Search NASA⌕ Search

SEARCH · Search NASA

Results for “high resolution detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

Design of High-Performance Photon-Number-Resolving Photodetectors Based on Coherently Interacting Nanoscale Elements

A number of applications in basic science and technology would benefit from high-fidelity photon-number-resolving photodetectors. While some recent experimental progress has been made in this direction, the requirements for true photon number resolution are stringent, and no design currently exists that achieves this goal. Here we employ techniques from fundamental quantum optics to demonstrate that detectors composed of subwavelength elements interacting collectively with the photon field can achieve high-performance photon number resolution. We propose a new design that simultaneously achieves photon number resolution, high efficiency, low jitter, low dark counts, and high count rate. Finally, we discuss specific systems that satisfy the design requirements, pointing to the important role of nanoscale device elements.

47 OTHER INSTRUMENTATION↗

Neutrino Oscillations at the NOvA Experiment

NOvA is a long-baseline neutrino oscillation experiment located at Fermi National Accelerator Laboratory (Fermilab) in Batavia, IL, USA. Its main goal is to extract neutrino oscillation parameters by examining the disappearance of $\nu_\mu \ (\bar{\nu}_\mu)$ and the appearance of $\nu_e \ (\bar{\nu}_e)$ at its far detector. The experiment uses the NuMI beamline at Fermilab, which delivers a high-purity neutrino and antineutrino beam. NOvA consists of two functionally similar, high-resolution liquid scintillator tracking calorimeters, both placed 14.6 milliradians off the beam axis. The near detector, positioned 100 m underground and 1 km from the beam's origin, captures unoscillated $\nu_\mu (\bar{\nu}_\mu)$ and instrinsic beam $\nu_e \ (\bar{\nu}_e)$ events. The far detector, located 810 km away from the beam source in Ash River, Minnesota, measures both unoscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and those that have oscillated into $\nu_\mu \ (\bar{\nu}_\mu) \to \nu_e \ (\bar{\nu}_e)$. This poster will cover the latest results on three-flavor neutrino oscillation parameters, derived from an exposure of neutrino beam of $26.60 \times 10^{20}$ POT and anti-neutrino beam exposure of $12.50\times 10^{20}$ POT including an additional low energy $\nu_e$ sample.

Singh, Ishwar [Delhi U.]↗

Monte Carlo Modeling and Design of Photon Energy Attenuation Layers for >10× Quantum Yield Enhancement in Si-Based Hard X-ray Detectors

High-energy (>20 keV) X-ray photon detection at high quantum yield, high spatial resolution, and short response time has long been an important area of study in physics. Scintillation is a prevalent method but limited in various ways. Directly detecting high-energy X-ray photons has been a challenge to this day, mainly due to low photon-to-photoelectron conversion efficiencies. Commercially available state-of-the-art Si direct detection products such as the Si charge-coupled device (CCD) are inefficient for >10 keV photons. Here, we present Monte Carlo simulation results and analyses to introduce a highly effective yet simple high-energy X-ray detection concept with significantly enhanced photon-to-electron conversion efficiencies composed of two layers: a top high-Z photon energy attenuation layer (PAL) and a bottom Si detector. We use the principle of photon energy down conversion, where high-energy X-ray photon energies are attenuated down to ≤10 keV via inelastic scattering suitable for efficient photoelectric absorption by Si. Our Monte Carlo simulation results demonstrate that a 10–30× increase in quantum yield can be achieved using PbTe PAL on Si, potentially advancing high-resolution, high-efficiency X-ray detection using PAL-enhanced Si CMOS image sensors.

47 OTHER INSTRUMENTATION↗

High-resolution x-ray radiography with Fresnel zone plates on the University of Rochester’s OMEGA Laser Systems

Experiments performed at the Laboratory for Laser Energetics with a continuous-wave (cw) x-ray source and on the OMEGA and OMEGA EP Laser Systems have utilized a Fresnel zone plate (FZP) to obtain x-ray images with a spatial resolution as small as ~1.5 μm. Such FZP images were obtained with a charge-coupled device or a framing camera at energies ranging from 4.5 keV to 6.7 keV using x-ray line emission from both the cw source and high-intensity, laser-beam–illuminated metal foils. In all cases, the resolution test results are determined from patterns and grids backlit by these sources. Here, the resolutions obtained are shown to be due to a combination of the spectral content of the x-ray sources and detector resolution limited by the magnification of the images (14× to 22×). High-speed framing cameras were used to obtain FZP images with frame times as short as ~30 ps. Double-shell implosions on OMEGA were backlit by laser-irradiated Fe foils, thus obtaining a framing-camera–limited, FZP-image resolution of ~3 μm–4 μm.

