Search NASA⌕ Search

SEARCH · Search NASA

Results for “legged”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Autonomous planetary rover at Carnegie Mellon

This report describes progress in research on an autonomous robot for planetary exploration. In 1989, the year covered by this report, a six-legged walking robot, the Ambler, was configured, designed, and constructed. This configuration was used to overcome shortcomings exhibited by existing wheeled and walking robot mechanisms. The fundamental advantage of the Ambler is that the actuators for body support are independent of those for propulsion; a subset of the planar joints propel the body, and the vertical actuators support and level the body over terrain. Models of the Ambler's dynamics were developed and the leveling control was studied. An integrated system capable of walking with a single leg over rugged terrain was implemented and tested. A prototype of an Ambler leg is suspended below a carriage that slides along rails. To walk, the system uses a laser scanner to find a clear, flat foothold, positions the leg above the foothold, contacts the terrain with the foot, and applies force enough to advance the carriage along the rails. Walking both forward and backward, the system has traversed hundreds of meters of rugged terrain including obstacles too tall to step over, trenches too deep to step in, closely spaced rocks, and sand hills. In addition, preliminary experiments were conducted with concurrent planning and execution, and a leg recovery planner that generates time and power efficient 3D trajectories using 2D search was developed. A Hero robot was used to demonstrate mobile manipulation. Indoor tasks include collecting cups from the lab floor, retrieving printer output, and recharging when its battery gets low. The robot monitors its environment, and handles exceptional conditions in a robust fashion, using vision to track the appearance and disappearance of cups, onboard sonars to detect imminent collisions, and monitors to detect the battery level.

Whittaker, William↗

Integrating human factors knowledge into certification: The point of view of the Internatioanal Civil Aviation Organization (ICAO)

It is appropriate here to repeat the analogy described in the introduction to this paper which is that: The consideration of human factors requirements during the design stage of advanced, new technology systems may be seen as resting over a three-legged stool. The first leg, the equipment that a system will utilize to achieve its goals, has traditionally attracted ergonomic considerations associated with equipment design, usually centered around 'knobs and dials.' Lately, this view has expanded to include the so-called other important aspect of Human Factor's study which deals with the cognitive, behaviorial and social processes of the human operators. Study in this area must be furthered. The second leg of the stool, the procedures to operate the equipment, however, has been largely unaddressed. Procedures are not inherent to equipment, but must be developed. The importance of proper human factors consideration in the design of procedures can not be overstated. Lastly, the third leg of the stool, the certification of personnel who will operate the equipment, is very much underway, but far from being complete. The real quest now, however, is to integrate these three legs into an indivisible one. Finally, and most importantly, this workshop and its topic are extremely timely in that we are at the dawn of the most ambitious development ever undertaken in international civil aviation. This would allow us the rather unique opportunity to put theory into practice in the near future by ensuring that the concepts developed and furthered by this workshop and the follow-up are implemented in the design and certification of the ICAO future CNS/ATM systems described earlier in this paper. Now is the time to incorporate human factors requirements during the certification processes of these systems. This might act as a test to the feasibility of these ideas. Such endeavors represent a challenge for the research, engineering, training, operational and regulatory communities. But there is certainly more to be gained by attempting to meet the challenge rather than refraining from progress by decrying the difficulties involved.

Maurino, Daniel↗

Experimental Confirmation of Powerstick Concept

The results relating to the development and testing of the miniature Radioisotope Thermoelectric Generator (RTG)-like Powerstick (PS) device are presented. They confirm the earlier ideas and predictions regarding possible manufacturing of PS-devices. PS is based on a 238-Pu standard Radioactive Heating Unit (RHU) with thermal power 1.1 W developed and manufactured by DOE and successfully being used on spacecraft (Galileo, Cassini, e. g.). In the course of development, several design approaches were explored and achieving high PS efficiencies was considered. Better thermal insulation material (with thermal conductivity 0.02 W/mK) has been developed and used and different designs of PS were evaluated. Two types of PS were manufactured: PS-1, on the basis of one RHU and one thermoelectric battery/converter (TEB), and PS-2, on the basis of two RHU and one TEB. Two different sizes of TEB were used: first - with the legs of cross-section 0.45x0.45 sq-mm and height 35 mm, and second - with the legs of cross-section 0.6Ox0.60 sq-m and height 35 mm. In both cases, the number of legs was 400. The electrical power of the PS-1 was observed to deliver 22 mW at 2.5 V and for PS-2 - 53 mW at 4.1 V. The analysis of results showed that optimized version of PS-2 should be capable of more than 70 mW at 5 V, on the basis of TEB with legs of cross-section 0.67x0.67 sq-mm and height 40 mm with number of legs 324.

