Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A data-driven sensor placement approach for detecting voltage violations in distribution systems

Stochastic fluctuations in power injections from distributed energy resources (DERs) combined with load variability can cause constraint violations (e.g., exceeded voltage limits) in electric distribution systems. To monitor grid operations, sensors are placed to measure important quantities such as the voltage magnitudes. Here, in this paper, we consider a sensor placement problem which seeks to identify locations for installing sensors that can capture all possible violations of voltage magnitude limits. We formulate a bilevel optimization problem that minimizes the number of sensors and avoids false sensor alarms in the upper level while ensuring detection of any voltage violations in the lower level. This problem is challenging due to the nonlinearity of the power flow equations and the presence of binary variables. Accordingly, we employ recently developed conservative linear approximations of the power flow equations that overestimate or underestimate the voltage magnitudes. By replacing the nonlinear power flow equations with conservative linear approximations, we can ensure that the resulting sensor locations and thresholds are sufficient to identify any constraint violations. Additionally, we apply various problem reformulations to significantly improve computational tractability while simultaneously ensuring an appropriate placement of sensors. Lastly, we improve the quality of the results via an approximate gradient descent method that adjusts the sensor thresholds. We demonstrate the effectiveness of our proposed method for several test cases, including a system with multiple switching configurations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Static characterization of a soft elastomeric capacitor for non destructive evaluation applications

A large and flexible strain transducer consisting of a soft elastomeric capacitor (SEC) has been proposed by the authors. Arranged in a network setup, the sensing strategy offers tremendous potential at conducting non-destructive evaluation of large-scale surfaces. In prior work, the authors have demonstrated the performance of the sensor at tracking strain history, localizing cracks, and detecting vibration signatures. In this paper, we characterize the static performance of the proposed SEC. The characterization includes sensitivity of the signal, and temperature and humidity dependences. Tests are conducted on a simply supported aluminum beam subjected to bending as well as on a free standing sensor. The performance of the SEC is compared against off-the-shelf resistance-based strain gauges with resolution of 1 με. A sensitivity of 1190 pF/ε is obtained experimentally, in agreement with theory. Results also show the sensor linearity over the given level of strain, showing the promise of the SEC at monitoring of surface strain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Graphene-elastomer nanocomposites based flexible piezoresistive sensors for strain and pressure detection

Highlights: • Fabricating flexible piezoresistive sensors based on PDMS/GNPs nanocomposites. • Positive strain sensitive capacity occurs during increasing pressure-loading process but before the threshold of forces loading. • Tunable strain and pressure sensitivity are achieved by controlling GNPs incorporation, and improved to 140 and 260 at 5 wt% GNPs respectively. • Superior dynamic correspondence with applied pressure and relatively high repeatability. • Application of the GNPs/PDMS piezoresistive sensors as detecting the finger motions. - Abstract: Strain and pressure sensitive flexible piezoresistive sensors have been fabricated based on nanocomposites of graphene nanoplatelets (GNPs) and Polydimethylsiloxane (PDMS) elastomer. The strain detective sensors show positive piezoresistive characteristic under diverse levels of static strain up to 20% due to the flexibility and stretchability of PDMS elastomer. Tunable strain sensitivity of GNPs/PDMS piezoresistive sensors can be achieved by controlling GNPs incorporation into PDMS elastomer, which will be improved to 140 at 5 wt% GNPs concentration. In addition, pressure sensitive response, which exists when the pressure loading is less than threshold pressure, also can be observed in GNPs/PDMS piezoresistive sensors. The GNPs network-elastomer nanocomposite based pressure sensors show tunable piezoresistivity in the ranges of ∼260 under increasingly higher GNPs concentrations. During the cyclic pressure loading, the pressure sensitive behavior of GNPs/PDMS nanocomposites manifests a superior dynamic correspondence with applied pressure while the resistance response can retain at a relatively high level under multiple loading-unloading cycles. Since the GNPs/PDMS piezoresistive sensors can not only respond to subtle bending but also distinguish them accurately for detecting the finger motions, it will make the GNPs/PDMS nanocomposite a good candidate for artificial skin and wearable sensor applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Development Plan for Ultrasonic Pressure Sensors [Slides]

