Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion insertion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

208 records · Page 12

Space Nuclear Propulsion for Deep Space Science Missions

The use of nuclear thermal propulsion (NTP) 1 and nuclear electric propulsion (NEP) 2 systems on deep space science missions to the outer planets and into the interstellar medium 3 can yield significant spacecraft system and mission performance benefits and improvements relative to the use of conventional chemical propulsion systems. Several recent and ongoing programs are developing the technologies and systems required to realize a near-term deep space nuclear propulsion capability. NTP provides improved propulsion efficiencies compared to chemical propulsion, while also providing substantial thrust. This combination of high thrust and increased specific impulse (I_sp) provides high acceleration and extended thrusting periods, enabling greatly reduced trip-times on certain types of missions compared to various propulsive alternatives. For examples, compared to a baseline mission using chemical propulsion, NTP-powered missions to Jupiter or Uranus could deliver approximately 2.4-3.6 times more payload (in the case of Jupiter, the payload delivery is significantly larger than the Juno spacecraft). In this comparison, the higher end of the payload advantage is obtained when the trip time is held equal for the NTP-powered vehicle and a vehicle using a chemical propulsion departure stage. NTP systems are presently under development by multiple government agencies. NASA’s Space Nuclear Propulsion (SNP) project aims to demonstrate a hydrogen-fed NTP engine at 900 s specific impulse (I_sp) and approximately 10-15 klb_f of thrust. DARPA’s Demonstration Rocket for Agile Cislunar Operations (DRACO) program is targeting a demonstration of an NTP system in the cislunar space between the Earth and the Moon. An appropriately phased development plan that applies the development of the reactor technology for an NTP engine in this performance class and leverages mature, existing liquid rocket component hardware provides a path to a lower cost propulsion system that can be realized on a shorter development schedule. NEP, with high Isp in the 2,000-8,000 s range, can also provide advantages over chemical propulsion, including a much greater payload delivery mass and the flexibility for planners to trade between delivered mass and a wider window of mission trajectory options. Electric propulsion (EP) systems have demonstrated great utility, performing notably on the Dawn mission to enable rendezvous and orbital insertion at two separate bodies, Vesta and Ceres. An NEP-powered vehicle would have a similar capability to visit multiple bodies, loitering at each before moving to the next. A 10 kW_e NEP system provides a power- rich environment on the spacecraft that is simply not possible using present radioisotope power systems, giving mission planners more scientific instrument and communication hardware options. Several programs and projects are presently developing NEP systems and subsystems in the 10 kW_e power range, leveraging past reactor work and recent nuclear power generation risk-reduction demonstration activities such as the Demonstration Using Flattop Fission (DUFF) and the Kilopower Reactor Using Stirling TechnologY (KRUSTY). The goal of the Air Force Research Laboratory’s Joint Energy Technology Supplying On-Orbit Nuclear Power (JETSON) program is an in-space demonstration vehicle that has a 10 kW_e -class fission power source. These past and present efforts can be combined with the ongoing development of 10 kW_e -class electric propulsion systems (notably the NEXT-C ion thruster or the Hall-effect thrusters for Power and Propulsion Element of the Lunar Gateway) to provide a pathway to a low-cost, reliable NEP system for deep space science application.

