Search NASA⌕ Search

SEARCH · Search NASA

Results for “grating array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation

A common problem in optical detection is determining the arrival time of a weak optical pulse that may comprise only one to a few photons. Currently, this problem is solved by using a photodetector to convert the optical signal to an electronic signal. The timing of the electrical signal is used to infer the timing of the optical pulse, but error is introduced by random delay between the absorption of the optical pulse and the creation of the electrical one. To eliminate this error, a time-to-space converter separates a sequence of optical pulses and sends them to different photodetectors, depending on their arrival time. The random delay, called jitter, is at least 20 picoseconds for the best detectors capable of detecting the weakest optical pulses, a single photon, and can be as great as 500 picoseconds. This limits the resolution with which the timing of the optical pulse can be measured. The time-to-space converter overcomes this limitation. Generally, the time-to-space converter imparts a time-dependent momentum shift to the incoming optical pulses, followed by an optical system that separates photons of different momenta. As an example, an electro-optic phase modulator can be used to apply longitudinal momentum changes (frequency changes) that vary in time, followed by an optical spectrometer (such as a diffraction grating), which separates photons with different momenta into different paths and directs them to impinge upon an array of photodetectors. The pulse arrival time is then inferred by measuring which photodetector receives the pulse. The use of a time-to-space converter mitigates detector jitter and improves the resolution with which the timing of an optical pulse is determined. Also, the application of the converter enables the demodulation of a pulse position modulated signal (PPM) at higher bandwidths than using previous photodetector technology. This allows the creation of a receiver for a communication system with high bandwidth and high bits/photon efficiency.

Birnbaum, Kevin↗

Verification and Validation of Hybridspectral Radiometry Obtained from an Unmanned Surface Vessel (USV) in the Open and Coastal Oceans

The hardware and software capabilities of the compact-profiling hybrid instrumentation for radiometry and ecology (C-PHIRE) instruments on an unmanned surface vessel (USV) are evaluated. Both the radiometers and USV are commercial-off-the-shelf (COTS) products, with the latter being only minimally modified to deploy the C-PHIRE instruments. The hybridspectral C-PHIRE instruments consist of an array of 18 multispectral microradiometers with 10 nm wavebands spanning 320–875 nm plus a hyperspectral compact grating spectrometer (CGS) with 2048 pixels spanning 190–1000 nm. The C-PHIRE data were acquired and processed using two architecturally linked software packages, thereby allowing lessons learned in one to be applied to the other. Using standard data products and unbiased statistics, the C-PHIRE data were validated with those from the well-established compact-optical profiling system (C-OPS) and verified with the marine optical buoy (MOBY). Agreement between algorithm variables used to estimate colored dissolved organic matter (CDOM) absorption and chlorophyll a concentration were also validated. Developing and operating novel technologies, such as the C-PHIRE series of instruments, deployed on a USV increase the frequency and coverage of optical observations, which are required to fully support the present and next-generation validation exercises in radiometric remote sensing of aquatic ecosystems.

Hybridspectral↗

The evaluation of a deformable diffraction grating for a stigmatic EUV spectroheliometer

Two crucial areas in the development of the high resolution EUV spectroheliometer are the elastically deformable toroidal diffraction grating and the open-structure imaging pulse counting detector system. The optical performance of a high frequency toroidal grating at EUV wavelengths was verified with a 3600 groove/mm master grating on a spherical concave blank. An open-structure (256 x 1024) pixel, multi-anode microchannel array was developed and tested as a pulse counting detector system. These two systems verify the proof of concept of the spectroheliometer design.

Timothy, J. G.↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses that may not be important in longer wavelength designs. This paper describes the design of multi- bandwidth filters operating in the 1-5 micrometer wavelength range. This work follows on a previous design. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using microlithographic techniques and used in spectral imaging applications will be presented.

