At least 217 records · Page 12

Low-level processing for real-time image analysis

A system that detects object outlines in television images in real time is described. A high-speed pipeline processor transforms the raw image into an edge map and a microprocessor, which is integrated into the system, clusters the edges, and represents them as chain codes. Image statistics, useful for higher level tasks such as pattern recognition, are computed by the microprocessor. Peak intensity and peak gradient values are extracted within a programmable window and are used for iris and focus control. The algorithms implemented in hardware and the pipeline processor architecture are described. The strategy for partitioning functions in the pipeline was chosen to make the implementation modular. The microprocessor interface allows flexible and adaptive control of the feature extraction process. The software algorithms for clustering edge segments, creating chain codes, and computing image statistics are also discussed. A strategy for real time image analysis that uses this system is given.

Eskenazi, R.↗

Observations of breakup processes of liquid jets using real-time X-ray radiography

To unravel the liquid-jet breakup process in the nondilute region, a newly developed system of real-time X-ray radiography, an advanced digital image processor, and a high-speed video camera were used. Based upon recorded X-ray images, the inner structure of a liquid jet during breakup was observed. The jet divergence angle, jet breakup length, and fraction distributions along the axial and transverse directions of the liquid jets were determined in the near-injector region. Both wall- and free-jet tests were conducted to study the effect of wall friction on the jet breakup process.

Char, J. M.↗

Prospects for Nonlinear Laser Diagnostics in the Jet Noise Laboratory

Two experiments were conducted to test whether optical methods, which rely on laser beam coherence, would be viable for off-body flow measurement in high-density, compressible-flow wind tunnels. These tests measured the effects of large, unsteady density gradients on laser diagnostics like laser-induced thermal acoustics (LITA). The first test was performed in the Low Speed Aeroacoustics Wind Tunnel (LSAWT) of NASA Langley Research Center's Jet Noise Laboratory (JNL). This flow facility consists of a dual-stream jet engine simulator (with electric heat and propane burners) exhausting into a simulated flight stream, reaching Mach numbers up to 0.32. A laser beam transited the LSAWT flow field and was imaged with a high-speed gated camera to measure beam steering and transverse mode distortion. A second, independent test was performed on a smaller laboratory jet (Mach number < 1.2 and mass flow rate < 0.1 kg/sec). In this test, time-averaged LITA velocimetry and thermometry were performed at the jet exit plane, where the effect of unsteady density gradients is observed on the LITA signal. Both experiments show that LITA (and other diagnostics relying on beam overlap or coherence) faces significant hurdles in the high-density, compressible, and turbulent flow environments similar to those of the JNL.

Herring, Gregory C.↗

Revolutionizing Investigation of Unsteady Flow with Pressure-Sensitive Paint

NASA and its Stakeholders are developing increasingly advanced aerospace vehicles. Performing a ground test is a standard method to quantify the loads a vehicle will experience during flight. In order to efficiently design these new advanced aerospace vehicles, more advanced tools are required. A new state-of-the-art technique to measure unsteady aerodynamics is currently being developed using pressure-sensitive paint (PSP), high-speed cameras, and advanced image processing methods. This new technique is capable of acquiring fluctuating pressures up to 20 kHz with continuous spatial resolution which enables direct calculation of unsteady loads. To successfully develop a new capability, a systems perspective must be taken. Recently, a connection was established between the Unitary Plan Wind Tunnel and the NASA Advanced Supercomputer, both located at NASA Ames Research Center. The rapid transfer, processing, and display of high-speed PSP data from the wind tunnel demonstrated the ability to make real-time decisions in order to decrease design cycle time.

PSP↗

Algorithms for High-Speed Noninvasive Eye-Tracking System

Two image-data-processing algorithms are essential to the successful operation of a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. The system was described in High-Speed Noninvasive Eye-Tracking System (NPO-30700) NASA Tech Briefs, Vol. 31, No. 8 (August 2007), page 51. To recapitulate from the cited article: Like prior commercial noninvasive eyetracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Most of the prior commercial noninvasive eyetracking systems rely on standard video cameras, which operate at frame rates of about 30 Hz. Such systems are limited to slow, full-frame operation. The video camera in the present system includes a charge-coupled-device (CCD) image detector plus electronic circuitry capable of implementing an advanced control scheme that effects readout from a small region of interest (ROI), or subwindow, of the full image. Inasmuch as the image features of interest (the cornea and pupil) typically occupy a small part of the camera frame, this ROI capability can be exploited to determine the direction of gaze at a high frame rate by reading out from the ROI that contains the cornea and pupil (but not from the rest of the image) repeatedly. One of the present algorithms exploits the ROI capability. The algorithm takes horizontal row slices and takes advantage of the symmetry of the pupil and cornea circles and of the gray-scale contrasts of the pupil and cornea with respect to other parts of the eye. The algorithm determines which horizontal image slices contain the pupil and cornea, and, on each valid slice, the end coordinates of the pupil and cornea. Information from multiple slices is then combined to robustly locate the centroids of the pupil and cornea images. The other of the two present algorithms is a modified version of an older algorithm for estimating the direction of gaze from the centroids of the pupil and cornea. The modification lies in the use of the coordinates of the centroids, rather than differences between the coordinates of the centroids, in a gaze-mapping equation. The equation locates a gaze point, defined as the intersection of the gaze axis with a surface of interest, which is typically a computer display screen (see figure). The expected advantage of the modification is to make the gaze computation less dependent on some simplifying assumptions that are sometimes not accurate

