Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging spectrometers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Streaked Sub-ps-resolution X-ray Line Shapes and Implications for Solid-density Plasma Dynamics

A high-resolution x-ray spectrometer was coupled with an ultrafast x-ray streak camera to produce time-resolved line shape spectra measured from hot, solid-density plasmas. A Bragg crystal was placed near a laser-produced plasma to maximize throughput; alignment tolerances were established by raytracing. The streak camera produced single-shot time-resolved spectra, heavily sloped due to photon time-of-flight differences, with sufficient reproducibility to accumulate photon statistics. The images are time-calibrated by the slope of streaked spectra and dewarped to generate spectra emitted at different times defined at the source. The streaked spectra demonstrate the evolution of spectral shoulders and other features on ps timescales, showing the feasibility of plasma parameter measurements on the rapid timescales necessary to study high-energy-density plasmas.

High-energy-density plasmas↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Measuring Multicomponent Adsorption of Tracer Gases on Natural Zeolites

A natural clinoptilolite sample near the Nevada National Security Site was obtained to study adsorption and retardation on gas transport. Of interest is understanding the competition for adsorption sites that may reduce tracer gas adsorption relative to single-component measurements, which may be affected by the multi-scale pore structure of clinoptilolite. Clinoptilolite has three distinct domains of pore size distributions ranging from nanometers to micrometers: micropores with 0.4–0.7 nm diameters, measured on powders by CO2 adsorption at 273 K, representing the zeolite cages; mesopores with 4–200 nm diameters, observed using liquid nitrogen adsorption at 77 K; and macropores with 300–1000 nm diameters, measured by mercury injection on rock chips (~ 100 mesh), likely representing the microfractures. These pore size distributions are consistent with X-ray computed tomography (CT) and focused ion beam scanning electron microscope (FIB-SEM) images, which are used to construct the three-dimensional (3D) pore network to be used in future gas transport modeling. To quantify tracer gas adsorption in this multi-scale pore structure and multicomponent gas species environment, natural zeolite samples initially in equilibrium in air were exposed to a mixture of tracer gases. As the tracer gases diffuse and adsorb in the sample, the remaining tracer gases outside the sample fractionate. Using a quadrupole mass spectrometer to quantify this fractionation, the degree of adsorption of tracer gases in the multicomponent gas environment and multi-scale pore structure is assessed. The major finding is that Kr reaches equilibrium much faster than Xe in the presence of ambient air, which leads to more Kr uptake than Xe over limited exposure periods. When the clinoptilolite chips were exposed to humid air, the adsorption capability decreases significantly for both Xe and Kr with relative humidity (RH) as low as 3%. Both Xe and Kr reaches equilibrium faster at higher RH. The different, unexpected, adsorption behavior for Xe and Kr is due to their kinetic diameters similar to the micropores in clinoptilolite which makes it harder for Xe to access compared to Kr.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Spatial Mapping of Histone Proteoforms in Human Kidney Through MALDI-MSI by High-Field UHMR-Orbitrap Detection

Core histones including H2A, H2B, H3, and H4 are key modulators of cellular repair, transcription, and replication within eukaryotic cells, playing vital roles within the pathogenesis of disease and cellular responses to environmental stimuli. Traditional mass spectrometry (MS) based bottom-up and top-down proteomics allows for the comprehensive identification of proteins and of post-translational modification (PTM) harboring proteoforms. However, these methodologies have difficulties preserving near cellular spatial distributions because they typically require laser capture microdissection (LCM) and advanced sample preparation techniques. Herein, we coupled matrix-assisted laser desorption/ionization (MALDI) source with a Thermo Scientific Q-Exactive HF Orbitrap MS upgraded with ultra-high mass range (UHMR) boards for the first demonstration of complementary high-resolution accurate mass measurements of proteoforms directly from tissue using this benchtop mass spectrometer. The platform achieved isotopic resolution throughout the detected mass range, providing confident assignments of proteoforms with low ppm mass error and a vastly improved duty cycle over other Fourier transform mass analyzers. Proteoform mapping of core histones was demonstrated on sections of human kidney at near-cellular spatial resolution, with several key distributions of histone and other proteoforms noted within both healthy biopsy and a section from a renal cell carcinoma (RCC) containing nephrectomy. Further, the use of MALDI-MS imaging (MSI) for proteoform mapping demonstrates several steps towards high-throughput accurate identification of proteoforms and provides a new tool for mapping biomolecule distributions throughout tissue sections in extended mass ranges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Temporal X-ray Reconstruction using Temporal and Spectral Measurements at LCLS

