Search NASA⌕ Search

SEARCH · Search NASA

Results for “image alignment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (Light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction and ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55-m-diameter, proof-of-concept mirror.

Lake, Mark S.↗

A Deployable Primary Mirror for Space Telescopes

NASA Langley Research Center, Composite Optics, Inc., and Nyma/ADF have developed jointly a deployable primary mirror for space telescopes that combines over five years of research on deployment of optical-precision structures and over ten years of development of fabrication techniques for optical-precision composite mirror panels and structures. The deployable mirror is directly applicable to a broad class of non-imaging "lidar" (light direction a nd ranging) telescopes whose figure-error requirements are in the range of one to ten microns RMS. Furthermore, the mirror design can be readily modified to accommodate imaging-quality reflector panels and active panel-alignment control mechanisms for application to imaging telescopes. The present paper: 1) describes the deployable mirror concept; 2) explains the status of the mirror development; and 3) provides some technical specifications for a 2.55- m-diameter, proof-of-concept mirror. Keywords: precision deployment, hinge joint, latch joint, deployable structures, fabrication, space telescopes, optical instruments, microdynamics.

Lake, Mark S.↗

Processed Surface Imagery & Raster Imagery taken onboard TigerShark (U3) UAS

Land-surface orthomosaic imagery derived from the images collected using the Micasense Altum Imager on board the UAS TigerShark (U3) on March 11th, 2021 at an altitude of 2000 ft. The Altum takes images of the land surface across five visible bands and one long wave infrared thermal band. The photogrametry software Agisoft PhotoScan v 1.4 is used to align and stitch the images into a larger composet image using the technique of structure from motion image capture to construct a dense cloud and 3-D model of the surface, which is used to produce a digital elevation model of the terraine surveyed and orthomosaic imagery. This dataset contains the raster calculated orthomosaics of various vegetative indicies, which are used to indicate plant health and land surface characteristics, including Normalized Difference Vegetation Index (NDVI), Green Normalized Difference Vegetation Index (GNDVI), Normalized Difference Water Index (NDWI), surface temperature, and Enhanced_vegetation_index (EVI). These orthomosaics were collected west of the Starkville, MS, airport, and include natural, agricultural, and industrial land coverage. The images have a resolution of 0.2 m/pix.

54 ENVIRONMENTAL SCIENCES↗

An accurate registration technique for distorted images

Accurate registration of International Ultraviolet Explorer (IUE) images is crucial because the variability of the geometrical distortions that are introduced by the SEC-Vidicon cameras ensures that raw science images are never perfectly aligned with the Intensity Transfer Functions (ITFs) (i.e., graded floodlamp exposures that are used to linearize and normalize the camera response). A technique for precisely registering IUE images which uses a cross correlation of the fixed pattern that exists in all raw IUE images is described.

Delapena, Michele↗

Learning Model Structural Uncertainty with Gaussian Processes

The advent of commercially available quantum computers has marked the beginning of quantum computing as a reality. Both quantum gate and annealing computers have been released by major computer hardware companies. In this work, the D-Wave 2XTM quantum annealing computer housed at the NASA Advanced Systems computational facility is investigated to accelerate Machine Learning (ML) for image registration. NASA collects large amounts of images over the globe remotely using space-based monitoring. Images of a fixed areas of the land surface are taken over time. Due to the orbit of the sensors, the viewing angles deviate slightly, and it is necessary to align or register the images precisely to create image time series over the land surface. Unaligned images can lead to substantial analysis errors. These time-series are then used in modeling Earth Systems models such as hydrological, weather, and carbon monitoring models. In this work, we consider the Moderate Resolution Image Spectrometer (MODIS) data collected by the NASA's terra satellite. Artificial Neural Networks (ANNs) is a natural fit for ML modelling of images. Several successes have been reported using machine learning related to image processing. We investigate the use of ML to register MODIS images. ANNs are investigated in combination with a Restricted Boltzmann Machines (RBM) as an auto-encoder. We will present results showing the accuracy and efficiency of this approach.The D-Wave 2XTM quantum annealer samples the ground-state wave-function of a spin-Ising systems with quadratic interactions between qubits and a Chimera connectivity. The system sits in a ~15 mK thermal bath. One can think of the system as being placed in the ground state initially and subject to thermal excitations governed by Boltzmann statistics. If this is assumed true, one can use the statistics from the D-Wave 2XTM to train RBMs. Generating statistics for training Boltzmann machines is an NP-hard problem and constitutes the largest compute cost. We investigate the use of the D-Wave 2XTM to accelerate the training of the RBMs in our ANNs and report on the results.

