A New Pad-Based Neutron Detector for Stereo Coded-Aperture Thermal Neutron Imaging
N/A
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
N/A
A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.
The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.
This publication is a compilation of the papers presented at the NASA conference on Visual Information Processing for Television and Telerobotics. The conference was held at the Williamsburg Hilton, Williamsburg, Virginia on May 10 to 12, 1989. The conference was sponsored jointly by NASA Offices of Aeronautics and Space Technology (OAST) and Space Science and Applications (OSSA) and the NASA Langley Research Center. The presentations were grouped into three sessions: Image Gathering, Coding, and Advanced Concepts; Systems; and Technologies. The program was organized to provide a forum in which researchers from industry, universities, and government could be brought together to discuss the state of knowledge in image gathering, coding, and processing methods.
This code processes the images collected during high throughput tensile tests to measure the area of each specimen. First, the code identifies the reference images and primary sample images from list of images collected. Then, the size of the reference in the reference images is used to determine a scale (um/pixel) value which can be used to determine the size of each sample in an image. The subsequent sample images are processed to automatically detect the sample present and then identify the size in pixels. The measurements from two different views of the sample are then combined to determine the sample area (um2).
I/O is increasingly becoming a significant constraint for simulation codes and visualization tools on modern supercomputers. Data compression is an attractive workaround, and, in particular, wavelets provide a promising solution. However, wavelets can be applied in multiple configurations, and the variations in configuration impact accuracy, storage cost, and execution time. While the variation in these factors over wavelet configurations have been explored in image processing, they are not well understood for visualization and analysis of scientific data. To illuminate this issue, we evaluate multiple wavelet configurations on turbulent-flow data. Our approach is to repeat established analysis routines on uncompressed and lossy-compressed versions of a data set, and then quantitatively compare their outcomes. Our findings show that accuracy varies greatly based on wavelet configuration, while storage cost and execution time vary less. Overall, our study provides new insights for simulation analysts and visualization experts, who need to make tradeoffs between accuracy, storage cost, and execution time.
Version 4.1 of LAS provides flexible framework for algorithm development and processing and analysis of image data. Over 500,000 lines of code enable image repair, clustering, classification, film processing, geometric registration, radiometric correction, and manipulation of image statistics.
An x-ray spectrometer that also provides images of an x-ray source. Coded aperture imaging techniques are used to provide high resolution images. Imaging position-sensitive x-ray sensors with good energy resolution are utilized to provide excellent spectroscopic performance. The system produces high resolution spectral images of the x-ray source which can be viewed in any one of a number of specific energy bands.
The first full prototype of the RatCAP PET system, designed to image the brain of a rat while conscious, has been completed. Initial results demonstrated excellent spatial resolution, 1.8 mm FWHM with filtered backprojection and <1.5 mm FWHM with a Monte Carlo based MLEM method. However, noise equivalent countrate studies indicated the need for better timing to mitigate the effect of randoms. Thus, the front-end ASIC has been redesigned to minimize time walk, an accurate coincidence time alignment method has been implemented, and a variance reduction technique for the randoms is being developed. To maximize the quantitative capabilities required for neuroscience, corrections are being implemented and validated for positron range and photon noncollinearity, scatter (including outside the field of view), attenuation, randoms, and detector efficiency (deadtime is negligible). In addition, a more robust and compact PCI-based optical data acquisition system has been built to replace the original VME-based system while retaining the linux-based data processing and image reconstruction codes. Finally, a number of new animal imaging experiments have been carried out to demonstrate the performance of the RatCAP in real imaging situations, including an F-18 fluoride bone scan, a C-11 raclopride scan, and a dynamic C-11 methamphetamine scan.
Gamma-ray imagers with coded apertures have a finite field of view (FOV) within which an image of a source can be generated. A “FOV scan” is a facet of imager calibration procedure that involves collecting specialized data for a range of source locations filling the FOV in order to understand and correct for differences in imager performance. Systematic distortions reveal relative displacements between internal imager components, which can be accounted for in data analysis. The success of this scan requires a stable imager position during the full measurement duration (~hours). This document summarizes the hardware and software tools required to conduct a FOV calibration scan of an H3D H420 Coded Aperture Gamma-Ray Imager.
