Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Improved reconstruction stability for chemical shift encoded hyperpolarized 13 C magnetic resonance spectroscopic imaging using k‐t spiral acquisitions

Purpose A multiecho, field of view (FOV)‐oversampled k‐t spiral acquisition and direct iterative decomposition of water and fat with echo asymmetry and least‐squares estimation reconstruction is demonstrated to improve the stability of hyperpolarized 13 C magnetic resonance spectroscopic imaging (MRSI) in the presence of signal ambiguities attributed to low‐SNR (signal‐to‐noise‐ratio) species, local uncertainties in metabolite peaks, and echo‐to‐echo signal inconsistencies. Theory k‐t spiral acquisitions redistribute readout points to be more densely spaced radially in k‐space by acquiring an FOV and matrix that are oversampled by η . These more densely spaced spiral turns constitute effective intraspiral echoes and can supplement conventional interspiral echoes to improve spectral separation and reduce spectral cross‐talk to better resolve 13 C‐labeled species for spectroscopic imaging. Methods Digital simulations and imaging phantom experiments were performed for a range of interspiral echo spacings and η using multiecho, k‐t spiral acquisitions. Image spectral cross‐talk artifacts were evaluated both qualitatively and quantitatively as the percent error in measured metabolite ratios. In vivo murine experiments evaluated the feasibility of multiecho, k‐t spiral [1‐ 13 C]pyruvate MRSI to reduce spectral cross‐talk for 3 scenarios of different expected reconstruction stability. Results Digital simulations and imaging phantom experiments both demonstrated reduced or comparable image spectral cross‐talk and percent errors in measured metabolite ratios with increasing η and better choices of echo spacings. In vivo images displayed markedly reduced spectral cross‐talk in lactate images acquired with η = 7 versus η = 1. Conclusion The precision of hyperpolarized 13 C metabolic imaging and quantification in the presence of low‐SNR species, local uncertainties in metabolite resonances, and echo‐to‐echo signal inconsistencies can be improved with the use of FOV‐oversampled k‐t spiral acquisitions.

Macdonald, Erin B.↗

Prostate Localization on Daily Cone-Beam Computed Tomography Images: Accuracy Assessment of Similarity Metrics

Purpose: To evaluate different similarity metrics (SM) using natural calcifications and observation-based measures to determine the most accurate prostate and seminal vesicle localization on daily cone-beam CT (CBCT) images. Methods and Materials: CBCT images of 29 patients were retrospectively analyzed; 14 patients with prostate calcifications (calcification data set) and 15 patients without calcifications (no-calcification data set). Three groups of test registrations were performed. Test 1: 70 CT/CBCT pairs from calcification dataset were registered using 17 SMs (6,580 registrations) and compared using the calcification mismatch error as an endpoint. Test 2: Using the four best SMs from Test 1, 75 CT/CBCT pairs in the no-calcification data set were registered (300 registrations). Accuracy of contour overlays was ranked visually. Test 3: For the best SM from Tests 1 and 2, accuracy was estimated using 356 CT/CBCT registrations. Additionally, target expansion margins were investigated for generating registration regions of interest. Results: Test 1-Incremental sign correlation (ISC), gradient correlation (GC), gradient difference (GD), and normalized cross correlation (NCC) showed the smallest errors ({mu} {+-} {sigma}: 1.6 {+-} 0.9 {approx} 2.9 {+-} 2.1 mm). Test 2-Two of the three reviewers ranked GC higher. Test 3-Using GC, 96% of registrations showed <3-mm error when calcifications were filtered. Errors were left/right: 0.1 {+-} 0.5mm, anterior/posterior: 0.8 {+-} 1.0mm, and superior/inferior: 0.5 {+-} 1.1 mm. The existence of calcifications increased the success rate to 97%. Expansion margins of 4-10 mm were equally successful. Conclusion: Gradient-based SMs were most accurate. Estimated error was found to be <3 mm (1.1 mm SD) in 96% of the registrations. Results suggest that the contour expansion margin should be no less than 4 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hydrodynamic Characterization of a Shallow Rectangular Spouted Bed Using Bed Pressure Signals and Image Processing Methods