Current light water reactors (LWRs) utilize differential pressure cells, based on strain gauges, which are remotely located from the reactor vessel via impulse lines. These pressure sensors are used to measure liquid level within the vessel and to give a general indication of system health with regard to leaks and flow system fouling. The advanced reactor types currently under development generally operate at higher temperatures than light-water reactors and utilize coolants that may be highly corrosive (i.e., liquid metals). They will use pressure measurements for varied measurands, such as level and flow rate, as well as indications of accident conditions or off-normal operating conditions. More robust pressure sensors are needed to address these more challenging conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and gas sensing properties of NiO/SnO2 hierarchical structures toward ppb-level acetone detection

Highlights: • The NiO/SnO{sub 2} hierarchical structures with different Ni contents have been prepared by facile hydrothermal method. • The NiO/SnO{sub 2} sensors exhibit the enhanced gas sensing performances comparing with pure SnO{sub 2}. • The Ni{sub 1}Sn{sub 3} sensor exhibits higher response, fast response/recovery time for acetone detection. - Abstract: We have synthesized pristine SnO{sub 2} and NiO/SnO{sub 2} hierarchical structures by a facile hydrothermal method. Structural and morphological characterizations of the obtained NiO/SnO{sub 2} samples were systematically studied using XRD, SEM, TEM and XPS. Meanwhile, gas-sensing properties of the as-fabricated pristine SnO{sub 2} and NiO/SnO{sub 2} sensor devices were investigated toward ppb-level acetone detection. The measured results show that the Ni{sub 1}Sn{sub 3} gas sensor can reach a response of 20.18 toward 50 ppm acetone under optimum operating temperature (300 °C), which is about 3.3 times higher than that of pristine sensor. Moreover, the Ni{sub 1}Sn{sub 3} gas sensor also exhibits fast response/recovery time (2 s/9 s), low detection limit (10 ppb) and good selectivity. We attribute the enhanced gas-sensing properties of NiO/SnO{sub 2} hierarchical structures to the synergetic effect as well as p-n heterojunction between the NiO and SnO{sub 2} structures.

36 MATERIALS SCIENCE↗

Development of a 1 x N Fiber Optic Sensor Array for Carbon Sequestration Site Monitoring

A fiber sensor array for sub-surface CO 2 concentrations measurements was developed for monitoring geologic carbon sequestration sites. The fiber sensor array uses a single temperature tunable distributed feedback (DFB) laser operating with a nominal wavelength of 2.004 μm. Light from this DFB laser is direct to one of the 4 probes via an in-line 1 x 4 fiber optic switch. Each of the 4 probes are buried and allow the sub-surface CO 2 to enter the probe through Millipore filters that allow the soil gas to enter the probe but keeps out the soil and water. Light from the DFB laser interacts with the CO 2 before it is directed back through the in-line fiber optic switch. The DFB laser is tuned across two CO 2 absorption features where a transmission measurement is made allowing the CO 2 concentration to be retrieved. The fiber optic switch then directs the light to the next probe where this process is repeated allowing sub-surface CO 2 concentration measurements at each of the probes to be made as a function of time. The fiber sensor array was deployed for fifty-eight days beginning June 19, 2012 at the Zero Emission Research Technology (ZERT) field site where sub-surface CO 2 concentrations were monitored. Background measurements indicate the fiber sensor array can monitor background levels as low as 1,000 parts per million (ppm). A thirty four day sub-surface release of 0.15 tones CO 2 /day began on July 10, 2012. The elevated subsurface CO 2 concentration was easily detected by each of the four probes with values ranging to over 60,000 ppm, a factor of greater than 6 higher than background measurements. The fiber sensor array was also deploy at the Big Sky Carbon Sequestration Partnership (BSCSP) site in north-central Montana between July 9th and August 7th, 2013 where background measurements were made in a remote sequestration site with minimal infrastructure. The project provided opportunities for two graduate students to participate in research directly related to geologic carbon sequestration. Furthermore, commercialization of the technology developed is being pursued with five different companies via the Department of energy SBIR/STTR program