Cwik, Tom↗

Multi-Bandwidth Frequency Selective Surfaces for Near Infrared Filtering: Design and Optimization

Frequency selective surfaces are widely used in the microwave and millimeter wave regions of the spectrum for filtering signals. They are used in telecommunication systems for multi-frequency operation or in instrument detectors for spectroscopy. The frequency selective surface operation depends on a periodic array of elements resonating at prescribed wavelengths producing a filter response. The size of the elements is on the order of half the electrical wavelength, and the array period is typically less than a wavelength for efficient operation. When operating in the optical region, diffraction gratings are used for filtering. In this regime the period of the grating may be several wavelengths producing multiple orders of light in reflection or transmission. In regions between these bands (specifically in the infrared band) frequency selective filters consisting of patterned metal layers fabricated using electron beam lithography are beginning to be developed. The operation is completely analogous to surfaces made in the microwave and millimeter wave region except for the choice of materials used and the fabrication process. In addition, the lithography process allows an arbitrary distribution of patterns corresponding to resonances at various wavelengths to be produced. The design of sub-millimeter filters follows the design methods used in the microwave region. Exacting modal matching, integral equation or finite element methods can be used for design. A major difference though is the introduction of material parameters and thicknesses tha_ may not be important in longer wavelength designs. This paper describes the design of multi-bandwidth filters operating in the I-5 micrometer wavelength range. This work follows on previous design [1,2]. In this paper extensions based on further optimization and an examination of the specific shape of the element in the periodic cell will be reported. Results from the design, manufacture and test of linear wedge filters built using micro-lithographic techniques and used ir spectral imaging applications will be presented.

Cwik, Tom↗

Development and Airborne Demonstration of the Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System: Advancing Lidar Capabilities for the STV Observing System

We report on the design, build and planned airborne demonstration of a spaceflight-prototype Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS). The CASALS lidar is an Adaptive Wavelength Scanning Lidar (AWSL) operating in push broom mode. The demonstration has three major goals: advance the Technical Readiness Level of the AWSL hardware, validate its measurement performance and mature algorithms and methods needed for the Surface Topography and Vegetation (STV) observing system. AWSL acquires parallel tracks of surface heights by rapidly steering a laser beam across a swath. A 1040nm-centered laser is tuned across 30nm and carved into 2-ns pulses, the pulse energy is fiber amplified and the pulses are dispersed cross-track using a non-mechanical wavelength-to-angle grating. For the spaceflight system the beam will be pointable to 1200 10m footprints across a 7km swath. For the airborne demonstration there will be 256 0.7m footprints across a 110m swath. In both cases the footprints overlap across- and along-track for uniform target illumination. For the airborne demonstration a steering mirror will increase the accessible swath width to 4km. At the receiver, solar radiation is filtered with a narrow-slit grating-spectrometer and the footprints are imaged onto a linear-mode, photon-sensitive HgCdTe APD-array. The received pulses are time-division-multiplexed to a few high-speed analog-to-digital converters to record waveforms. Spaceflight and airborne CASALS are designed to nominally detect 20 photons per pulse and, by averaging 27 overlapping footprints, achieve 2cm flat target range precision and high-quality vegetation structure waveforms The AWSL will be flown in the summer of 2024, along with a Headwall VNIR-SWIR hyperspectral sensor imaging a 4km wide swath, at NEON eddy covariance flux towers in the U.S. mid-Atlantic where high resolution hyperspectral and lidar data, acquired annually, are available for validation.

Guangning Yang↗

Lens-free compound eye cameras based on angle-sensitive meta-surfaces

A lens-free ultrathin imaging sensor using a compound-eye vision modality can be formed by forming a metasurface on each pixel of an array of pixels in a solid state imaging sensor. The metasurface can be configured to form a diffraction grating that directs light incident on the metasurface at a predefined angle to excite surface plasmon polaritons into the solid state imaging sensor and light incident at any other angle is reflected or diffracted away from the metasurface. Each pixel of the imaging sensor can be configured using the metasurface to only receive light incident from a different portion of a field of view. A computational imaging system can be used to construct the image from the individual pixels.

