Solar-energy-system performance evaluation: Honeywell OTS 44, Ocmulgee, Georgia

The operation and technical performance of the solar operational test site (OTS 44) are described, based on data collected between April, 1981 and August, 1981. The following topics are discussed: system description, performance assessment, operating energy, energy savings, system maintenance, and conclusions. The solar energy system at OTS 44 is a hydronic heating and cooling system consisting of 5040 square feet of liquid cooled flat plate collectors; a 4000 gallon thermal storage tank; one 25 ton capacity organic Rankine cycle engine assisted water chillers; a forced draft cooling tower; and associated piping, pumps, valves, controls and heat rejection equipment. The solar system has eight basic modes of operation and several combination modes for providing space conditioning and hot water to the building. Data monitored during the 4 months of the operational test period found that the solar system collected 285 MMBtu of thermal energy of the total incident solar energy of 1040 MMBtu and provided 210 MMBtu for cooling and 10 MMBtu for heating and hot water. The net electrical energy saving due to the solar system was approximately 2600 kWh(e), and fossil energy saving was about 20 million Btu (MMBtu).

Mathur, A. K.↗

Solar-Energy System for a Commercial Building--Topeka, Kansas

Report describes a solar-energy system for space heating, cooling and domestic hot water at a 5,600 square-foot (520-square-meter) Topeka, Kansas, commercial building. System is expected to provide 74% of annual cooling load, 47% of heating load, and 95% of domestic hot-water load. System was included in building design to maximize energy conservation.

Source record↗

A Fresnel collector process heat experiment at Capitol Concrete Products

An experiment is planned, conducted and evaluated to determine the feasibility of using a Power Kinetics' Fresnel concentrator to provide process heat in an industrial environment. The plant provides process steam at 50 to 60 psig to two autoclaves for curing masonry blocks. When steam is not required, the plant preheats hot water for later use. A second system is installed at the Jet Propulsion Laboratory parabolic dish test site for hardware validation and experiment control. Experiment design allows for the extrapolation of results to varying demands for steam and hot water, and includes a consideration of some socio-technical factors such as the impact on production scheduling of diurnal variations in energy availability.

Hauger, J. S.↗

Solar-energy heats a transportation test center--Pueblo, Colorado

Petroleum-base, thermal energy transport fluid circulating through 583 square feet of flat-plate solar collectors accumulates majority of energy for space heating and domestic hot-water of large Test Center. Report describes operation, maintenance, and performance of system which is suitable for warehouses and similar buildings. For test period from February 1979 to January 1980, solar-heating fraction was 31 percent, solar hot-water fraction 79 percent.

Source record↗

Solar energy system performance evaluaton: Seasonal report for Solaron-Akron, Akron, Ohio

The operational and thermal performance of the solar energy system by Solaron Corporation is described. The system was designed to provide an 1940 square foot floor area with space heating and domestic hot water for a dual-level single family residence in Akron, Ohio. The solar energy system uses air as the heat transport medium, has a 546 square foot flat plate collector array subsystem, a 270 cubic foot rock thermal storage bin subsystem, a domestic hot water preheat tank, pumps, controls and transport lines. In general, the performance of the Solaron Akron solar energy system was somewhat difficult to assess for the November 1978 through October 1979 time period. The problems relating to the control systems, various solar energy leakages, air flow correction factors and instrumentation cause a significant amount of subjectivity to be involved in the performance assessment for this solar energy system. Had these problems not been present, it is felt that this system would have exhibited a resonably high level of measured performance.

Source record↗

Application of solar energy; Proceedings of the First Southeastern Conference, Huntsville, Ala., March 24-26, 1975

Topics related to architectural and institutional considerations are discussed along with studies of components and subsystems. Subjects in the area of system design and analysis are also explored. Residential and commercial applications are considered, taking into account hot-water usage in a typical single-family residence, solar heating and cooling of mobile homes, aspects of design and performance in the case of a solar heating system using a reflective pyramid optical condenser, solar heating in a Boston school, a performance analysis of solar service hot water systems, comparative performance analyses of three solar heated and cooled buildings, and the use of solar energy in a soybeam processing operation. Applications related to power generation are also examined, giving attention to solar thermal electric power systems and photovoltaic research. Individual items are announced in this issue.

Wu, S. T.↗

Machine Cleans And Degreases Without Toxic Solvents

Appliance uses hot water and biodegradable chemicals to degrease and clean hardware. Spray chamber essentially industrial-scale dishwasher. Front door tilts open, and hardware to be cleaned placed on basket-like tray. During cleaning process, basket-like tray rotates as high-pressure "V" jets deliver steam, hot water, detergent solution, and rust inhibitor as required.