Purpose: This study intends to characterize the spectral and spatial resolution limits of various fan beam geometries for differentiation of normal and neoplastic breast structures via coded aperture coherent scatter spectral imaging techniques. In previous studies, pencil beam raster scanning methods using coherent scatter computed tomography and selected volume tomography have yielded excellent results for tumor discrimination. However, these methods don’t readily conform to clinical constraints; primarily prolonged scan times and excessive dose to the patient. Here, we refine a fan beam coded aperture coherent scatter imaging system to characterize the tradeoffs between dose, scan time and image quality for breast tumor discrimination. Methods: An X-ray tube (125kVp, 400mAs) illuminated the sample with collimated fan beams of varying widths (3mm to 25mm). Scatter data was collected via two linear-array energy-sensitive detectors oriented parallel and perpendicular to the beam plane. An iterative reconstruction algorithm yields images of the sample’s spatial distribution and respective spectral data for each location. To model in-vivo tumor analysis, surgically resected breast tumor samples were used in conjunction with lard, which has a form factor comparable to adipose (fat). Results: Quantitative analysis with current setup geometry indicated optimal performance for beams up to 10mm wide, with wider beams producing poorer spatial resolution. Scan time for a fixed volume was reduced by a factor of 6 when scanned with a 10mm fan beam compared to a 1.5mm pencil beam. Conclusion: The study demonstrates the utility of fan beam coherent scatter spectral imaging for differentiation of normal and neoplastic breast tissues has successfully reduced dose and scan times whilst sufficiently preserving spectral and spatial resolution. Future work to alter the coded aperture and detector geometries could potentially allow the use of even wider fans, thereby making coded aperture coherent scatter imaging a clinically viable method for breast cancer detection. United States Department of Homeland Security; Duke University Medical Center - Department of Radiology; Carl E Ravin Advanced Imaging Laboratories; Duke University Medical Physics Graduate Program.
Improved understanding of the nature of active galaxies will require detailed observations of 10 to 20 sources, while understanding of their gamma ray luminosity function and its evolution will require the detection of approximately 100 sources. Instruments capable of detecting 100 active galaxies at low-energy, gamma ray energies are achievable. The angular resolution of an instrument, as well as its sensitivity, can limit the number of sources it can observe. An investigation of the angular resolution requirements for future low-energy gamma ray instruments is presented. It was found that the strictest requirements arise not from the need to resolve detectable sources, but from the need to control the level of direction-to-direction fluctuations in the diffuse background level. It was concluded that gamma-ray instruments capable of detecting 100 active galaxies must have sub-degree angular resolution. The use of the coded aperture imaging technique is proposed as a method of achieving accurate control of systematic errors and fine angular resolution without unduly increasing the time needed to conduct full sky surveys. An analysis of coded aperture imaging is presented for instruments that employ masks based on hexagonal uniformly redundant arrays. An instrument, the gamma-ray imaging payload, was built that employs these imaging techniques. The design and testing of the instrument is described in detail. Preliminary results from a balloon flight of the instruments are shown, demonstrating its imaging performance.