Paiella, Roberto↗

Optical Phased Array Using Guided Resonance with Backside Reflectors

Methods and systems for controlling the phase of electromagnetic waves are disclosed. A device can consist of a guided resonance grating layer, a spacer, and a reflector. A plurality of devices, arranged in a grid pattern, can control the phase of reflected electromagnetic phase, through refractive index control. Carrier injection, temperature control, and optical beams can be applied to control the refractive index.

Horie, Yu↗

Optical Phased Array Using Guided Resonance with Backside Reflectors

Methods and systems for controlling the phase of electromagnetic waves are disclosed. A device can consist of a guided resonance grating layer, a spacer, and a reflector. A plurality of devices, arranged in a grid pattern, can control the phase of reflected electromagnetic phase, through refractive index control. Carrier injection, temperature control, and optical beams can be applied to control the refractive index.

Horie, Yu↗

NASA/GSFC program in direct detection optical communications for intersatellite links

NASA-Goddard has undertaken the development of direct-detection optical communications for space applications at the Gbps data rate channel capability level. The primary challenges to optical communications designers lie in the development of reliable optical power sources, as well as of high performance pointing/acquisition/tracking systems required by the narrow widths of the transmitted optical beams. GaAlAs diodes and their arrays are currently the most attractive technology for optical transmitters; pioneering work has also been conducted on dichroic and grating techniques for combining the power of several laser diodes. Attention is given to the performance obtained for an optical link acquisition and submicroradian tracking/pointing system.

Fitzmaurice, M.↗

OPAD 1991

The Optical Plume Anomaly Detection Program, an experimental study in the attempt to create a rocket engine health monitor based on detection and possible quantification of anomalous atomic and molecular species in the exhaust plume, has been in existence for several years. The instruments developed to monitor the exhaust plumes are presented. Two optical instruments are employed: the polychromator and the spectrometer. The polychromator is a 16 channel spectroradiometer having independent channels individually adjustable for center wavelength and pass bandwidth. Those values may be mechanically reset, with the aid of certain lab equipment. The spectrometer is a multichannel spectral analyzer having two 2048 element linear photodiode arrays at the exit plane of the dispersing instrument, which, like the 16 channel device, is a 1/2 meter grating spectrograph. These instruments are equipped with ultraviolet grade multifiber optical input cables, allowing the instruments to be placed in a benign environment. Telescopes mounted on the test stand observe the plume keeping the shock structure in view. The data acquisition and control system consist of four 80386-33 MHz computers: two at the test stand for instrument control and data preconditioning, and two in the test support building providing data archiving, display, and system control. Further descriptions of the instrumentation are provided.

Powers, W. T.↗

Detector Arrays for an Airborne Infrared Echelle Spectrometer

The design of a long-slit echelle spectrograph covering the 16 - 210 micron range for use on the Stratospheric Observatory for Infrared Astronomy (SOFIA) is under study at NASA-Ames. This wavelength range is selected for its content of important astrophysical spectral lines accessible from an airborne platform, and availability of suitable detectors. Two dimensional arrays will be used to simultaneously provide spectral coverage in the dispersion direction and imaging in the cross-dispersion direction. Major goals are: (1) to reach sensitivities limited primarily by the background from the residual atmosphere and the telescope; (2) to provide imaging not far from the diffraction limit of the 2.5 meter (effective) aperture of the telescope; and (3) to obtain diffraction-limited spectral resolution from the large echelle grating, which means that the resolving power increases with decreasing wavelength. To meet these requirements, three detector types are forseen: a commercially available monolithic Si:Sb IBC array to cover the wavelength range from 16 to 40 microns, a Ge:Sb photoconductor array to cover the range from 40 to 125 microns, and a stressed Ge:Ga photoconductor array covering the range from 125 to 210 microns. The paper discusses details of the studies and plans for the field optics, detectors, and readouts.

