Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Enhancing Short-Term Flexibility through Characterization of HVDC Transmission Systems

Efficient power grid operation hinges on maintaining safety and reliability through adaptable system flexibility standards. However, in a future power grid characterized by extensive renewable energy integration, conventional system flexibility and predetermined requirements may falter under extreme conditions. This paper addresses the formidable challenge of sustaining secure and dependable power grid operations under these circumstances, emphasizing the role of controllable high voltage direct current (HVdc) transmission systems in amplifying overall system flexibility and tackling operational complexities. To quantitatively assess short-term flexibility and its associated economic benefits from HVdc within specific regions, we propose a Power Flow Distribution Factors (PTDFs) based approach. This methodology takes into account both dispatchable generators and HVdc systems, pinpointing their contributions. Through an analysis of the Western Electricity Coordinating Council (WECC) system, we demonstrate the practical application of this approach to scrutinize the impacts of existing and future HVdc lines.

Operational Flexibility, Multi-terminal HVdc, tran↗

How Fisheries Biologists Can Facilitate the Clean Energy Transition

Abstract Fisheries and aquatic biologists play a critical role in creating environmentally protective hydropower flow requirements that govern flow timing, frequency, magnitude, and rate of change. Hydropower's role in the U.S. electrical grid is expected to evolve in response to increased wind and solar generation as hydropower will be called upon to quickly ramp up and down in response to changes in wind and solar generation. For this reason, hydropower is expected to have increased value as fossil generation is phased out, even as rapid flow fluctuations linked with hydropower flexibility may strand fish, alter habitat, and create unsafe recreational conditions. We face a new challenge in facilitating the renewable energy transition—designing environmental flow requirements that protect against the impacts of flow fluctuations while allowing adequate hydropower flexibility to support a stable grid. In this paper, we discuss hydropower environmental flow requirements, operational flexibility, and electrical grid stability, their potential interactions, and opportunities to align environmental and power system needs to support healthy ecosystems, multiple water uses, and decarbonization of the electric grid.

13 HYDRO ENERGY↗

Networked HIL Simulation System for Modeling Large-scale Power Systems

This paper presents a networked hardware-in-the-loop (HIL) simulation system for modeling large-scale power systems. Researchers have developed many HIL test systems for power systems in recent years. Those test systems can model both microsecond-level dynamic responses of power electronic systems and millisecond-level transients of transmission and distribution grids. By integrating individual HIL test systems into a network of HIL test systems, we can create large-scale power grid digital twins with flexible structures at required modeling resolution that fits for a wide range of system operating conditions. This will not only significantly reduce the need for field tests when developing new technologies but also greatly shorten the model development cycle. In this paper, we present a networked OPAL-RT based HIL test system for developing transmission-distribution coordinative Volt-VAr regulation technologies as an example to illustrate system setups, communication requirements among different HIL simulation systems, and system connection mechanisms. Impacts of communication delays, information exchange cycles, and computing delays are illustrated. Simulation results show that the performance of a networked HIL test system is satisfactory.

Xie, Fuhong↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Incorporation of market signals for the optimal design of post combustion carbon capture systems

Recent studies have shown that fossil generators equipped with post-combustion carbon capture (PCC) systems are needed to reduce the cost of deep decarbonization. Such generators need to be flexible and responsive to grid conditions, particularly in a high variable renewable energy (VRE) environment. In this work, we evaluate the net present value (NPV) of retrofitting an existing natural gas combined cycle (NGCC) unit with a flexible PCC system while incorporating market signals from a high VRE grid. We use our industrial partner’s NGCC configuration as representative of existing NGCC units and Svante’s rapid-temperature swing adsorption (TSA) for PCC. Because of its ability to rapidly startup/shutdown and ramp-up/ramp-down, the chosen capture technology is very attractive for load-following operations. For a given set of market signals, we formulate a two-stage stochastic multi-period optimization problem, under the price-taker assumption, to simultaneously optimize the design of the capture system and operation of the entire plant. Rigorous models for the NGCC unit, PCC system, and compression system are developed using commercial process simulators and validated with either plant or vendor data. For computational tractability, we develop surrogate/reduced-order models for use in the optimization problem. The surrogate model for the NGCC plant is constructed by linearizing the rigorous dynamic model at 75% load, while data-driven nonlinear surrogate models for the capture and compression systems are constructed using simulation data from the rigorous models. The optimization problem, formulated as a mixed integer bilinear program, is implemented in the IDAES® integrated platform and solved to global optimality using Gurobi 9.5. Using this formulation, we determine the profitability of retrofitting an existing NGCC unit with the chosen capture system for multiple regions in the U.S. under two scenarios with different carbon prices. Importantly, the results show that the optimal decision strongly depends on the region and on the carbon price, thereby demonstrating the importance of the inclusion of market signals in the design process.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