47 OTHER INSTRUMENTATION↗

Calibration and field deployment of low-cost sensor network to monitor underground pipeline leakage

Recent technological advances in methane detection have improved leak detection and repair. However, current methods to reliably measure methane concentrations rely on expensive instruments or demand significant labor input. There is interest in using affordable methane sensors that are responsive to ppmv level changes in methane concentrations in both urban and rural environments for monitoring underground natural gas pipeline leaks. This is especially relevant for situations where potentially significant leaks cannot be repaired immediately or smaller leaks that require long-term monitoring and further evaluation. In this work, a low-cost sensor unit, equipped with a metal oxide sensor, was designed, built, and calibrated over a wide range of methane concentrations and environmental conditions in preparation for field application. A network of these sensors was then installed at the test site and used to measure methane concentrations at ground level above known sub-surface natural gas emissions which emulated underground gas pipeline leaks. This low-cost sensor network measured over 4 days total for the two different known leakage rates. Results demonstrate that the sensors can continuously measure relative methane variability for extended periods but require calibration for a wide range of temperature and humidity conditions to properly determine absolute gas (i.e., methane) concentrations. Furthermore, when a regression analysis was conducted to evaluate the effects of meteorological parameters on methane concentration, air temperature and wind speed have strong impacts on the concentration. Overall, the network approach allows improved identification of leak location and monitoring of underground natural gas leaks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-Layer Self-Adaptive/Self-Aware System Software for Exascale Systems

The extreme level of parallelism coupled with the limited available power budget expected in the exascale era brings unprecedented challenges that demand optimization of performance, power and resiliency in unison. Scalability on such systems is of paramount importance, while power and reliability issues may change the execution environment in which a parallel application runs. To solve these challenges exascale systems will require an introspective system software that combines system and application observations across all system stack layers with online feedback and adaptation mechanisms. In this paper we propose the design of a novel self-aware, self-adaptive system software in which a kernel-level Monitor, which continuously inspects the evolution of the target system through observation of Sensors, is combined with a user-level Controller, which reacts to changes in the execution environment, explores opportunities to increase performance, save power and adapts applications to new execution scenarios. We show that the monitoring system accurately monitors the evolution of parallel applications with a runtime overhead below 1-2%. As a test case, we design and implement a user-runtime system that aims at optimizing application’s performance and system power consumption on complex hierarchical architectures. Our results show that our adaptive system reaches 98% of performance efficiency of manually-tuned applications.

High Performance computing, Self-aware/self-adapti↗

Electrodermal activity as a proxy for sweat rate monitoring during physical and mental activities

Electrodermal activity has long been used for mental activity monitoring by measuring skin conductance at specific locations, such as fingertips, with high sweat gland density. However, electrodermal activity has not been considered useful for physical activity monitoring, where large sweat volumes are generated, resulting in the accumulation of sweat at the skin–electrode interface and, thus, preventing further dynamic response to sweating events. Here we show that electrodermal activity can be used as a proxy for sweat loss measurement under both low and high physical activity levels. We use wearable sweat sensors that consist of water-permeable electrodes and microfluidic-based sweat analysers, and show that skin conductance is proportional to the instantaneous sweat loss. We demonstrate that sweat loss during exercise can be estimated by integrating skin conductance over time, which can be applied to assess the body hydration status of exercisers. From multisite measurements of skin conductance, we show that the wrist, forearm and upper arm are reflective of physical activity levels, whereas the finger is indicative of mental activity. Simultaneous measurement of two different sites selectively decouples mental and physical activities.

Biomedical engineering↗

Analysis of dynamic radiation level changes using surface networks [Book Chapter]

The Fukushima nuclear accident reminds us of severe risk of radioactive substances. Citizen scientists voluntarily collect and share radiation data using geo-tagged sensors for radiation preparedness. However, radiation levels are affected by a number of factors including for example weather conditions, naturally occurring radioactive materials (NORM), and large marble structures. It is therefore difficult to determine whether a higher radiation level comes from a normal variation in background or not. This research analyzes the radiation changes using surface networks that can be used to characterize complex surfaces. A new algorithm has been developed to identify salient peaks and their hills by merging insignificant peaks recur-sively. Salient peaks and their hills are converted into graphs. The structural similarities of graphs were compared over time. The radiation measurements in the city of Koriyama, Japan were analyzed as a case study. The results demonstrated that structural analysis of dynamic radiation levels revealed stable changes, while numeric analysis of radiation levels presented statistically significant differences. This method is able to detect radiation level changes irrespective of background variations.