Kouatchou, Jules↗

Patient motion effects on the quantification of regional myocardial blood flow with dynamic PET imaging

Purpose: Patient motion is a common problem during dynamic positron emission tomography (PET) scans for quantification of myocardial blood flow (MBF). The purpose of this study was to quantify the prevalence of body motion in a clinical setting and evaluate with realistic phantoms the effects of motion on blood flow quantification, including CT attenuation correction (CTAC) artifacts that result from PET–CT misalignment. Methods: A cohort of 236 sequential patients was analyzed for patient motion under resting and peak stress conditions by two independent observers. The presence of motion, affected time-frames, and direction of motion was recorded; discrepancy between observers was resolved by consensus review. Based on these results, patient body motion effects on MBF quantification were characterized using the digital NURBS-based cardiac-torso phantom, with characteristic time activity curves (TACs) assigned to the heart wall (myocardium) and blood regions. Simulated projection data were corrected for attenuation and reconstructed using filtered back-projection. All simulations were performed without noise added, and a single CT image was used for attenuation correction and aligned to the early- or late-frame PET images. Results: In the patient cohort, mild motion of 0.5 ± 0.1 cm occurred in 24% and moderate motion of 1.0 ± 0.3 cm occurred in 38% of patients. Motion in the superior/inferior direction accounted for 45% of all detected motion, with 30% in the superior direction. Anterior/posterior motion was predominant (29%) in the posterior direction. Left/right motion occurred in 24% of cases, with similar proportions in the left and right directions. Computer simulation studies indicated that errors in MBF can approach 500% for scans with severe patient motion (up to 2 cm). The largest errors occurred when the heart wall was shifted left toward the adjacent lung region, resulting in a severe undercorrection for attenuation of the heart wall. Simulations also indicated that the magnitude of MBF errors resulting from motion in the superior/inferior and anterior/posterior directions was similar (up to 250%). Body motion effects were more detrimental for higher resolution PET imaging (2 vs 10 mm full-width at half-maximum), and for motion occurring during the mid-to-late time-frames. Motion correction of the reconstructed dynamic image series resulted in significant reduction in MBF errors, but did not account for the residual PET–CTAC misalignment artifacts. MBF bias was reduced further using global partial-volume correction, and using dynamic alignment of the PET projection data to the CT scan for accurate attenuation correction during image reconstruction. Conclusions: Patient body motion can produce MBF estimation errors up to 500%. To reduce these errors, new motion correction algorithms must be effective in identifying motion in the left/right direction, and in the mid-to-late time-frames, since these conditions produce the largest errors in MBF, particularly for high resolution PET imaging. Ideally, motion correction should be done before or during image reconstruction to eliminate PET-CTAC misalignment artifacts.

60 APPLIED LIFE SCIENCES↗

SU-F-J-156: The Feasibility of MR-Only IMRT Planning for Prostate Anatomy

Purpose: For prostate anatomy, previous investigations have shown that simulated CT (sCT) generated from MR images can be used for accurate dose computation. In this study, we demonstrate the feasibility of MR-only IMRT planning for prostate case. Methods: Regular CT (rCT) and MR images of the same patient were acquired for prostate anatomy. Regions-of-interest (ROIs) i.e. target and risk structures are delineated on the rCT. A simulated CT (sCT) is generated from the MR image using the method described by Schadewaldt N et al. Their work establishes the clinical acceptability of dose calculation results on the sCT when compared to rCT. rCT and sCT are rigidly registered to ensure proper alignment between the two images. rCT and sCT are overlaid on each other and slice-wise visual inspection confirms excellent agreement between the two images. ROIs on the rCT are copied over to sCT. Philips AutoPlanning solution is used for generating treatment plans. The same treatment technique protocol (plan parameters and clinical goals) is used to generate AutoPlan-rCT and AutoPlan-sCT respectively for rCT and and sCT. DVH comparison on ROIs and slice-wise evaluation of dose is performed between AutoPlan-rCT and AutoPlan-sCT. Delivery parameters i.e. beam and corresponding segments from the AutoPlan-sCT are copied over to rCT and dose is computed to get AutoPlan-sCT-on-rCT. Results: Plan evaluation is done based on Dose Volume Histogram (DVH) of ROIs and manual slice-wise inspection of dose distribution. Both AutoPlan-rCT and AutoPlan-sCT provide a clinically acceptable plan. Also, AutoPlan-sCT-on-rCT shows excellent agreement with AutoPlan-sCT. Conclusion: The study demonstrates that it is feasible to do IMRT planning on the simulated CT image obtained from MR image for prostate anatomy. The research is supported by Philips India Ltd.