Transverse deflecting structures (TDSs) are widely used in accelerator physics to measure the longitudinal density of particle bunches. When used in combination with a dispersive section, the whole longitudinal phase space density can be imaged. At the Linac Coherent Light Source (LCLS), the installation of such a device downstream of the undulators enables the reconstruction of the X-ray temporal intensity profile by comparing longitudinal phase space distributions with lasing on and lasing off. However, the resolution of this TDS is limited to around 1 fs rms (root mean square), and therefore, it is not possible to resolve single self-amplified spontaneous emission (SASE) spikes within an X-ray photon pulse. By combining the power spectrum from a high resolution photon spectrometer and the temporal structure from the TDS, the overall resolution is enhanced, thus allowing the observation of temporal, single SASE spikes. The combined data from the spectrometer and the TDS is analysed using an iterative algorithm to obtain the actual intensity profile. In this paper, we present some improvements to the reconstruction algorithm as well as real data taken at LCLS.

47 OTHER INSTRUMENTATION↗

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal response measurement of the x-ray transmission crystals used by the Imaging Spectroscopy Snout at the National Ignition Facility

The Imaging Spectroscopy Snout (ISS) used at the National Ignition Facility is able to simultaneously collect neutron pinhole images, 1D spatially resolved x-ray spectra, and time resolved x-ray pinhole images. To measure the x-ray spectra, the ISS can be equipped with up to four different transmission crystals, each offering different energy ranges from ∼7.5 to ∼12 keV and different resolutions. Characterizing and calibrating such instruments is of paramount importance in order to extract meaningful results from experiments. More specifically, we characterized different ISS transmission-type alpha-Quartz crystals by measuring their responses as a function of photon energy, from which we inferred the angle-integrated reflectivity for each crystal’s working reflections. These measurements were made at the Lawrence Livermore National Laboratory calibration station dedicated to the characterization of x-ray spectrometers. The sources used covered a wide x-ray range—from a few to 30 keV; the source diameter was ∼0.6 mm. The experimental results are discussed alongside theoretical calculations using the pyTTE model.

Dozieres, M. (ORCID:0000000286401459)↗

Design and expected performance of a variable-radii sinusoidal spiral x-ray spectrometer for the National Ignition Facility

A novel high-resolution x-ray spectrometer for point-like emission sources has been developed using a crystal shape having both a variable major and a variable minor radius of curvature. This variable-radii sinusoidal spiral spectrometer (VR-Spiral) allows three common spectrometer design goals to be achieved simultaneously: 1. reduction of aberrations and improved spectral (energy) resolution, 2. reduction of source size broadening, and 3. use of large crystals to improve total throughput. The VR-Spiral concept and its application to practical spectrometer design are described in detail. This concept is then used to design a spectrometer for an extreme extended x-ray absorption fine structure experiment at the National Ignition Facility looking at the Pb L 3 absorption edge at 13.0352 keV. The expected performance of this VR-Spiral spectrometer, both in terms of energy resolution and spatial resolution, is evaluated through the use of a newly developed raytracing tool, xicsrt. Finally, the expected performance of the VR-Spiral concept is compared to that of spectrometers based on conventional toroidal and variable-radii toroidal crystal geometries showing a greatly improved energy resolution.

