Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The effect of nonablative laser energy on joint capsular properties. An in vitro histologic and biochemical study using a rabbit model

The purpose of this study was to evaluate the effect of laser energy at nonablative levels on joint capsular histologic and biochemical properties in an in vitro rabbit model. The medial and lateral portions of the femoropatellar joint capsule from both stifles of 12 mature New Zealand White rabbits were used. Specimens were divided into three treatment groups (5 watts, 10 watts, and 15 watt) and one control group using a randomized block design. Specimens were placed in a 37 degrees bath of lactated Ringer's solution and laser energy was applied using a holmium:yttrium-aluminum-garnet laser in four transverse passes across the tissue at a velocity of 2 mm/sec with the handpiece set 1.5 mm from the synovial surface. Histologic analysis revealed thermal alteration of collagen (fusion) and fibroblasts (pyknosis) at all energy densities, with higher laser energy causing significantly greater morphologic changes over a larger area (P < 0.05). Application of laser energy did not significantly alter the biochemical parameters evaluated, including type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I collagen content and nonreducible crosslinks (P > 0.05). This study demonstrated that nonablative laser energy caused significant thermal damage to the joint capsular tissue in an energy-dependent fashion, but type I Collagen content and nonreducible corsslinks were not significantly altered.

NASA Discipline Musculoskeletal↗

Pseudo-Random Modulation of a Laser Diode for Generating Ultrasonic Longitudinal Waves

Laser generated ultrasound systems have historically been more complicated and expensive than conventional piezoelectric based systems, and this fact has relegated the acceptance of laser based systems to niche applications for which piezoelectric based systems are less suitable. Lowering system costs, while improving throughput, increasing ultrasound signal levels, and improving signal-to-noise are goals which will help increase the general acceptance of laser based ultrasound. One current limitation with conventional laser generated ultrasound is a material s damage threshold limit. Increasing the optical power to generate more signal eventually damages the material being tested due to rapid, high heating. Generation limitations for laser based ultrasound suggests the use of pulse modulation techniques as an alternate generation method. Pulse modulation techniques can spread the laser energy over time or space, thus reducing laser power densities and minimizing damage. Previous experiments by various organizations using spatial or temporal pulse modulation have been shown to generate detectable surface, plate, and bulk ultrasonic waves with narrow frequency bandwidths . Using narrow frequency bandwidths improved signal detectability, but required the use of expensive and powerful lasers and opto-electronic systems. The use of a laser diode to generate ultrasound is attractive because of its low cost, small size, light weight, simple optics and modulation capability. The use of pulse compression techniques should allow certain types of laser diodes to produce usable ultrasonic signals. The method also does not need to be limited to narrow frequency bandwidths. The method demonstrated here uses a low power laser diode (approximately 150 mW) that is modulated by controlling the diode s drive current and the resulting signal is recovered by cross correlation. A potential application for this system which is briefly demonstrated is in detecting signals in thick composite materials where attenuation is high and signal amplitude and bandwidth are at a premium.

Madaras, Eric I.↗

Corrosion Behavior of Laser-Interference Structured AA2024 Coated with a Chromate-Containing Epoxy Primer

In this study, the corrosion behavior of laser-interference treated AA2024-T3 specimens, which are coated with a primer, is presented. The surface of as-received AA2024-T3 specimens were laser-interference structured by splitting the primary beam of a Q-switched Nd:YAG pulsed nanosecond laser into two beams and focusing them to the same spot on the specimen surface. After being stored in plastic cases for up to 70 d, without any additional cleaning, the specimens were spray painted with a chromate-containing epoxy primer, CA7233, compliant to MIL-PRF-23377 Type I Class C2 specification. The corrosion behavior of laser-interference specimens was assessed against that of specimens prepared by chromated conversion coating and sulfuric acid anodizing treatments. After the ASTM B117 corrosion exposure, it was found that the laser processed specimens exhibited only few blisters. On one hand, most specimens prepared at a laser fluence of 1.78 J/cm 2 , without any additional chemical cleaning, were found to develop one very small blister after only 96 h of exposure. However, the growth of these blisters was not significant even after 1,000 h of salt spray exposure. On the other hand, only a fraction of the specimens prepared at a laser fluence of 1.24 J/cm 2 and acetone wiped right after the laser structuring were found to develop several tiny blisters after 790 h and longer exposure. Overall, it was found that the corrosion damage was minimized at a laser rastering speed of 4 mm/s, a condition for which only 33% of specimens developed very minor corrosion damage. Furthermore, the ASTM D1654 creepage ratings, which was used to evaluate the corrosion damage along the scribe lines, were found to be at least nine for all coated panels. These results indicate that the laser-interference technique with the additional acetone wiping has the potential to be further developed as a nonchemical surface preparation technique for chromate-containing epoxy primers coating systems.

