Search NASA⌕ Search

SEARCH · Search NASA

Results for “intensifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A photon-counting multichannel spectrometer

A multichannel detector system is described in which the positions of individual photon events in a high-gain image intensifier are decoded in the output of a video detector. The high-gain intensifier consists of a pair of three-stage electrostatic image-tube assemblies each containing three fiber-optically-coupled tubes potted in a rugged package with an internal high-voltage supply. Operation of the electrooptical system is discussed along with the pulse-detection process and the operation of the spectrograph in which the image-tube assembly is mounted. It is noted that the spectrometer detects 1.0 count/sec per A for an object of magnitude 13.0 at the peak of its response in the visual band when no light is lost on the slit, that a 10% coincidence correction is reached at an overall count rate of 860 per sec, and that the response follows an exponential law up to count rates of about 4000 per sec. The measured spectrum of the Seyfert galaxy NGC 5548 is provided as an example of the raw data produced by the instrument on a 1.5 meter telescope.

Shectman, S. A.↗

Charge coupled devices

The results are presented of a program to design, fabricate, and test CCD arrays suitable for operation in an electron-bombarded mode. These intensified charge coupled devices have potential application to astronomy as photon-counting arrays. The objectives of this program were to deliver arrays of 250 lines of 400 pixels each and some associated electronics. Some arrays were delivered on tube-compatible headers and some were delivered after incorporation in vacuum tubes. Delivery of these devices required considerable improvements to be made in the processing associated with intensified operation. These improvements resulted in a high yield in the thinning process, reproducible results in the accumulation process, elimination of a dark current source in the accumulation process, solution of a number of header related problems, and the identification of a remaining major source of dark current. Two systematic failure modes were identified and protective measures established. The effects of tube processing on the arrays in the delivered ICCDs were determined and are reported along with the characterization data on the arrays.

Walker, J. W.↗

Optical infrared sky survey

A description is presented of a photographic survey of the northern sky currently underway at Steward Observatory. The survey is being conducted at a principal bandpass of 8000-9000 A supplemented by a V bandpass. The survey is the first of its type conducted using a small (20-in. aperture) wide-field telescope, a very large-format (146 mm) image intensifier with a red-extended, multialkali photocathode. The output phosphor of the intensifier is photographed with IIaD emulsion on film. One of the goals of the survey is to catalog red stellar objects on the photographs and to examine in detail regions of the sky which are obscured by hydrogen emission on conventional photographs.

Craine, E. R.↗

A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

Hartig, G. F.↗

Tropical cyclone intensity change. A quantitative forecasting scheme

One to two day future tropical cyclone intensity change from both a composite and an individual case point-of-view are discussed. Tropical cyclones occurring in the Gulf of Mexico during the period 1957-1977 form the primary data source. Weather charts of the NW Atlantic were initially examined, but few differences were found between intensifying and non-intensifying cyclones. A rawinsonde composite analysis detected composite differences in the 200 mb height fields, the 850 mb temperature fields, the 200 mb zonal wind and the vertical shears of the zonal wind. The individual cyclones which make up the composite study were then separately examined using this composite case knowledge. Similar parameter differences were found in a majority of individual cases. A cyclone intensity change forecast scheme was tested against independent storm cases. Correct predictions of intensification or non-intensification could be made approximately 75% of the time.

Dropco, K. M.↗

Images of the future - Two decades in astronomy

Future instruments for the 100-10,000 A UV-wavelength region will require detectors with greater quantum efficiency, smaller picture elements, a greater wavelength range, and greater active area than those currently available. After assessing the development status and performance characteristics of vidicons, image tubes, electronographic cameras, digicons, silicon arrays and microchannel plate intensifiers presently employed by astronomical spacecraft, attention is given to such next-generation detectors as the Mosaicked Optical Self-scanned Array Imaging Camera, which consists of a photocathode deposited on the input side of a microchannel plate intensifier. The problems posed by the signal processing and data analysis requirements of the devices foreseen for the 21st century are noted.

Weistrop, D.↗

The measurements of vehicle glow on the Space Shuttle

From the combined data set of glow observations on STS-3, STS-4 and STS-5 some of the properties of the shuttle glow were observed. Comparison of the STS-3 (240 km) and STS-5 (305 km) photographs show that the intensity of the glow is about a factor of 3.5 brighter on the low altitude (STS-3) flight. The orbiter was purposely rotated about the x axis in an experiment on STS-5 to observe the dependence of the intensity on the angle of incidence between the spacecraft surface normal and the velocity vector. For a relatively large angle between the velocity vector and the surface normal there is an appreciable glow, provided the surface is not shadowed by some other spacecraft structure. As the angle becomes less the glow intensifies. The grating experiments (STS-4 photography only, STS-5 image intensifier photography) provided a preliminary low resolution spectra of the spacecraft glow. Accurate wavelength calibrations of the STS-5 instrument permitted measuring of the spectrum and intensity of the Earth's airglow.

