An experimentally validated evaporative phase change heat transfer model for low mass flux applications using R134a in plate heat exchangers

Plate frame heat exchangers are common in liquid-coupled vapor compression systems due to their compactness and ease of maintenance. In some of these systems, the refrigerant within the evaporator can enter the heat exchanger as a subcooled liquid. As a result, the refrigerant passes through three different phases: single-phase liquid, two-phase fluid, and a superheated vapor. Unfortunately, there have been limited prior studies that have identified the best method to predict performance under these circumstances. Furthermore, previous investigations have not evaluated refrigerant evaporation in large industrial sized plate frame heat exchangers under conditions experienced in the present study experimental test facility, especially at mass fluxes below 7 kg m –2 s –1 . In the present investigation, a model was developed to predict the performance of plate and frame heat exchangers when the fluid enters as a subcooled liquid and exits as a superheated vapor. The model used full-sized plate heat exchanger geometry that was discretized into 20 sections to accurately capture local heat transfer and pressure drop effects. The model was validated using an R134a counter flow heat exchanger used in a turbo-compression cooling system test facility that had subcooled liquid entering the evaporator at low mass fluxes. A variety of empirical correlations were evaluated to determine what combination yielded the best predictive capability over the following range of conditions: 5.8 < G < 6.8 kg m –2 s –1 , 2 < q” < 2.8 kW m –2 , and 10 °C < T sat < 15 °C. When the correlations used a fixed control volume length in the heat flux calculation, the most accurate combination resulted in a mean absolute error of 5.5%. Finally, future studies can use the approach described here to optimize heat exchanger size and performance.

42 ENGINEERING↗

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Transfer and Interfacial Flow Physics of Microgravity Flow Boiling in Single-Side-Heated Rectangular Channel with Subcooled Inlet Conditions – Experiments Onboard the International Space Station

This study is the culmination of a long-term collaborative effort between researchers from the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and the NASA Glenn Research Center to investigate gravitational effects on flow boiling and flow condensation. The science and design concepts for this large-scale effort were initiated in 2011 and included several studies detailing various aspects of two-phase fluid physics in both Earth gravity and microgravity, culminating in construction of the large-scale experimental facility named “Flow Boiling and Condensation Experiment (FBCE)”. The experiment was launched to the International Space Station (ISS) in August 2021. Following the successful installation of FBCE, equipped with the Flow Boiling Module (FBM), onboard the ISS and completion of several safety checks, flow boiling experiments were performed for five months from February 2022 until July 2022. This resulted in a large flow boiling database covering broad ranges of operating parameters and heating configurations spanning several research objectives. This study investigates microgravity flow boiling of n-perfluorohexane with subcooled inlet in a single-side-heated rectangular channel of dimensions 114.6-mm heated length, 2.5-mm heated width, and 5.0-mm height. Key operating parameters investigated are mass velocity (199.90 – 3200.13 kg/m 2 s), inlet subcooling (0.10 – 45.76°C), and inlet pressure (113.30 – 164.29 kPa). Images and image sequences acquired via high-speed-video are presented to elucidate the interfacial flow physics. To analyze and explain the effects of various parameters in microgravity, heat transfer results are presented as flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and parametric trends of local and averaged heat transfer coefficient. Mass velocity and inlet subcooling significantly influenced most of the aforementioned aspects of flow boiling, whereas effects of inlet pressure were comparatively insignificant. Although the data and observed flow physics might be different, the parametric effects and trends in microgravity are similar to vertical upflow in Earth gravity. Some cases, especially low mass velocities, high heat fluxes, and large degrees of inlet subcooling, experienced temporally anomalous flow behaviors caused by two-phase flow instabilities manifesting as flow reversals and resulted in deviations in overall trends. Severe thermodynamic non-equilibrium is observed throughout the channel. Overall, FBCE’s ISS experiments were successful for subcooled inlet with single-sided heating of rectangular channel, and the collected data well established the various effects on flow boiling physics in highly controlled long-term microgravity conditions.

flow boiling↗

Dual Purpose – Heating & Cooling – Thermal Battery for Flexible and Energy-Efficient Heat Pump Systems