To support the design of spouted bed reactors, experiments are performed in a rectangular spouted bed to measure the peak pressure drop (Δ P max ) and the internal and external spouting velocities ( U is and U es ). Four particle types spanning under Geldart D and B are used. U is and U es are measured from bed pressure drop and expansion ratio profiles, respectively, with the U es / U is ratio of each particle type obtained. Additionally, correlations predicting the Δ P max of Geldart D and B particles are developed by reviewing published correlations and investigating the nozzle effect. Good prediction is achieved with a slope of 0.997 and an adjusted R 2 of 0.998 in a 95% confidence interval. U es is predicted through correlations developed by adding effects of d p / D i and H 0 in the Mathur–Gishler equation. The calculated U es agrees well with the experimental data, achieving a slope of 0.998 and an adjusted R 2 of 0.998 in a 95% confidence interval.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A note on the visualization of wetting film structures and a nonwetting immiscible fluid in a pore network micromodel using a solvatochromic dye

Nile Red is demonstrated as a single dye whose solvatochromism enables selective visualization of two immiscible liquid fluids in a micromodel containing a homogeneous array of pillars creating a porous network. Nile Red dissolves in and partitions between hexadecane as a nonwetting fluid and PEG200 as a hydrophilic fluid that wets the silicon oxide surfaces in the micromodel. Both the absorption spectra and fluorescence emission spectra are sensitive to the solvent environment, such that the two phases can be distinguished by the observed color or the fluorescence emission band. Bright field, hyperspectral, epifluorescence, and confocal fluorescence methods were used to image the micromodel after displacing PEG200 in the model with hexadecane. The use of Nile Red with these imaging methods facilitates visualization of phase identity at specific locations; the interfaces between the two immiscible liquid phases; wetting behavior of the wetting phase within the porous structure; and retention of the wetting phase as thin films around pillars and as bridges across the pore throats. The pillars and wetting phase bridges create a network of obstacles defining a tortuous preferential flow path for the nonwetting phase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Invited Review Article: Methods for imaging weak-phase objects in electron microscopy

Contrast has traditionally been produced in electron-microscopy of weak phase objects by simply defocusing the objective lens. There now is renewed interest, however, in using devices that apply a uniform quarter-wave phase shift to the scattered electrons relative to the unscattered beam, or that generate in-focus image contrast in some other way. Renewed activity in making an electron-optical equivalent of the familiar “phase-contrast” light microscope is based in part on the improved possibilities that are now available for device microfabrication. There is also a better understanding that it is important to take full advantage of contrast that can be had at low spatial frequency when imaging large, macromolecular objects. In addition, a number of conceptually new phase-plate designs have been proposed, thus increasing the number of options that are available for development. The advantages, disadvantages, and current status of each of these options is now compared and contrasted. Experimental results that are, indeed, superior to what can be accomplished with defocus-based phase contrast have been obtained recently with two different designs of phase-contrast aperture. Nevertheless, extensive work also has shown that fabrication of such devices is inconsistent, and that their working lifetime is short. The main limitation, in fact, appears to be electrostatic charging of any device that is placed into the electron diffraction pattern. The challenge in fabricating phase plates that are practical to use for routine work in electron microscopy thus may be more in the area of materials science than in the area of electron optics.

