Search NASA⌕ Search

SEARCH · Search NASA

Results for “high temperature sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Sintered Fiber Electrodes

Method proposed to make improved porous electrodes for oxygen pumps, oxygen sensors, high-temperature solid-electrolyte fuel cells, and high-temperature solid-electrolyte electrolysis cells. Electrode made by sintering mat of conducting fibers. Many sintered bonds between intersecting fibers increase electrical conductivity and provide strength, yet allow mat to remain highly porous.

Schroeder, James E.↗

Measured Propagation Characteristics of Coplanar Waveguide on Semi-Insulating 4H-SiC Through 800 K

Wireless sensors for high temperature industrial applications and jet engines require RF transmission lines and RF integrated circuits (RFICs) on wide bandgap semiconductors such as SiC. In this paper, the complex propagation constant of coplanar waveguide fabricated on semiinsulating 4H-SiC has been measured through 813 K. It is shown that the attenuation increases 3.4 dB/cm at 50 GHz as the SiC temperature is increased from 300 K to 813 K. Above 500 K, the major contribution to loss is the decrease in SiC resistivity. The effective permittivity of the same line increases by approximately 5 percent at microwave frequencies and 20 percent at 1 GHz.

Ponchak, George E.↗

Polarization Stability of Amorphous Piezoelectric Polyimides

Amorphous polyimides containing polar functional groups have been synthesized and investigated for potential use as high temperature piezoelectric sensors. The thermal stability of the piezoelectric effect of one polyimide was evaluated as a function of various curing and poling conditions under dynamic and static thermal stimuli. First, the polymer samples were thermally cycled under strain by systematically increasing the maximum temperature from 50 C to 200 C while the piezoelectric strain coefficient was being measured. Second, the samples were isothermally aged at an elevated temperature in air, and the isothermal decay of the remanent polarization was measured at room temperature as a function of time. Both conventional and corona poling methods were evaluated. This material exhibited good thermal stability of the piezoelectric properties up to 100 C.

Park, C.↗

Measured Attenuation of Coplanar Waveguide on 6H, p-type SiC and High Purity Semi-Insulating 4H SiC through 800 K

Wireless sensors for high temperature applications such as oil drilling and mining, automobiles, and jet engine performance monitoring require circuits built on wide bandgap semiconductors. In this paper, the characteristics of microwave transmission lines on 4H-High Purity Semi-Insulating SiC and 6H, p-type SiC is presented as a function of temperature and frequency. It is shown that the attenuation of 6H, p-type substrates is too high for microwave circuits, large leakage current will flow through the substrate, and that unusual attenuation characteristics are due to trapping in the SiC. The 4H-HPSI SiC is shown to have low attenuation and leakage currents over the entire temperature range.