Gurguis, Kamal S.↗

Soluble Organic Matter (SOM) analysis of the Hayabusa2 samples: The first results

The Hayabusa2 spacecraft successfully collected the surface and possible sub-surface materials of the asteroid 162173 Ryugu. Ryugu is a C-type asteroid characterized by a low-albedo surface probably consisting of hydrous minerals and carbonaceous materials. [1] The direct optical and spectral analysis of the returned samples indicates that Ryugu material is dominated by hydrous carbonaceous chondrite-like matter (similar to CI chondrites) [2]. Since carbonaceous chondrites have generally yielded various types of organic matter, the collected Ryugu grains are expected to contain diverse types of organic compounds including bio-related molecules. The occurrence of organic compounds in the Ryugu surface will provide clues to the evolution of prebiotic molecules and their preservations associated with aqueous alteration of the primitive asteroid. The initial analysis of soluble organic matter (SOM) of the Hayabusa2-returned samples has been performed by an international team consisting of 32 members. Because the sample amount available for comprehensive SOM analyses is limited, and because the SOM is expected to be present as a complex mixture of various types of organic compounds with very small concentrations of each compound, high-sensitivity and high-resolution analytical techniques have been developed using carbonaceous meteorites [e.g. 3]. Two aggregate samples of the Ryugu grains (A106 and C107) were allocated for the solvent extractions and bulk carbon (C), hydrogen (H), nitrogen (N), sulfur (S) and oxygen (O) measurements. The A106 sample was collected during the 1st sampling in February 2019 and the C107 sample was collected during the 2nd sampling in July 2019 after the Small Carry Impactor (SCI) operation. They consist mainly of particles smaller than 1 mm in diameter, and each sample mass was 38-39 mg. They were firstly investigated spectroscopically in the near infrared wavelength range by the Stone Team prior to the solvent extractions. Other small grains (A0080 and C0057) were also allocated for this study to investigate the spatial distribution of organic compounds on the sample surface. The extraction and analytical measurements implemented by the SOM Team are summarized in Figure 1. Each powder sample was extracted sequentially with non-polar to polar solvents, i.e., hexane, dichloromethane (DCM), methanol (MeOH) and H2O, for non-targeted analysis to reveal the compound composition. Each solvent extract was analyzed by solution state nuclear magnetic resonance (NMR) spectroscopy [4], Fourier transform- ion cyclotron resonance/mass spectrometry (FT-ICR/MS) with ESI and APPI ionization [5] and by high-resolution mass spectroscopy using Orbitrap MS coupled with nano-liquid chromatography (nanoLC/Orbitrap MS) [6], and using two dimensional gas chromatography/mass spectrometry (GC×GC/MS). The extracted residues were passed to the Chemistry Team for further inorganic element analysis. The other powder sample was subjected to the hot water extraction for amino acid analyses including chiral isomer separation, which was performed by three-dimensional (3D) high-performance liquid chromatography (HPLC) with high-sensitivity fluorescence detection (FD) [7] and by HPLC/FD coupled with quadrupole-time of flight/mass spectrometry (QToF/MS) [8]. After the hot water extraction, the residue was split into two halves. One half was further extracted with hydrochloric acid (HCl) to analyze for amino acids in bound-form. The other half was sequentially extracted with DCM/MeOH (1/1) to analyze semi-polar compounds such as polycyclic aromatic hydrocarbons (PAHs) by GC/MS, followed by further extraction with formic acid to analyze polar heterocyclic compounds, and subsequent extraction with HCl to detect bound-form polar compounds. The extracted residues were passed to the IOM Team for the analysis of insoluble organic matter (IOM). Compound-specific stable isotope analyses will be performed using GC/combustion/isotope ratio mass spectrometry (GC/C/IRMS) if the compound concentration is high enough to enable such an isotopic measurement. All extraction procedures were performed on an ISO 6 (Class 100) clean bench inside an ISO 5 (Class 1000) clean room. Baked serpentine powder was also analyzed as a procedural blank. In situ organic compound analysis with the molecular imaging was performed using desorption electrospray ionization (DESI) equipped with Orbitrap MS [9, 10], followed by spatial imaging of organic compounds using ToF/secondary ion mass spectrometry (ToF/SIMS) [11]. The bulk chemical and isotopic compositions of CNS and HO were determined using nano-elemental analysis/isotope ratio mass spectrometry (nanoEA/IRMS) [12] and EA/pyrolysis/IRMS, respectively. We have identified a variety of indigenous organic compounds in the extracts of both A106 and C107 samples. The Ryugu grains host organic molecules under the high-vacuum and cosmic-ray irradiation environment of the asteroid surface. The analysis of extracted molecules is in progress, and the first results will be presented at the symposium.