47 OTHER INSTRUMENTATION↗

Improving ICARUS track reconstruction algorithms

The ICARUS experiment is part of the Short-Baseline Neutrino program at Fermilab. Its primary objective is to explore the possible existence of sterile neutrinos in the O(1 eV) mass range and to clarify the anomalies observed in the Liquid Scintillator Neutrino Detector and MiniBooNE experiments. The ICARUS-T600 detector is a Liquid Argon Time Projection Chamber, capable of producing high-resolution 3D images and precise calorimetric measurements of ionizing particles. This technology allows for a detailed study of neutrino interactions across a broad energy range, from a few keV to several hundred GeV. The track reconstruction is achieved through a software framework that applies a series of pattern recognition algorithms, transforming raw detector signals into fully reconstructed event topologies. This process involves identifying interaction vertices, particle tracks, and electromagnetic showers within the TPC. However, in certain cases, these algorithms may mistakenly break a single particle track into several shorter segments, interpreting each as a distinct particle. Since track length is used to estimate the particle's energy, such fragmentation can result in an energy underestimation of several hundred MeV. Furthermore, when a track is split into multiple segments, the particle identification (which relies on analyzing the energy loss as a function of the residual range) may fail, potentially leading to the loss of the entire event. To mitigate this problem, we have developed a dedicated algorithm designed to identify and reconnect (“stitch”) the tracks that were erroneously divided into multiple segments.

Ricci, Alessandro Maria [Pisa U.; INFN, Pisa] (ORC↗

Lithium source for focused ion beam implantation and analysis

In this work, we present a new Li source for focused ion beam applications. Based on an AuSi eutectic alloy, Li is added as an impurity to minimize effects from degradation when exposed to air. We show the source is stable over the course of an hour and spot sizes ≲10 nm can be achieved. The Li beam can achieve hundreds of nanometer ranges in semiconductors with minimal damage being generated along the path length. The source performance is evaluated through a high-resolution ion beam induced charge collection experiment on an Si-based detector. Further application of the source for ion beam analysis is numerically explored; the example investigated is based on probing a semiconductor heterostructure through a Rutherford backscattering experiment, where the Li beam can reveal information that is inaccessible with either low energy or high energy He projectiles used as probes.

36 MATERIALS SCIENCE↗

LBNF/DUNE Cryostats and Cryogenics Infrastructure for the DUNE Far Detector (Design Report)

DUNE is an international experiment dedicated to addressing some of the questions at the forefront of particle physics and astrophysics, including the mystifying preponderance of matter over antimatter in the early universe. The dual-site experiment will employ an intense neutrino beam focused on both a near detector and a cryogenic far detector. The DUNE far detector implements liquid argon time-projection chamber (LArTPC) technology, and combines many tens-of-kilotons of fiducial mass with sub-centimeter spatial resolution to collect neutrino events and image them with high precision. Given its size, this detector will be implemented as a set of up to four modules, each of which will require its own cryostat that will contain approximately 17.5 metric kilotons of ultra-pure liquid argon (LAr). The cryogenics infrastructure to support the detector modules includes systems to receive, transfer, store, purify, and maintain the LAr. This design report describes the cryostats and the cryogenics infrastructure required for the first two detector modules; this infrastructure is designed to support expansion to up to four far detector modules.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum Dot Based Solid-State Radiation Detectors

The detection and accurate identification of nuclear material is critical to the advancement of national security, medical technology, and environmental prosperity. The gold standard solid-state detector HPGe, suffers from high manufacturing costs and the need to operate at cryogenic temperatures to ensure reliable energy resolution. The other most common solid-state detector, cadmium zinc telluride (CZT), has the ability to operate at room temperature, but the grow process results in impurities decreasing performance. In this paper we have developed a continuous flow synthesis able to mass produce targeted size cadmium selenide quantum dots. The implementation of these QDs in QD/MEH-PPV composites has the ability to rival HPGe energy resolution at room temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GPS-Based Gamma Survey for Characterizing and Decommissioning NORM Sites - 20389

Gamma survey techniques are an especially powerful decommissioning tool at naturally occurring radioactive material (NORM) sites due to both the low cost to obtain data over a large spatial scale and the abundance of gamma emitters in the uranium and thorium decay series. Gamma surveys are executed by coupling a detector - most often a sodium iodide crystal - to a global positioning system (GPS), then reporting a location and gross gamma reading coincidentally to a data logger. Systems may be carried by workers or mounted to a car, all-terrain vehicle, or unmanned aerial system (UAS). The resulting data set provides a high-resolution but low precision map of the gamma radiation field over the area surveyed. Frequently this map is also correlated to soil concentrations of NORM radionuclides (most often, Ra-226) and/or exposure rate. Gamma survey parameters such as movement speed, transect spacing, and data logging frequency define the spatial resolution of the resulting surface, and can be optimized depending on the desired survey sensitivity. This paper examines gamma survey as a tool for decommissioning NORM sites and provides an overview of current gamma survey technology designed to improve the efficiency and effectiveness of the decommissioning process. Topics to be discussed in the paper include: - An overview of gamma survey systems, and the utility of different delivery vehicles depending on desired cost, desired spatial resolution, and site topography. - The influence of physical detector characteristics on detection sensitivity and survey planning. - The tradeoff between high-resolution and large spatial extent, but inherently uncertain data, and low-resolution, low spatial extent, but highly certain data, as well as the specific utility of each of these types of data during NORM facility decommissioning. - Confounding variables that may limit the utility of gamma survey at some sites (e.g., radon gas and spatial heterogeneity / hot spots), and methods to plan for and control these conditions. Results show that the confounding variables, such as radon and data output can greatly influence the overall data quality associated with the decommissioning process. In addition, the use of real-time and aerial survey platforms provides a method for ensuring proper spatial extent of the data. When applied thoughtfully, gamma survey is a powerful tool for detecting NORM radionuclides in the environment and a cost-effective technique for identifying areas requiring remediation. However, entities performing or using gamma survey as a decommissioning tool must be aware of both its advantages and its limitations before basing remediation or regulatory action on gamma survey results. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterizing defect structures in AM steel using direct electron detection EBSD

