Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Performance of an Array of 6 X 6 X 20 mm3 Virtual Frisch-Grid CdZnTe Detectors With A Waveform Sampling Readout System

Arrays of CdZnTe (CZT) bars with high spatial and energy resolution are an enabling technology for future space missions, such as the image plane detector of the Galactic Explorer with a Coded Aperture Mask Compton Telescope (GECCO). GECCO will explore the medium-energy (100 keV – 10 MeV) gamma-ray sky, which is among the least covered windows to the Universe with a massive potential for discovery. We have integrated an array of 6x6x20 mm3 virtual Frisch-grid (VFG) CZT detectors, measuring signals from the cathodes, anodes, and pads on each of the four sides of each bar. The VFG CZT detector is read out with an IDEAS GDS-100 waveform sampling readout system to optimize the signal processing and event reconstruction. We evaluated the energy and position resolution of the integrated VFG CZT array with a 137Cs source and successfully demonstrated better than 1% energy resolution and finer than 1 mm position resolution at 662 keV. Furthermore, we carried out a beam test at the High Intensity Gamma-ray Source (HIGS) at Duke University to investigate the performance of the system for higher energy gamma-rays. Together with the basic performance obtained from the 137Cs source, we present here those results from the beam test with various gamma-ray energies up to 8 MeV.

Makoto Sasaki↗

Hybrid analog/digital, large format, photon counting detectors for astronomy

The development of a new microchannel plate photon-counting detector with an analog readout method based on a resistive anode is reported. This detector exhibits extremely high, stable electron gains of 10 to the 8th. At this gain, the spatial resolution is no longer primarily limited by the noise of the resistive anode, so that digital methods of readout, such as discrete conductors, lose their advantage. These detectors can be readily scaled to 40 mm and 70 mm formats to match plate scales of 2-m (and larger) telescopes. New, high speed digital electronics fully exploit the high spatial and time resolution made possible by gains of this level. Analysis of the theoretical performance of this detector shows that the major limitation to the spatial resolution is the proximity focus of the photocathode and the first microchannel plate. The detector has been mated to an echelle spectrograph developed.

Crocker, J.↗

Adaptive Numerical Dissipative Control in High Order Schemes for Multi-D Non-Ideal MHD

The goal is to extend our adaptive numerical dissipation control in high order filter schemes and our new divergence-free methods for ideal MHD to non-ideal MHD that include viscosity and resistivity. The key idea consists of automatic detection of different flow features as distinct sensors to signal the appropriate type and amount of numerical dissipation/filter where needed and leave the rest of the region free of numerical dissipation contamination. These scheme-independent detectors are capable of distinguishing shocks/shears, flame sheets, turbulent fluctuations and spurious high-frequency oscillations. The detection algorithm is based on an artificial compression method (ACM) (for shocks/shears), and redundant multi-resolution wavelets (WAV) (for the above types of flow feature). These filter approaches also provide a natural and efficient way for the minimization of Div(B) numerical error. The filter scheme consists of spatially sixth order or higher non-dissipative spatial difference operators as the base scheme for the inviscid flux derivatives. If necessary, a small amount of high order linear dissipation is used to remove spurious high frequency oscillations. For example, an eighth-order centered linear dissipation (AD8) might be included in conjunction with a spatially sixth-order base scheme. The inviscid difference operator is applied twice for the viscous flux derivatives. After the completion of a full time step of the base scheme step, the solution is adaptively filtered by the product of a 'flow detector' and the 'nonlinear dissipative portion' of a high-resolution shock-capturing scheme. In addition, the scheme independent wavelet flow detector can be used in conjunction with spatially compact, spectral or spectral element type of base schemes. The ACM and wavelet filter schemes using the dissipative portion of a second-order shock-capturing scheme with sixth-order spatial central base scheme for both the inviscid and viscous MHD flux derivatives and a fourth-order Runge-Kutta method are denoted.

Yee, H. C.↗

AXAF/Chandra Capabilities

I will show some examples of what can be done with AXAF/Chandra, whose mirror has a subarcsecond angular resolution and whose detectors include Charge-Coupled Devices (CCDs) and microchannel plates with available high spectral resolution gratings.

Markevitch, M.↗

A mercuric iodide detector system for X-ray astronomy. I - Design considerations and predictions of background and sensitivity

Since the discovery of Sco X-1 initiated X-ray astronomy in 1962, this science has progressed in connection with the placement of X-ray photon detectors above the atmosphere by means of rockets, balloons, and satellites. In the last few years, studies have been conducted regarding the use of mercuric iodide (HgI2) as room temperature X-ray detector for applications in hard X-ray astronomy. These detectors combine a high quantum efficiency with good energy resolution. The sensitivity of an astronomical X-ray telescope is discussed, and a description is presented of a specific design accepted for the HDXT to be flown on Spacelab. Attention is given to predictions of the background counting rate of the detector assembly in this design, taking into account the results of a Monte Carlo simulation of the detector assembly in the radiation environment at balloon altitudes (40 km).