Erickson, E. F.↗

NASA Tech Briefs, December 2009

Topics include: A Deep Space Network Portable Radio Science Receiver; Detecting Phase Boundaries in Hard-Sphere Suspensions; Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery; Very-Long-Distance Remote Hearing and Vibrometry; Using GPS to Detect Imminent Tsunamis; Stream Flow Prediction by Remote Sensing and Genetic Programming; Pilotless Frame Synchronization Using LDPC Code Constraints; Radiometer on a Chip; Measuring Luminescence Lifetime With Help of a DSP; Modulation Based on Probability Density Functions; Ku Telemetry Modulator for Suborbital Vehicles; Photonic Links for High-Performance Arraying of Antennas; Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration; Hardware-Efficient Monitoring of I/O Signals; Video System for Viewing From a Remote or Windowless Cockpit; Spacesuit Data Display and Management System; IEEE 1394 Hub With Fault Containment; Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph; Waveguide Transition for Submillimeter-Wave MMICs; Magnetic-Field-Tunable Superconducting Rectifier; Bonded Invar Clip Removal Using Foil Heaters; Fabricating Radial Groove Gratings Using Projection Photolithography; Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates; Method for Measuring the Volume-Scattering Function of Water; Method of Heating a Foam-Based Catalyst Bed; Small Deflection Energy Analyzer for Energy and Angular Distributions; Polymeric Bladder for Storing Liquid Oxygen; Pyrotechnic Simulator/Stray-Voltage Detector; Inventions Utilizing Microfluidics and Colloidal Particles; RuO2 Thermometer for Ultra-Low Temperatures; Ultra-Compact, High-Resolution LADAR System for 3D Imaging; Dual-Channel Multi-Purpose Telescope; Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting; CMOS Camera Array With Onboard Memory; Quickly Approximating the Distance Between Two Objects; Processing Images of Craters for Spacecraft Navigation; Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System; Rover Slip Validation and Prediction Algorithm; Safety and Quality Training Simulator; Supply-Chain Optimization Template; Algorithm for Computing Particle/Surface Interactions; Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images; and Thermal Transport Model for Heat Sink Design.

Source record↗

Development of Concurrent Artificially-Intelligent Spectrometry and Adaptive Lidar System (CASALS) for Swath Mapping From Space

We present the design and performance of a Concurrent Artificially-intelligent Spectrometry and Adaptive Lidar System (CASALS) for 3D imaging from Space. With a single fast wavelength tuning laser, CASALS accomplishes a 1,200 resolvable spots swath mapping by grating dispersion wavelength steering. Any subset of these 1,200 spots can be selected by wavelength switching. The validation operating principle was accomplished and reported in IGASS-2022. With configurable base design, we report the designs and progress of the CASALS airplane campaign with 256 contiguous ground spots. It is accomplished with a single fast tuning lase at 1040-nm, 1.152MHz tuning rate, and pulse modulated 2-ns on each wavelength. Return pulses are mapped to an eight-pixel detector array with single-photon sensitivity. The lidar returns are time-multiplexed to two outputs that are digitized with two 1-GSPS-digitizer. A grating spectrometer rejects solar background noise spatially and spectrally. We are developing a 1040-nm CASALS intended for multiple LEO orbit missions: Earth Venture Mission on ESPA Grande, STV Mission on ESPA Grande SmallSat, STV Mission on spacecraft equivalent to ICESat power (SWaP,) and splitting the laser beam requires higher laser pulse energy.

ranging lidar↗

Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-Millimetre Spectrograph (BLISS) for SPICA

We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda = 35-435 microns and with R = lambda/(delta)lambda approx. 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10(exp -20) W/Hz(1/2) and response time t<30ms. We expect background-limited performance from bilayers TESs with T(sub c)=65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power PD, is less than 200aW. We describe criteria for measuring P? that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) > or = 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(1/2) and tapprox.5ms for straight-beam TESs. In fact, we expected NEPapprox.1.5x10(exp -19)W/Hz(1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10(exp -19)W/Hz(1/2) in our single-pixel test system and NEP=(1.6+0.3)x10(exp -19)W/Hz(1/2) in our array test system.