Kurt A. Polzin↗

Space Nuclear Propulsion for Deep Space Science Missions

The use of nuclear thermal propulsion (NTP) 1 and nuclear electric propulsion (NEP) 2 systems on deep space science missions to the outer planets and into the interstellar medium 3 can yield significant spacecraft system and mission performance benefits and improvements relative to the use of conventional chemical propulsion systems. Several recent and ongoing programs are developing the technologies and systems required to realize a near-term deep space nuclear propulsion capability. NTP provides improved propulsion efficiencies compared to chemical propulsion, while also providing substantial thrust. This combination of high thrust and increased specific impulse (I_sp) provides high acceleration and extended thrusting periods, enabling greatly reduced trip-times on certain types of missions compared to various propulsive alternatives. For examples, compared to a baseline mission using chemical propulsion, NTP-powered missions to Jupiter or Uranus could deliver approximately 2.4-3.6 times more payload (in the case of Jupiter, the payload delivery is significantly larger than the Juno spacecraft). In this comparison, the higher end of the payload advantage is obtained when the trip time is held equal for the NTP-powered vehicle and a vehicle using a chemical propulsion departure stage. NTP systems are presently under development by multiple government agencies. NASA’s Space Nuclear Propulsion (SNP) project aims to demonstrate a hydrogen-fed NTP engine at 900 s specific impulse (I_sp) and approximately 10-15 klb_f of thrust. DARPA’s Demonstration Rocket for Agile Cislunar Operations (DRACO) program is targeting a demonstration of an NTP system in the cislunar space between the Earth and the Moon. An appropriately phased development plan that applies the development of the reactor technology for an NTP engine in this performance class and leverages mature, existing liquid rocket component hardware provides a path to a lower cost propulsion system that can be realized on a shorter development schedule. NEP, with high Isp in the 2,000-8,000 s range, can also provide advantages over chemical propulsion, including a much greater payload delivery mass and the flexibility for planners to trade between delivered mass and a wider window of mission trajectory options. Electric propulsion (EP) systems have demonstrated great utility, performing notably on the Dawn mission to enable rendezvous and orbital insertion at two separate bodies, Vesta and Ceres. An NEP-powered vehicle would have a similar capability to visit multiple bodies, loitering at each before moving to the next. A 10 kW_e NEP system provides a power- rich environment on the spacecraft that is simply not possible using present radioisotope power systems, giving mission planners more scientific instrument and communication hardware options. Several programs and projects are presently developing NEP systems and subsystems in the 10 kW_e power range, leveraging past reactor work and recent nuclear power generation risk-reduction demonstration activities such as the Demonstration Using Flattop Fission (DUFF) and the Kilopower Reactor Using Stirling TechnologY (KRUSTY). The goal of the Air Force Research Laboratory’s Joint Energy Technology Supplying On-Orbit Nuclear Power (JETSON) program is an in-space demonstration vehicle that has a 10 kW_e -class fission power source. These past and present efforts can be combined with the ongoing development of 10 kW_e -class electric propulsion systems (notably the NEXT-C ion thruster or the Hall-effect thrusters for Power and Propulsion Element of the Lunar Gateway) to provide a pathway to a low-cost, reliable NEP system for deep space science application.

Kurt A. Polzin↗

Miniature Trace Gas Detector Based on Microfabricated Optical Resonators

While a variety of techniques exist to monitor trace gases, methods relying on absorption of laser light are the most commonly used in terrestrial applications. Cavity-enhanced absorption techniques typically use high-reflectivity mirrors to form a resonant cavity, inside of which a sample gas can be analyzed. The effective absorption length is augmented by the cavity's high quality factor, or Q, because the light reflects many times between the mirrors. The sensitivity of such mirror-based sensors scales with size, generally making them somewhat bulky in volume. Also, specialized coatings for the high-reflectivity mirrors have limited bandwidth (typically just a few nanometers), and the delicate mirror surfaces can easily be degraded by dust or chemical films. As a highly sensitive and compact alternative, JPL is developing a novel trace gas sensor based on a monolithic optical resonator structure that has been modified such that a gas sample can be directly injected into the cavity. This device concept combines ultra-high Q optical whispering gallery mode resonators (WGMR) with microfabrication technology used in the semiconductor industry. For direct access to the optical mode inside a resonator, material can be precisely milled from its perimeter, creating an open gap within the WGMR. Within this open notch, the full optical mode of the resonator can be accessed. While this modification may limit the obtainable Q, calculations show that the reduction is not significant enough to outweigh its utility for trace gas detection. The notch can be milled from the high- Q crystalline WGMR with a focused ion beam (FIB) instrument with resolution much finer than an optical wavelength, thereby minimizing scattering losses and preserving the optical quality. Initial experimental demonstrations have shown that these opened cavities still support high-Q whispering gallery modes. This technology could provide ultrasensitive detection of a variety of molecular species in an extremely compact and robust package. With this type of modified WGMR, one can inject a gas sample into the open gap, allowing highly sensitive trace molecule detection within a roughly 1-cm volume. Other critical components of the instrument, such as the detector and a semiconductor laser, could be directly packaged with the resonator so as to not significantly increase the size of the device. Besides its low mass, volume, and power consumption, the monolithic design makes these resonators intrinsically robust devices, capable of handling significant temperature excursions, without moving parts to wear out or delicate coatings that can be easily damaged. A sensor could integrate with microfluidics technology for a chip-scale device. It could be mounted to the end of a deployable arm, or inserted into a borehole. Also, a network of individual sensors could be dispersed to monitor conditions over a wide region