Pustovalov, A.↗

Effect of Serum from Chickens Treated with Clenbuterol on Myosin Accumulation, Beta-Adrenergic Receptor Population, and Cyclic AM Synthesis in Embryonic Chicken Skeletal Muscle Cell Cultures

Broiler chickens at 35 days of age were fed 1 ppm clenbuterol for 14 days. This level of dietary clenbuterol led to 5-7% increases in weights of leg and breast muscle tissue. At the end of the 14-day period, serum was prepared from both control and clenbuterol-treated chickens and was then employed as a component of cell culture media at a final concentration of 20% (v/v). Muscle cell cultures were prepared from both the leg and breast muscle groups of twelve-day chick embryos. Treatment groups included control chicken serum to which 10 nM, 50 nM, and 1 micron clenbuterol had been added, as well as cells grown in media containing 10% horse serum. Cultures were subjected to each treatment for 3 days beginning on the seventh day in culture. Neither the percent fusion nor the number of nuclei in myotubes were significantly affected by any of the treatments. The quantity of MHC was not increased by serum from clenbuterol-treated chickens in either breast and leg muscle cultures; however, MHC quantity was 50- 100% higher in cultures grown in control chicken serum to which 10 nM and 50 nM clenbuterol had also been added. The Beta-AR population was 4,000-7,000 Beta-AR per cell in cultures grown in chicken serum, with leg muscle cultures having approximately 25-30% more receptors than breast muscle cultures. Receptor population was not significantly affected by the presence of clenbuterol or by the presence of serum from clenbuterol-treated chickens. In contrast, the Beta-AR population in leg and breast muscle cultures grown in the presence of 10% horse serum was 18,000-20,000 Beta-AR per cell. Basal concentration of cAMP was not significantly affected by any of the treatments. When cultures grown in chicken serum were stimulated for 10 min with 1 micron isoproterenol, limited increases of 12-20% in cAMP concentration above basal levels were observed. However, when cultures grown in the presence of horse serum were stimulated with 1 micron isoproterenol, increases of 600-800 % in cAMP concentration above basal levels were observed. Thus, not only did cells grown in horse serum have a higher Beta-AR population, each receptor had a higher capacity for cAMP synthesis following isoproterenol stimulation. Finally, the hypothesis was tested that clenbuterol exerts its action on muscle protein content by changes in cAMP concentration. No correlation was apparent between basal cAMP concentration and MHC content.

Young, R. B.↗

Effect of Serum from Chickens Treated with Clenbuterol on Myosin Accumulation, Beta-Adrenergic Receptor Population, and Cyclic AMP Synthesis in Embryonic Chicken Skeletal Muscle Cell Cultures