Hiroshi Naraoka↗

Study of the application of solar chemical dehumidification system to wind tunnel facilities of NASA Lewis Research Center at Cleveland, Ohio

Energy utilization and cost payback analyses were prepared for proposed modifications. A 50,000 CFM standard compact packaged solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing solar energy and is stored in a storage tank. A steam boiler is provided as a back-up for the solar system. A 50,000 CFM standard compact package solid desiccant dehumidifier utilizing high temperature hot water (HTHW) for desiccant regeneration was added. The HTHW is generated by utilizing a steam boiler and a heat exchanger and is stored in a storage tank.

Source record↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Hybrid Solar Heat Generation Modelling and Cases: Preprint

Renewable thermal energy systems (RTES) harness renewable energy sources to provide services for space heating and cooling, district heating, domestic hot water, and industrial process heat (IPH). The use of low-pressure steam generated by the combustion of fossil fuels is common today to provide process heat for industrial facilities. Solar IPH (SIPH) technologies could economically replace the steam or heat needs at many industrial sites by providing high-temperature pressurized hot water, a heat transfer fluid (HTF) such as synthetic-oil, or direct steam (Kurup and Turchi, 2015). RTES could be hybridized with technology options or combined with the existing heat supply (e.g. fuels), to give options for targeted IPH application and the reduction of fuel consumption. This work has tested hybrid system modelling approaches. Initial results show when a natural gas (NG) burner that feeds an IPH application of 300°C, has both air and NG streams pre-heated with a solar field/RTES exit temperature of 180°C (via an HTF), a 13% NG offset is possible. NG offsets reach up to 26%, when the RTES exit temperatures are at 300°C for a given annual capacity factor of 24%. This can be even higher with addition of thermal energy storage (TES).

43 PARTICLE ACCELERATORS↗

Hybrid Uses of High-Temperature Reservoir Thermal Energy Storage: Lessons Learned from Previous Projects

One of the critical challenges of the green energy transition is resolving the mismatch between energy generation provided by intermittent renewable energy sources such as solar and wind and the demand for energy. There is a need for large amounts of energy storage over a range of time scales (diurnal to seasonal) to better balance energy supply and demand. Subsurface geologic reservoirs provide the potential for storage of hot water that can be retrieved when needed and used for power generation or direct-use applications, such as district heating. It is important to identify potential issues associated with high-temperature reservoir thermal energy storage (HT-RTES) systems so that they can be mitigated, thus reducing the risks of these systems. This paper reviews past experiences from moderate and high-temperature reservoir thermal energy storage (RTES) projects, along with hot water and steam flood enhanced oil recovery (EOR) operations, to identify technical challenges encountered and evaluate possible ways to address them. Some of the identified technical problems that have impacted system performance include: 1) insufficient site characterization that failed to identify reservoir heterogeneity; 2) scaling resulting from precipitation of minerals having retrograde solubility that form with heating of formation brines; 3) corrosion from low pH or high salinity brines; 4) thermal breakthrough between hot and cold wells due to insufficient spacing. Proper design, characterization, construction, and operational practices can help reduce the risk of technical problems that could lead to reduced performance of these thermal energy storage systems.

energy storage↗

Enhancing heat pump water heater performance with embedded phase change materials thermal energy storage: First hour rating improvement and demand response operation

The increasing global emphasis on energy efficiency and sustainability has put heat pump water heaters (HPWHs) in the spotlight as an energy-efficient alternative to traditional water heating systems. However, their widespread adoption is limited by challenges such as insufficient First Hour Rating (FHR), suboptimal control mechanisms, and limited flexibility for demand response operations. Here, to address these limitations, this study proposes an innovative HPWH system integrated with embedded phase change material (PCM)-based thermal energy storage (TES). The research introduces a novel design and control strategy that leverages optimized PCM integration to enhance thermal storage capacity, improve hot water delivery during peak demand, and increase load-shifting potential. A combination of system modeling, performance simulation, and demand response control strategy evaluation was employed to quantify the benefits of PCM integration. Results demonstrate that the proposed PCM-TES HPWH system significantly enhances FHR, with an optimal 7.0 lb. of PCM increasing FHR by over 26 %—from 62 to 78 gal—for a standard 50-gal HPWH. Additionally, under advanced demand response operation using a preheat strategy, the system reduces the percentage of control temperature out-of-band time from 65 % (conventional HPWH) to just 11.6 %, enabling a more stable and efficient hot water supply. This research contributes a novel PCM-embedded HPWH design and control framework that addresses both performance and grid-interactivity challenges. The findings offer a viable pathway to enhancing the operational efficiency, flexibility, and grid responsiveness of residential water heating systems.