Aveline, David C.↗

Alleviating Bundle Throughput Constriction for Delay Tolerance Networking (DTN) Bundles with Software-Defined Networking (SDN)

A load-balancing technique is proposed, executed, and tested against a Delay Tolerant Network (DTN) implementation with well-known characteristics. This would prove that transparently inserting software defined networking (SDN) to achieve load balancing without re-configuring the DTN portion is possible. Two routes were taken to alleviate a DTN bottleneck threat. The first used a P4 networking switch. This manual load-balancing test will balance the incoming packets without the users at the end-points knowing that its original packet destination and/or source may have been changed. The second route utilized a High-rate Delay Tolerant Networking (HDTN) receiving node instead of the typical the delay tolerance networking (DTN) implementation used. Bench-marking results of the DTN implementation receiving node and the HDTN receiving node will be compared.

Delay Tolerant Networking (DTN)↗

The Atmosphere-Space Transition Region Explorer (ASTRE) – A Low Perigee Satellite to Investigate the Coupling of the Earth’s Upper Atmosphere and Magnetosphere

The Atmosphere-Space Transition Region Explorer (ASTRE) is a mission concept designed to carry out an unprecedented study of the interaction between the Earth’s atmosphere and the ionized gases of space within the atmosphere-space transition region. By gathering direct measurements of the coupling of ion and neutral gases in this region, ASTRE provides the critical missing link in our knowledge of the transfer, dissipation, and regulation of energy and momentum between the sun and the upper atmosphere. ASTRE provides the first detailed, systematic investigation of this important unexplored region, vastly improves and constrains models of the upper atmosphere, and fills a critical gap in our understanding of how the coupled lower ionosphere/upper atmosphere “works” as a system. To achieve its science objectives, ASTRE gathers accurate measurements of plasma and neutral gases, electric and magnetic fields, and energetic particles using well-proven, in situ instruments with excellent flight heritage. Furthermore, as described herein, all the instruments have been designed to perform well in the low perigee environment, including altitudes of 150 km and lower. ASTRE utilizes a three-axis stabilized satellite that uses on-board propulsion to carry out systematic, low perigee measurements at high latitudes. The satellite design incorporates a “form follows function” approach with a cylindrical shape and conductive body-mounted solar arrays to minimize drag and perturbations to the space environment. Atomic-oxygen resistant materials are utilized and a passive thermal design with heat pipes and radiator panels minimizes the impact of aero-heating. ASTRE launches into a 250 km × 1500 km elliptical insertion orbit with an inclination of 83°. Perigee precesses from its highest northern latitude to its highest southern latitude every ~60 days. Hydrazine propulsion provides over 2000 orbits with perigee below 200 km, with a significant fraction as low as 150 km, during high latitude, two-week campaigns when perigee precesses to either the northern or southern high latitude region. At mid and low latitudes, the perigee is near 225 km. Because very conservative assumptions were made with respect to the orbital analysis and drag, including continuous 3-sigma “worst-case” solar flux and atmospheric density, when additional propellant is included (accommodated in the current design) and some of the stringent assumptions are relaxed, the ASTRE mission described herein may be expected to include repeated excursions to altitudes of ~130 km or even lower. This paper presents an overview of the ASTRE mission, its science motivation, and objectives. It includes a discussion of the science-driven requirements and traceability, followed by a “proof-of concept” implementation that includes notional instruments and a straightforward spacecraft design. Three key points are demonstrated: 1) There is a critical knowledge gap in the high latitude, atmosphere-space transition region below 250 km; 2) The instrument and measurement techniques needed to obtain the ASTRE measurements are well-proven and function well in the low-altitude environment; and 3) A mature spacecraft design, flight dynamics analysis, and concept of operations have been developed that demonstrate that the ASTRE mission can be achieved in a straightforward manner using current technologies.