36 MATERIALS SCIENCE↗

Laser Safety Device

A major focus of work done at Air Products and Chemicals' Laser Application Laboratory is on use of ultraviolet radiation using high energy excimer lasers. Because light within the wavelength of excimer lasers is invisible, it can cause serious damage to eyes and tissue. To contain the laser beam, Air Products Incorporated a Jet Propulsion Laboratory invention described in a technical support package into its beam stops. The technology interrupts the laser pathway and allows workers to remain in the target area without shutting off the laser.

Source record↗

Optimizing fused silica debris shield use in the National Ignition Facility

The National Ignition Facility (NIF) deliberately and routinely operates with its final optics exposed to fluences likely to induce and grow damage. This choice has enabled the NIF to operate at energies previously unachievable at the expense of limitations to delivered power and energy contingent on the ability to repair damage on the final optics. Prior to the introduction of the fused silica debris shield (FSDS), the grating debris shield (GDS) was the optic type on the NIF most prone to damage and hence a primary limiter to the delivered energy. The introduction of the FSDS has reduced the damage initiation rate on the GDS by about two orders of magnitude to date. Despite the FSDS being a disposable optic, it is important to understand how the FSDS damages and when its damage requires it to be exchanged to maximize the FSDS lifetime while still protecting the GDS from damage. We will define the FSDS exchange criteria and evaluate the damage initiation mechanisms of the FSDS. The surface damage morphologies provide insight into the impact of the various damage mechanisms that limit the FSDS lifetime. These results are utilized in our analysis to optimize the FSDS exchange criteria to further extend the GDS lifetime.

42 ENGINEERING↗

Lamb Wave Assessment of Fatigue and Thermal Damage in Composites

Among the various techniques available, ultrasonic Lamb waves offer a convenient method of evaluating composite materials. Since the Lamb wave velocity depends on the elastic properties of a structure, an effective tool exists to monitor damage in composites by measuring the velocity of these waves. Lamb wave measurements can propagate over long distances and are sensitive to the desired in-plane elastic properties of the material. This paper describes two studies which monitor fatigue damage and two studies which monitor thermal damage in composites using Lamb waves. In the fatigue studies, the Lamb wave velocity is compared to modulus measurements obtained using strain gage measurements in the first experiment and the velocity is monitored along with the crack density in the second. In the thermal damage studies, one examines samples which were exposed to varying temperatures for a three minute duration and the second includes rapid thermal damage in composites by intense laser beams. In all studies, the Lamb wave velocity is demonstrated to be an excellent method to monitor damage in composites.

Seale, Michael D.↗

Laser ablation of human atherosclerotic plaque without adjacent tissue injury

Seventy samples of human cadaver atherosclerotic aorta were irradiated in vitro using a 308 nm xenon chloride excimer laser. Energy per pulse, pulse duration and frequency were varied. For comparison, 60 segments were also irradiated with an argon ion and an Nd:YAG laser operated in the continuous mode. Tissue was fixed in formalin, sectioned and examined microscopically. The Nd:YAG and argon ion-irradiated tissue exhibited a central crater with irregular edges and concentric zones of thermal and blast injury. In contrast, the excimer laser-irradiated tissue had narrow deep incisions with minimal or no thermal injury. These preliminary experiments indicate that the excimer laser vaporizes tissue in a manner different from that of the continuous wave Nd:YAG or argon ion laser. The sharp incision margins and minimal damage to adjacent normal tissue suggest that the excimer laser is more desirable for general surgical and intravascular uses than are the conventionally used medical lasers.