Broiler chickens at 35 d of age were fed 1 ppm clenbuterol for 14 d. This level of dietary clenbuterol led to 5-7% increases in the weights of leg and breast muscle tissue. At the end of the 14-d period, serum was prepared from both control and clenbuterol-treated chickens, and was then employed as a component of cell culture media at a final concentration of 20% (v/v). Muscle cell cultures were prepared from both the leg and the breast muscle groups of 12-d chick embryos. Treatment groups included control chicken serum to which 10 nM, 50 nM, and 1 uM clenbuterol had been added, as well as cells grown in media containing 10% horse serum. Cultures were subjected to each treatment for 3 d, beginning on the seventh d in culture. Neither the percent fusion nor the number of nuclei in myotubes was significantly affected by any of the treatments. The quantity of myosin heavy chains (MHCs) was not increased by serum from clenbuterol-treated chickens in either breast or leg muscle cultures; however, the MHC quantity was 50-150% higher in cultures grown in control chicken serum to which 10 and 50 nM clenbuterol had also been added. The B-adrenergic receptor (betaAR) population was 4000-7000 betaARs per cell in cultures grown in chicken serum with leg muscle cultures having approximately 25-30% more receptors than breast muscle Culture. Receptor population was not significantly affected by the presence of clenbuterol or by the presence of serum from clenbuterol-treated chickens. In contrast, the betaAR Population in leg and breast muscle cultures grown in the presence of 10% horse serum was 16,000-18,000 betaARs per cell. Basal concentration of cyclic adenosine 3':5'monophosphate (cAMP) was not significantly affected by the treatments. When cultures grown in chicken serum were stimulated for 10 min with 1 uM isoproterenol, limited increases of 12-20% in cAMP Concentration above the. basal levels were observed. However, when cultures grown in the presence of horse serum were stimulated with 1 uM isoproterenol, cAMP concentration was stimulated 5- to 9-fold above the basal levels. Thus, not only did cells, grown in horse serum have a higher PAR population, but also each receptor had a higher capacity for cAMP synthesis following isoproterenol stimulation. Finally, the hypothesis that clenbuterol exerts its action on muscle protein content by changes in cAMP concentration was tested. No correlation was apparent between basal cAMP concentration and MHC content.

Young, Ronald B.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method are of two types: foil and fiber-optic. Four foil gauges and one or more fiber-optic gauges are mounted on each of the tank-supporting legs. An additional fiber-optic gauge is mounted on an object, made of the same material as that of the tank-supporting legs, that is not subjected to any mechanical load. The reading obtained by the additional fiber-optic gauge is used to compensate for apparent strains caused by changes in temperature. The signals from the foil and fiber-optic gauges are conditioned, then digitized for input to a computer. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. At the time of reporting the information for this article, a set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 microstrain) that occurred during filling and emptying the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. It has been estimated that once the fiber-optic gauges are put into operation, it should be possible to determine fluid masses with 3 percent or less. It may be possible to increase accuracy further by increasing the signal-to-noise ratio through the use of more deformable tank supporting legs.

Figueroa, Jorge↗

Reliability of Upright and Supine Power Measurements Using an Inertial Load Cycle Ergometer

Practical, reliable, and time efficient methods of measuring muscular power are desirable for both research and applied testing situations. The inertial-load cycling method (ILC; Power/Cycle, Austin, TX) requires subjects to pedal as fast as possible against the inertial load of a flywheel for only 3-5 seconds, which could help reduce the time and effort required for maximal power testing. PURPOSE: 1) To test the intramachine reliability of ILC over 3 separate sessions, 2) to compare postural stance (upright vs. supine) during testing, and 3) to compare the maximal power (Pmax) output measured using ILC to that obtained from traditional isokinetic and leg press testing. METHODS: Subjects (n = 12) were tested on 4 non-consecutive days. The following tests were done on the first day of testing: isometric knee extension, isokinetic knee extension at several speeds, isokinetic power/endurance at 180/sec (Biodex System 4), leg press maximal isometric force, and leg press power/endurance. The other 3 days consisted exclusively of ILC testing. Subjects performed 6 ILC tests in an upright position and 6 ILC tests in a supine position on each day. The starting position was counterbalanced. Mixed-effects linear modeling was used to determine if any differences existed between testing days and between upright and supine for Pmax and revolutions per minute at Pmax (RPMpk). Mixed-modeling was also used to calculate intraclass correlation coefficients (ICC) to determine the reliability of the ILC on each testing day for Pmax and RPMpk (ICCs were calculated separately for upright and supine). gKendall fs Tau a h was used to determine the association between ILC Pmax and isokinetic and leg press data. RESULTS: For Pmax, significant differences were found between days 1 and 2 (upright: p = 0.018; supine: p = 0.014) and between days 1 and 3 (upright: p = 0.001; supine: p = 0.002), but not between days 2 and 3 (upright: p = 0.422; supine: p = 0.501). Pmax ICC values were greater than or equal to 0.97 for all days in both positions. Also, no significant differences between upright and supine postures were found for Pmax. No significant differences between days were found for RPMpk; however, there was a significant posture effect (upright greater than supine). Moderate correlations were observed between ILC Pmax and isokinetic and leg press tests (upright: 0.64-0.79, supine: 0.52-0.82). CONCLUSIONS: Overall, ILC is a very reliable test. Since a significant difference was found between day 1 and the other ILC testing days, it is suggested that day 1 of ILC testing should be used as a familiarization session to allow for subject learning. No significant difference in Pmax was seen from test 3 to test 6. However, an increase of 1.3% was observed from test 4 to test 6. Therefore, although 4 tests may be sufficient for most subjects to produce Pmax, in some cases 6 tests may be required. PRACTICAL APPLICATIONS: No differences were seen in Pmax between upright and supine positions despite differing RPMpk. This suggests that ILC testing can be used to provide reliable testing both in an upright position (appropriate for athletes) and in research (e.g., bed rest) or rehabilitation settings where supine testing is necessary. Future research should evaluate whether peak power measurements obtained with the ILC are sensitive to changes such as that observed with training and de-training.