Talukder, Ashit↗

Experimental Heat Transfer Results and Flow Visualization of Vertical Upflow Boiling in Earth Gravity with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.

flow boiling↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, W. T.↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, B.↗

Real-Time, Holographic, Dynamic Image-Storage Device

Solid-state device developed for high-speed acquisition, dynamic storage, and amplification of three-dimensional holographic images. Holograms generated via four-wave mixing in two or more photorefractive crystals (or subelements of single crystal) to create single-crystal or multicrystal oscillator. Apparatus provides dynamic storage of holographic image of object after electronic shutter closed to turn off object beam. Provides capability to store, amplify, process, and transmit time-varying, two-dimensional, spatial information. Developments include sensors, actuators, and optical computers operating at speeds on order of speed of light. Potential in applications in which need for high-speed acquisition and storage of three-dimensional holographic images.

Montgomery, Raymond C.↗

Digital Image Correlation for Performance Monitoring

Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of non-destructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

Palaviccini, Miguel↗

Applications of Digital Image Processing 11

A new technique, digital image velocimetry, is proposed for the measurement of instantaneous velocity fields of time dependent flows. A time sequence of single-exposure images of seed particles are captured with a high-speed camera, and a finite number of the single-exposure images are sampled within a prescribed period in time. The sampled images are then digitized on an image processor, enhanced, and superimposed to construct an image which is equivalent to a multiple exposure image used in both laser speckle velocimetry and particle image velocimetry. The superimposed image and a single-exposure Image are digitally Fourier transformed for extraction of information on the velocity field. A great enhancement of the dynamic range of the velocity measurement is accomplished through the new technique by manipulating the Fourier transform of both the single-exposure image and the superimposed image. Also the direction of the velocity vector is unequivocally determined. With the use of a high-speed video camera, the whole process from image acquisition to velocity determination can be carried out electronically; thus this technique can be developed into a real-time capability.

Cho, Y. -C.↗

An electronic pan/tilt/zoom camera system

A camera system for omnidirectional image viewing applications that provides pan, tilt, zoom, and rotational orientation within a hemispherical field of view (FOV) using no moving parts was developed. The imaging device is based on the effect that from a fisheye lens, which produces a circular image of an entire hemispherical FOV, can be mathematically corrected using high speed electronic circuitry. An incoming fisheye image from any image acquisition source is captured in memory of the device, a transformation is performed for the viewing region of interest and viewing direction, and a corrected image is output as a video image signal for viewing, recording, or analysis. As a result, this device can accomplish the functions of pan, tilt, rotation, and zoom throughout a hemispherical FOV without the need for any mechanical mechanisms. A programmable transformation processor provides flexible control over viewing situations. Multiple images, each with different image magnifications and pan tilt rotation parameters, can be obtained from a single camera. The image transformation device can provide corrected images at frame rates compatible with RS-170 standard video equipment.

Zimmermann, Steve↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occuring during the readout window.

Lacy, Jeffrey L.↗

High speed multiwire photon camera

An improved multiwire proportional counter camera having particular utility in the field of clinical nuclear medicine imaging. The detector utilizes direct coupled, low impedance, high speed delay lines, the segments of which are capacitor-inductor networks. A pile-up rejection test is provided to reject confused events otherwise caused by multiple ionization events occurring during the readout window.

Lacy, Jeffrey L.↗

Massively parallel information processing systems for space applications

NASA is developing massively parallel systems for ultra high speed processing of digital image data collected by satellite borne instrumentation. Such systems contain thousands of processing elements. Work is underway on the design and fabrication of the 'Massively Parallel Processor', a ground computer containing 16,384 processing elements arranged in a 128 x 128 array. This computer uses existing technology. Advanced work includes the development of semiconductor chips containing thousands of feedthrough paths. Massively parallel image analog to digital conversion technology is also being developed. The goal is to provide compact computers suitable for real-time onboard processing of images.

Schaefer, D. H.↗

Concepts for on-board satellite image registration. Volume 2: IAS prototype performance evaluation standard definition

Problems encountered in testing onboard signal processing hardware designed to achieve radiometric and geometric correction of satellite imaging data are considered. These include obtaining representative image and ancillary data for simulation and the transfer and storage of a large quantity of image data at very high speed. The high resolution, high speed preprocessing of LANDSAT-D imagery is considered.

Daluge, D. R.↗

Neutron and high speed photogrammetric arcjet diagnosis

Two methods for real time internal diagnostics of arcjet engines are described. One method uses cold, thermal, or epithermal neutrons. Cold neutrons are used to detect the presence and location of hydrogenous propellants. Thermal neutrons are used to delineate the edge contours of anode and cathode surfaces and to measure stress/strain. Epithermal neutrons are used to measure temperatures on arcjet surfaces, bulk material temperatures, and point temperatures in bulk materials. It is found that this method, with an exposure time of 10 min, produces at temperature accuracy for W or Re of + or - 2.5 C. The other method uses visible-light high-speed photogrammetry to obtain images of the transient behavior of the arc during start-up and to relate this behavior to electrial supply characteristics such as voltage, current, and ripple.

Stewart, P. A. E.↗