Ponchak, George E.↗

NASA Tech Briefs, October 2010

Topics covered include: Hybrid Architecture Active Wavefront Sensing and Control; Carbon-Nanotube-Based Chemical Gas Sensor; Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials; Graphene-Based Reversible Nano-Switch/Sensor Schottky Diode; Inductive Non-Contact Position Sensor; High-Temperature Surface-Acoustic-Wave Transducer; Grid-Sphere Electrodes for Contact with Ionospheric Plasma; Enabling IP Header Compression in COTS Routers via Frame Relay on a Simplex Link; Ka-Band SiGe Receiver Front-End MMIC for Transponder Applications; Robust Optimization Design Algorithm for High-Frequency TWTs; Optimal and Local Connectivity Between Neuron and Synapse Array in the Quantum Dot/Silicon Brain; Method and Circuit for In-Situ Health Monitoring of Solar Cells in Space; BGen: A UML Behavior Network Generator Tool; Platform for Post-Processing Waveform-Based NDE; Electrochemical Hydrogen Peroxide Generator; Fabrication of Single, Vertically Aligned Carbon Nanotubes in 3D Nanoscale Architectures; Process to Create High-Fidelity Lunar Dust Simulants; Lithium-Ion Electrolytes Containing Phosphorous-Based, Flame-Retardant Additives; InGaP Heterojunction Barrier Solar Cells; Straight-Pore Microfilter with Efficient Regeneration; Determining Shear Stress Distribution in a Laminate; Self-Adjusting Liquid Injectors for Combustors; Handling Qualities Prediction of an F-16XL-Based Reduced Sonic Boom Aircraft; Tele-Robotic ATHLETE Controller for Kinematics - TRACK; Three-Wheel Brush-Wheel Sampler; Heterodyne Interferometer Angle Metrology; Aligning Astronomical Telescopes via Identification of Stars; Generation of Optical Combs in a WGM Resonator from a Bichromatic Pump; Large-Format AlGaN PIN Photodiode Arrays for UV Images; Fiber-Coupled Planar Light-Wave Circuit for Seed Laser Control in High Spectral Resolution Lidar Systems; On Calculating the Zero-Gravity Surface Figure of a Mirror; Optical Modification of Casimir Forces for Improved Function of Micro- and Nano-Scale Devices; Analysis, Simulation, and Verification of Knowledge-Based, Rule-Based, and Expert Systems; Core and Off-Core Processes in Systems Engineering; Digital Reconstruction Supporting Investigation of Mishaps; and Template Matching Approach to Signal Prediction.

Source record↗

High Temperature Monitoring the Height of Condensed Water in Steam Pipes

An in-service health monitoring system is needed for steam pipes to track through their wall the condensation of water. The system is required to measure the height of the condensed water inside the pipe while operating at temperatures that are as high as 250 deg. C. The system needs to be able to make real time measurements while accounting for the effects of cavitation and wavy water surface. For this purpose, ultrasonic wave in pulse-echo configuration was used and reflected signals were acquired and auto-correlated to remove noise from the data and determine the water height. Transmitting and receiving the waves is done by piezoelectric transducers having Curie temperature that is significantly higher than 250 deg. C. Measurements were made at temperatures as high as 250 deg. C and have shown the feasibility of the test method. This manuscript reports the results of this feasibility study.

fluid height monitoring↗

Wireless Seismometer for Venus

Measuring the seismic activity of Venus is critical to understanding its composition and interior dynamics. Because Venus has an average surface temperature of 462 C and the challenge of providing cooling to multiple seismometers, a high temperature, wireless sensor using a wide bandgap semiconductor is an attractive option. This paper presents progress towards a seismometer sensor with wireless capabilities for Venus applications. A variation in inductance of a coil caused by a 1 cm movement of a ferrite probe held in the coil and attached to a balanced leaf-spring seismometer causes a variation of 80 MHz in the transmitted signal from the oscillator sensor system at 420 C, which correlates to a 10 kHz mm sensitivity when the ferrite probe is located at the optimum location in the coil.

seismometer↗

DGEN Aeropropulsion Research Turbofan (DART) Test Plans

This presentation serves as an overview of test plans for an upcoming DGEN Aeropropulsion Research Turbofan (DART) test entry at the NASA GRC AeroAcoustic Propulsion Laboratory (AAPL). The test entry includes: (1) a fan intra-stage velocity field survey, which will be compared to a Computational Fluid Dynamics (CFD) survey of DART, (2) an exploratory noise study of DART with several objectives focused on measurement projection to the far-field, source identification improvements and development of a barrier wall for isolation of various sources, (3) advancement of core/combustor noise research on DART using more extensive engine-mounted instrumentation, and (4) high-temperature pressure sensor technology-readiness-level (TRL) advancement.

Boyle, Devin K.↗

Plans for Upcoming DGEN Aeropropulsion Research Turbofan (DART) Testing

This presentation serves as an overview of test plans for an upcoming DGEN Aeropropulsion Research Turbofan (DART) test entry at the NASA GRC AeroAcoustic Propulsion Laboratory (AAPL). The test entry includes: (1)a fan intra-stage velocity field survey, which will be compared to a Computational Fluid Dynamics (CFD) survey of DART, (2) an exploratory noise study of DART with several objectives focused on measurement projection to the far-field, source identification improvements and development of a barrier wall for isolation of various sources, (3) advancement of core/combustor noise research on DART using more extensive engine-mounted instrumentation, and (4) high-temperature pressure sensor technology-readiness-level (TRL) advancement.