transition-edge sensors↗

Development of Fast, Background-Limited Transition-Edge Sensors for the Background-Limited Infrared/Sub-mm Spectrograph (BLISS) for SPICA

We report experimental progress toward demonstrating background-limited arrays of membrane-isolated transition-edge sensors (TESs) for the Background Limited Infrared/Sub-mm Spectrograph (BLISS). BLISS is a space-borne instrument with grating spectrometers for wavelengths lambda=35-435 micron and with R=lambda/delta lambda approximately equals 500. The goals for BLISS TESs are: noise equivalent power (NEP) = 5x10 (sup -20) W/Hz(exp 1/2) and response time tau <30ms. We expect background-limited performance from bilayers TESs with T(sub c) = 65mK and G=15fW/K. However, such TESs cannot be operated at 50mK unless stray power on the devices, or dark power P(sub D), is less than 200aW. We describe criteria for measuring P(sub D) that requires accurate knowledge of TC. Ultimately, we fabricated superconducting thermistors from Ir (T(sub c) >= 135mK) and Mo/Cu proximitized bilayers, where T(sub c) is the thermistor transition temperature. We measured the Ir TES arrays in our 50mK adiabatic demagnetization refrigerator test system, which can measure up to eight 1x32 arrays simultaneously using a time-division multiplexer, as well as our single-pixel test system which can measure down to 15mK. In our previous Ir array measurements our best reported performance was NEP=2.5x10(exp -19) W/Hz(sub 1/2) and Tau approximately equals 5ms for straight-beam TESs. In fact, we expected NEP approximately equals 1.5x10(exp -19)?W/Hz(sup 1/2) for meander beam TESs, but did not achieve this previously due to 1/f noise. Here, we detail improvements toward measuring the expected NEP and demonstrate NEP=(1.3+0.2)x10 (sup -19)W/Hz(exp 1/2) in our single-pixel test system and NEP=(1.6+/-0.3)x10(sup -19)W/Hz(sup 1/2) in our array test system.

infrared spectrometer↗

Chirped-grating spectrometer-on-a-chip

We demonstrate an on-chip spectrometer readily integrable with CMOS electronics. The structure is comprised of a SiO 2 /Si 3 N 4 /SiO 2 waveguide atop a silicon substrate. A transversely chirped grating is fabricated, in a single-step optical lithography process, on a portion of the waveguide to provide angle and wavelength dependent coupling to the guided mode. The spectral and angular information is encoded in the spatial dependence of the grating period. A uniform pitch grating area, separated from the collection area by an unpatterned propagation region, provides the out-coupling to a CMOS detector array. A resolution of 0.3 nm at 633 nm with a spectral coverage tunable across the visible and NIR (to ∼ 1 µm limited by the Si photodetector) by changing the angle of incidence, is demonstrated without the need for any signal processing deconvolution. This on-chip spectrometer concept will cost effectively enable a broad range of applications that are beyond the reach of current integrated spectroscopic technologies.

Nezhadbadeh, Shima↗

Measurements of mass flow in the transition region and inner corona

A solar rocket experiment launched on June 5, 1979 is described which provides high spectral resolution line profiles across the solar disk. The instrument consists of a small telescope with moderate spatial resolution and a spectrograph with stability and high spectroscopic resolution (about 0.028 A at 600 A). The detector system uses a microchannel plate array to provide 1,024 simultaneous measurements spanning approximately 30 A of the solar spectrum. The spectrograph uses a 3600 l/mm grating, and the spectral range 609-634 A is recorded in second order overlapping 1218-1268 A in first order. The position of the emission lines is determined by a center-of-mass routine and velocity shifts are evident. The qualitative results are in general agreement with the results of Cushman and Rense (1976).

Rottman, G. J.↗