Wickwire, P. J.↗

Test Port for Fiber-Optic-Coupled Laser Altimeter

A test port designed as part of a fiber optic coupled laser altimeter receiver optical system allows for the back-illumination of the optical system for alignment verification, as well as illumination of the detector(s) for testing the receiver electronics and signal-processing algorithms. Measuring the optical alignment of a laser altimeter instrument is difficult after the instrument is fully assembled. The addition of a test port in the receiver aft-optics allows for the back-illumination of the receiver system such that its focal setting and boresight alignment can be easily verified. For a multiple-detector receiver system, the addition of the aft-optics test port offers the added advantage of being able to simultaneously test all the detectors with different signals that simulate the expected operational conditions. On a laser altimeter instrument (see figure), the aft-optics couple the light from the receiver telescope to the receiver detector(s). Incorporating a beam splitter in the aft-optics design allows for the addition of a test port to back-illuminate the receiver telescope and/or detectors. The aft-optics layout resembles a T with the detector on one leg, the receiver telescope input port on the second leg, and the test port on the third leg. The use of a custom beam splitter with 99-percent reflection, 1-percent transmission, and a mirrored roof can send the test port light to the receiver telescope leg as well as the detector leg, without unduly sacrificing the signal from the receiver telescope to the detector. The ability to test the receiver system alignment, as well as multiple detectors with different signals without the need to disassemble the instrument or connect and reconnect components, is a great advantage to the aft-optics test port. Another benefit is that the receiver telescope aperture is fully back-illuminated by the test port so the receiver telescope focal setting vs. pressure and or temperature can be accurately measured (as compared to schemes where the aperture is only partially illuminated). Fiber-optic coupling the test port also allows for the modularity of testing the receiver detectors with a variety of background and signal laser sources without the need of using complex optical set-ups to optimize the efficiency of each source.

Ramos Izquierdo, Luis↗

Robonaut 2 - Building a Robot on the International Space Station

In 2010, the Robonaut Project embarked on a multi‐phase mission to perform technology demonstrations on‐board the International Space Station (ISS), showcasing state of the art robotics technologies through the use of Robonaut 2 (R2). This phased approach implements a strategy that allows for the use of ISS as a test bed during early development to both demonstrate capability and test technology while still making advancements in the earth based laboratories for future testing and operations in space. While R2 was performing experimental trials onboard the ISS during the first phase, engineers were actively designing for Phase 2, Intra‐Vehicular Activity (IVA) Mobility, that utilizes a set of zero‐g climbing legs outfitted with grippers to grasp handrails and seat tracks. In addition to affixing the new climbing legs to the existing R2 torso, it became clear that upgrades to the torso to both physically accommodate the climbing legs and to expand processing power and capabilities of the robot were required. In addition to these upgrades, a new safety architecture was also implemented in order to account for the expanded capabilities of the robot. The IVA climbing legs not only needed to attach structurally to the R2 torso on ISS, but also required power and data connections that did not exist in the upper body. The climbing legs were outfitted with a blind mate adapter and coarse alignment guides for easy installation, but the upper body required extensive rewiring to accommodate the power and data connections. This was achieved by mounting a custom adapter plate to the torso and routing the additional wiring through the waist joint to connect to the new set of processors. In addition to the power and data channels, the integrated unit also required updated electronics boards, additional sensors and updated processors to accommodate a new operating system, software platform, and custom control system. In order to perform the unprecedented task of building a robot in space, extensive practice sessions and meticulous procedures were required. Since crew training time is at a premium, the R2 team took a skills‐based training approach to ensure the astronauts were proficient with a basic skill set while refining the detailed procedures over several practice sessions and simulations. In addition to the crew activities, meticulous ground procedures were required in order to upgrade firmware on the upper body motor drivers. The new firmware for the IVA mobility unit needed to be deployed using the old software system. This also provided an opportunity to upgrade the upper body joints with new software and allowed for limited insight into the success of the updates. Complete verification that the updated firmware was successfully loaded was not confirmed until the rewiring of the upper body torso was complete.

