Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface modification using low energy ground state ion beams

A method of effecting modifications at the surfaces of materials using low energy ion beams of known quantum state, purity, flux, and energy is presented. The ion beam is obtained by bombarding ion-generating molecules with electrons which are also at low energy. The electrons used to bombard the ion generating molecules are separated from the ions thus obtained and the ion beam is directed at the material surface to be modified. Depending on the type of ion generating molecules used, different ions can be obtained for different types of surface modifications such as oxidation and diamond film formation. One area of application is in the manufacture of semiconductor devices from semiconductor wafers.

Chutjian, Ara↗

Observational Evidence of Magnetic Reconnection in the Terrestrial Bow Shock Transition Region

We report evidence of magnetic reconnection in the transition region of the Earth's bow shock when the angle between the shock normal and the immediate upstream magnetic field is 65°. An ion‐skin‐depth‐scale current sheet exhibits the Hall current and field pattern, electron outflow jet, and enhanced energy conversion rate through the nonideal electric field, all consistent with a reconnection diffusion region close to the X‐line. In the diffusion region, electrons are modulated by electromagnetic waves. An ion exhaust with energized field‐aligned ions and electron parallel heating are observed in the same shock transition region. The energized ions are more separated from the inflowing ions in velocity above the current sheet than below, possibly due to the shear flow between the two inflow regions. The observation suggests that magnetic reconnection may contribute to shock energy dissipation.

Wang, Shan↗

Influence of ion-pairing reagents on the separation of intact glycoproteins using hydrophilic-interaction liquid chromatography - high-resolution mass spectrometry

Hydrophilic-interaction liquid chromatography (HILIC) of intact proteins offers high-resolution separations of glycoforms of glycoproteins differing in the number of (neutral) glycans. However, to obtain efficient separations it is essential that the positively charged sites of the proteins are shielded by acidic (negative) ion-pair reagents (IPRs), so as to enhance the contribution of the hydroxyl groups of the (neutral) sugars in the glycoprotein. Here, we studied the influence of various IPRs that differ in physico-chemical properties, such as hydrophobicity and acidity, on the capillary-scale HILIC separation of intact (glyco)proteins. We evaluated the use of fluoroacetic acid (MFA), difluoroacetic acid (DFA), trifluoroacetic acid (TFA), and heptafluorobutyric acid (HFBA) as diluents for sample preparation, as solvents for sample loading on a reversed-phase trap prior to the HILIC separation, and as mobile-phase components for HILIC and HILIC-MS. To reduce the contribution of ion-exchange interaction with the (silica-based) stationary phase, we used an acrylamide-based monolithic column. We studied the influence of the different IPRs on each step of the separation of a mixture of proteins of different size and hydrophilicity and on the separation of the five glycoforms of ribonuclease B. The content of IPR in the sample was shown not to affect the separation and the MS detection. However, a low content of TFA and DFA in the mobile phase is favourable, as it reduces adduct formation and leads to higher signal intensity. The optimized HILIC conditions successfully resolved nine major glycoforms groups of a ~40 kDa glycoprotein horseradish peroxidase (HRP), as an example of a complex glycoprotein.

59 BASIC BIOLOGICAL SCIENCES↗

Convenient Confinement: Interplay of Solution Conditions and Graphene Oxide Film Structure on Rare Earth Separations

Graphene oxide (GO) membranes are excellent candidates for a range of separation applications, including rare earth segregation and radionuclide decontamination. Understanding nanoscale water and ion behavior near interfacial GO is critical for groundbreaking membrane advances, including improved selectivity and permeability. Here, we experimentally examine the impact of solution conditions on water and lanthanide interactions with interfacial GO films and connect these results to GO membrane performance. The investigation of the confined films at the air–water interface with a combination of surface-specific spectroscopy and X-ray scattering techniques allows us to understand water and ion behaviors separately. Sum frequency generation spectroscopy reveals a dramatic change in interfacial water organization because of graphene oxide film deprotonation. Interfacial X-ray fluorescence measurements show a 17× increase in adsorbed lanthanide to the GO film from subphase pH 3 to pH 9. Liquid surface X-ray reflectivity data show an additional 2.7 $e^–$ per Å 2 for GO films at pH 9 versus pH 3 as well. These results are connected to GO membrane performance, which show increased selectivity and decreased flux for membranes filtering pH 9 solutions. We posit insoluble lanthanide hydroxides form at higher pHs. Taken together, these results highlight the importance of interfacial experiments on model GO systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quadrupole mass filter with means to generate a noise spectrum exclusive of the resonant frequency of the desired ions to deflect stable ions

A mass spectrometer for the separation or separate indication of ions of different specific electric charges is reported. The instrument uses a periodically varying electric field in its analyzing section to excite the injected ions into oscillations while traveling along their trajectories which are either stable or unstable depending on specific parameters. Only stable trajectory ions pass through the electric field to the collector for indication.

