Search NASASearch

SEARCH · Search NASA

Results for “linear accelerator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

The Upgrade of the SNS Extraction Kicker Power Supplies for the Proton Power Upgrade

The Proton Power Upgrade (PPU) project at the Spallation Neutron Source (SNS) aims to enhance the linear accelerator's power output from 1.4 to 2.8 megawatts. A critical focus lies on upgrading the Extraction Kicker Power Supplies to handle the amplified beam power. The existing capacitor charging power supplies lacked the capability to charge the Blumlein-type Pulse Forming Network (PFN) to the required 40 kV at a repetition rate of 60 Hz. To address this limitation, an initial solution involving the use of a resonant charging circuit was proposed. However, a challenge arose with a self-firing issue in the thyristor switch, which proved unsolvable within the given timeframe. Facing a critical decision point in the project, an alternative approach was explored: integrating a supplementary power supply to enhance the overall power capacity. This solution was tested and ultimately chosen as the path forward. To accommodate the additional power supply, the power distribution system had to undergo upgrades. Throughout this endeavor, a comprehensive examination of the system took place, with meticulous identification of key components. This paper delves into the technical challenges encountered during the process and the corresponding solutions that were implemented.

Tan, Yugang [ORNL] (ORCID:0000000155968252)

Theoretical investigation of plasma wave generation by pulsed electron beams in space

Here, we report theoretical calculations of plasma wave generation in the whistler modes and in the extraordinary modes, by pulsed electron beams in a magnetized plasma. The numerical simulations of the wave generation take into account the longitudinal expansion of the electron beam due to the space charge force and the energy spread. The work presented in this article provides predictions for the wave generation performance of the beam plasma interactions experiment (Beam PIE), where pulsed electron beams were produced by a spaceborne radio frequency (RF) linear accelerator. We also theoretically explore the desirable properties of the pulsed electron beam for future space experiments, which will be the next step toward eventually demonstrating the radiation-belt remediation (RBR).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Extraction and Injection in the Electron Injector for the Electron-Ion Collider

The electron injector for the Electron-Ion Collider (EIC) consists of a linear accelerator, a beam accumulation ring, and the Rapid Cycling Synchrotron (RCS) before the electrons are injected into the Electron Storage Ring (ESR) and collided. Extraction out of the RCS is complicated by limited space and the nominal beam pipe aperture, while injection into the ESR is complicated due to the limitation of kicker strength, so that the kickers will not impact the proton beam in the adjacent Hadron Storage Ring (HSR); additionally, the ESR kickers must also provide enough kick to the stored bunch for the swap-out scheme. This paper covers the injection into and extraction out of the RCS, as well as injection into the ESR, detailing layout, optics, and anticipated parameters of the septa and different kickers.

Deitrick, K. [Thomas Jefferson National Accelerato

RF AND MECHANICAL DESIGN OF A 915 MHz SRF CAVITY FOR CONDUCTION-COOLED CRYOMODULES

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi

JAXtronomy: A JAX port of lenstronomy

Gravitational lensing is a phenomenon where light bends around massive objects, resulting in distorted images seen by an observer. Studying gravitationally lensed systems provides insights into cosmology and astrophysics, including constraints of the expansion rate of the Universe and the distribution of dark matter. Thus, we introduce JAXtronomy, a re-implementation of the gravitational lensing software package lenstronomy (Birrer, 2021; Birrer & Amara, 2018) using JAX (Bradbury et al., 2018). JAX is a Python library that uses an accelerated linear algebra (XLA) compiler to improve the performance of computing software. Our core design principle of JAXtronomy is to maintain an identical API to that of lenstronomy. The main JAX features utilized in JAXtronomy are just-in-time compilation, which can lead to significant reductions in execution time, and automatic differentiation, which allows for the implementation of gradient-based algorithms that were previously impossible. Additionally, JAX allows code to be run on GPUs or parallelized across CPU cores, further boosting the performance of JAXtronomy.