60 APPLIED LIFE SCIENCES↗

MusMorph, a database of standardized mouse morphology data for morphometric meta-analyses

Complex morphological traits are the product of many genes with transient or lasting developmental effects that interact in anatomical context. Mouse models are a key resource for disentangling such effects, because they offer myriad tools for manipulating the genome in a controlled environment. Unfortunately, phenotypic data are often obtained using laboratory-specific protocols, resulting in self-contained datasets that are difficult to relate to one another for larger scale analyses. To enable meta-analyses of morphological variation, particularly in the craniofacial complex and brain, we created MusMorph, a database of standardized mouse morphology data spanning numerous genotypes and developmental stages, including E10.5, E11.5, E14.5, E15.5, E18.5, and adulthood. To standardize data collection, we implemented an atlas-based phenotyping pipeline that combines techniques from image registration, deep learning, and morphometrics. Alongside stage-specific atlases, we provide aligned micro-computed tomography images, dense anatomical landmarks, and segmentations (if available) for each specimen (N = 10,056). Our workflow is open-source to encourage transparency and reproducible data collection.

59 BASIC BIOLOGICAL SCIENCES↗

Alignment and Bonding of Silicon Mirrors for High-Resolution Astronomical X-Ray Optics [10699-141]

Future large x-ray astronomy missions require large area and high resolution. The present consensus is to integrate thin, lightweight, segmented mirrors to form a compact but large telescope with high resolution (better than 1 sec). Key technologies: 1) Accurate mirror substrates: polishing high quality mono-crystalline silicon. 2) Stress-free reflective coating: stress-based distortion cancellation. 3) Precise alignment and integration: kinematic mounting and distortion-free bonding. Four-point alignment for quasi-cylindrically symmetric mirrors (segments) - 4-Point alignment: Pitch and yaw angles, image center (X, Y) are controlled by heights of the 4 mount points; Alignment Precision: better than 1 sec; Bonding error: approx. 0.1 micrometers (approx. 1 sec); Current single mirror pair x-ray tested: 3 sec (Half-Power Diameter). Integration into (meta) shell: Shell structure has rotationally defined axis; Interlocking mirrors means lightweight, mechanically strong telescope.

Chan, Kai-Wing↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Measuring the Cryogenic Optical Alignment Between the Telescope Element and the Instruments Module of the James Webb Space Telescope

The alignment between the Aft Optical Subsystem (AOS) and the Integrated Science Instruments Module (ISIM) is non-adjustable in orbit, so the alignment must be carefully verified in a cryogenic vacuum environment prior to launch. Optical point source locations calibrated by optical metrology instruments are imaged through the AOS onto the Science Instruments to determine focal, lateral, and clock angle alignment. The pupil image of the AOS is overlaid onto the pupil image of the NIRCam to determine the tip and tilt alignment. In addition, an image from fiducial lights at the Primary Mirror checks the pupil alignment between the telescope entrance pupil, the telescope pupil mask, and the NIRCam aperture stop. The image positions are combined to determine the relative alignment between the Optical Telescope Element (OTE) and the ISIM in all six degrees of freedom with corresponding alignment uncertainties. Uncertainties in the position of focused images of the test sources and images from the pupils are derived from sensitivities of an optical model of the system and the Science Instrument sensing capability. Additional uncertainty in the pupil alignment measurement is due to uncertainty in the analytical removal of gravity effects that simulate the on-orbit alignment environment.

Whitman, Tony↗

Postprocessing Algorithm for Driving Conventional Scanning Tunneling Microscope at Fast Scan Rates

We present an image postprocessing framework for Scanning Tunneling Microscope (STM) to reduce the strong spurious oscillations and scan line noise at fast scan rates and preserve the features, allowing an order of magnitude increase in the scan rate without upgrading the hardware. The proposed method consists of two steps for large scale images and four steps for atomic scale images. For large scale images, we first apply for each line an image registration method to align the forward and backward scans of the same line. In the second step we apply a “rubber band” model which is solved by a novel Constrained Adaptive and Iterative Filtering Algorithm (CIAFA). The numerical results on measurement from copper(111) surface indicate the processed images are comparable in accuracy to data obtained with a slow scan rate, but are free of the scan drift error commonly seen in slow scan data. For atomic scale images, an additional first step to remove line-by-line strong background fluctuations and a fourth step of replacing the postprocessed image by its ranking map as the final atomic resolution image are required. The resulting image restores the lattice image that is nearly undetectable in the original fast scan data.

47 OTHER INSTRUMENTATION↗

Investigating the Role of the Earth's Ionosphere in Space Weather: Modeling and Observations of High-Latitude Ionospheric Outflows

We will present what we believe to be the first reported observations of up- and downflows of topside ionospheric thermal plasmas from multiple near-simultaneous tracks through the high-latitude topside ionosphere. From several Southern polar passes, it has been possible to construct plots of field-aligned flows of 0+ observed by the Thermal Ion Dynamics Experiment(TIDE) on the POLAR spacecraft near 5000 km altitude together with vertical ion flow observations from one or more DMSP spacecraft near 800 km altitude. We also will present simultaneous observations of POLAR auroral LTVI images with field-aligned flows. We will further show new fluid-kinetic simulations of auroral ionospheric flows in the altitude range 120 km to several R-E as subjected to the synergistic auroral effects of soft electron precipitation, transverse wave-driven ion heating, and hot plasma-driven electric potentials.