97 MATHEMATICS AND COMPUTING↗

Source Localization using Stochastic Approximation and Least Squares Methods

This paper presents two approaches to locate the source of a chemical plume; Nonlinear Least Squares and Stochastic Approximation (SA) algorithms. Concentration levels of the chemical measured by special sensors are used to locate this source. Non-linear Least Squares technique is applied at different noise levels and compared with the localization using SA. For a noise corrupted data collected from a distributed set of chemical sensors, we show that SA methods are more efficient than Least Squares method. SA methods are often better at coping with noisy input information than other search methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-Efficient and Comfortable Buildings through Multivariate Integrated Control (ECoMIC)

This project aims to develop an integrated control solution for enhanced energy efficiency and user comfort in commercial buildings. The developed technology is a zone-based control framework that minimizes energy usage while maintaining occupants’ visual and thermal comfort through control of electric lights, motorized venetian blinds and thermostats. The control framework is designed following a modular, scalable and flexible architecture to facilitate easy integration with exiting building management systems. The control framework contains two key algorithms: 1) the lighting load balancing algorithm and 2) the thermostat control algorithm. The lighting load balancing algorithm adopts a model-based closed-loop control approach to determine the optimal electric light and venetian blind settings. It is formulated into an optimization problem with minimizing lighting-related energy consumptions as the objective and delivering adequate task light and preventing daylight glare as the constraints. The thermostat control algorithm is based on a well-established thermal comfort model and formulated as a root-finding problem to dynamically determine the optimal thermostat setpoint for both energy savings and improved thermal comfort. To address building-wide scalability, a system architecture was developed for the zone-based control technology. Three levels of services are defined in the architecture: external services, facility level services and zone level services. The zone-level service includes the control algorithms described above as well as the corresponding interfaces, profiles, sensors and actuators to realize the zone controller. The facility level services connect to the zones through a backbone network, handle supervisory level information and controls, and thus facilitate building-wide scalability. The external services provide communication capability to entities outside of the building for grid interaction and remote access. Various aspects of the developed control technology were evaluated and verified through both simulations and testbed implementations. Simulations coupling a DOE medium office reference building in EnergyPlus building simulation software and a prototype controller in Matlab were performed. During summer time in a mixed-humid climate zone, the simulations revealed reductions of 27% and 42% in electric lighting load and cooling load, respectively, when compared to an advanced base case with daylight dimming and blinds automatically tilted to block direct sun. Two single-room testbeds were established. The testbed at Philips Lighting business building (Rosemont, IL) was designed for quantifying energy performance of integrated controls. This particular implementation achieved 40% and 79% savings on lighting and HVAC energy, respectively, compared to a relatively simple base case operated on predefined schedules. While the resulting energy savings was very encouraging, it should be noted that there may be several caveats associated with it. 1) The test was run during late spring and early summer, and the savings numbers might not be directly used to extrapolate the annual energy savings. 2) Due to the needs for separate control and metering of the small-scale demonstrator within a large building, the HVAC system, hence the corresponding savings, did not represent a typical energy code-compliant design. 3) The light level in the control case was regulated at a particular setpoint, which was lower than then the full-on light level in the base case, and the savings resulted from tuning down the light level to the setpoint was not attributable to the contribution of the developed technology. The testbed at the Lawrence Berkeley National Laboratory (Berkeley, CA) specifically focused on glare control integration, and has demonstrated the feasibility and capability of the glare detection and prevention technique. While the short one-month test in this testbed provided a functional indication of the developed technology, and it would require at least a full solstice-to-solstice cycle to ruinously quantify the performance, which was not possible within the project timeframe. There are certain limitations inherited from the operational assumptions, which could potentially affect the effectiveness and applicability of the developed control technologies. The system takes a typical ceiling-mounting approach for the photosensor locations, and therefore, the control performance relies on proper commissioning or the built-in intelligence of the photosensor for pertinent task light level estimations. For spaces where daylight penetration diminishes significantly deeper into the zone, certain modification to the control algorithms is required to accommodate multiple lighting control subzones and the corresponding sensors for providing a more uniform light level across the entire zone. Integrated control of visual and thermal comfort requires the lighting control zone and thermal control zone to coincide with each other. In other words, the area illuminated by a lighting circuit needs to be the same area served by the thermostat. Thus, the original zoning will potentially constrain the applicability of this technology in retrofitting projects. This project demonstrated the technical feasibility of a zone-based integrated control technology. From the simulation results and testbed implementations, up to 60% lighting energy savings in daylit areas relative to a “no-controls” case can easily be achieved. A 20% reduction of whole building energy consumption is also attainable. In the aspect of occupant comfort, the testbed demonstrated the ability to maintain specified light level on the workplane while promptly mitigate daylight glare 90% of the time. The control system also managed to maintain the thermal environment at a comfortable level 90% of the time. The aspect of system scalability was guaranteed by the system architecture design, based on which the testbeds were instantiated. Analysis on the aspect of economic benefit has yielded an about 6-year payback time for a medium-sized building, including the installation of all hardware and software, such as motorized blinds and LED luminaires. The payback time can be significantly reduced if part of the hardware is already in place for retrofitting projects. It needs to be noted that since the payback analysis was partly based on the testbed performance results, it is constrained by the caveats associated with the testbed implementations. The main uncertainty lies in the contribution from the space conditioning energy savings as it was non-trivial to realistically configure a room-size HVAC system for directly extrapolating whole-building HVAC energy savings. It is recommended to further evaluate the developed technology at a larger scale, where the lighting and HVAC energy consumption can be realistically measured at the building level, to more rigorously quantify the performance potentials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance of CMOS pixel sensor prototypes in ams H35 and aH18 technology for the ATLAS ITk upgrade