Ricker, G. R.↗

The Design and Performance of the 384: Element Submillimeter Detector Array for SHARC II

We report on the performance of the SHARC II detector, a 12 x 32 array of ion implanted Si pop-up bolometers. This 384 element detector array was built as a prototype for the High Angular Resolution Widefield Camera (HAWC) for the Stratospheric Observatory for Infrared Astronomy (SOFIA). We will discuss the design process, the characterization of the detectors, and the performance of the array in the SHARC II instrument. SHARC II is now a facility instrument on the Caltech Submillimeter Observatory, providing background-limited imaging at 350 and 450 microns.

Moseley, Samuel H.↗

Monolithic Isolated Single-Mode Ring Laser

MISER uses four-sided ring to lase nonreciprocally. Laser concept provides very-compact, efficient, and stable source of coherent radiation. Lasers of single, very-stable frequency desirable for number of purposes. Frequency stability makes possible coherent detection of laser radiation with low-bandwidth detector, useful for communications. Allows very-high-resolution spectroscopy. Any application where desired to use laser in way microwaves used traditionally enhanced if frequency very stable.

Kane, T. J.↗

High resolution diffraction imaging of crystals grown in microgravity and closely related terrestrial crystals

Irregularities found in three crystals grown in space, in four crystals grown entirely on the ground were examined and compared. Irregularities were observed in mercuric iodide, lead tin telluride, triglycine sulfate, and gallium arsenide by high resolution synchrotron x radiation diffraction imaging. Radiation detectors made from mercuric iodide crystals grown in microgravity were reported to perform far better than conventional detectors grown from the same material under full gravity. Effort is now underway to reproduce these 'space' crystals, optimize their properties, and extend comparable superiority to other types of materials.

Steiner, B.↗

Determination of (C-12)/(C-13) in the interstellar medium toward Zeta Ophiuchi and Xi Persei

The Lick Observatory Reticon (LOR) data presented in Hawkins et al. (1985) are reanalyzed in order to determine the cause of the significant discrepancy in (C-12)/(C-13) isotope ratios determined on the basis of observations of this isotope in the interstellar medium toward Zeta Ophiuchi and Xi Persei. A new set of Lick Observatory observations toward Zeta Oph are obtained using a CCD detector. The KPNO coude feed echelle spectrograph and a CCD detector are used to carry out high-resolution, high SNR ratio observations toward Zeta Oph and Xi Per. The LOR results for Zeta Oph are uncertain, ranging to 40 to 60, owing to the error in continuum placement. The KPNO results toward Zeta Oph are (C-12)H/(C-13)H(+)(0, 0) = 63 +/- 8, (C-12)H(+)/(C-13)H(+)(1, 0) = 67 +/- 19, and (C-12)N/(C-13)N = 100 + 88/- 33. Toward Xi Per, the KPNO measurements yield (C-12)H(+)/(C-13)H(+) = 49 +/- 15 from the 4232-A band, and a lower limit of 45 from the 3957-A observations.

Hawkins, Isabel↗

Undersampling Correction for Array Detector-Based Satellite Spectrometers

Array detector-based instruments are now fundamental to measurements of ozone and other atmospheric trace gases from space in the ultraviolet, visible, and infrared. The present generation of such instruments suffers, to a greater or lesser degree, from undersampling of the spectra, leading to difficulties in the analysis of atmospheric radiances. We provide extended analysis of the undersampling suffered by modem satellite spectrometers, which include Global Ozone Monitoring Experiment (GOME), Scanning Imaging Absorption Spectrometer for Atmospheric Chartography (SCIAMACHY), Ozone Monitoring Instrument (OMI), and Ozone Mapping and Profiler Suite (OMPS). The analysis includes basic undersampling, the effects of binning into separate detector pixels, and the application of high-resolution Fraunhofer spectral data to correct for undersampling in many useful cases.

Chance, Kelly↗

Imaging at soft X-ray wavelengths with high-gain microchannel plate detector systems

Multianode microchannel array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 mm are now under evaluation at visible, UV and soft X-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 mm are under development for use in the NASA Goddard Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with Cs I photocathodes can provide a high-resolution imaging capability at EUV and soft X-ray wavelengths and can deliver a maximum count rate from each array in excess of 10 to the 6th counts/s. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode of operation, and performance characteristics of the MAMA detectors are described, and the program for the development of the very-large-format detectors is outlined.

Timothy, J. Gethyn↗

Microscope Would Image X and Gamma Rays

Microscope contains Bragg-reflecting, grazing-incidence reflectors, filter wheel, and detector. Multiple nested coaxial pairs of reflectors used to form images simultaneously at multiple wavelengths. Collects and focuses radiation to produce images with moderate spectral resolution and high spatial resolution. Enables use of smaller, cheaper, better-shielded detectors. Combination of features provides new information of unprecedented value in several fields of research; probing fine structures of pulsed plasmas, investigating minute variations in structures of material specimens penetrated only by hard-x or gamma rays, or in producing maps of distributions of radioisotopes in biological specimens.