Diftler, Myron↗

Solid State Transformer Architecture and Control Compensation for Common Mode Currents

A high-altitude electromagnetic pulse (HEMP) or similar geomagnetic disturbance (GMD) has the potential to impact the operation of large-scale electric power grids. By introducing low-frequency common-mode (CM) currents, these events can degrade the performance of critical system components, such as large power transformers by introducing CM currents which can lead to magnetic saturation of the transformer core. In this work, a solid-state transformer (SST) is developed to replace susceptible equipment and improve grid resiliency by safely absorbing these CM disturbances. This device will be referred to as a common-mode solid-state transformer (CM-SST). An SST architecture based on a four-legged AC/DC converter is developed. This architecture enables active control of CM signals without disturbing the AC voltages or the real and reactive power delivery capabilities. A system-level model of this architecture is created, and time-domain simulations are performed to evaluate the SST’s performance in response to simulated CM disturbances. A control strategy for mitigating CM current is also investigated. Hamiltonian surface shaping and power flow control (HSSPFC) is used to design a nonlinear controller for the SST’s output inverter. The objectives of the controller are to suppress CM-induced AC current offsets and regulate AC currents to desired setpoints. Nonlinear system analysis is applied to design and validate the controller. Two cases are tested: (a) the proposed four-leg inverter and (b) a standard three-leg inverter. The results show that the proposed controller rapidly mitigates CM disturbances while maintaining high-quality AC current waveforms in the four-leg configuration. Finally, the hardware performance of an SST prototype is evaluated. In particular, the ability of the SST to safely redirect and absorb CM currents is demonstrated, showing how it can protect neighboring conventional transformers in the system. The study confirms that appropriate control laws allow the SST to protect both itself and adjacent transformers during a HEMP or GMD event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High speed shutter

A shutter element is described which is formed by a loop of an electrically conductive ribbon disposed adjacent to the end of a passageway to be shuttered. The shuttered end of the passageway is cut at an acute angle. The two leg portions of the ribbon loop are closely spaced to each other and disposed in a plane parallel to the axis of the passageway. A pulse of high current is switched through the loop to cause the current flowing in opposite directions through adjacent leg portions of the ribbon. This produces a magnetically induced pressure on one of the legs of the ribbon forcing the leg over the end of the passageway in gas tight sealing engagement, and thereby blocking passageway.

Mcclenahan, J. O.↗

Biostereometric analysis of body form - The second manned Skylab mission

Results of biostereometric analyses of the body form of the Skylab 3 crew before and after flight. The Cartesian coordinates of numerous points on the body surface were derived by stereophotogrammetry, and mathematical analysis of the coordinate description allowed computation of the surface area and volume of the body, the volume of body segments, and the area and shape of cross sections. The weight loss in all three crew members was accompanied by a loss in volume distributed between the trunk and legs, with the legs showing the greatest proportional loss. The observed loss of volume apparently resulted from a combined loss of fluid in the abdomen and legs, of muscle in the legs and paraspinal region, and of fat in the abdomen and buttocks.

Whittle, M. W.↗

Adjustable Walker for the Handicapped

Front legs adjust at touch of lever for use on stairs or ramps. Spring loaded legs extend when lever is depressed by user. Legs lock in position when lever is released. Lever mounted on either side of walker or on both sides, so legs operated independently.