The integration of heat pumps with thermal energy storage (HP-TES) systems is gaining attention as a viable solution for managing peak building demand driven by immense cooling and heating loads. With growing reliance on renewable energy sources, thermal energy storage offers an excellent opportunity to mitigate mismatches in thermal load between energy supply and demand. The use of phase-change material (PCM) TES is especially promising, as PCMs offer significant latent energy storage capacity with smaller temperature glides in smaller volumes compared to other TES technologies. However, challenges arise because current HP-TES architectures can load-shift only cooling or heating, not both, requiring two systems and thus doubling cost, weight, and footprint. Furthermore, current research efforts lack specific tools and techniques to advance integrated systems from concept design to end-user application, focusing on only discharge performance. To address these challenges, this research proposes a dual-mode (heating and cooling) integrated HP-TES system that uses room-temperature PCM-TES as a high-temperature heat source in heating mode and a low-temperature heat sink in cooling mode, thereby reducing temperature lifts and compressor power. Design criteria for PCM-TES heat exchangers were developed, balancing thermal-hydraulic performance with practical constraints such as available building space and weight requirements along with PCM selection considerations such as shipping conditions, moisture exposure, and number of available cycles. A detailed transient model for HP-TES systems was developed to enable rapid annual performance assessments in any US climate zone.

42 ENGINEERING↗

Application of a Novel Heat Pump Model for Estimating Economic Viability and Barriers of Heat Pumps in Dairy Applications in the United States

Heat pumps represent an important opportunity for energy savings and decarbonization. This work investigates the techno-economic performance of high-temperature heat pumps (HTHPs) for use in the U.S. dairy industry. The studied heat pump performs a 50 °C temperature lift on a waste heat stream of cleaning water and applies the upgraded heat stream to a fluid milk pasteurization process. This work involved the creation of a HTHP model that estimated the coefficient of performance (COP), internal rate of return (IRR), net present value (NPV), and payback period (PBP), and emissions saved for a heat pump replacing a natural gas boiler. Capital costs, operations, and maintenance (O&M) cost, heat pump lifetime, electricity prices, natural gas prices, and a cost of carbon were varied to perform a parametric study on the factors affecting the break-even price of HTHPs. The results show that HTHP economics are highly sensitive to COP and energy price environment, and less sensitive to capital and O&M cost variance, leading to a large scatter of positive and negative NPVs based on U.S. location. PBPs demonstrate a defined threshold, based on energy price environment, below which favorable two-to-three-year PBPs predominate. This work is focused on the U.S. dairy industry, but international application in relation to fossil vs. electricity price regimes. Heat pumps have seen wider adoption in regions with a high ratio of fossil energy to electricity prices ($/MMBTU vs. $/kWh). The U.S. has plentiful natural gas resulting in lower fossil energy prices which has reduced heat pump adoption. This paper identifies potential first mover industries for HTHP adoption and their associated price regimes even in regions with lower ratios of fossil energy to electricity prices that exist many places globally.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION,↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

A Simple Criterion for Feasibility of Heat Integration between Distillation Streams Based on Relative Volatilities

In a multicomponent distillation configuration, there are numerous sources and sinks of heat, and a potential way to reduce the heat duty requirement is to perform heat integration. Unfortunately, an algorithmic search of the optimal heat integration opportunities is intractable when the required temperatures of intermediate streams are computed via complex models. Instead, in this work, we introduce pressure-scaled pseudo relative volatility, a new metric to compare stream temperatures. Here, we justify the use of pseudo relative volatility by proving that this variable is a monotonically increasing function of the liquid fraction in a saturated mixture stream. Using this metric, we derive a shortcut criterion to check the feasibility of various heat integration opportunities, such as thermal coupling via heat transfer (TCH). The advantage of this approach is that it circumvents the need for explicit temperatures and instead relies on composition, component relative volatilities, and pressure—quantities that are readily available in shortcut models for optimization of distillation configurations. Leveraging this fact, we propose a new optimization framework that identifies feasible TCHs that we consider within the formulation while minimizing the total heat duty of a distillation configuration. We demonstrate, on a few examples, that our formulation can identify heat duty efficient configurations, some of which are multieffect configurations. Using this methodology, we discover configurations that are not only simpler than the fully thermally coupled (FTC) configuration but also have a much lower heat duty.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minor ion heating in spectra of linearly and circularly polarized Alfvén waves: Thermal and non-thermal motions associated with perpendicular heating