An Assessment of Deploying Advanced Pumped Storage Hydropower Technology in U.S. Electricity Markets

Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Field Insights: Strengthening Digital Assurance Through On-Site Network Monitoring

The accelerating deployment of digital energy infrastructure, ranging from inverter-based resources (IBRs), battery energy storage systems (BESS), to advanced grid control platforms, has brought unprecedented visibility, flexibility, and efficiency to the electric grid. However, this digital transformation also introduces new cybersecurity challenges, particularly in the form of supply chain risks and operational blind spots at the grid edge. Over the past year, the Department of Energy’s Office of Cybersecurity, Energy Security, and Emergency Response (CESER), through its Rapid Risk Assessment initiative, along with the Grid Deployment Office (GDO), through its Technical Assistance for Digital Assurance (TADA) initiative, have supported a series of on-site network engagements led by Idaho National Laboratory (INL). These engagements, conducted in partnership with asset owners across the country, have focused on identifying real-world vulnerabilities and misconfigurations in operational environments, many of which are not detectable through remote assessments or traditional compliance audits. The goal of this report is to distill key findings and lessons learned during network hunt engagements from INL’s fiscal year (FY) 2024 - 2025. It is intended to help asset owners—regardless of their participation in the program—better understand the evolving threat landscape and adopt practical measures to secure their digital energy infrastructure.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Options: A Proposed ISO Product for Managing Energy Imbalance Risk

As the electricity generated by variable resources grows, system operators and variable resources have to manage challenging imbalances between forward and real-time markets. The Flexibility Auction is a novel approach for managing imbalances as it will allow resources with imbalance risk to hedge their production by buying flexibility options. The flexibility options are offered by grid-connected resources that can provide physical flexibility. This presentation provides an overview of the participants in the auction, the definition of flexibility options, and settlements.

27 ARPA - Advanced Research Projects Agency-Energy↗

Flexibility Auctions: A Framework for Managing Imbalance Risk

As the electricity generated by variable resources grows, system operators and variable resources have to manage challenging imbalances between forward and real-time markets. The Flexibility Auction is a novel approach for managing imbalances as it will allow resources with imbalance risk to hedge their production by buying flexibility options. The flexibility options are offered by grid-connected resources that can provide physical flexibility. This presentation will focus on the design of the Flexibility Auction, its properties, and how it can complement system-level services such as CAISO's proposed imbalance reserves. The presentation will include simple examples to illustrate the impact of the Flexibility Auction on the market participants and the system's imbalance risk.

auction↗

Techno-economic analysis of long-duration energy storage and flexible power generation technologies to support high-variable renewable energy grids

As variable renewable energy penetration increases beyond 80%, clean power systems will require long-duration energy storage or flexible, low-carbon generation. Here, we provide a detailed techno-economic evaluation and uncertainty analysis of applicable technologies and identify challenges and opportunities to support electric grid planning. We show that for a 120-h storage duration rating, hydrogen systems with geologic storage and natural gas with carbon capture are the least-cost low-carbon technologies for both current and future capital costs. These results are robust to uncertainty for the future capital cost scenario, but adiabatic compressed air and pumped thermal storage could be the least-cost technologies in the current capital cost scenario under uncertainty. Finally, we present a new storage system using heavy-duty vehicle fuel cells that could reduce the levelized cost of energy by 13%–20% compared with the best previously considered storage technology and, thus, could help enable very high (>80%) renewable energy grids.

25 ENERGY STORAGE↗

Modifications to Solar Titan-130 Combustion Systems for Efficient, High Turndown Operation