Kitts, R. G.↗

Fluid shifts in vascular and extravascular compartments of humans during and after simulated weightlessness

A study is presented of the transcapillary pressures and the possible fluid shifts in muscles and subcutaneous tissue of the lower leg before, during, and after head-down tilt. Results showed that the subjects experienced facial edema, headache, nasal congestion, diuresis, and decreased lower-leg volume in response to 8 hours of 5 degree head-down tilt. Also found were significant decreases in systolic and diastolic pressures 2 hours after initiation of tilt, although blood pressure normalized thereafter. The lower-leg volume, urine output and interstitial fluid pressures of the tibialis anterior muscle and overlying subcutaneous tissue also changed significantly. No significant change was found in the colloid osmotic pressures of blood or interstitial fluid. It is concluded that these results indicate the need for countermeasures to maintain precapillary-muscle tone during long space flights in order to prevent swelling of lower-leg tissues upon readjustment to earth's gravity.

Hargens, A. R.↗

Fluid shifts and muscle function in humans during acute simulated weightlessness

The acute effects of simulated weightlessness on transcapillary fluid balance, tissue fluid shifts, muscle function, and triceps surface reflex time were studied in eight supine human subjects who were placed in a 5 degrees head-down tilt position for 8 hr. Results show a cephalic fluid shift from the legs as indicated by facial edema, nasal congestion, increased urine flow, decreased creatinine excretion, reduced calf girth, and decreased lower leg volume. The interstitial fluid pressure in the tibialis anterior muscle and subcutaneous tissue of the lower leg was found to fall significantly, while other transcapillary pressures (capillary and interstitial fluid colloid osmotic pressures) were relatively unchanged. The total water content of the soleus muscle was unchanged during the head-down tilt. After head-down tilt, isometric strength and isokinetic strength of the plantar flexors were unchanged, while the triceps surae reflex time associated with plantar flexion movement slowed slightly. These results demonstrate a dehydration effect of head-down tilt on muscle and subcutaneous tissue of the lower leg that may affect muscle function.

Hargens, A. R.↗

Inhibition of the spider heartbeat by gravity and vibration

The rate and vigor of the spider heartbeat is controlled by an external pacemaker. A mechanical feature of the spider cardio-vascular system is the production of high serum pressure in the prosoma and the legs. This appears to be the source for leg extension. The lyriform organ on the patella of the leg is sensitive to vibratory and kinesthetic stimuli. This sensitivity depends upon the degree of leg extension. Thus the activity of the heart and the response characteristics of the sense receptor are related. The effect of a supra-threshold vibratory or gravitational stimulus is to produce an inhibition and a tachycardia of the spider heartbeat.

Finck, A.↗

Changes in volume, muscle compartment, and compliance of the lower extremities in man following 30 days of exposure to simulated microgravity

To investigate the relationship between leg compliance and a reduction in the size of the leg muscle compartment due to long-duration exposure to microgravity, eight men were exposed for 30 d of continuous 6-deg headdown tilt, and changes in vascular compliance (vol pct/mm Hg x 100) of the calf and serial circumferences of the thigh and the calf were measured before, during, and after the tilt. It was found that the tilt exposure led to calculated leg volume decreases of 9.9 percent in the calf and of 4.5 in the thigh. Leg compliance was found to increase from 3.9 to about 4.9. Calf compliance measured before and after bedrest was found to be inversely related to calf-muscle compartment cross-sectional area (CSA).

Convertino, Victor A.↗

Characteristics and preliminary observations of the influence of electromyostimulation on the size and function of human skeletal muscle during 30 days of simulated microgravity

The effect of transcutaneous electromyostimulation (EMS) on the development of atrophy and the loss of strength in lower limb musculature in humans exposed to microgravity was determined in three subjects who received EMS twice daily in a 3-d on/1-d off cycle on their dominant leg during 30 days of bedrest. The output waveform from the stimulator was sequenced to the knee extensors, knee flexors, ankle extensors, and ankle flexors, and caused three isometric contractions of each muscle group per minute. It was found that, in the dominant leg, EMS acted to attenuate the changes caused by bedrest, such as reductions in the leg volume, muscle compartment size, cross-sectional area of slow- and fast-twitch fibers, strength, and aerobic enzyme activities, and an increase in leg compliance.

Duvoisin, Marc R.↗