The mechanical properties of additive and traditionally manufactured alloys are largely dependent on the characteristics and distribution of dislocation cell networks that develop during the fabrication process. This work demonstrates the ability to quantitatively characterize these dislocation structures by high angular resolution electron backscatter diffraction analysis using a direct electron detector. The defect structures are characterized in terms of the geometrically necessary dislocation density and the associated Burgers vector and line direction. Furthermore, the results are discussed in terms of potential defect formation mechanisms.

36 MATERIALS SCIENCE↗

Decay of the proton-unbound superradiant state in 13 N

Here, the 12 C ( 3 He, 𝑑)⁢ 13 N* reaction is studied in an experiment with a high-resolution magnetic spectrograph, in coincidence with protons detected in silicon detectors near the target. This allows for the observation of angular correlation patterns between the proton transfer and proton decays from populated unbound resonances. A formalism describing the spin polarization of direct reactions is developed to analyze these correlations, and is verified on the known directionally asymmetric decay distributions arising from parity mixing in the 13 N ⁡($\frac{3}{2}$ − , $\frac{5}{2}$ + ) doublet. The same formalism is used to study the decays from the continuum-aligned, broad 3/2 + resonance at 7.9 MeV excitation energy, which arises from superradiant coupling. The observed asymmetric angular correlation patterns are approximately reproduced by adding an “artificial” 3/2 − resonance with strength equal to that of the reaction formalism. This parity-mixing approach serves as a first approximation to a more advanced reaction model of rapid reaction and decay sequences.

13N↗

Detector pixel calibration of time-of-flight neutron diffractometers accelerated by machine learning

Modern time-of-flight neutron diffractometers at spallation neutron source are equipped with two dimensional detectors with fine pixelations. The flight path of neutrons from the moderator to the sample and to the detector needs to be precisely calibrated at detector pixel level using standard powders so the diffraction data from all the detector pixels can be correctly time-focused to produce high resolution diffraction peaks. The number of pixels can reach to millions which makes a single-pixel calibration process time-consuming, or even impossible, with conventional fitting routine. Here we presented a machine learning aided calibration process via a “training and predict” process by training machine learning models with the relations between the individual pixel time-of-flight diffraction pattern and fitted diffraction constant. The training models take a portion of the available pixels to predict the diffraction constants precisely and rapidly for massive pixel diffraction patterns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECAL Calibration and Energy Resolution for a 10TeV Detector Geometry

In the pursuit of a muon collider operating at ~10 TeV center-of-mass-energy, designing a highly accurate and sensitive detector is crucial. Calorimetry plays a key part in any detector setup, as we rely on our calorimeters for energy reconstruction and particle identification. Therefore, an effective calorimeter must be extremely well-calibrated and achieve excellent resolution. This poster will report on efforts to achieve a comprehensive energy calibration of the electromagnetic calorimeter (ECAL) for our 10 TeV detector design. This calibration is necessary in order to achieve desired energy resolution for reconstructed photons across a wide range of energies (0-1TeV). We report on the challenges introduced by the new location of the solenoid in our latest 10 TeV detector design, the necessity of a calibration strategy that is both energy-dependent and angularly dependent, and the resulting effects on photon energy resolution.

Powers, Rose↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

Measurement of the Higgs boson mass with H → γγ decays in 140 fb –1 of $\sqrt{s}$ = 13 TeV pp collisions with the ATLAS detector

The mass of the Higgs boson is measured in the H→γγ decay channel, exploiting the high resolution of the invariant mass of photon pairs reconstructed from the decays of Higgs bosons produced in proton–proton collisions at a centre-of-mass energy $\sqrt{s}$ = 13 TeV. The dataset was collected between 2015 and 2018 by the ATLAS detector at the Large Hadron Collider, and corresponds to an integrated luminosity of 140 fb –1 . The measured value of the Higgs boson mass is 125.17 ± 0.11(stat.) ± 0.09(syst.) GeV and is based on an improved energy scale calibration for photons, whose impact on the measurement is about four times smaller than in the previous publication. A combination with the corresponding measurement using 7 and 8 TeV pp collision ATLAS data results in a Higgs boson mass measurement of 125.22 ± 0.11(stat.) ± 0.09(syst.) GeV. With an uncertainty of 1.1 per mille, this is currently the most precise measurement of the mass of the Higgs boson from a single decay channel.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