Search NASA⌕ Search

SEARCH · Search NASA

Results for “islanding operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Does practice make perfect? Lessons learned from full-scale power system incident response exercise

While threats to the energy sector occur daily, few utilities get the opportunity to fully test out their detection and response mechanisms to advanced threats in the real world. With the high demand for reliability, few grid operators would allow execution of simulated cyber-attacks on their live systems. The DOE-funded Liberty Eclipse project offers a unique opportunity for small and large utilities and coops to practice their combined IT/OT responses to a live red team executing attacks against an isolated power system on an island in New York. Both cyber teams and power operations teams must work together to detect and respond to attacks, even restoring the power system against extreme impacts. Lessons learned from these exercises reveal key takeaways for understanding what a real attack against the electric sector will look like, gaps in execution of the best-laid plans when the pressure of a real event is bearing down, and how organizations can better prepare for advanced attacks by optimizing participation in exercises. This presentation will discuss successes and opportunities for improvement both in how utilities can prepare for and respond to events, as well as how full-scale IT/OT exercises can be coordinated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of microgrid resilience through co-simulation of power system dynamics and communication systems

The interdependence of power and communication systems in smart grid technologies is acknowledged, but difficult to quantify. Communication systems can be essential to maintaining stability in microgrids that are islanded due to extreme events. Though many power system studies assume the presence of communication networks, detailed modeling of power and communication systems for dynamic studies of microgrids is rare. The work presented in this paper develops a framework for power and communication system co-simulation to study the impact of communications system on microgrid stability. An operational use case is examined where a battery energy storage system operates to offset the loss of generation in an islanded microgrid. The framework is evaluated for different communication technologies, network structures, and communication media.

Thekkumparambath Mana, Priya↗

The “Brookhaven Brassie” and the Response to the Three Mile Island Accident

In the mid-1970s, American civil defense authorities became increasingly concerned with the potential threat of fission reactor accidents. Research from the Defense Civil Preparedness Agency began to be aimed not just at the ever-present threat of nuclear warfare, but also peacetime emergencies as part of a "dual use" philosophy. The Brookhaven National Laboratory received funding to create a prototype radioiodine air sampling system, with multiple publications detailing the creation of the air sampler itself and a special CD V-700 survey meter that accompanied it. In late March 1979, the system found its first operational employment at the reactor accident at Three Mile Island, Pennsylvania. Despite successful use and further study, the BNL Air Sampler was not widely fielded by the federal government. However, lessons learned from its employment and development may be applicable to contemporary radiological emergency response.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A fully implicit, asymptotic-preserving, semi-Lagrangian algorithm for the time dependent anisotropic heat transport equation

In this paper, we extend the operator-split asymptotic-preserving, semi-Lagrangian algorithm for time dependent anisotropic heat transport equation proposed in Chacón et al. (2014) [18] to use a fully implicit time integration with backward differentiation formulas. The proposed implicit method can deal with arbitrary heat-transport anisotropy ratios $\mathcal{X}$∥ /$ \mathcal{X}$⟂ $\ggg$ 1 (with $\mathcal{X}$∥, $ \mathcal{X}$⟂ the parallel and perpendicular heat diffusivities, respectively) in complicated magnetic field topologies in an accurate and efficient manner. Further, the implicit algorithm is second-order accurate temporally and demonstrates an accurate treatment at boundary layers (e.g., island separatrices), which was not ensured by the operator-split implementation. The condition number of the resulting algebraic system is independent of the anisotropy ratio, and is inverted with preconditioned GMRES. We propose a simple preconditioner that renders the finite-dimensional linear operator compact, resulting in mesh-independent convergence rates for topologically simple magnetic fields, and convergence rates scaling as ~ (NΔt) 1/4 (with N the total mesh size and Δt the timestep) in topologically complex magnetic-field configurations. We demonstrate the accuracy and performance of the approach with test problems of varying complexity, including an analytically tractable boundary-layer problem in a straight magnetic field, and a topologically complex magnetic field featuring magnetic islands with extreme anisotropy ratios $\mathcal{X}$∥ /$ \mathcal{X}$⟂ = 10 10 ) .