Pixel sensors based on commercial high-voltage CMOS processes are an exciting technology that is considered as an option for the outer layer of the ATLAS inner tracker upgrade at the High Luminosity LHC. Here, charged particles are detected using deep n-wells as sensor diodes with the depleted region extending into the silicon bulk. Both analog and digital readout electronics can be added to achieve different levels of integration up to a fully monolithic sensor. Small scale prototypes using the ams CMOS technology have previously demonstrated that it can achieve the required radiation tolerance of 10(15) n(eq)/cm(2) and detection efficiencies above 99.5%. Recently, large area prototypes, comparable in size to a full sensor, have been produced that include most features required towards a final design: the H35demo prototype produced in ams H35 technology that supports both external and integrated readout and the monolithic ATLASPix1 pre-production design produced in ams aH18 technology. Both chips are based on large fill-factor pixel designs, but differ in readout structure. Performance results for H35DEMO with capacitively-coupled external readout and first results for the monolithic ATLASPix1 are shown.

ATLAS ITk upgrade↗

Severe accident: hardening of standards and qualification requirements for nuclear pressure transmitters - 319

Nuclear power stations are designed according to the nuclear safety principle: the achievement of proper operating conditions, prevention of accidents or mitigation of accident consequences, resulting in protection of workers, the public and the environment from undue radiation hazards. This principle is applicable from the design to the dismantling of the power station, including normal and accident (and post-accident) operation. To take into account the world experience (incident or accident as Fukushima), international safety authorities recommends to reinforce safety functions and qualification requirements level. Concerning the instrumentation, devices like sensors are mainly impacted by the following constraint improvements: - Radiation resistance in normal and accident conditions: - Higher total dose; - Dose Rate; - Nature of radiation; - Pressure and Temperature profile in terms of: - Magnitude of pressure and / or temperature (higher); - Duration of higher constraints (longer). All these specifications induce: - The creation of a new qualification level - Severe Accident (SA) or equivalent; - An impact on the sensor technology to improve the resistance to harsh environment. Finally, the paper will present in details the evolution of the requirements and will sum up the advantages and disadvantages of different technologies to meet the severe accident conditions. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Multiscale and Multivariate Transportation System Visualization for Shopping District Traffic and Regional Traffic

