangement of carbon atoms, thus, the characterization of graphitic carbon electrodes necessitates in-situ atomistic differentiation of graphitic regions from mesoscopic bulk disorder. Here, we leverage the combined techniques of in-situ attenuated total reflectance infrared spectroscopy and first-principles calculations to reveal that graphitic carbon electrodes exhibit electric-field dependent infrared activity that is sensitive to the bulk mesoscopic intrinsic disorder. With this platform, we identify graphitic regions from amorphous domains by discovering that they demonstrate opposing electric-field-dependent infrared activity under electrochemical conditions. Our work provides a roadmap for identifying mesoscopic disorder in bulk carbon materials under potential bias.

Disordered graphitic carbon electrodes↗

Binder-free thin graphite fiber mat sandwich electrode architectures for energy-efficient vanadium redox flow batteries

Vanadium redox flow batteries (VRFB) are emerging as the preferred energy storage solution for long-duration energy storage (LDES) and grid-scale load levelling. In this study, we report a novel binder-free sandwich electrode architecture consisting of a thin layer (6–12 mg cm –2 ) of thermally activated graphite felt mat (TGFM) sandwiched between thin carbon papers (TCP-TGFM-TCP). This electrode architecture substantially reduced the polarization (I-V) resistance of the VRFB by 23 %, resulting in a current density increase from 340 mA cm –2 at 1 V for the thermally activated graphite felt (TGF) electrode to 470 mA cm –2 at 1 V, and an energy efficiency of 80 % at 100 mA cm –2 is realized.

25 ENERGY STORAGE↗

Voltammetric determination of vitamin B{sub 6} (pyridoxine) at a graphite screen-printed electrode modified with graphene oxide/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite

The preparation and study of electrochemical properties of a graphite screen-printed electrode (SPE) modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} (GO is graphene oxide) nanocomposites are described. The morphologies of the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposites were examined by scanning electron microscopy. The electrochemical oxidation of vitamin B{sub 6} (pyridoxine) on SPE modified with the GO/Fe{sub 3}O{sub 4}@SiO{sub 2} nanocomposite was investigated by cyclic voltammetry, differential pulse voltammetry, and chronoamperometry. Under optimum conditions (pH 7.0), the vitamin B{sub 6} oxidation at the surface of the modified SPE occurs at a potential about 190 mV less positive than that at the unmodified SPE. A linear voltammetric response for vitamin B{sub 6} was obtained in the concentration range 1.0•10 {sup 6}—9.0•10 {sup 4} mol L{sup –1} with a detection limit of 5.2•10 {sup 7} mol L{sup –1} using differential pulse voltammetry. The developed sensor was also successfully applied for determination of trace level of vitamin B{sub 6} in both the standard vitamin B{sub 6} sample and biological samples (urine).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