Langmuir, R. V.↗

Activation parameters of flow through battery separators

Studies of the hydrodynamic flow of water and 45 percent potassium hydroxide (KOH) solution through a microporous and an ion exchange separator are described. The permeability values are interpreted in terms of a pseudoactivation process. The enthalpy of activation deltaH* and the entropy of activation deltaS* were estimated from Eyring's rate equation.

Blokhra, R. L.↗

Sputtering of Metals by Mass-Analyzed N2(+) and N(+)

Low-energy sputtering studies were conducted with the help of a specially designed ion accelerator. A high-intensity rf ion source was developed for use in conjunction with electrostatic acceleration and magnetic mass separation of ion beams in the 0 to 8 kev energy range. Beams of N(+) or N2(+) ions have been produced with intensities of 200 to 500 micro-a (approx. 1 sq cm in cross section) and energy half-widths of about 20 ev. The sputtering yields of five metals (Cu, Ni, Fe, Mo, and W) were obtained as a function of energy (0-8 kev), bombarding ion (N(+) and N2(+)), and angle of incidence (normal and 450). Results are presented and some of their theoretical implications are discussed.

Bader, Michel↗

Ion conductive inks and solutions for additive manufacturing of lithium microbatteries

A separator made of ion conductive ink is produced by additive manufacturing. A micro-battery is produced with the separator made of ion conductive ink located between the battery's anode and cathode. The separator functions to keep the anode and cathode apart and to facilitate the transport of ions to produce an operative micro-battery.

25 ENERGY STORAGE↗

Magnetospheric origin of energetic (at least 50 keV) ions upstream of the bow shock - The October 31, 1977, event

Energetic particle data gathered by the ISEE-1 and IMP-7 and -8 spacecraft on Oct. 31, 1977 while travelling inside the plasma sheet upstream of the earth's bow shock are analyzed for an indication of the source of the 30 keV-1 MeV particles observed. The IMP spacecraft also travelled through the magnetosphere and the dawn bow shock during the measurement data. The data included records of magnetospheric bursts of energetic protons, which had intensities about 2-8 times higher inside the plasma sheet than did the proton intensities. The magnetospheric bursts began about 40 min before the ISEE recorded an upstream ion event and 2 hr before its cutoff. Other data indicated that the appearance of upstream ions was controlled by the interplanetary magnetic field. The ions arose in the plasma sheet of the magnetosphere and in 'leaking' upstream experienced a separation of ions from electrons, a condition caused by the interplanetary magnetic field. A phenomenological model is developed for the process of injection of energetic particles upstream of the bow shock in a manner that is not commensurate with Fermi acceleration.

Anagnostopoulos, G. C.↗

Metadynamics investigation of lanthanide solvation free energy landscapes and insights into separations energetics

Lanthanide ion solvation chemistry in nonaqueous phases is key to understanding and developing effective separation processes for these critical materials. Due to the complexity and inherent disorder of the solution phase, a comprehensive picture of the solvated metal ion is often difficult to generate solely from conventional spectroscopic approaches and electronic structure calculations, particularly in the extractant phase. In this work, we use classical molecular dynamics (MD) simulation with an advanced sampling technique, metadynamics, supplemented by experimental spectroscopy and speciation analysis, to measure lanthanide solvation free energy landscapes. We define coordination-based collective variables to probe the entire range of solvation configurations in the organic phase of lanthanum (La), europium (Eu), and lutetium (Lu) nitrate salts bound with a commonly used extractant, N,N′-dimethyl, N,N′-dioctylhexylethoxymalonamide (DMDOHEMA). The known lanthanide extraction trend of La ≈ Eu > Lu is readily explained by the measured free energy surfaces, which show consistent DMDOHEMA coordination from La to Eu, followed by loss of DMDOHEMA coordination from Eu to Lu. These simulations suggest how ligand crowding at the metal center can control selectivity, in this case resulting in the opposite extraction trend as observed with other conventional extractants, where the enthalpic contribution from increasing lanthanide charge density across the series dominates the extraction energetics. We also find that the presence of inner-sphere water, verified by time-resolved fluorescence, diversifies the accessible solvation structures. As a result, understanding solvation requires consideration of an entire thermodynamic ensemble, rather than the single dominant lowest-energy structure, as is often considered out of necessity in interpretation of spectroscopic data or in electronic structure-based ligand design approaches. In general, we demonstrate how metadynamics uniquely enables investigation of complex, multidimensional solvation energetic landscapes, and how it can explain selectivity trends where extraction is controlled by more complex mechanisms than simple charge density-based selectivity.