Hoover, Richard B.↗

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Modeling Charge Collection in Detector Arrays

A detector array charge collection model has been developed for use as an engineering tool to aid in the design of optical sensor missions for operation in the space radiation environment. This model is an enhancement of the prototype array charge collection model that was developed for the Next Generation Space Telescope (NGST) program. The primary enhancements were accounting for drift-assisted diffusion by Monte Carlo modeling techniques and implementing the modeling approaches in a windows-based code. The modeling is concerned with integrated charge collection within discrete pixels in the focal plane array (FPA), with high fidelity spatial resolution. It is applicable to all detector geometries including monolithc charge coupled devices (CCDs), Active Pixel Sensors (APS) and hybrid FPA geometries based on a detector array bump-bonded to a readout integrated circuit (ROIC).

Hardage, Donna↗

Synthetic Foveal Imaging Technology

Synthetic Foveal imaging Technology (SyFT) is an emerging discipline of image capture and image-data processing that offers the prospect of greatly increased capabilities for real-time processing of large, high-resolution images (including mosaic images) for such purposes as automated recognition and tracking of moving objects of interest. SyFT offers a solution to the image-data processing problem arising from the proposed development of gigapixel mosaic focal-plane image-detector assemblies for very wide field-of-view imaging with high resolution for detecting and tracking sparse objects or events within narrow subfields of view. In order to identify and track the objects or events without the means of dynamic adaptation to be afforded by SyFT, it would be necessary to post-process data from an image-data space consisting of terabytes of data. Such post-processing would be time-consuming and, as a consequence, could result in missing significant events that could not be observed at all due to the time evolution of such events or could not be observed at required levels of fidelity without such real-time adaptations as adjusting focal-plane operating conditions or aiming of the focal plane in different directions to track such events. The basic concept of foveal imaging is straightforward: In imitation of a natural eye, a foveal-vision image sensor is designed to offer higher resolution in a small region of interest (ROI) within its field of view. Foveal vision reduces the amount of unwanted information that must be transferred from the image sensor to external image-data-processing circuitry. The aforementioned basic concept is not new in itself: indeed, image sensors based on these concepts have been described in several previous NASA Tech Briefs articles. Active-pixel integrated-circuit image sensors that can be programmed in real time to effect foveal artificial vision on demand are one such example. What is new in SyFT is a synergistic combination of recent advances in foveal imaging, computing, and related fields, along with a generalization of the basic foveal-vision concept to admit a synthetic fovea that is not restricted to one contiguous region of an image.

Hoenk, Michael↗

A space qualified thermal imaging system using a Pt Si detector array

EDO Corporation, Barnes Engineering Division designed and constructed a high resolution thermal imaging system on contract to Lockheed for use in the SDI Star Lab. This employs a Pt Si CCD array which is sensitive in the spectral range of 3 to 5 microns. Star Lab will be flown in the Shuttle bay and consists basically of a large, reflecting, tracking telescope with associated sensors and electronics. The thermal imaging system is designed to operate in the focal plane of this telescope. The configuration of the system is illustrated. The telescope provides a collimated beam output which is focussed onto the detector array by a silicon objective lens. The detector array subtends a field of view of 1.6 degrees x 1.22 degrees. A beam switching mirror permits bypassing the large telescope to give a field of 4 degrees x 3 degrees. Two 8 position filter wheels are provided, and background radiation is minimized by Narcissus mirrors. The detector is cooled with a Joule-Thompson cryostat fed from a high pressure supply tank. This was selected instead of a more convenient closed-cycle system because of concern with vibration. The latter may couple into the extremely critical Starlab tracking telescope. The electronics produce a digitized video signal for recording. Offset and responsivity correction factors are stored for all pixels and these corrections are made to the digitized output in real time.

Astheimer, Robert W.↗

A comprehensive study of the X-ray structure and spectrum of IC 443

This paper presents the results of a comprehensive study of the X-ray emission from the supernova remnant IC 443, using the solid state spectrometer, IPC, and high-resolution images of the Einstein Observatory, and the medium-energy detector of the HEAO 1 A-2 experiment. A soft X-ray appearance was observed, highly atypical of a supernova remnant in the adiabatic phase, with little correlation between X-ray and optical or radio features. The best-fit models of the low-energy X-ray spectrum of the brightest area of the remnant suggest either that the remnant has not yet attained ionization equilibrium or that the X-rays arise in a multiphase medium. Pronounced soft X-ray spectral differences across the remnant are accounted for by variations in absorption by an intervening molecular cloud. The analysis suggests that, despite the atypical X-ray appearance, the X-ray emission in IC 443 is probably confined to a thin (0.1 pc) shell.

Petre, R.↗