47 OTHER INSTRUMENTATION↗

The Uranium-Containing and Thorium-Containing Anions Studied by Photoelectron Spectroscopy

An in-depth knowledge of actinide chemistry is fundamental to many aspects of nuclear science and technology, including the synthesis and processing of materials and the remediation of waste disposal sites. Among the actinides, the chemical bonding behaviors of actinium and thorium resemble those of the transition metals; the 5f-electrons of protactinium, uranium, neptunium, and plutonium often play important roles in their bonding; and among the still heavier elements, their bonding tends to mimic the lanthanide elements in terms of electron shielding and their f-electron contributions. Bonding that involves 5f-electrons, however, is especially important, in part because of the significance of uranium and plutonium, but also because these elements are among the few where f-electron participation in bonding is relatively common. This work focused on studying uranium-containing and thorium-containing anions in the gas phase using negative ion photoelectron spectroscopy. Since this technique directly probed valence electrons, it was uniquely positioned to address open questions regarding molecular bonding and electron configurations. A particularly important issue concerned how bonding in actinide-containing molecules was affected by modifications to their actinide atoms’ environment, i.e., due to their interaction with ligands. A closely related question was how actinide atoms’ suborbitals were qualitatively reordered and their energies quantitatively shifted as a result of their ligated environments. These were especially relevant issues in regard to uranium due to it having multiple possible oxidation states (OS) and the potential for 5f electron participation in bonding. The effects of ligands on oxidation states and 5f-orbital energies in uranium bonding was expected to be pronounced. Both ligands and excess electrons were seen as probes of actinide atoms within actinide-containing molecules. Our strategy for advancing knowledge of chemical bonding in the actinide-containing species utilized the synergy between experiments and theory, where in some cases experimental results validated theory and where in others computational results assisted in interpreting experiments. Calculations on actinide systems are terrifically challenging due to large spin-orbit interactions, relativistic effects, and just the sheer number of electrons involved. Even in the simplest species, e.g., U and U2, the most sophisticated, modern calculations carried out by the most experienced theorists often only approximate experimentally-measured values, such as electron affinities. For theory to provide confident predictions that can be used to solve real problems it needed an iterative and ultimately corrective mechanism by which its methods can develop further. Experiments can be used to identify when theory has failed; whereupon the subsequent process of using the experiment-theory interplay can be used to find the cause of the failure. Upon fixing it in one case, different test species can be proposed and studied by the experiment-theory combination to determine whether the problem has been corrected. Thus, experiments not only measure the values of molecular properties, they also provide navigational 3 beacons that keep computations off the reefs in an otherwise dark sea with few reference points. Experimental measurements in the actinide field are not only important, they are in actuality essential to computational progress. While it was not always possible to compare the theoreticallydetermined quantity of interest directly with the same experimentally-measured observable, it was usually possible to compare consequential properties that are both calculable and measurable. In the work completed here electron affinities and electronic state spacings were often sensitive consequential parameters. Reasonable agreement between measured and computational values signaled that a calculation that was very likely to be on-track. We had established collaborative relationships with five computational groups, all of which have expertise in computational actinide chemistry. Their PI’s are L. Cheng, D. Dixon, L. Gagliardi, K. Peterson, and B. Vlaisavljevich. Our close interaction with our theory partners led to us suggesting systems to them and them to us. This reciprocal interaction between our experimental and their computational results was among the most important strengths of this work and was a thread woven throughout. Even though anion photoelectron spectroscopic studies are conducted on anions, much of the information that they provide, pertains to the electronic structure of the neutral counterparts of those anions; among these are electron affinities and electronically excited state spacings. Our experimental tools included several specialized ion sources for forming the anionic species of interest, a mass spectrometer for identifying and mass-selecting them, and an anion photoelectron spectrometer for determining their electron affinities (EA) and characterizing the electronic states of the selected anions’ neutral counterparts. Anion photoelectron spectroscopy is conducted by crossing a mass-selected beam of anions with a fixed-frequency laser beam and energy-analyzing the resultant photodetached electrons. The photodetachment process is governed by the energyconserving relationship: hν = EBE + EKE, where hν is the photon’s energy, EBE is the electron binding (photodetachment transition) energy, and EKE is the electron’s kinetic energy. In our apparatus mass-selection is accomplished via time-of-flight mass spectrometry (TOF-MS), electron energy analysis is achieved with either a magnetic bottle or by velocity mapped imaging. Photodetachment of electrons from anions is implemented via either Nd:YAG or excimer lasers. The photodetachment transition energy, i.e., the EBE, between the ground vibrational and electronic state of an anion and the ground vibrational and electronic state of that anion’s neutral counterpart is the adiabatic electron affinity (EA) of that neutral molecule. Likewise, photodetachment transitions between the ground vibrational and electronic state of an anion and the various electronically-excited states of that anion’s corresponding neutral map the electronic spectrum of that neutral species, i.e., the spectral spacings in the photoelectron spectrum are a mirror image of the neutral’s electronic spectrum. It was, of course, crucial to be able to form the anionic species of interest. There, we had a particularly broad field of anion sources from which to choose. These included several variants of pulsed laser vaporization (LV), laser photoemission, infrared desorption plus photoemission, pulsed arc discharge (PACIS), electrospray ionization (ESI), and Rydberg electron transfer (RET). Each of these anion sources were readily combined with, i.e., connected to, the anion photoelectron spectroscopic portion of our apparatus as described above. Among the sources that utilize lasers, visible light for LV sources as well as IR for desorption sources are provided by Nd:YAG lasers. Ultraviolet photons are provided by both Nd:YAG and excimer lasers, whereas the excitation wavelengths for RET experiments come from two Nd:YAG-pumped dye lasers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Hopfield Artificial Neural Network for Anomaly Detection in Environmental Gamma Radiation Background: Consortium on Nuclear Security Technologies (CONNECT) (Q2 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore supervised machine learning (ML) algorithms for development of a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm for detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Distorted Gamma-Ray Signature Patterns Using Digital Filtering and Auto-Associative Memory Implemented with a Hopfield Neural Network