astronomy

Final Physics Design of Proton Improvement Plan-II at Fermilab

This paper presents the final physics design of the Proton Improvement Plan-II (PIP-II) at Fermilab, focusing on the linear accelerator (Linac) and its beam transfer line. We address the challenges in longitudinal and transverse lattice design, specifically targeting collective effects, parametric resonances, and space charge nonlinearities that impact beam stability and emittance control. The strategies implemented effectively mitigate space charge complexities, resulting in significant improvements in beam quality—evidenced by reduced emittance growth, lower beam halo, decreased loss, and better energy spread management. This comprehensive study is pivotal for the PIP-II project's success, providing valuable insights and approaches for future accelerator designs, especially in managing nonlinearities and enhancing beam dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

RF and Mechanical Design of a 915 MHz SRF Cavity for Conduction-Cooled Cryomodules

Conduction-cooled SRF niobium cavities are being developed for use in compact, continuous-wave electron linear accelerators for a variety of industrial applications. A 915 MHz two-cell cavity has been designed to achieve an energy gain of 3.5 MeV. The design of the cell shape aims at minimizing the peak surface magnetic field. Field flatness is achieved by adjusting the length of the outer end half-cells. The higher-order mode analysis shows that absorbers are not required for a moderate beam current of 5 mA. One of the beam tubes has two side-ports for insertion of coaxial fundamental power couplers. The mechanical design and analysis were done to maintain a stress near or less than 15.5 MPa for all anticipated loading conditions. This is half the measured yield strength and is to provide relief from creep when cavity is evacuated and stored with outside atmospheric pressure.

Ciovati, Gianluigi

Real time heat load calculation software based on EPICS for Fermilab PIP-II CM tests

Fermilab has a project to improve the proton beam energy which is called PIP-II (the 2nd Proton Improvement Plan). There is a superconducting linear accelerator, LINAC, to improve the proton beam power and the LINAC consists of 5 types of cryomodules (CM), 1 HWR CM, 2 SSR1 CM, 4 SSR2 CM, LB650 CM, and HB650 CM. The prototypes of these cryomodules are being tested at Fermilab’s CryoModule Test Facility (CMTF). Heat load measurements are an important part of the prototype CM testing. The CMTF cryogenic control system was developed based on the ACNET (Accelerator Control NETwork) for CM testing for other projects, but the PIP-II cryogenic control system will be implemented using the Experimental Physics and Industrial Control System (EPICS). As part of the prototype CM testing campaign an EPICS based control system has been implemented at CMTF. This EPICS cryogenic control system includes real time heat load calculation software utilizing the Fortran implementation of Hepak. This paper details the real time heat load calculation software developed for the prototype CM testing including the first results from the HB 650 CM.

Yoon, S. [Fermilab]

Resistive Wall Simulations for the DARHT Multi-Pulse Test Line

The multi-pulse test line (MPTL) presently under T development at the Dual Axis Radiography Hydrodynamic Test (DARHT) facility may have several meters of drifting beam transport without external magnetic focusing field. The absence of external magnetic focusing is the worst case for growth of the resistive-wall instability. This instability is usually considered to be strictly a long-pulse (low-frequency) problem, but has been theoretically shown to couple the multiple pulses in a long pulse train, such as are expected to be the subject of experimentation on the MPTL. In this note, we explore the resistive wall instability in the MPTL parameter range using our LAMDA beam dynamics code. (LAMDA stands for Linear Accelerator Model for DARHT)

43 PARTICLE ACCELERATORS

Design and calculations for HWR Strongback

The PIP-II Superconductive Linac is a linear accelerator that provides the first stage of beam acceleration. The velocity increase is achieved through a sequence of different cryomodules, where all the cavities are aligned to form a continuous string. The cryomodule team is currently developing a spare for the HWR cryomodule. This spare will not be an exact replica of the existing one, but rather will be based on the SSR f650 cryomodule design created for PIP-II . Each cavity , magnet , and coupler form a unit, with a total of eight units per string. These components, together with additional equipment (such as piping , the thermal shield , and beamline interconnections ), are supported by the Strongback . The aim of this project is to develop a brand-new Strongback design for HWR cavities, and to perform the related analyses and calculations in order to meet the required specifications.