Minor ion (such as He{sup 2+}) heating via nonresonant interaction with spectra of linearly and circularly polarized Alfvén waves (LPAWs and CPAWs hereafter) is studied. The obtained analytic solutions are in good agreement with the simulation results, indicating that newborn ions are heated by low-frequency Alfvén waves with finite amplitude in low-beta plasmas such as the solar corona. The analytic solutions also reproduce the preferential heating of heavy ions in the solar wind. In the presence of parallel propagating Alfvén waves, turbulence-induced particle motion is clearly observed in the wave (magnetic field) polarized directions. After the waves diminish, the newborn ions are heated, which is caused by the phase difference (randomization) between ions due to their different parallel thermal motions. The heating is dominant in the direction perpendicular to the ambient magnetic field. The perpendicular heating, η=(T{sub i⊥}{sup R}−T{sub i0⊥}{sup R})/T{sub i0⊥}{sup R} (where T{sub i0⊥}{sup R} and T{sub i⊥}{sup R} are the perpendicular temperature of species i before and after genuine heating, respectively), in the spectrum of CPAWs is a factor of two stronger than that of LPAWs. Moreover, we also study the effect of field-aligned differential flow speed of species i relative to H{sup +}, δv{sub ip}=(v{sub i}−v{sub p})·B/|B| (where v{sub i} and v{sub p} denote vector velocities of the H{sup +} and species i, respectively), on the perpendicular heating. It reveals that large drift speed, v{sub d}=δv{sub ip}, has an effect on reducing the efficiency of perpendicular heating, which is consistent with observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear fluid simulation of particle and heat fluxes during burst of ELMs on DIII-D with BOUT++ code [Fluid Simulation of Particle and Heat Fluxes during Burst of ELMs on DIID with BOUT++ code]

In order to study the distribution and evolution of the transient particle and heat fluxes during edge-localized mode (ELM) bursts, a BOUT++ six-field two-fluid model based on the Braginskii equations with non-ideal physics effects is used to simulate pedestal collapse in divertor geometry. We used the profiles from the DIII-D H-mode discharge #144382 with fast target heat flux measurements as the initial conditions for the simulations. Moreover, a flux-limited parallel thermal conduction is used with three values of the flux-limiting coefficient ${{\alpha}_{j}}$ , free streaming model with ${{\alpha}_{j}}=1$ , sheath-limit with ${{\alpha}_{j}}=0.05$ , and one value in between. The studies show that a 20 times increase in ${{\alpha}_{j}}$ leads to ~6 times increase in the heat flux amplitude to both the inner and outer targets, and the widths of the fluxes are also expanded. The sheath-limit model of flux-limiting coefficient is found to be the most appropriate one, which shows ELM sizes close to the measurements. The evolution of the density profile during the burst of ELMs of DIII-D discharge #144382 is simulated, and the collapse in width and depth of ${{n}_{\text{e}}}$ are reproduced at different time steps. The growing process of the profiles for the heat flux at divertor targets during the burst of ELMs measured by IRTV (infrared television) is also reproduced by this model. The widths of heat fluxes towards targets are a little narrower, and the peak amplitudes are twice the measurements possibly due to the lack of a model of divertor radiation which can effectively reduce the heat fluxes. The magnetic flutter combined with parallel thermal conduction is found to be able to increase the total heat loss by around 33% since the magnetic flutter terms provide the additional conductive heat transport in the radial direction. Finally, the heat flux profile at both the inner and outer targets is obviously broadened by magnetic flutter. The lobe structures near the X-point at LFS are both broadened and elongated due to the magnetic flutter.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulating a solar parabolic trough collector plant used for industrial process heat using an optimized operating scheme that utilizes flexible heat integration