Grundfest, W. S.↗

Laser Based Remote and Rapid Inspection for Composite Plates

Composites have been extensively used in aero structure and become the predominate components in the new airframes. Thus, rapid and effective inspection for composite structures is highly desired in aerospace engineering in order to shorten the certificate cycle for new structures or provide safety guarantee for existing ones. In this paper, a laser based remote Lamb wave inspection system is presented and implemented on composite plates for simulated damage detection. The system employs pulsed laser (PL) and scanning laser Doppler vibrometer (SLDV) for noncontact and remote Lamb wave actuation and wavefield sensing. A composite plate with simulated defect (surface bonded quartz rod) is inspected with the PL-SLDV laser system. Wave scattering are observed in the SLDV acquired wavefield and the damage is further evaluated with wavefield imaging and frequency wavenumber analysis. Potential application towards automatic PL Lamb wave excitation is also explored through employing an industry robotic arm towards rapid inspection.

Lamb waves↗

Novel Technology of Non-Contact Real-Time Radiation Damage Sensor for High Power Targets

High-power proton beams planned for forthcoming long-baseline neutrino experiments will subject solid targets to unprecedented radiation damage, threatening reliability and increasing costs. To address this challenge, we are building a real-time, non-contact sensor that tracks damage by measuring broadband laser reflectivity changes from the target surface. A low-power super-continuum Class 3B laser illuminates the sample inside a vacuum test chamber while a high-resolution fiber-coupled spectrometer captures S- and P-polarized light; spectral shifts reveal defect-driven variations in optical constants. My internship goal is to design, build, and commission this prototype by implementing a laser-safety interlock and light shield, integrating remote-operation cameras, and fabricating modular 3-D-printed mounts that enable tool-free swaps without disturbing alignment. The laser, spectrometer, and vacuum chamber have been delivered; interlock hardware, cameras, and mounts are in final assembly, and leak testing of the chamber is underway. Upcoming work will focus on initial calibration of the sensor and executing first beam-irradiation studies.

Pumarino, Rafael↗

Laser-induced electric breakdown in solids

A review is given of recent experimental results on laser-induced electric breakdown in transparent optical solid materials. A fundamental breakdown threshold exists characteristic for each material. The threshold is determined by the same physical process as dc breakdown, namely, avalanche ionization. The dependence of the threshold on laser pulse duration and frequency is consistent with this process. The implication of this breakdown mechanism for laser bulk and surface damage to optical components is discussed. It also determines physical properties of self-focused filaments.

Bloembergen, N.↗

Selection of Optical Cavity Surface Coatings for 1micron Laser Based Missions

The particulate surface cleanliness level on several coatings for aluminum and beryllium substrates were examined for use in the optical cavities of high pulse energy Nd:YAG Q-switched, diode-pumped lasers for space flight applications. Because of the high intensity of the lasers, any contaminants in the laser beam path could damage optical coatings and limit the instrument mission objectives at the operating wavelength of 1 micron (micrometer). Our goal was to achieve an EST-STD-CC1246D Level 100 particulate distribution or better to ensure particulate redistribution during launch would not adversely affect the performance objectives. Tapelifts were performed to quantify the amount of particles using in-house developed procedures. The primary candidate coatings included chromate conversion coating aluminum (Al), uncoated Al electroless Nickel (Ni) on Al, Ni-gold (Au) on Al, anodized Al, and gold (Au)/Ni on Beryllium (Be). The results indicate that there were advantages in Ni and Au coating applications for the two major substrates, Al and Be, when considering applications that need to meet launch environments.