Mende, S. B.↗

Spiky ion acoustic waves in collisionless auroral plasma

A theory of spiky electric fields in 'inverted V' precipitation regions is elaborated and compared with recent spacecraft observations of solitary waves and double layers. A prediction from the theory is that the electric fields propagate along the magnetic field as perturbed ion acoustic solitons that intensify by exchanging momentum with reflected particles. The solitons have minimum scale lengths of approximately 100 m and maximum electric potential and field amplitudes of 1-10 V and 1-10 mV/m. They propagate at the local ion acoustic speed and are Doppler-shifted by the drift speed of upward flowing cold ions. Both rarefactive and compressive solitons with, respectively, negative and positive electric potentials are possible. It is noted that upward propagating compressive modes intensify when the upward flow of ionospheric ions exceeds approximately 10 times the local ion acoustic speed. The kinematic and dynamic properties of rarefactive solitons are found to be consistent with recent observations.

Lotko, W.↗

Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

Hartig, G. F.↗

Measurement of vehicle glow on the Space Shuttle

From the combined data set of glow observations on STS-3, STS-4 and STS-5 some of the properties of the Shuttle glow were observed. Comparison of the STS-3 (240 km) and STS-5 (305 km) photographs show that the intensity of the glow is about a factor of 3.5 brighter on the low altitude (STS-3) flight. The orbiter was purposely rotated about the x axis in an experiment on STS-5 to observe the dependence of the intensity on the angle of incidence between the spacecraft surface normal and the velocity vector. For a relatively large angle between the velocity vector and the surface normal there is an appreciable glow, provided the surface is not shadowed by some other spacecraft structure. As the angle becomes less the glow intensifies. The grating experiments (STS-4 photography only, STS-5 image intensifier photography) provided a preliminary low resolution spectra of the spacecraft glow. Accurate wavelength calibrations of the STS-5 instrument permitted measuring of the spectrum and intensity of the earth's airglow. Previously cited in STAR as N83-30509

Mende, S. B.↗

Observation of orbiting vehicle induced luminosities on the STS-8 mission

Image-intensified photographic observations of vehicle glow from the STS-8 Space Shuttle mission are discussed. An objective grating spectrometer preceding a camera was used to measure the intensity of the glow. It is found that glow intensity is dependent on the nature of the vehicle material. With limited resolution of the objective spectrum vehicle glow appeared as a continuum emission. The intensity of the glow from the tail of the vehicle became detectable at 4600 A and increased toward the red. Between 7000 and 8000 A, a slight decrease in the glow intensity is inferred. The absolute intensity of the obliquely viewed tail glow was measured at 450 Rayleighs per Angstrom at 7000 A and 1 MR in the range within the transmission band of the image intensifier camera. The spectral distribution is found to be in agreement with measurements taken from the atmospheric explorer satellite. Samples of the photographic data are provided.

Mende, S. B.↗

Measurements of vehicle glow on the Space Shuttle

From the combined data set of glow observations on STS-3, STS-4 and STS-5 some of the properties of the Shuttle glow were observed. Comparison of the STS-3 (240 km) and STS-5 (305 km) photographs show that the intensity of the glow is about a factor of 3.5 brighter on the low altitude (STS-3) flight. The orbiter was purposely rotated about the x axis in an experiment on STS-5 to observe the dependence of the intensity on the angle of incidence between the spacecraft surface normal and the velocity vector. For a relatively large angle between the velocity vector and the surface normal there is an appreciable glow, provided the surface is not shadowed by some other spacecraft structure. As the angle becomes less the glow intensifies. The grating experiments (STS-4 photography only, STS-5 image intensifier photography) provided a preliminary low resolution spectra of the spacecraft glow. Accurate wavelength calibrations of the STS-5 instrument permitted measuring of the spectrum and intensity of the earth's airglow.

Mende, S. B.↗

STS atmospheric luminosities

During the STS-8 space shuttle mission special photographic and TV operations were carried out to record the properties of the spacecraft induced luminosities. One of these luminous phenomena is the quiescent vehicle glow which was photographed during the STS-8 mission with an image intensified photographic camera, with and without an objective grating. During the latter part of the mission the altitude of the shuttle was relatively low (120 n.m. = 222 km) and unprecedentedly high intensity of the glow was observed. The crew reported that the glow was easily visible to the naked eye. The proper orientation of the shuttle with respect to the velocity vector and the objective grating permitted the exposure of good objective spectrum of the glow in the visible region. From the results it is clear that the spectrum appears to be a continuum as observed by the image intensifier objective grating camera. Qualitative examination of the data shows that there is very tail little glow ion the wavelength range of 4300 to about 5000 angstroms. Above 5000 angstroms the glow becomes stronger towards the red and then it falls off towards higher wavelength and of the spectrum presumably because of the responsivity of the device.