Purpose: To develop a real-time applicator position monitoring system (RAPS) for intracavitary brachytherapy using an infrared camera and reflective markers. Methods: 3D image-guided brachytherapy requires high accuracy of applicator localization; however, applicator displacement can happen during patient transfer for imaging and treatment delivery. No continuous applicator position monitoring system is currently available. The RAPS system was developed for real-time applicator position monitoring without additional radiation dose to patients. It includes an infrared camera, reflective markers, an infrared illuminator, and image processing software. After reflective markers are firmly attached to the applicator and the patient body, applicator displacement can be measured by computing the relative change in distance between the markers. The reflective markers are magnetic resonance imaging (MRI) compatible, which is suitable for MRI-guided HDR brachytherapy paradigm. In our prototype, a Microsoft Kinect sensor with a resolution of 640 by 480 pixels is used as an infrared camera. A phantom study was carried out to compare RAPS' measurements with known displacements ranging from −15 to +15 mm. A reproducibility test was also conducted. Results: The RAPS can achieve 4 frames/s using a laptop with Intel{sup ®} Core™2 Duo processor. When the pixel size is 0.95 mm, the difference between RAPS' measurements and known shift values varied from 0 to 0.8 mm with the mean value of 0.1 mm and a standard deviation of 0.44 mm. The system reproducibility was within 0.6 mm after ten reposition trials. Conclusions: This work demonstrates the feasibility of a real-time infrared camera based gynecologic intracavitary brachytherapy applicator monitoring system. Less than 1 mm accuracy is achieved when using an off-the-shelf infrared camera.
It is a fact that adjacent pixels in a Voyager image are very similar in grey level. This fact can be used in conjunction with the Maximum-Likelihood Convolutional Decoder (MCD) to decrease the error rate when decoding a picture from Voyager. Implementing this idea would require no changes in the Voyager spacecraft and could be used as a backup to the current system without too much expenditure, so the feasibility of it and the possible gains for Voyager were investigated. Simulations have shown that the gain could be as much as 2 dB at certain error rates, and experiments with real data inspired new ideas on ways to get the most information possible out of the received symbol stream.
Standard clinical terms, codes, and ontologies promote clarity and interoperability. Within radiology, there is a variety of relevant content resources, tools and technologies. These provide the basis for fundamental imaging workflows such as reporting and billing, and also facilitate a range of applications in quality improvement and research. This article reviews the key characteristics of lexicons, coding systems, and ontologies. A number of standards are described, including International Classification of Diseases-10-Clinical Modification (ICD-10-CM), Current Procedural Terminology (CPT), Systematized Nomenclature of Medicine—Clinical Terms (SNOMED CT), Logical Observation Identifiers Names and Codes (LOINC), and RadLex. Tools for accessing this material are reviewed, such as the National Center for Biomedical Ontology BioPortal system. Web services are discussed as a mechanism for semantic application development. Several example systems, workflows, and research applications using semantic technology are also surveyed.
Purpose: Easy particle propagation (Epp) is a user code for the EGSnrc code package based on the C++ class library egspp. A main feature of egspp (and Epp) is the ability to use analytical objects to construct simulation geometries. The authors developed Epp to facilitate the simulation of x-ray imaging geometries, especially in the case of scatter studies. While direct use of egspp requires knowledge of C++, Epp requires no programming experience. Methods: Epp's features include calculation of dose deposited in a voxelized phantom and photon propagation to a user-defined imaging plane. Projection images of primary, single Rayleigh scattered, single Compton scattered, and multiple scattered photons may be generated. Epp input files can be nested, allowing for the construction of complex simulation geometries from more basic components. To demonstrate the imaging features of Epp, the authors simulate 38 keV x rays from a point source propagating through a water cylinder 12 cm in diameter, using both analytical and voxelized representations of the cylinder. The simulation generates projection images of primary and scattered photons at a user-defined imaging plane. The authors also simulate dose scoring in the voxelized version of the phantom in both Epp and DOSXYZnrc and examine the accuracy of Epp using the Kawrakow-Fippel test. Results: The results of the imaging simulations with Epp using voxelized and analytical descriptions of the water cylinder agree within 1%. The results of the Kawrakow-Fippel test suggest good agreement between Epp and DOSXYZnrc. Conclusions: Epp provides the user with useful features, including the ability to build complex geometries from simpler ones and the ability to generate images of scattered and primary photons. There is no inherent computational time saving arising from Epp, except for those arising from egspp's ability to use analytical representations of simulation geometries. Epp agrees with DOSXYZnrc in dose calculation, since they are both based on the well-validated standard EGSnrc radiation transport physics model.
Explore the source record for details and available documents.