Hedgeland, Randy J.↗

Giant Pulse Phenomena in a High Gain Erbium Doped Fiber Amplifier

High gain Erbium Doped Fiber Amplifiers (EDFAs) are vulnerable to optical damage when unseeded, e.g. due to nonlinear effects that produce random, spontaneous Q-switched (SQS) pulses with high peak power, i.e. giant pulses. Giant pulses can damage either the components within a high gain EDFA or external components and systems coupled to the EDFA. We explore the conditions under which a reflective, polarization-maintaining (PM), core-pumped high gain EDFA generates giant pulses, provide details on the evolution of normal pulses into giant pulses, and provide results on the transient effects of giant pulses on an amplifier's fused-fiber couplers, an effect which we call Fiber Overload Induced Leakage (FOIL). While FOIL's effect on fused-fiber couplers is temporary, its damage to forward pump lasers in a high gain EDFA can be permanent.

Li, Stephen X.↗

Giant Pulse Phenomena in a High Gain Erbium Doped Fiber Amplifier

High gain Erbium Doped Fiber Amplifiers (EDFAs), while revolutionizing optical communications, remain vulnerable to optical damage when unseeded, e.g. due to nonlinear effects that produce random pulses with high peak power, i.e. giant pulses. Giant pulses can damage the components in a high gain EDFA or external components and systems coupled to the EDFA. We explore the conditions under which a reflective, polarization-maintaining (PM), core-pumped high gain EDFA generates giant pulses, provide details on conditions under which normal pulses evolve into giant pulses, and provide results on the transient effects of giant pulses on amplifier's fused-fiber couplers, an effect which we call Fiber Overload Induced Leakage (FOIL). While FOIL's effect on fused-fiber couplers is temporary, its damage to forward pump lasers in a high gain EDFA can be permanent.

Li, Stephen X.↗

Investigation of a gallium alloy liquid metal mirror for application in inertial fusion energy systems

The final optic in future inertial fusion energy plants must maintain high performance and survivability under gigashot laser irradiation while exposed to fusion byproducts. Although no practical solution has been demonstrated, a self-healing final turning mirror based on a grazing-incidence liquid metal mirror has been theoretically explored. This work investigates the suitability of a gallium alloy. The experimental system simulates key conditions, including vacuum exposure and 10-Hz, 355-nm, and 6-ns laser pulses. Experiments address reflectivity, damage, and response as a function of pressure. Results highlight the potential of liquid metal gallium alloys for robust final optics in laser-based fusion power plants and inform non-traditional optics for intense laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense cyclic heating effects on thermo-fracture and thermal shock of solid tungsten and open-cell tungsten foam

Here we investigate here the effects of transient (cyclic) arc-jet plasma and laser heating on fracture behavior of W-foam and solid tungsten. The two key parameters that control the foam thermomechanical response are its density and mean cell size expressed in Pores Per Inch (PPI). Tungsten foam samples were fabricated with Chemical Vapor Deposition (CVD) with variety of PPI and relative density. These were tested under two types of qualitatively different conditions: (1) high-enthalpy arc-jet, and (2) high-power cyclic laser heating. None of the foam samples showed macroscopic through-thickness cracks. However, distributed micro-cracks were observed on ligaments and their triple junctions. Under the same loading conditions, W-foam and solid tungsten showed similar crack network pattern and characteristic length-scale. However, Crack Opening Displacement (COD) was twice as large in solid W as compared to W-foam. Foam samples that have been previously exposed to a low-pressure helium plasma showed significant changes in their surface forming nano-texture fuzz which was removed by subsequent testing in the arc-jet. Extensive fracture and re-crystallization were observed in the thin solid W disk that was fully-constrained from expansion. Thicker and fully-constrained solid W disks did not display recrystallization, grain growth, and extensive cracking. However, thicker disks that were free to expand showed some recrystallization and extensive through-thickness cracks due to less effective cooling and thus higher temperatures. Laser beam testing showed no visible damage formation at 0.19 GW/m 2 and 0.38 GW/m 2 for both low-density (23%) and high-density (43%) foams at low pulses (100-1000). Micro-cracks were observed after 10,000 pulses at 0.19 GW/m 2 in both foams, and in low-density foam after 100,000 at 0.38 GW/m 2 . The nature of thermomechanical damage in W-foam exposed to extreme power (GW/m 2 ) short-duration laser pulses was found to be qualitatively similar to that of high power (MW/m 2 ) long-duration arc-jet.

36 MATERIALS SCIENCE↗