This study focuses on the modeling and simulation of a novel design and operation of a solar industrial process heat (SIPH) plant that uses a parabolic trough collector system for generating process heat. The SIPH plant incorporates flexible heat integration (FHI) by having two options for heat sinks as well as a flexible collection temperature for the heat transfer fluid. Leveraging the degrees of freedom created by FHI allows an optimized operating scheme to be created which maximizes the solar heat delivered to the industrial processes. Yearly results for a 27 MW-t plant located in Salt Lake City, UT are simulated for a base case and a case utilizing optimized FHI. For the main process temperature case presented, FHI increases the total solar share by 13.0% and reduces the levelized cost of heat of the SIPH plant by 10.4% relative to the base case. Furthermore, three case study days are presented which highlight how FHI maximizes solar share, specifically during mornings, afternoons, and days with intermittent solar conditions. An environmental analysis is also performed showing that the SIPH plant can reduce harmful emissions by 15.4% for the base case and 17.4% for the FHI case compared to a plant that only utilizes a natural gas furnace for process heat. Overall, the work thoroughly explores an effective operating scheme for a SIPH plant, helping to make it more economical and environmentally beneficial.

14 SOLAR ENERGY↗

Testing of a 40-kWth Counterflow Particle-Supercritical Carbon Dioxide Narrow-Channel, Fluidized Bed Heat Exchanger

Particle-based primary heat exchangers (HXs) must deliver sCO2 fluid temperatures above 700°C to couple particle-based concentrating solar receivers and thermal energy storage (TES) sub-systems with efficient sCO2 power cycles. Particle-sCO2 HX designs have struggled to meet DOE cost targets (≤ $150/kWth) due to the amount of expensive nickel alloys necessary for manufacturing full-scale, particle-sCO2 HXs. Our team has demonstrated that mild bubbling fluidization of falling particles in a counterflow narrow-channel fluidized bed can reduce required HX surface area and thus, costs by increasing particle-wall heat transfer coefficients hT,w > 800 W m-2 K-1. This paper reports on the fabrication and testing of a stainless steel, particle-sCO2 HX with 12 fluidized-bed channels approximately 10.5 mm deep spaced between diffusion-bonded, micro-channel sCO2 plates. The HX with a core length of ≈0.56 m is fed with CARBOBEAD HSP particles through a short, fluidized freeboard zone just above the core. Testing to date in the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories has shown that parallel bed fluidization maintains uniform particle inventory across the instrumented channels. Heat transfer thermal duty between the particle and sCO2 flows exceeds 30 kWth with sCO2 inlet temperatures of 200ºC and particle inlet temperatures up to 440ºC and mass flow rates of 0.2 kg s-1 fluidized by counterflowing gas flow rates of 0.005 kg s-1. Tests at higher particle and sCO2 inlet temperatures (600ºC and 400ºC respectively) are targeted to achieve > 40 kWth with model-predicted overall heat transfer coefficients U > 400 W m-2 K-1.

14 SOLAR ENERGY↗

DESIGN OF A COMPACT HEAT EXCHANGER FOR HEAT RECUPERATION FROM A HIGH TEMPERATURE ELECTROLYSIS SYSTEM

Design details of a compact heat exchanger and supporting hardware for heat recuperation in a high-temperature electrolysis application are presented. The recuperative heat exchanger uses a vacuum-brazed plate-fin design and operates between 300 and 800°C. It includes corrugated inserts for enhancement of heat transfer coefficients and extended heat transfer surface area. Two recuperative heat exchangers are required per each four-stack electrolysis module. The heat exchangers are mated to a base manifold unit that distributes the inlet and outlet flows to and from the four electrolysis stacks. Results of heat exchanger design calculations and assembly details are also presented.

08 HYDROGEN↗

Heat exchanger selection and design analyses for metal hydride heat pump systems

This paper presents a design analysis for the development of highly efficient heat exchangers within stationary metal hydride heat pumps. The design constraints and selected performance criteria are applied to three representative heat exchangers. The proposed thermal model can be applied to select the most efficient heat exchanger design and provides outcomes generally valid in a pre-design stage. Heat transfer effectiveness is the principal performance parameter guiding the selection analysis, the results of which appear to be mildly (up to 13%) affected by the specific Nusselt correlation used. The thermo-physical properties of the heat transfer medium and geometrical parameters are varied in the sensitivity analysis, suggesting that the length of independent tubes is the physical parameter that influences the performance of the heat exchangers the most. The practical operative regions for each heat exchanger are identified by finding the conditions over which the heat removal from the solid bed enables a complete and continuous hydriding reaction. The most efficient solution is a design example that achieves the target effectiveness of 95%.