Wang, Xiaoyu↗

Thermodynamic Modeling of Aqueous LiCl, LiBr, LiI, and LiNO 3 Solutions

Thermodynamic models are essential to facilitate the advancement of process design, optimization, and operation of electrolyte systems. In this work, a comprehensive thermodynamic framework based on the Electrolyte Nonrandom Two-Liquid model is developed to calculate phase equilibria behavior and salt solubility of aqueous LiCl, LiBr, LiI, and LiNO 3 solutions. The model describes the non-ideality of the electrolyte solutions by using two binary interaction parameters for each electrolyte-molecule pair in the system. Each binary interaction parameter is further expressed with up to three temperature coefficients which are regressed from experimental data. To take into account the hydration of lithium ion, two separate chemistries for the dissociation of lithium salts are investigated. In the first case, the lithium ion is considered as a bare ion, Li + , while in the second case hydration of the lithium ion from Li + to Li(H 2 O) + is considered. Here, the calculated thermodynamic properties compare adequately with the experimental data for both sets of chemistries for concentrations up to saturation and temperatures from 273.15 K up to 623.15 K. Moderate to significant improvements are observed with the incorporation of the hydration chemistry for aqueous LiCl, LiBr, and LiI solutions when compared to the non-hydrated lithium ion model results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Critical Role of Anion–Solvent Interactions for Dynamics of Solvent-in-Salt Solutions

Most polar solvent molecules are unstable toward electrode materials used in Li-based batteries. Solid electrolytes and ionic liquids are far more stable; however, they have relatively low conductivity, and therefore electrical energy storage devices based on them would suffer from low power. Solvent-in-salt (SIS) systems combine chemical stability with relatively high conductivity. Here, we show how the nature of the employed anion affects the structure and dynamics of SIS systems. The transport of ions in lithium bis(fluorosulfonyl)imide (Li-FSI) systems was determined to be always faster than that in lithium bis(trifluoromethanesulfonyl)imide (Li-TFSI) systems. Moreover, we found that viscosity does not solely control conductivity and that the lower conductivity of TFSI – solutions is related to their stronger interaction with the solvent. This restricts solvent dynamics and slows down ion motions compared to that of FSI – . Interestingly, the TFSI–solvent interaction also leads to better charge separation (weaker ion–ion correlations) and a higher transference number for Li. Finally, our results suggest that the ability to tune the solvent network formed around the anions may further improve electrolyte conductivity and Li transference number for safer and more efficient energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ionic liquid-enhanced recycling of lithium-ion battery black mass via heavy liquid centrifugal separation

Direct recycling of lithium-ion batteries (LIBs) is of great significance to supply chain security and environmental protection by restoring spent battery materials to their original purpose without destroying their chemical structure. One of the key processes for direct recycling is to separate valuable anode and cathode active materials from black mass. This study evaluates ionic liquid-enhanced Heavy Liquid Centrifugal Separation (HLCS) as an efficient method for separating LIB black mass into its constituent anode and cathode materials. The optimized HLCS process achieved a separation efficiency of over 95%, yielding a graphite-rich upper layer and an NMC-rich lower layer. Characterization by thermogravimetric analysis (TGA), X-ray diffraction (XRD), and inductively coupled plasma-optical emission spectroscopy (ICP-OES) confirmed the purity and structural integrity of the recovered fractions. The addition of N-methyl-2-pyrrolidone and ionic liquid 1-ethyl-3-methylimidazolium bromide decoupled entangled particles, while subsequent treatment of the anode layer with 1-(2,3-dihydroxypropyl)-3-methylimidazolium chloride further enhanced separation purity. The recycled graphite exhibited comparable battery performance to pristine graphite. These results demonstrate HLCS as a promising LIB recycling strategy, advancing sustainable battery manufacturing.