Boyle, Devin K.↗

Isolating Gas Sensor From Pressure And Temperature Effects

Two-stage flow system enables oxygen sensor in system to measure oxygen content of low-pressure, possibly-high-temperature atmosphere in test environment while protecting sensor against possibly high temperature and fluctuations in pressure of atmosphere. Sensor for which flow system designed is zirconium oxide oxygen sensor sampling atmospheres in high-temperature wind tunnels. Also adapted to other gas-analysis instruments that must be isolated from pressure and temperature effects of test environments.

Sprinkle, Danny R.↗

In Situ Guided Wave Structural Health Monitoring System

Aircraft engine rotating equipment operates at high temperatures and stresses. Noninvasive inspection of microcracks in those components poses a challenge for nondestructive evaluation. A low-cost, low-profile, high-temperature ultrasonic guided wave sensor was developed that detects cracks in situ. The transducer design provides nondestructive evaluation of structures and materials. A key feature of the sensor is that it withstands high temperatures and excites strong surface wave energy to inspect surface and subsurface cracks. The sol-gel bismuth titanate-based surface acoustic wave (SAW) sensor can generate efficient SAWs for crack inspection. The sensor is very thin (submillimeter) and can generate surface waves up to 540 C. Finite element analysis of the SAW transducer design was performed to predict the sensor behavior, and experimental studies confirmed the results. The sensor can be implemented on structures of various shapes. With a spray-coating process, the sensor can be applied to the surface of large curvatures. It has minimal effect on airflow or rotating equipment imbalance, and provides good sensitivity.

Zhao, George↗

Integrated Harsh Environment Gas / Temperature Wireless Microwave Acoustic Sensor System for Fossil Energy Applications

There is a significant need for sensors capable of detecting gases, such as H 2 , O 2 , NO x , SO x within harsh environments encountered in power plants, industrial manufacturing, oil and gas exploration, and aerospace applications. This project successfully demonstrated the use of wireless microwave acoustic sensor technology for the detection of gases (H 2 or O 2 ) from ambient temperatures up to 650°C. The work focused on langasite (LGS) based surface acoustic wave resonator (SAWR) sensors as the harsh-environment sensor platform and explored multiple combinations of high-temperature thin films and device structures which were used to increase the sensor platform stability and detection capability at temperatures in the operational range of 150°C to 700°C. Specific material configurations that were investigated include: yttria-stabilized-zirconia (YSZ) decorated with Pt nanoparticles, atomic layer deposited (ALD) Al 2 O 3 , palladium, and Pt/Al 2 O 3 co-deposited electrode alloys. Through the deposition of YSZ at temperatures as high as 850°C and the use of graded alloy concentrations of Pt in the fabrication of the Pt/Al 2 O 3 electrode structures, film stress problems were mitigated, and sensor operation and stability achieved. To test and evaluate SAWR sensor performance for the detection of H 2 and O 2 under the influence of temperature variations, a comprehensive gas sensor control system and test apparatus was created to operate within a laboratory box furnace-controlled environment. In addition to the advancement in thin film materials through the deposition and fabrication techniques mentioned above, the work characterized the performance of sensors containing these films in the presence of oxidizing and reducing gases between 25°C and 700°C. In particular, the work revealed that the exposure of the SAWR sensor surfaces to oxidizing environments significantly improve the sensor response to H 2 , whereas the exposure of the sensor to reducing environments at high temperatures (≈ 500°C) renders the sensor irresponsive to H 2 , requiring sensor surface treatment at high temperatures (above 500°C) to recover the responsiveness to H 2 . The SAWR sensors have been also tested for wireless operation and array operation using multiple orientations to resolve the detection of gases under temperature variations. The work developed at the University of Maine was aided by a collaboration with the NETL Research and Innovation Center, Pittsburgh, PA, where thin film materials and device structures fabricated at UMaine were tested and characterized using NETL gas reactors and surface analysis techniques. SAWR sensors fabricated at UMaine were exposed multiple times to temperatures up to 700°C and H 2 concentrations up to 100% in the NETL facilities to measure the sensor performance. Environetix Technologies Corporation, a UMaine harsh-environment sensor spin-off company, also provided support and assistance in sensor system testing and implementation. The sensor small size and configuration allows flexible sensor placement and embedding of multiple sensor arrays into a variety of components within power systems and other aerospace or industrial settings that need to be interrogated wirelessly. The SAW platform is an attractive option for high-temperature harsh-environment gas sensing applications due to its inherent features, namely small size, capability of battery-free and wireless operation, and cost effective scale production using well-established production techniques from the semiconductor industry. The research findings achieved in this work, particularly advances regarding the fabrication and performance of the SAWR gas sensor platform, can be adapted and transferred to industrial power plants and other harsh environments.