08 HYDROGEN↗

Non-linear dependence of ion heat flux on plasma density at the L–H transition of JET NBI-heated deuterium–tritium plasmas

Abstract Recent JET D–T campaigns opened the possibility of unique isotope studies to investigate the L–H transition physics in view of reactor plasmas and to study the origin of the observed power threshold minimum. In the present paper, we characterise L–H transitions in the low and high-density branches of JET NBI-heated D–T plasmas. As discussed in the paper, L–H transition has been hypothesised to be determined by the transport power losses of plasma ions, i.e. the so-called ion heat flux ( Q i ). We present the first power balance analysis of JET NBI-heated D–T plasmas to evaluate the ion heat flux at the transition. Due to the experimental setting being similar to previous JET D experiments, we also directly compare the results, discussing the isotope effect and similarities between datasets. First, we find an isotope effect between D and D–T Q i , with a lower Q i in D–T plasmas. We confirm that the ion heat flux deviates from density linearity compared to the linear trend observed in wave-heated D plasmas of other tokamaks. The deviation we observe in NBI-heated L–H transitions happens at an isotope-dependent density. Plasma edge rotation correlates with Q i deviation from density linearity in the low-density branch. However, further investigations would be required to assess the role of rotation on Q i and the power threshold minimum at JET. At low plasma density, NBI power dominates Q i , while increasing the density makes the equipartition power dominant. We finally compare our results with hypotheses proposed from evidence in other tokamaks to present a complete overview of ion heat flux analyses in D and D–T NBI-heated plasmas at JET.

Vincenzi, P. (ORCID:0000000251564354)↗

Predicting fatal heat and humidity using the heat index model

A unique wet-bulb temperature of 35°C is often used as the threshold for human survivability, but recent experiments have shown that a person’s core temperature starts to rise at a wide range of critical wet-bulb temperatures. Here, it is shown that the model underlying the heat index correctly predicts those critical wet-bulb temperatures, explaining 95% of the variance in the values observed in laboratory heat-stress experiments. This is the first time the heat-index model has been validated against physiological data from laboratory experiments. For light and moderate exertion in an indoor setting, the heat index model predicts that the critical wet-bulb temperature ranges from 20 to 32°C, depending on the relative humidity, consistent with experimental results. Furthermore, for the same setting and exertion, the heat index model predicts fatal wet-bulb temperatures ranging from 24 to 37°C. Recent experiments have identified the critical combinations of heat and humidity, in an indoor setting, above which an individual is unable to maintain a standard core temperature, indicating severe heat stress. It is shown here why this state of severe heat stress cannot be predicted using the wet-bulb temperature. Instead, it is shown that the recently extended heat index model can explain nearly all of the variance in the observed critical combinations of temperature and humidity, and can be used to calculate fatal combinations.

59 BASIC BIOLOGICAL SCIENCES↗

Recent Changes in U.S. Regional Heat Wave Characteristics in Observations and Reanalyses

Abstract Humidity is a key determinant of heat wave impacts, but studies investigating changes in extreme heat events have not differentiated between events characterized by high temperatures and those characterized by simultaneously elevated temperature and humidity. The authors present a framework, using air temperature (T) and equivalent temperature (TE; a measure combining temperature and specific humidity), to examine changes in local percentile-based extreme heat events characterized by high temperature (T only) and those with high temperature and humidity (T-and-TE events). Application to one observational dataset (PRISM), four reanalysis products (1981–2015), and seven U.S. regions reveals widespread changes in heat wave characteristics over the 35-yr period. Agreement among the datasets employed on several heat wave metrics suggests that many of the findings are robust. With the exception of the northern plains region, all regions experienced increases in both T-only and T-and-TE heat wave day (HWD) frequency in each of the reanalyses. In the northern plains, all datasets have negative trends in T-only HWD frequency and positive trends in T-and-TE HWD frequency. Trends in HWD frequency were generally accompanied by changes in the spatial footprint in heat wave conditions. Temperature has increased significantly during T-only HWDs in the western regions, while increases in TE during T-and-TE HWDs have occurred in the central United States and Northeast region. These findings suggest that equivalent temperature provides an alternative perspective on the evolution of regional heat wave climatology. Studies considering changes in regional heat wave impacts should carefully consider the role of atmospheric moisture.

Schoof, J. T.↗