The project team of Southwest Research Institute® (SwRI®), Solar Turbines Incorporated (Solar), the Electric Power Research Institute (EPRI), the University of California, Irvine (UCI), and the Georgia Institute of Technology (Georgia Tech) investigated methods to allow higher efficiency part-load operation of a Solar Titan 130 gas turbine. The objective was to develop a low-emission combustion system capable of sustaining combustion and avoiding lean blowout during high turndown operation, which would allow the gas turbine to operate as efficiently as possible at part load. Currently, electric utility markets are beginning to experience substantial increases in renewable energy generation. Some of these renewable energy sources have highly variable output in an uncontrolled manner. In order to maintain grid stability, there is a need for power plants to ramp up power to the grid rapidly to make up for drops in renewable generation. This is often termed spinning reserve, but the size of this reserve may need to increase as renewable penetration into the electric utility market increases. Small combined heat and power (CHP) power plants provide a promising option for meeting this spinning reserve requirement. In order to operate in spinning reserve while still meeting the heat requirements for the CHP, the gas turbine needs to operate efficiently at very low loads. Efficient, high turndown operations in this engine are limited by the lean flammability limit of the premixed combustion system. This project sought enhance the lean operability range of the Titan 130 combustor. First, the project team participated in a brainstorming activity and ultimately selected two concepts to explore: fuel augmentation with hydrogen (H2) to improve the stability at lean operating conditions and modifications to the fuel nozzle to improve the emissions performance at lean operating conditions. Analytical and laboratory investigations were accomplished by UCI to investigate the efficacy of H2 addition at improving lean blow out (LBO) limits and the resulting emissions. These investigations used a variety of chemical reactor network (CRN) and CFD models, validated against laboratory data, to model the impact of H 2 and inform the experimental efforts accomplished by SwRI and Solar. Ultimately, both the CRN and CFD models yielded generally good agreement with the experimental data below a particular temperature threshold. Atmospheric tests of a full-scale T130 annular combustor were performed at SwRI facilities in San Antonio, Texas, to investigate the use of H 2 addition. For these tests, the T130 combustion system remained largely unchanged; minor modifications were performed to the fuel ducting to allow for the safe use of H 2 . The test ultimately demonstrated that the addition of H 2 to the fuel mixture significantly increased the AFR ratio at which the combustor could operate. This improvement to the LBO limit should allow for less use of compressor bleed and less throttling needed by the inlet guide vanes (IGV). This in turn could result in more efficient operation of the gas turbine at lower load points. The second modification explored in this work was a direct modification to the T130 injector. The project team hypothesized that modifications to the pilot of the T130 injector could provide lower emissions at high turn-down operations. These modifications were manufactured and explored by the team at Solar. High pressure rig tests, originally slated to occur at SwRI, were ultimately accomplished by Solar to maintain overall project budget and mitigate cost growth attributable to supply chain issues and inflation. The pressurized rig tests ultimately showed that the SwRI Project No. 18.24153 - DE-EE0008415 Page 2 Final Technical Report January 24, 2024 modifications did not significantly alter the performance of the combustion system at the high turn-down conditions; both the modified injectors and the baseline configuration exhibited elevated emissions comparted to the full-load operating condition. A final set of studies performed by EPRI investigated the benefit-cost of flexible CHP as well as a grid interconnection study for the California Independent System Operator (CAISO) grid. These studies considered: traditional CHP with no spinning reserve available for on-demand grid support, 50% flexible CHP where 50% of the machine’s capacity is consumed by on-site baseload operations while providing an additional 50% capacity for on-demand grid support, and 70% flexible CHP where 70% of capacity is consumed on-site by baseload operations and 30% is available for on-demand grid support. In all cases, the analyses showed a benefit-to-cost ratio greater than unity implying a positive net present value for all configurations. However, the traditional CHP showed the most economic benefit. These results are sensitive to several factors, many of which are not fully known and may vary over time. Thus site owners must be convinced that taking up the increased costs and risks from flexible CHP would be worth implementing. As the grid in California and across the country transition to incorporate larger renewable energy generation, flexible CHP can provide much needed operating reserves and dispatchability. Alternative fuel options, such as hydrogen blending and biofuels, may also lower carbon intensities of CHP. Flexible CHP should be examined in the evolving market to understand innovative business models, changes market rules and services, and new technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Integration of a grey-box refrigerated case model in EnergyPlus via Python plugin

Commercial buildings, in particular grocery stores (due mainly to their large refrigeration load), provide opportunities for energy cost reductions. Grocery stores could offer substantial load flexibility to the power grid through participation in demand response programs because of their usage patterns and relatively high energy intensity. This load flexibility could come from modifying the control of heating, ventilation, and air conditioning (HVAC) systems, refrigeration systems, or both. Although estimation of the HVAC system’s load flexibility potential is relatively targeted in the literature, estimating load flexibility of refrigeration systems is nascent and has been a challenge, in part because of the lack of proper simulation tools that capture the dynamics in the refrigeration cases. The existing refrigerated case model within EnergyPlus, a whole building energy simulation program, assumes a constant case temperature throughout the simulation period and does not explicitly model the cycling of the compressor serving the refrigerated case. In addition, it does not encompass modeling of temperatures of the product inside the refrigerated case. This difference between modeled and actual operation can be a barrier to the development of demand control algorithm and accurate analysis of load flexibility potential. In this paper, we present a grey-box model for modeling refrigerated cases in grocery stores, which include medium temperature and low temperature. Four cases are modeled; two are low-temperature closed cases and two are medium-temperature cases with one closed and one open. Data from an experimental facility are used to train and test the models. Results demonstrate the efficacy of the grey-box models in predicting the temperatures. This model is integrated into EnergyPlus to capture the dynamic effects of case temperature on the environment and enhance the calculation of sensible and latent heat exchange with the environment (case credits). These enhancements can be leveraged more broadly to model advanced refrigeration controls such as defrost, develop and test unique algorithms that could affect refrigeration interactions with HVAC, and refine store design for any commercial building with refrigeration.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hierarchical Transactive Control of Flexible Building Loads Under Distribution LMP