Ionosphere↗

Stress-Driven Selection of Novel Phenotypes

A process has been developed that can confer novel properties, such as metal resistance, to a host bacterium. This same process can also be used to produce RNAs and peptides that have novel properties, such as the ability to bind particular compounds. It is inherent in the method that the peptide or RNA will behave as expected in the target organism. Plasmid-born mini-gene libraries coding for either a population of combinatorial peptides or stable, artificial RNAs carrying random inserts are produced. These libraries, which have no bias towards any biological function, are used to transform the organism of interest and to serve as an initial source of genetic variation for stress-driven evolution. The transformed bacteria are propagated under selective pressure in order to obtain variants with the desired properties. The process is highly distinct from in vitro methods because the variants are selected in the context of the cell while it is experiencing stress. Hence, the selected peptide or RNA will, by definition, work as expected in the target cell as the cell adapts to its presence during the selection process. Once the novel gene, which produces the sought phenotype, is obtained, it can be transferred to the main genome to increase the genetic stability in the organism. Alternatively, the cell line can be used to produce novel RNAs or peptides with selectable properties in large quantity for separate purposes. The system allows for easy, large-scale purification of the RNAs or peptide products. The process has been reduced to practice by imposing sub-inhibitory concentrations of NiCl2 on cells of the bacterium Escherichia coli that were transformed separately with the peptide library and RNA library. The evolved resistant clones were isolated, and sequences of the selected mini-gene variants were established. Clones resistant to NiCl2 were found to carry identical plasmid variants with a functional mini-gene that specifically conferred significant nickel tolerance on the host cells. Sequencing of the selected mini-gene revealed a propensity of the encoded peptide to bind transient metal ions. Expression of the mini-gene markedly improved growth parameters of the evolved clones at sub-inhibitory concentrations of NiCl2 while being slightly detrimental in the absence of stress. Similar results have been obtained with the RNA libraries. Overall, the results demonstrate a very natural outcome of the selection experiments in which the mini-genes were expected to be either successfully integrated into bacterial genetic networks, or rejected depending upon their effect on host fitness. This described approach can be useful as a laboratory model to study the dynamics of bacterial adaptive evolution on the molecular level. It can also provide a strategy for screening expressed DNA libraries in search of novel genes with desirable properties.

Fox, George E.↗

MESSENGER at Mercury: Early Orbital Operations

The MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft, launched in August 2004 under NASA's Discovery Program, was inserted into orbit about the planet Mercury in March 2011. MESSENGER's three flybys of Mercury in 2008-2009 marked the first spacecraft visits to the innermost planet since the Mariner 10 flybys in 1974-1975. The unprecedented orbital operations are yielding new insights into the nature and evolution of Mercury. The scientific questions that frame the MESSENGER mission led to the mission measurement objectives to be achieved by the seven payload instruments and the radio science experiment. Interweaving the full set of required orbital observations in a manner that maximizes the opportunity to satisfy all mission objectives and yet meet stringent spacecraft pointing and thermal constraints was a complex optimization problem that was solved with a software tool that simulates science observations and tracks progress toward meeting each objective. The final orbital observation plan, the outcome of that optimization process, meets all mission objectives. MESSENGER's Mercury Dual Imaging System is acquiring a global monochromatic image mosaic at better than 90%coverage and at least 250 m average resolution, a global color image mosaic at better than 90%coverage and at least 1 km average resolution, and global stereo imaging at better than 80%coverage and at least 250 m average resolution. Higher-resolution images are also being acquired of targeted areas. The elemental remote sensing instruments, including the Gamma-Ray and Neutron Spectrometer and the X-Ray Spectrometer, are being operated nearly continuously and will establish the average surface abundances of most major elements. The Visible and Infrared Spectrograph channel of MESSENGER's Mercury Atmospheric and Surface Composition Spectrometer is acquiring a global map of spectral reflectance from 300 to 1450 nm wavelength at a range of incidence and emission angles. Targeted areas have been selected for spectral coverage into the ultraviolet with the Ultraviolet and Visible Spectrometer (UVVS). MESSENGER's Mercury Laser Altimeter is acquiring topographic profiles when the slant range to Mercury's surface is less than 1800 km, encompassing latitudes from 201S to the north pole. Topography over the remainder of the southern hemisphere will be derived from stereo imaging, radio occultations, and limb profiles. MESSENGER's radio science experiment is determining Mercury's gravity field from Doppler signals acquired during frequent downlinks. MESSENGER's Magnetometer is measuring the vector magnetic field both within Mercury's magnetosphere and in Mercury's solar wind environment at an instrument sampling rate of up to 20 samples/s. The UVVS is determining the three-dimensional, time-dependent distribution of Mercury's exospheric neutral and ionic species via their emission lines. During each spacecraft orbit, the Energetic Particle Spectrometer measures energetic electrons and ions, and the Fast Imaging Plasma Spectrometer measures the energies and mass per charge of thermal plasma components, both within Mercury's magnetosphere and in Mercury's solar-wind environment. The primary mission observation sequence will continue for one Earth year, until March 2012. An extended mission, currently under discussion with NASA, would add a second year of orbital observations targeting a set of focused follow-on questions that build on observations to date and take advantage of the more active Sun expected during 2012-2013. MESSENGER's total primary mission cost, projected at $446 M in real-year dollars, is comparable to that of Mariner 10 after adjustment for inflation.