36 MATERIALS SCIENCE↗

WE-G-18A-05: Cone-Beam CT Reconstruction with Deformed Prior Image

Purpose: Prior image can be incorporated into image reconstruction process to improve the quality of on-treatment cone-beam CT (CBCT) from sparseview or low-dose projections. However, the deformation between the prior image and on-treatment CBCT are not considered in current prior image based reconstructions (e.g., prior image constrained compressed sensing (PICCS)). The purpose of this work is to develop a deformed-prior-imagebased- reconstruction strategy (DPIR) to address the mismatch problem between the prior image and target image. Methods: The deformed prior image is obtained by a projection based registration approach. Specifically, the deformation vector fields (DVF) used to deform the prior image is estimated through matching the forward projection of the prior image and the measured on-treatment projection. The deformed prior image is then used as the prior image in the standard PICCS algorithm. Simulation studies on the XCAT phantom was conducted to evaluate the performance of the projection based registration procedure and the proposed DPIR strategy. Results: The deformed prior image matches the geometry of on-treatment CBCT closer as compared to the original prior image. Using the deformed prior image, the quality of the image reconstructed by DPIR from few-view projection data is greatly improved as compared to the standard PICCS algorithm. The relative image reconstruction error is reduced to 11.13% in the proposed DPIR from 17.57% in the original PICCS. Conclusion: The proposed DPIR approach can solve the mismatch problem between the prior image and target image, which overcomes the limitation of the original PICCS algorithm for CBCT reconstruction from sparse-view or low-dose projections.

60 APPLIED LIFE SCIENCES↗

Sci—Fri AM: Mountain — 02: A comparison of dose reduction methods on image quality for cone beam CT

Modern radiotherapy uses highly conformai dose distributions and therefore relies on daily image guidance for accurate patient positioning. Kilovoltage cone beam CT is one technique that is routinely used for patient set-up and results in a high dose to the patient relative to planar imaging techniques. This study uses an Elekta Synergy linac equipped with XVI cone beam CT to investigate the impact of various imaging parameters on dose and image quality. Dose and image quality are assessed as functions of x-ray tube voltage, tube current and the number of projections in the scan. In each case, the dose measurements confirm that as each parameter increases the dose increases. The assessment of high contrast resolution shows little dependence on changes to the image technique. However, low contrast visibility suggests a trade off between dose and image quality. Particularly for changes in tube potential, the dose increases much faster as a function of voltage than the corresponding increase in low contrast image quality. This suggests using moderate values of the peak tube voltage (100 – 120 kVp) since higher values result in significant dose increases with little gain in image quality. Measurements also indicate that increasing tube current achieves the greatest degree of improvement in the low contrast visibility. The results of this study highlight the need to establish careful imaging protocols to limit dose to the patient and to limit changes to the imaging parameters to those cases where there is a clear clinical requirement for improved image quality.

60 APPLIED LIFE SCIENCES↗

SU-F-J-26: Performance of 2.5MV Portal Imaging in Comparison with KV X-Ray and 6MV and Flattening-Filter-Free 6MV Portal Imaging

Purpose: To assess image quality and imaging dose of 2.5MV electronic portal imaging in comparison to kV imaging and 6MV and Flattening-Filter-Free 6MV (6MVFFF) portal imaging using a DMI imager. Methods: Quantitative assessment of image quality was performed with Leeds and Las Vegas test phantoms in conjunction with qualitative evaluation of clinical patient images for kV imaging and 2.5MV, 6MV and 6MVFFF portal imaging. High and low contrast resolutions were evaluated and imaging doses were measured using these x-rays. Phantom test was performed both in air and in solid water. Clinical patient portal images were also reviewed and qualitatively assessed for these three imaging MV energies. Results: Among the 28 objects in Las Vegas phantom, 16, 17 and 26 of them were resolved using Low Dose technique and 18, 22 and 26 were resolved using High Quality technique with 6MV, 6MVFFF and 2.5MV, respectively. The number of Leeds low contrast objects resolved by 6MV, 6MFFFF and 2.5MV was 6, 15 and 18 with Low Dose technique and 14, 17 and 18 with High Quality technique, respectively. When the test phantoms were embedded in 20cm thick solid water, the results were noticeably affected, but the performance of 2.5MV was still substantially better than 6MV and 6MVFFF. Imaging dose with 2.5MV measured at 10 cm depth was about half of that with 6MV or 6MVFFF. Clinical patient portal images were reviewed and qualitatively assessed for different sites including brain, head-and-neck, chest and pelvis. 2.5MV imaging provided more details and substantially higher contrast. Conclusion: While portal imaging with 6MVFFF provides noticeably better image quality than that with 6MV, the performance of 2.5MV portal imaging is substantially better than both 6MV and 6MVFFF in terms of high and low contrast resolutions as well as lower imaging dose. 2.5MV imaging provides near kV imaging quality.