Adigun, Babafemi [Univ. of Tennessee, Knoxville, T↗

The Measurement of Sulfur Oxidation Products and Their Role in Homogeneous Nucleation

An improved version of a transverse ion source was developed which uses selected ion chemical ionization mass spectrometry techniques inside of a particle nucleation flow tube. These new techniques are very unique, in that the chemical ionization is done inside of the flow tube rather than by having to remove the compounds and clusters of interest which are lost on first contact,with any surfaces. The transverse source is also unique because it allows the ion reaction time to be varied over more than an order of magnitude, which in turn makes possible the separation of ion induced cluster growth from the charging of preexisting molecular clusters. As a result of combining these unique capabilities, the first ever measurements of prenucleation molecular clusters were performed. These clusters are the intermediate stage of growth in the gas-to-particle conversion process. This new technique provides a means of observing clusters containing 2, 3, 4, ... and up to about 8 sulfuric acid molecules, where the critical cluster size under these measurement conditions was about 4 or 5. Thus, the nucleation process can now be directly observed and even growth beyond the critical cluster size can be investigated. The details of this investigation are discussed in a recently submitted paper, which is included as Appendix A. Measurements of the diffusion coefficient of sulfuric acid and sulfuric acid clustered with a water molecule have also been performed. The measurements are also discussed in more detail in another recently submitted paper which is included as Appendix B. The empirical results discussed in both of these papers provide a critical test of present nucleation theories. They also provide new hope for resolving many of the huge discrepancies between field observation and model prediction of particle nucleation. The second part of the research conducted under this project was directed towards the development of new chemical ionization techniques for measuring sulfur oxidation products.

Eisele, F. L.↗

On the Presence and Thermalization of Cold Ions in the Exhaust of Antiparallel Symmetric Reconnection

Using fully kinetic 2.5 dimensional particle-in-cell simulations of anti-parallel symmetric magnetic reconnection, we investigate how initially cold ions are captured by the reconnection process, and how they evolve and behave in the exhaust. We find that initially cold ions can remain cold deep inside the exhaust. Cold ions that enter the exhaust downstream of active separatrices, closer to the dipolarization front, appear as cold counter-streaming beams behind the front. In the off-equatorial region, these cold ions generate ion-acoustic waves that aid in the thermalization both of the incoming and outgoing populations. Closest to the front, due to the stronger magnetization, the ions can remain relatively cold during the neutral plane crossing. In the intermediate exhaust, the weaker magnetization leads to enhanced pitch angle scattering and reflection. Cold ions that enter the exhaust closer to the X line, at active separatrices, evolve into a thermalized exhaust. Here, the cold populations are heated through a combination of thermalization at the separatrices and pitch angle scattering in the curved magnetic field around the neutral plane. Depending on where the ions enter the exhaust, and how long time they have spent there, they are accelerated to different energies. The superposition of separately thermalized ion populations that have been accelerated to different energies form the hot exhaust population.

Cecilia Norgren↗

Emissivity measurements of CuCrZr alloy

The Facility for Rare Isotope Beams (FRIB) heavy-ion accelerator, in user operation since 2022, produces rare isotope beams via interactions of high-intensity stable ion beams with a graphite production target. Approximately 20–40% of the primary beam power is deposited in the target, while the remaining 60–80% is absorbed by the beam dump. The minichannel beam dump (MCBD), currently operated at 20 kW and designed for operation up to 50 kW, uses CuCrZr alloy absorber plates. Thermal validation and thermal cycling tests of the MCBD were conducted at the Applied Research Laboratory (ARL) at Pennsylvania State University. Temperature measurements were obtained from an infrared (IR) camera. Since accurate temperature determination requires reliable emissivity values, the emissivity of CuCrZr was measured using the IR camera validated against thermocouple reference temperatures up to approximately 650 °C. The measurements were conducted under a vacuum level of approximately 10 -5 torr to minimize emissivity variations due to surface oxidation. The emissivity of CuCrZr was determined to be 0.057 ± 0.009 using a constant fit to the measured data over the surface temperature range from 100–650 °C.

Accelerator Subsystems and Technologies↗

Microfluidic ion mobility chromatograph

This paper describes the development of a microfluidic ion mobility chromatograph for small inorganic ion analysis.

microfluids separation ion chromatography↗