97 MATHEMATICS AND COMPUTING↗

Implementing Admittance Relaying for Microgrid Protection

An earlier study evaluated issues with microgrid protection. This highlighted the difficulties with microgrid protection, which include: 1. lack of fault current from inverter-interfaced generation, 2. varying fault current between grid-connected and islanded modes, 3. potential for normally-meshed operation and 4. unbalanced operation due to single-phase loads. It is worth noting that not all microgrid designs will include all these challenges. For example, microgrids could choose to omit meshed operation. Previous work identified differential protection based on the discrete S-transform for line protection and admittance protection for load protection as possible solutions . However, some severe limitations were identified. This included the potential for blinding of the discrete S-transform protection when fault contribution on either end of the line is similar, and loss of protection selectivity for admittance protection in the case of upstream line-ground faults. This report investigates admittance protection as a solution for line and load protection in greater detail by comparing analytical and simulated results. Section 2 describes the protection schemes analyzed and the behavior of inverter-interfaced microgrids under faults in more detail. Section 3 derives sequence networks for the fault cases considered. Section 4 presents a transient model constructed to validate the impedances calculated from the sequence networks. Section 5 compares the results from the sequence networks and transient model. Last, Section 6 presents the conclusions of this study in terms of the suitability of admittance relaying for protection of inverter-interfaced microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic State Estimation for Radial Microgrid Protection

Dynamic state estimation (DSE) is a generalization of differential protection that offers a reduced likelihood of misoperation, particularly in the case of devices with nonlinear characteristics such as transformers which are being energized. It is also useful in cases where distance protection performs poorly, such as transmission lines with series compensation or mutually coupled transmission lines. DSE has been previously applied to microgrid branch protection. This study investigates the use of DSE for protection of radial portions of a microgrid or distribution system. This can be a challenge in microgrids or distribution systems with distributed generation on account of lack of fault current from inverter-interfaced generation, varying fault current between grid- connected and islanded modes, the potential for normally-meshed operation and unbalanced operation due to single-phase loads. Admittance relaying has been investigated as a solution for protection of microgrids, though it has been observed to have issues with grounded-wye connected loads, and additional relaying is necessary to prevent misoperation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BLOC Site - ASSIST / Raw Data

This dataset contains raw data (summary, chA, chB) from the ASSIST operated by NOAA Physical Science Laboratory on Block Island for WFIP3.

17 WIND ENERGY↗

NANT Site - ASSIST / Raw Data

This dataset contains raw data (summary, chA, chB) from the ASSIST operated by NOAA Physical Science Laboratory on Nantucket Island for WFIP3.

17 WIND ENERGY↗

NANT Site - ASSIST / Processed Data

This dataset contains processed summary data from the ASSIST operated by NOAA Physical Science Laboratory on Nantucket Island for WFIP3.

17 WIND ENERGY↗

Block Island Noise Monitoring Data

Underwater sound levels near Block Island were monitored during wind turbine construction and operational phases to detect acoustic signals and sediment-borne vibrations, providing real-time data to improve model predictions for future offshore wind facilities.

17 WIND ENERGY↗

Attenuation of propagation through rain for an earth-satellite path correlated with predicted values using radar

During the summer of 1974 and spring of 1975, measurements of attenuation of propagation through rain were made at Wallops Island, VA, using 13 and 18 GHz transmitters operating in the uplink mode toward the ATS-6 satellite. Simultaneously, rain reflectivity levels were measured along the earth-satellite path using a high resolution (0.4 deg beamwidth) S-band radar having a scanning antenna. Four rain-gages and two disdrometers were also located in the vicinity of the transmitters. The radar and disdrometer data were used in a modelling program to predict attenuation levels which were subsequently compared to the directly measured fades over nearly simultaneous time intervals. Predicted attenuation levels were obtained for three drop size distributions. Comparisons between predicted and measured attenuation levels showed the APL dropsize distribution gave the smallest rms difference of 1.3 dB at 13 and 18 GHz although the rms difference corresponding to Marshall-Palmer was close to this value. The good agreement suggests the validity of using radar to model path attenuation to obtain attenuation statistics.