60 APPLIED LIFE SCIENCES↗

WE-H-207A-06: Hypoxia Quantification in Static PET Images: The Signal in the Noise

Purpose: Quantification of hypoxia from PET images is of considerable clinical interest. In the absence of dynamic PET imaging the hypoxic fraction (HF) of a tumor has to be estimated from voxel values of activity concentration of a radioactive hypoxia tracer. This work is part of an effort to standardize quantification of tumor hypoxic fraction from PET images. Methods: A simple hypoxia imaging model in the tumor was developed. The distribution of the tracer activity was described as the sum of two different probability distributions, one for the normoxic (and necrotic), the other for the hypoxic voxels. The widths of the distributions arise due to variability of the transport, tumor tissue inhomogeneity, tracer binding kinetics, and due to PET image noise. Quantification of HF was performed for various levels of variability using two different methodologies: a) classification thresholds between normoxic and hypoxic voxels based on a non-hypoxic surrogate (muscle), and b) estimation of the (posterior) probability distributions based on maximizing likelihood optimization that does not require a surrogate. Data from the hypoxia imaging model and from 27 cervical cancer patients enrolled in a FAZA PET study were analyzed. Results: In the model, where the true value of HF is known, thresholds usually underestimate the value for large variability. For the patients, a significant uncertainty of the HF values (an average intra-patient range of 17%) was caused by spatial non-uniformity of image noise which is a hallmark of all PET images. Maximum likelihood estimation (MLE) is able to directly optimize for the weights of both distributions, however, may suffer from poor optimization convergence. For some patients, MLE-based HF values showed significant differences to threshold-based HF-values. Conclusion: HF-values depend critically on the magnitude of the different sources of tracer uptake variability. A measure of confidence should also be reported.

60 APPLIED LIFE SCIENCES↗

Devices, systems, and methods for imaging

Certain exemplary embodiments comprise a system, which can comprise an imaging plate. The imaging plate can be exposable by an x-ray source. The imaging plate can be configured to be used in digital radiographic imaging. The imaging plate can comprise a phosphor-based image storage device configured to convert an image stored therein into light.

Appleby, David↗

Radiation-transparent windows, method for imaging fluid transfers

A thin, x-ray-transparent window system for environmental chambers involving pneumatic pressures above 40 bar is presented. The window allows for x-ray access to such phenomena as fuel sprays injected into a pressurized chamber that mimics realistic internal combustion engine cylinder operating conditions.

47 OTHER INSTRUMENTATION↗

Apparatus and methods for imaging interior surfaces of a tube or the like

An exemplary device includes, on a longitudinal axis, an illumination-light source, an axicon (conic) mirror, an image sensor, and a tilted optical element. The light source provides illumination light propagating forwardly on the axis. The axicon mirror reflects the illumination light radially outward, relative to the axis, to the interior surface of a tube to produce reflected light propagating, from the illuminated interior surface, as imaging light back to the axicon, which reflects the imaging light rearwardly. The image sensor receives at least a portion of the imaging light rearwardly reflected by the axicon mirror. The tilted optical element, situated between the axicon mirror and the interior surface, moves a selected first portion of the imaging light away from being incident on the image sensor, while allowing a second portion of the imaging light to be incident on the image sensor.

Kisner, Roger A.↗