The detection and identification of radioactive sources in search applications involve analyzing passive gamma-ray emissions from high-level radioactive materials. This process uses a mobile detector-spectrometer in a complex field test environment. Recently, the use of artificial intelligence for gamma-ray spectrum analysis has shown promising results. However, challenges persist in identifying isotopic signatures from spectral measurements that may be distorted due to source shielding, random variations in natural radioactive background, or insufficient measurement time to obtain clear spectral lines. Here, this paper presents a novel intelligent signature recognition method that combines digital filtering techniques with an artificial Hopfield Neural Network (HNN). The HNN leverages auto-associative memory to store training sample patterns and match them with incoming gamma spectra from distorted sources. It restores the testing sources’ measurements by finding the closest matching signature patterns in the spectral library. Before HNN recognition, the measured spectrum undergoes preprocessing with a digital image filter to reduce fluctuations. Performance of the proposed method is evaluated using a set of gamma-ray spectra measured with a sodium iodide detector. The data collected include measurements from six pure samples: 241 Am, 60 Co, 137 Cs, 192 Ir, 239 Pu, and 235 U, which are used for training and validation (i.e. six cases). Additionally, the data set contains 24 distorted synthesized sources with various fluctuating backgrounds. Test results demonstrate the potential of the proposed method to accurately recognize the correct isotope with high precision, achieving an accuracy rate exceeding 85%. Furthermore, the proposed method exhibits superior performance compared to the conventional multiple regression fitting and simple feedforward neural network methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CCAT-prime Collaboration: Science Goals and Forecasts with Prime-Cam on the Fred Young Submillimeter Telescope

Abstract We present a detailed overview of the science goals and predictions for the Prime-Cam direct-detection camera–spectrometer being constructed by the CCAT-prime collaboration for dedicated use on the Fred Young Submillimeter Telescope (FYST). The FYST is a wide-field, 6 m aperture submillimeter telescope being built (first light in late 2023) by an international consortium of institutions led by Cornell University and sited at more than 5600 m on Cerro Chajnantor in northern Chile. Prime-Cam is one of two instruments planned for FYST and will provide unprecedented spectroscopic and broadband measurement capabilities to address important astrophysical questions ranging from Big Bang cosmology through reionization and the formation of the first galaxies to star formation within our own Milky Way. Prime-Cam on the FYST will have a mapping speed that is over 10 times greater than existing and near-term facilities for high-redshift science and broadband polarimetric imaging at frequencies above 300 GHz. We describe details of the science program enabled by this system and our preliminary survey strategies.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of deeply virtual Compton scattering off 4 He with the CEBAF Large Acceptance Spectrometer at Jefferson Lab