Goldhirsh, J.↗

Lightning electric field measurements which correlate with strikes to the NASA F-106B aircraft, 22 July 1980

Ground-based data collected on lightning monitoring equipment operated by Goddard Space Flight Center at Wallops Island, Virginia, during a storm being monitored by NASA's F-106B, are presented. The slow electric field change data and RF radiation data were collected at the times the lightning monitoring equipment on the aircraft was triggered. The timing of the ground-based events correlate well with events recorded on the aircraft and provide an indication of the type of flash with which the aircraft was involved.

Levine, D. M.↗

Airborne lidar detection of subsurface oceanic scattering layers

The airborne lidar detection and cross-sectional mapping of submerged oceanic scattering layers are reported. The field experiment was conducted in the Atlantic Ocean southeast of Assateague Island, VA. NASA's Airborne Oceanographic Lidar was operated in the bathymetric mode to acquire on-wavelength 532-nm depth-resolved backscatter signals from shelf/slope waters. Unwanted laser pulse reflection from the air-water interface was minimized by spatial filtering and off-nadir operation. The presence of thermal stratification over the shelf was verified by the deployment of airborne expendable bathythermographs. Optical beam transmission measurements acquired from a surface truthing vessel indicated the presence of a layer of turbid water near the sea floor over the inner portion of the shelf.

Hoge, Frank E.↗

An Experimental Study of Small-Scale Variability of Raindrop Size Distribution

An experimental study of small-scale variability of raindrop size distributions (DSDs) has been carried out at Wallops Island, Virginia. Three Joss-Waldvogel disdrometers were operated at a distance of 0.65, 1.05, and 1.70 km in a nearly straight line. The main purpose of the study was to examine the variability of DSDs and its integral parameters of liquid water content, rainfall, and reflectivity within a 2-km array: a typical size of Cartesian radar pixel. The composite DSD of rain events showed very good agreement among the disdrometers except where there were noticeable differences in midsize and large drops in a few events. For consideration of partial beam filling where the radar pixel was not completely covered by rain, a single disdrometer reported just over 10% more rainy minutes than the rainy minutes when all three disdrometers reported rainfall. Similarly two out of three disdrometers reported5%more rainy minutes than when all three were reporting rainfall. These percentages were based on a 1-min average, and were less for longer averaging periods. Considering only the minutes when all three disdrometers were reporting rainfall, just over one quarter of the observations showed an increase in the difference in rainfall with distance. This finding was based on a 15-min average and was even less for shorter averaging periods. The probability and cumulative distributions of a gamma-fitted DSD and integral rain parameters between the three disdrometers had a very good agreement and no major variability. This was mainly due to the high percentage of light stratiform rain and to the number of storms that traveled along the track of the disdrometers. At a fixed time step, however, both DSDs and integral rain parameters showed substantial variability. The standard deviation (SD) of rain rate was near 3 mm/h, while the SD of reflectivity exceeded 3 dBZ at the longest separation distance. These standard deviations were at 6-min average and were higher at shorter averaging periods. The correlations decreased with increasing separation distance. For rain rate, the correlations were higher than previous gauge-based studies. This was attributed to the differences in data processing and the difference in rainfall characteristics in different climate regions. It was also considered that the gauge sampling errors could be a factor. In this regard, gauge measurements were simulated employing existing disdrometer dataset. While a difference was noticed in cumulative distribution of rain occurrence between the simulated gauge and disdrometer observations, the correlations in simulated gauge measurements did not differ from the disdrometer measurements.

Tokay, Ali↗