43 PARTICLE ACCELERATORS

Development of high throughput light-sheet fluorescence lifetime imaging microscopy for 3D functional imaging of metabolic pathways in plant and microorganisms (Final Technical Report)

This research program will enable new biochemical contrast in the nanosecond lifetime domain through use of the recently demonstrated electro-optic fluorescence lifetime imaging technique (EO-FLIM) for wide-field lifetime imaging. The Stanford/Stanford Linear Accelerator Center multidisciplinary collaboration -- physics, applied physics, and structural biology -- will develop a light-sheet fluorescence lifetime imaging microscope for functional studies of microbial and plant metabolic pathways and dynamic interactions between plants and microorganisms in the rhizosphere. The proposed approach overcomes the imaging time bottleneck associated with existing fluorescence lifetime imaging methods. Initial demonstrations have shown a factor of 100,000 improvement in photon throughput compared to existing methods. High photon efficiency allowed the first wide-field fluorescence lifetime imaging of single molecules. Recent work has improved the technique’s repetition rate to enable compatibility with mode-locked lasers and demonstrated the combination of wide-field fluorescence lifetime imaging with super-resolution localization microscopy, observations of single molecule dynamics, and observation of donor lifetime quenching in single-molecule imaging. These results were achieved on standard camera sensors and would not have been possible with other wide-field approaches. The throughput and photon economy of the EO-FLIM method enables new BER-relevant imaging opportunities. In particular, scanned single- and two-photon light-sheet excitation will be used to achieve volumetric imaging with time-domain contrast.

47 OTHER INSTRUMENTATION

Harvesting Isotopically Pure Ac-225 from Ra-225 Produced in Thorium Target Spallation Reaction

A method for isolating Ra-225 from linear accelerator irradiated Th metal chemical processing waste streams has been established. Separating Ra-225 from the complex matrix following proton irradiation of Th metal provides a source of isotopically pure Ac-225 free of the Ac-227 impurity that is present in accelerator-produced Ac-225. Ra isotopes are first separated from the irradiated Th target via cation exchange methods. Importantly, the Ra-containing fraction is cleaned from residual citrate via dilute nitric acid washes (0.5 M) on AG50W-X8 resin. The mixed Ra isotopes are then further purified from Ba-140 impurity using a Sr resin column. Ra elutes through the resin with successive washes of 2.5 M HNO 3 while Ba-140 is retained. Ac-225 is then harvested by loading the Ra content onto an AG50W-X8 cation exchange column where the Ra-225 parent is eluted with 2.5 M HNO 3 before the Ac-225 daughter is eluted with 8 M HNO 3 .

07 ISOTOPE AND RADIATION SOURCES

Microstructure and 77K mechanical properties of electron beam welded Cu101- Inconel 625 joints

In developing large-scale next-generation superconducting radio frequency (SRF) linear accelerators using superconducting films on Cu, the design and development of dissimilar welding and joining metals, such as Cu to Inconel, stainless steel, and Nb, are essential. In this talk, we present the development of procedures for electron-beam welding of Cu¿Inconel 625 and evaluation of the microstructure and 77K mechanical properties of the weld and base material in the welded condition and heat treatments in the 750°C ¿950°C heat treatment range. The results will be presented in the context of developing joining techniques for low-temperature applications where high conductivity and strength, vacuum hygiene, and magnetic properties of the material need consideration. The methods presented here are being deployed to thin film SRF Cu cavities at Jefferson Lab. Acknowledgment: This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear

Khanal, Bashu

Upper Limit for the 248 Cm( 50 Ti, x n) 298− x Og Reaction Cross Section

After the synthesis of element 113, nihonium (Nh) via the 209 Bi( 70 Zn,n) 278 Nh cold fusion reaction using the RIKEN heavy-ion Linear ACcelerator (RILAC) and the GAs-filled Recoil Ion Separator (GARIS), the search for the heaviest isotopes of oganesson was initiated with GARIS-II by means of the 248 Cm( 50 Ti,xn) 298−x Og fusion evaporation reaction. The optimal bombarding energy for the 50 Ti + 248 Cm reaction was determined from the quasielastic barrier distribution extracted from the excitation function of quasielastic backscattering. Here, this method optimizes the compound nucleus formation. The search for Og was conducted for 39 days on the basis of the experimentally derived 50 Ti beam energy of 227.9(5) MeV at the middle of 248 Cm target. A precise analysis of the dataset based on multiple event search strategies revealed no decay chains with a total dose on 248 Cm target of 4.93 × 10 18 50 Ti projectiles, reaching a sensitivity of 0.27 pb and a 1σ upper cross section limit of 0.50 pb.

Gall, Benoît Jean-Paul [University of Strasbourg (