Demand response control↗

The development of a residential heating and cooling system using NASA derived technology

A study to determine the technical and economic feasibility of a solar-powered space heating, air-conditioning, and hot water heating system for residential applications is presented. The basic system utilizes a flat-plate solar collector to process incident solar radiation, a thermal energy storage system to store the collected energy for use during night and heavily overcast periods, and an absorption cycle heat pump for actually heating and cooling the residence. In addition, heat from the energy storage system is used to provide domestic hot water. The analyses of the three major components of the system (the solar collector, the energy storage system, and the heat pump package) are discussed and results are presented. The total system analysis is discussed in detail, including the technical performance of the solar-powered system and a cost comparison between the solar-powered system and a conventional system. The projected applicability of the system to different regions of the nation is described.

Oneill, M. J.↗

Advanced metal hydride heat transfer system utilizing an electrochemical hydrogen compressor

An electrochemical heat transfer device for a hot water tank utilizes an electrochemical hydrogen compressor to pump hydrogen into and out of a tank having a metal hydride forming alloy therein. The absorption of hydrogen by the metal hydride forming alloy is exothermic, produces heat, and the desorption of the hydrogen from the metal hydride forming alloy is endothermic and draws heat in. An electrochemical hydrogen compressor may be configured between to tanks and pump hydrogen back and forth to form a heat transfer device, such as a hot water heater. A heat transfer device may be coupled with the tank or may comprise the outer surface of the tank to transfer heat to an object or to the surroundings. A closed loop may be configured having two tanks and one or two electrochemical hydrogen compressors to pump the hydrogen in a loop around the system.

Bahar, Bamdad↗

Optimization of District Heating Network Parameters in Steady-State Operation

Here we examine the modeling, simulation, and optimization of district heating systems, which are widely used for thermal transport using steam or hot water as a carrier. We propose a generalizable framework to specify network models and scenario parameters, and develop an optimization method for evaluating system states including pressures, fluid flowrates, and temperatures throughout the network. The network modeling includes pipes, thermal plants, pumps, and passive or controllable loads as system components. We propose basic models for thermodynamic fluid transport and enforce the balance of physical quantities in steady-state flow over co-located outgoing and return networks. We formulate an optimization problem with steam and hot water as the outgoing and return carriers, as in legacy twentieth century systems. The physical laws and engineering limitations are specified for each component type, and the thermal network flow optimization problem is formulated and solved for a realistic test network under several scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar energy system performance evaluation: Seasonal report for Elcam Tempe Arizona State University, Tempe, Arizona

The solar system, Elcam-Tempe, was designed by Elcam Incorporated, Santa Barbara, California, to supply commercial domestic hot water heating systems to the Agriculture Department residence at Arizona State University. The building is a single story residence located at the agriculture experiment farm of the Arizona State University. The energy system's four modes of operation are described. Electrical energy savings at the site was a net of 5.54 million Btu after the 0.17 million Btu of operating energy required to operate collector loop circulating pump were subtracted. The energy savings due to solar was less than the system's potential. On an average, twice as much hot water could have been used with significant solar energy contribution. The system corrosion and deposits caused by using dissimilar metals in the collector loop was the only problem noted with the Elcam-Tempe system.

Source record↗

Solar energy system performance evaluation: Seasonal report for IBM system 1A, Huntsville, Alabama

The operational and thermal performance of the solar energy system, Sims Prototype System 1A, is described. The system was designed by IBM to provide 50 to 60 percent of the space heating and domestic hot water preheating load to a 2,000 square foot floor space single family residence in the Huntsville area. The load design temperature inside the building was to be maintained at 70 degrees fahrenheit with auxiliary energy for heating supplied by an electric heat pump assisted by an electric resistance strip heater. In general the disappointing operation of this system is attributed to the manner in which it was used. The system was designed for residential application and used to satisfy the demands of an office environment. The differences were: (1) inside temperature was not maintained at 70 F as expected; and (2) hot water usage was much lower than expected. The conclusion is that the solar energy system must be designed for the type of application in which it is used. Misapplication usually will have an adverse affect on system performance.

Source record↗