Mende, S. B.↗

Three-dimensional and tomographic imaging device for X-ray and gamma-ray emitting objects

An instrument for obtaining quantitative, three-dimensional and tomographic information relating to X-ray and gamma-ray emitting objects and for the orthoscopic viewing of such objects includes a multiple-pinhole aperture plate held spaced from an X-ray or gamma-ray to visible-light converter which is coupled to a visible-light image intensifier. The spacing between the aperture plate and the converter is chosen such that the mini-images of an emitting object formed by the pinholes do not substantially overlap as they impinge on the converter. The output of the image intensifier is digitized by a digitizing camera in terms of position and intensity and fed into a digital computer. The computer may output quantitative information relating to the emitting object directly, such as that relating to tomograms, or provide information in analogue form when coupled with a suitable viewing device to give an orthoscopic, three-dimensional image of the object.

Yin, L. I.↗

Aspects of the 40-50 day oscillation during the northern winter as inferred from outgoing longwave radiation

One-point correlation statistics and extended empirical orthogonal function analysis are used to show the existence of a principal mode of oscillation in the intraseasonal variability (ISV) of tropical convection. The data analyzed were derived from NOAA Outgoing Longwave Radiation data covering seven 6 mo periods from 1974-83. The data is filtered to remove fluctuations on time scales under 5 days and by subtracting a least-squares parabola to eliminate seasonal means. The previously-known 40-50 day oscillation is found to be the most prevalent component of the ISV of tropical convection. An E-W dipole forms and propagates over the equatorial Indian Ocean, then stalls and intensifies over Indonesia and the equatorial Indian Ocean, then stalls and intensifies over Indonesia and the equatorial central Pacific. Various anomalies generated in association with the dipole and dependent on its exact location when stalled are discussed.

Lau, K.-M.↗

High speed photography, videography, and photonics III; Proceedings of the Meeting, San Diego, CA, August 22, 23, 1985

Papers are presented on the picosecond electronic framing camera, photogrammetric techniques using high-speed cineradiography, picosecond semiconductor lasers for characterizing high-speed image shutters, the measurement of dynamic strain by high-speed moire photography, the fast framing camera with independent frame adjustments, design considerations for a data recording system, and nanosecond optical shutters. Consideration is given to boundary-layer transition detectors, holographic imaging, laser holographic interferometry in wind tunnels, heterodyne holographic interferometry, a multispectral video imaging and analysis system, a gated intensified camera, a charge-injection-device profile camera, a gated silicon-intensified-target streak tube and nanosecond-gated photoemissive shutter tubes. Topics discussed include high time-space resolved photography of lasers, time-resolved X-ray spectrographic instrumentation for laser studies, a time-resolving X-ray spectrometer, a femtosecond streak camera, streak tubes and cameras, and a short pulse X-ray diagnostic development facility.

Ponseggi, B. G.↗

Imaging spectrometer for high resolution measurements of stratospheric trace constituents in the ultraviolet

A high-resolution spectrometer has been developed for studies of minor constituents in the middle atmosphere at ultraviolet wavelengths. In particular, the instrument is intended for observations of upper stratospheric UV bands. The spectrometer has a slit width of 0.08 A obtained by means of an echelle grating and a cross-disperser grating. The image plane detector is an intensified CCD consisting of a high gain proximity focused image intensifier that is fiber optically coupled to a two-dimensional CCD array. An instantaneous bandwidth of 9.2 A is resolved across 488 pixels at 0.018 A/pixel, permitting simultaneous acquisition of multiple lines of selected OH bands and the neighboring background. The spectrometer and the approach have been successfully demonstrated as a technique for measuring the concentration of OH on two high-altitude balloon flights. This paper reports the instrument design and its achieved performance.

Torr, Marsha R.↗

Helicopter flights with night-vision goggles: Human factors aspects

Night-vision goggles (NVGs) and, in particular, the advanced, helmet-mounted Aviators Night-Vision-Imaging System (ANVIS) allows helicopter pilots to perform low-level flight at night. It consists of light intensifier tubes which amplify low-intensity ambient illumination (star and moon light) and an optical system which together produce a bright image of the scene. However, these NVGs do not turn night into day, and, while they may often provide significant advantages over unaided night flight, they may also result in visual fatigue, high workload, and safety hazards. These problems reflect both system limitations and human-factors issues. A brief description of the technical characteristics of NVGs and of human night-vision capabilities is followed by a description and analysis of specific perceptual problems which occur with the use of NVGs in flight. Some of the issues addressed include: limitations imposed by a restricted field of view; problems related to binocular rivalry; the consequences of inappropriate focusing of the eye; the effects of ambient illumination levels and of various types of terrain on image quality; difficulties in distance and slope estimation; effects of dazzling; and visual fatigue and superimposed symbology. These issues are described and analyzed in terms of their possible consequences on helicopter pilot performance. The additional influence of individual differences among pilots is emphasized. Thermal imaging systems (forward looking infrared (FLIR)) are described briefly and compared to light intensifier systems (NVGs). Many of the phenomena which are described are not readily understood. More research is required to better understand the human-factors problems created by the use of NVGs and other night-vision aids, to enhance system design, and to improve training methods and simulation techniques.

Brickner, Michael S.↗