01 COAL, LIGNITE, AND PEAT↗

A surface acoustic wave hydrogen sensor with tin doped indium oxide layers for intermediate temperatures

We report high temperature surface acoustic wave (SAW) gas sensors with conducting sensing layers require tuning of the sheet conductivity for optimal response. Conducting metal oxides are attractive sensing materials for their tunable electronic properties and high thermal stability, amongst others. Here, we have investigated the application of indium oxide (IO) and indium tin oxide (ITO) films on langasite (LGS)-based SAW reflective delay line sensor devices for monitoring hydrogen at 350 °C. Specifically, we modeled the effect of the IO and ITO sensing layer thickness on the wave velocity, attenuation, and effective electromechanical coefficient. This was followed by an experimental demonstration of tuning of the ITO film sheet conductivity by controlling the dopant concentration and yielding an improvement in the sensor sensitivity. The current study provides a pathway towards the development of conductivity-based sensing layers for high temperature SAW gas sensors with improved sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

The goal of this work was to investigate the in-core performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-core instrumentation. We fabricated clad sapphire optical fibers and evaluated the distributed sensing performance of these sensors via optical backscatter reflectometry under high fluence and combined radiation and temperature effects. A series of irradiations was completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine the operational limits of these sensors. (1) Objective 1: Fabricate sapphire optical fiber sensors. (2) Objective 2: Evaluate the clad sapphire fiber to verify single-mode behavior and determine and characterize the light modes supported by optical fibers. (3) Objective 3: Characterize the in-core temperature sensing of sapphire optical fiber, as well as the combined temperature and irradiation effects. (4) Objective 4: Evaluate the lifetime and performance of the sensor under irradiation to high neutron fluence. Objectives 1, 2, and 3 were completed during the first 2 years of the project. Due to the Covid pandemic, Objective 4, a high-fluence irradiation performed at the Massachusetts Institute of Technology Research Reactor (MITR), was delayed, as partner facilities were subject to mandatory shutdowns and required a 1 year, no-cost extension. This irradiation was eventually completed on December 12, 2022. This work indicates that sapphire optical fiber sensors may be a solution for ultra-high-temperature applications in which traditional silica optical fibers are prone to fail. Sapphire sensors are potentially suitable for experiments featuring temperatures above 700°C for long periods of time, or for any length of time above 1000°C. Experiments featuring a low total fluence, such as irradiations conducted in the Transient Reactor Test (TREAT) facility, also represent good applications for sapphire optical sensors. Additional work is required to characterize the sapphire fiber cladding performance, which falls outside the scope of this project, as well as the effects of high temperatures on the response of the fiber. A comprehensive material study is recommended as future work to evaluate the attenuation in sapphire under irradiation, and how that attenuation changes with irradiation temperature. The drift and attenuation in the fiber at temperatures of up to 1600°C and a total fluence of up to 2.9 x 10 17 n/cm 2 was minimal, and the fibers returned to baseline after being heated to 1600°C under irradiation. This is promising for the future use of sapphire optical fibers in advanced reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of Microwave Resonant Cavity Transducer. Development of sensor performance model of microwave cavity flow meter for advanced reactor high temperature fluids