We report on the measurement of the beam spin asymmetry in the deeply virtual Compton scattering off $^4$He using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab using a 6 GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target. We detail the method used to ensure the exclusivity of the measured reactions, in particular the upgrade of CLAS with a radial time projection chamber to detect the low-energy recoiling $^4$He nuclei and an inner calorimeter to extend the photon detection acceptance at forward angles. Our results confirm the theoretically predicted enhancement of the coherent ($e^4$He$~\to~e'$$^4$He$'\gamma'$) beam spin asymmetries compared to those observed on the free proton, while the incoherent ($e^4$He$~\to~e'$p$'\gamma'$X$'$) asymmetries exhibit a 30$\%$ suppression. From the coherent data, we were able to extract, in a model-independent way, the real and imaginary parts of the only $^4$He Compton form factor, $\cal H_A$, leading the way toward 3D imaging of the partonic structure of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient prediction of attosecond two-colour pulses from an X-ray free-electron laser with machine learning

Abstract X-ray free-electron lasers are sources of coherent, high-intensity X-rays with numerous applications in ultra-fast measurements and dynamic structural imaging. Due to the stochastic nature of the self-amplified spontaneous emission process and the difficulty in controlling injection of electrons, output pulses exhibit significant noise and limited temporal coherence. Standard measurement techniques used for characterizing two-coloured X-ray pulses are challenging, as they are either invasive or diagnostically expensive. In this work, we employ machine learning methods such as neural networks and decision trees to predict the central photon energies of pairs of attosecond fundamental and second harmonic pulses using parameters that are easily recorded at the high-repetition rate of a single shot. Using real experimental data, we apply a detailed feature analysis on the input parameters while optimizing the training time of the machine learning methods. Our predictive models are able to make predictions of central photon energy for one of the pulses without measuring the other pulse, thereby leveraging the use of the spectrometer without having to extend its detection window. We anticipate applications in X-ray spectroscopy using XFELs, such as in time-resolved X-ray absorption and photoemission spectroscopy, where improved measurement of input spectra will lead to better experimental outcomes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of X-ray event screening using ground and in-orbit data for the Resolve instrument onboard the XRISM satellite

The X-Ray Imaging and Spectroscopy Mission (XRISM) satellite was successfully launched and put into a low-Earth orbit on September 6, 2023 (UT). The Resolve instrument onboard XRISM hosts an X-ray microcalorimeter detector, which was designed to achieve a high-resolution ( ≤ 7 eV FWHM at 6 keV), high-throughput, and non-dispersive spectroscopy over a wide energy range. It also excels in a low background with a requirement of < 2 × 10 -3 s -1 keV -1 (0.3 to 12.0 keV), which is equivalent to only one background event per spectral bin per 100-ks exposure. Event screening to discriminate X-ray events from background is a key to meeting the requirement. We present the result of the Resolve event screening using data sets recorded on the ground and in orbit based on the heritage of the preceding X-ray microcalorimeter missions, in particular, the Soft X-ray Spectrometer onboard ASTRO-H. We optimize and evaluate 19 screening items of three types based on (1) the event pulse shape, (2) relative arrival times among multiple events, and (3) good time intervals. We show that the initial screening, which is applied for science data products in the performance verification phase, reduces the background rate to 1.8 × 10 -3 s -1 keV -1 meeting the requirement. We further evaluate the additional screening utilizing the correlation among some pulse shape properties of X-ray events and show that it further reduces the background rate, particularly in the < 2 keV band. Over 0.3 to 12 keV, the background rate becomes 1.0 × 10 -3 s -1 keV -1 .

47 OTHER INSTRUMENTATION↗