Planetary Science↗

MESSENGER at Mercury: Early Orbital Operations

The MErcury Surface, Space ENvironment, GEochemistry, and Ranging (MESSENGER) spacecraft, launched in August 2004 under NASA's Discovery Program, was inserted into orbit about the planet Mercury in March 2011. MESSENGER's three flybys of Mercury in 2008-2009 marked the first spacecraft visits to the innermost planet since the Mariner 10 flybys in 1974-1975. The unprecedented orbital operations are yielding new insights into the nature and evolution of Mercury. The scientific questions that frame the MESSENGER mission led to the mission measurement objectives to be achieved by the seven payload instruments and the radio science experiment. Interweaving the full set of required orbital observations in a manner that maximizes the opportunity to satisfy all mission objectives and yet meet stringent spacecraft pointing and thermal constraints was a complex optimization problem that was solved with a software tool that simulates science observations and tracks progress toward meeting each objective. The final orbital observation plan, the outcome of that optimization process, meets all mission objectives. MESSENGER's Mercury Dual Imaging System is acquiring a global monochromatic image mosaic at better than 90% coverage and at least 250 m average resolution, a global color image mosaic at better than 90% coverage and at least 1 km average resolution, and global stereo imaging at better than 80% coverage and at least 250 m average resolution. Higher-resolution images are also being acquired of targeted areas. The elemental remote sensing instruments, including the Gamma-Ray and Neutron Spectrometer and the X-Ray Spectrometer, are being operated nearly continuously and will establish the average surface abundances of most major elements. The Visible and Infrared Spectrograph channel of MESSENGER's Mercury Atmospheric and Surface Composition Spectrometer is acquiring a global map of spectral reflectance from 300 to 1450 nm wavelength at a range of incidence and emission angles. Targeted areas have been selected for spectral coverage into the ultraviolet with the Ultraviolet and Visible Spectrometer (UVVS). MESSENGER's Mercury Laser Altimeter is acquiring topographic profiles when the slant range to Mercury's surface is less than 1800 km, encompassing latitudes from 20 deg. S to the north pole. Topography over the remainder of the southern hemisphere will be derived from stereo imaging, radio occultations, and limb profiles. MESSENGER's radio science experiment is determining Mercury's gravity field from Doppler signals acquired during frequent downlinks. MESSENGER's Magnetometer is measuring the vector magnetic field both within Mercury's magnetosphere and in Mercury's solar wind environment at an instrument sampling rate of up to 20 samples/s. The UVVS is determining the three-dimensional, time-dependent distribution of Mercury's exospheric neutral and ionic species via their emission lines. During each spacecraft orbit, the Energetic Particle Spectrometer measures energetic electrons and ions, and the Fast Imaging Plasma Spectrometer measures the energies and mass per charge of thermal plasma components, both within Mercury's magnetosphere and in Mercury's solar-wind environment. The primary mission observation sequence will continue for one Earth year, until March 2012. An extended mission, currently under discussion with NASA, would add a second year of orbital observations targeting a set of focused follow-on questions that build on observations to date and take advantage of the more active Sun expected during 2012-2013. MESSENGER's total primary mission cost, projected at $446 M in real-year dollars, is comparable to that of Mariner 10 after adjustment for inflation.

mercury↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