Horwitz, J. L.↗

Multimodal imaging and machine learning to enhance microscope images of shale

A machine learning based image processing workflow is presented to enhance shale source rock microscopic images obtained using diverse imaging platforms. Images were acquired from a 30 μm diameter cylindrical Vaca Muerta shale sample using both nondestructive Transmission X-Ray Microscopy (TXM, alternately referred to as nano computed tomography) and destructive Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM). Output cross-sectional images from each modality were aligned using a combination of manual and automated registration techniques to create a registered image dataset. We then apply this dataset for two image processing tasks: prediction of image cross sections with SEM-like resolution from nondestructive TXM data and repair of charged region artifacts (localized accumulation of electrons) within SEM images. The image processing algorithms for both tasks use deep learning models, specifically image-to-image Convolutional Neural Networks (CNNs) and conditional Generative Adversarial Networks (cGANs). In the image enhancement tasks, we are able to achieve significant qualitative and quantitative improvement in TXM images. Here, the best model reaches an average Peak Signal to Noise Ratio (PSNR) of 15.8 dB. Conditioning on TXM data is also shown to reduce artifacts from SEM charging, achieving an average PSNR of 25.8 dB. Furthermore, our results suggest that properly trained and validated networks are capable of significant enhancement of images obtained using nondestructive techniques, thereby improving interpretation of two- and three-dimensional images while preserving samples for future use.

58 GEOSCIENCES↗

In-situ observation of calcium chloride hexahydrate phase separation via neutron imaging

Inorganic salt hydrate offers a low-cost thermal energy storage solution with high energy density, but phase separation during thermal cycling poses a significant challenge, leading to irreversible performance degradation. In this research, neutron radiography was used to investigate phase separation in calcium chloride hexahydrate (CaCl₂·6H₂O, CCH) during thermal cycling to track its gradual accumulation into calcium chloride tetrahydrate (CaCl₂·4H₂O, CC4). Through in-situ visualization, phase separation and CC4 sedimentation were observed to occur during the cooling phase between 301.40 K and 304.80 K. CC4 accumulated linearly to 7.99 wt% after 10 thermal cycles. Crystallization and multi-cycle conversion models were developed to validate neutron imaging results of CC4 formation. The predicted CC4 content after 10 thermal cycles closely aligned with experimental observations. Neutron imaging offers a novel approach to investigate salt hydrate phase change materials (PCMs). It enables in-situ visualization of sub-hydrate (CC4) formation from original hydrate (CCH) in metastable phase change range (between 301.40 ± 0.66 K and 304.80 ± 0.60 K). Thereby, it provides a new insight of understanding the basis of phase separation mechanism and paves the way for future research of improving PCM thermal cycling performance.

Li, Yucen [The University of Tennessee, Knoxville]↗

Alignment and Performance of the Infrared Multi-Object Spectrometer

The Infrared Multi-Object Spectrometer (IRMOS) is a principle investigator class instrument for the Kitt Peak National Observatory 4 and 2.1 meter telescopes. IRMOS is a near-IR (0.8 - 2.5 micron) spectrometer with low-to mid-resolving power (R = 300 - 3000). IRMOS produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arc-min field of view (4 m telescope) using a commercial Micro Electro-Mechanical Systems (MEMS) micro-mirror array (MMA) from Texas Instruments. The IRMOS optical design consists of two imaging subsystems. The focal reducer images the focal plane of the telescope onto the MMA field stop, and the spectrograph images the MMA onto the detector. We describe ambient breadboard subsystem alignment and imaging performance of each stage independently, and ambient imaging performance of the fully assembled instrument. Interferometric measurements of subsystem wavefront error serve as a qualitative alignment guide, and are accomplished using a commercial, modified Twyman-Green laser unequal path interferometer. Image testing provides verification of the optomechanical alignment method and a measurement of near-angle scattered light due to mirror small-scale surface error. Image testing is performed at multiple field points. A mercury-argon pencil lamp provides a spectral line at 546.1 nanometers, a blackbody source provides a line at 1550 nanometers, and a CCD camera and IR camera are used as detectors. We use commercial optical modeling software to predict the point-spread function and its effect on instrument slit transmission and resolution. Our breadboard and instrument level test results validate this prediction. We conclude with an instrument performance prediction for cryogenic operation and first light in late 2003.

Connelly, Joseph A.↗