With grid modernization efforts, future distribution networks, which consist of various distributed generators and flexible loads, will be more flexible and active. All new network components of distributed energy resources (DERs) drive and enable the transition towards a market-based distribution net-work that seeks the optimal allocation of all DERs. To address challenges associated with DERs, one promising solution is to utilize demand-side flexibility of building loads facilitated by demand response (DR) programs and provide ancillary grid services through distribution-level markets. Under this new paradigm, this paper proposes an efficient DR management strategy incorporating emerging price signals of distribution markets, i.e., distribution locational marginal price (DLMP), based on a hierarchical transactive control approach. The proposed approach establishes a two-layer decision-making framework; the upper layer formulates a bilevel model to obtain an optimal demand response (ODR) under DLMP, and the lower layer employs model-free control to dispatch the (aggregated) ODR to individual end users. Numerical case studies using a modified IEEE 33 test network are performed to verify the effectiveness of the proposed approach; load shifting and peak shaving for the distribution system operator and payments’ reduction for end users while maintaining their comfort.

Park, Byungkwon↗

Threat Hunt Guide for BESS Environments

The rapid digitalization of the electric grid - driven by the integration of inverter-based resources (IBRs), battery energy storage systems (BESS), and advanced grid control platforms - has significantly enhanced grid efficiency, visibility, and flexibility. However, this evolution also introduces new cybersecurity risks, particularly through supply chain dependencies and operational blind spots at the grid edge. To address these challenges, Idaho National Laboratory (INL), through the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) Rapid Risk initiative, conducted a series of rapid risk assessment engagements with energy organizations across the United States. Drawing on lessons learned from these engagements, INL developed the following threat hunting guide for asset owners and operators (AOOs) to enhance their cybersecurity visibility within BESS and IBR systems. The guide demonstrates how to use passive network monitoring to baseline device behavior, detect adversarial activity, and investigate anomalies without disrupting operations. By implementing these practices, energy sector stakeholders can improve coordination between cybersecurity and operations teams and strengthen the resilience of distributed energy resources (DERs) within the modern power grid. Prior to implementing any network monitoring, packet capture, or threat hunting activity described in this guide, AOOs are strongly advised to review applicable governance frameworks, legal requirements, and organizational policies. This guide is intended for informational and educational purposes only. It does not replace compliance with any federal, state, or local cybersecurity mandates or industry standards. Implementation of described configurations, technologies, or analytic workflows is performed at the discretion and responsibility of the asset owner and operator.

25 - ENERGY STORAGE↗

Power Converter Topologies for Electrolyzer Applications to Enable Electric Grid Services

Hydrogen electrolyzers, with their operational flexibility, can be configured as smart dynamic loads which can provide grid services and facilitate the integration of more renewable energy sources into the electrical grid. However, to enable this ability, the electrolyzer system should be able to control both active and reactive power in coordination with the low-level controller of the electrolyzer via the power electronics system interface between the utility grid and electrolyzer. This paper discusses power converter topologies and the control scheme of this power electronics interface for electrolyzer applications to enable electricity grid services. For the sake of unity, in this paper, we consider the power converter system interfacing the utility grid at the line-to-line root mean square (RMS) value of 480 VAC-60 Hz and supplying to the 3500 A-750 kW PEM electrolyzer stack.

electrolyzer↗

Economic Dispatch Optimization of Multi-Unit SMR Site

With the increase of integration of variable renewable into the grid, grid resilience can be compromised without flexible electricity suppliers. Flexible operation of NPP can expand the scope of integration of new nuclear power plants in regions with high share of renewables. It also provides opportunity to increase profits through participation in ancillary services. In this research, NuScale modules are used as the case study. NuScale is an integrated pressurized water reactor with thermal power of 250 MWth. Having multiple units can provide higher flexibility in changing power levels and supplying the grid with electricity all year long. Additionally, load-following might perturbate the ordered sequence of refueling (every 24 months for NuScale). To maintain the 2 year refueling cycles, the loading patterns will need to be adjusted in a year-to-year basis, resulting in additional unnecessary costs. Another solution is to find the optimal outage schedule. This will also shift the focus of the planned outage to a more optimized predictive outages and maintenance. Results from short-term optimization (i.e., daily participation in energy and ancillary services markets) shows that average commitment to regulation down ancillary service markets during late night and early morning hours can increase revenues. Participating in upward reserves during pre-work commuting hours and early evening hours can also generate additional revenues due to high ramp up of electricity demand. Having multiple units at a single site can also help operate flexibly. Results from long-term optimization show that daily fluctuation in electric power is usually handled by few units while other units operate on base-load profile. It is possible to combine base-load operation with flexible operation to extend component remaining useful life in some units and find optimal outage schedule for the units.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