High-temperature fluid reactors, such as molten salt cooled reactors (MSCR) and sodium fast reactors (SFR), are a promising advanced reactor option. Measurement of high-temperature fluid process variables, in particular the flow inside the pressure vessel, is a challenging task because of harsh environment, which includes high radiation, high temperature, and contact with highly corrosive coolant fluid. We are investigating a microwave cavity-based transducer for high-temperature fluid flow sensing. This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. A cavity is characterized by its resonant frequencies. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the flow sensor is evaluated with signal sensitivity using COMSOL computer simulations. A right cylinder geometry stainless steel cavity with dimeter of 0.8in was investigated. We choose membrane thickness of 10mil, so that corrosion anticipated to proceed at the rate of 1mil/year in liquid sodium would affect no more than 10% of the membrane. Using the properties of liquid sodium fluid, and stainless-steel material property values at 500oC, we calculate frequency shift for a range of values of fluid velocity from 0.5m/s to 2m/s. Results of computer simulations indicate measurable sensitivity to flow for this cavity design. Following these simulations, we have developed a preliminary design for fabrication of a transducer operating in microwave K-band for proof-of-principle tests.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Silicon Carbide Epitaxial Films Studied by Atomic Force Microscopy

Silicon carbide (SiC) holds great potential as an electronic material because of its wide band gap energy, high breakdown electric field, thermal stability, and resistance to radiation damage. Possible aerospace applications of high-temperature, high-power, or high-radiation SiC electronic devices include sensors, control electronics, and power electronics that can operate at temperatures up to 600 C and beyond. Commercially available SiC devices now include blue light-emitting diodes (LED's) and high-voltage diodes for operation up to 350 C, with other devices under development. At present, morphological defects in epitaxially grown SiC films limit their use in device applications. Research geared toward reducing the number of structural inhomogeneities can benefit from an understanding of the type and nature of problems that cause defects. The Atomic Force Microscope (AFM) has proven to be a useful tool in characterizing defects present on the surface of SiC epitaxial films. The in-house High-Temperature Integrated Electronics and Sensors (HTIES) Program at the NASA Lewis Research Center not only extended the dopant concentration range achievable in epitaxial SiC films, but it reduced the concentration of some types of defects. Advanced structural characterization using the AFM was warranted to identify the type and structure of the remaining film defects and morphological inhomogeneities. The AFM can give quantitative information on surface topography down to molecular scales. Acquired, in part, in support of the Advanced High Temperature Engine Materials Technology Program (HITEMP), the AFM had been used previously to detect partial fiber debonding in composite material cross sections. Atomic force microscopy examination of epitaxial SiC film surfaces revealed molecular-scale details of some unwanted surface features. Growth pits propagating from defects in the substrate, and hillocks due, presumably, to existing screw dislocations in the substrates, were imaged. Away from local defects, step bunching was observed to yield step heights of hundreds of angstroms, with possible implications for the uniformity of dopants incorporated in SiC devices during fabrication. The quantitative topographic data from the AFM allow the relevant defect information to be extracted, such as the size and distribution of step bunching and the Burgers vector of screw dislocations. These atomic force microscopy results have furthered the understanding of the dynamic epitaxial SiC growth process. A model describing the observed hillock step bunching has been proposed. This cooperation between researchers involved in crystal growth, electronic device fabrication, and surface structural characterization is likely to continue as atomic force microscopy is used to improve SiC films for high-temperature electronic devices for NASA's advanced turbine engines and space power devices, as well as for future applications in the automotive industry.

Source record↗