In this paper, we present a suite of visualization techniques for sensor-based transportation system data at different scales to facilitate the exploration of interconnected traffic dynamics at intersections and highways. Additionally, these techniques are designed for analyzing multivariate traffic data from radar-based highway sensors and camera-based intersection sensors recording turn movements and vehicle speed, in the Chattanooga Metropolitan Area, with the capability of (a) revealing multiscale mobility patterns using different levels of data aggregation (e.g., individual sensor for microscale, multiple sensors along a corridor for mesoscale, and a larger number of sensors across the region for macroscale visualization) at different intervals (e.g., 5-min intervals, time of day, full day, and day-of-the-week), and (b) exploring the spatial variation of multiple traffic-related variables (e.g., volumes, speeds, turn movements, and traffic light colors) provided by the sensors. We close with a case study to demonstrate the effectiveness of our multiscale and multivariate visualization techniques. At microscale, we focused on intersection data from a shopping district around Shallowford Road in East Chattanooga. For mesoscale visualization, we studied the Shallowford Road corridor and an adjacent stretch of I-75. At macroscale, we included highway data from the Chattanooga Metropolitan Area. All visualizations were integrated into a web-based situational awareness tool to promote user access and interaction. At a minimum, each visualization provides the option for selecting dates for real-time (depending on sensor availability) and historical data, and additional information on hovering, though most provide more detailed information, including different views of the selected data, or interactive highlights.

33 ADVANCED PROPULSION SYSTEMS↗

Demonstration Report: Handheld UXO Discriminator, SERDP No. MR-1667

In 2003, the Defense Science Board observed: 'The problem is that instruments that can detect the buried UXOs also detect numerous scrap metal objects and other artifacts, which leads to an enormous amount of expensive digging. Typically 100 holes may be dug before a real UXO is unearthed! The Task Force assessment is that much of this wasteful digging can be eliminated by the use of more advanced technology instruments that exploit modern digital processing and advanced multi-mode sensors to achieve an improved level of discrimination of scrap from UXOs.' In keeping with these remarks and with prior funding (UX-1225, MM-0437, and MM-0838), the LBNL group has successfully designed and built the cart-mounted Berkeley UXO Discriminator (BUD) and demonstrated its performance at various test sites (cf. Gasperikova et al., 2007, 2008, and 2009). Because hand-held systems have the advantage of being lightweight, compact, portable, and deployable under most site conditions, they are particularly useful in areas of dense vegetation or challenging terrain. In heavily wooded areas or areas with steep or uneven terrain, hand-held sensors may be the only suitable device for UXO detection and discrimination because it can be carried through spaces that the operator could walk through or at least approach. Furthermore, it is desirable to find and characterize a metallic object without the need to accurately locate the sensors at multiple positions around the target. The ideal system would thus locate and characterize the target from a single position of the sensor and indicate to the operator where to flag the target for subsequent study. Based on these considerations, we designed and built a sensor package in a shape of a 14-in (0.35 m) cube. This hand-held prototype incorporates the key features of the cart-mounted system - (a) three orthogonal transmitters and ten pairs of receivers, and (b) difference or gradient measurements that significantly reduce the ambient and motion noise, and greatly enhance the sensitivity to the gradients of the target. The system characterizes the target from a single position. Results from a local test site were in a good agreement with theoretical performance calculations of such a device. This survey was designed to demonstrate performance of the system under realistic survey conditions at the Aberdeen Proving Ground (APG) in Aberdeen, MD. The survey was preformed in an area with known items ('Calibration Grid'), and in a seeded blind test area (the 'Blind Test Grid'). The ground truth for the surveys conducted on the Blind Test Grid was withheld from the testers. Only the graded test scores based on target detection and target classification were provided. For more information, see http://aec.army.mil/usaec/technology/uxo01c03.html.

54 ENVIRONMENTAL SCIENCES↗