Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

Surface nanopattern formation due to current-induced homoepitaxial nanowire edge instability

Physical nanopatterning based on a precise control of macroscopic forcing is an essential tool of nanoscale science and technology. Using an externally applied electric field as the macroscopic force, we report here a computational study on the formation of surface nanopatterns consisting of single-layer homoepitaxial islands as a result of a morphological instability that can occur under edge electromigration conditions on the straight edge of a single-layer nanowire grown epitaxially on a crystalline substrate. Direct dynamical simulations based on a model that has been validated experimentally for the Ag/Ag system show that the current-induced nanowire edge instability causes the breakup of the nanowire and leads to the formation of uniformly distributed islands, arranged in linear or V-shaped arrays, which are uniformly sized with nanoscale dimensions. The simulation results are supported by linear stability theory and demonstrate that the geometrical features of the island patterns and the island sizes can be controlled precisely by controlling the electric field direction with respect to the nanowire axis and the electric field strength. Our findings have important implications for developing physical nanopatterning approaches toward enabling future nanofabrication technologies.

36 MATERIALS SCIENCE↗

Advanced Millimeter-Wave Security Portal Imaging Techniques

Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

99 GENERAL AND MISCELLANEOUS↗

Advanced Millimeter-Wave Imaging Enhances Security Screening

Millimeter-wave imaging is rapidly gaining acceptance for passenger screening at airports and other secured facilities. This paper details a number of techniques developed over the last several years including novel image reconstruction and display techniques, polarimetric imaging techniques, array switching schemes, as well as high frequency high bandwidth techniques. Implementation of some of these methods will increase the cost and complexity of the mm-wave security portal imaging systems. RF photonic methods may provide new solutions to the design and development of the sequentially switched linear mm-wave arrays that are the key element in the mm-wave portal imaging systems.

Imaging↗

A high performance neutron powder diffractometer at 3 MW Triga Mark-II research reactor in Bangladesh

A high performance neutron diffractometer called Savar Neutron Diffractometer (SAND) was built and installed at radial beam port-2 of TRIGA Mark II research reactor at AERE, Savar, Dhaka, Bangladesh. Structural studies of materials are being done by this technique to characterize materials crystallograpohically and magnetically. The micro-structural information obtainable by neutron scattering method is very essential for determining its technological applications. This technique is unique for understanding the magnetic behavior in magnetic materials. Ceramic, steel, electronic and electric industries can be benefited from this facility for improving their products and fabrication process. This instrument consists of a Popovicimonochromator with a large linear position sensitive detector array. The monochromator consists of nine blades of perfect single crystal of silicon with 6 mm thickness each. The monochromator design was optimized to provide maximum flux on 3 mm diameter cylindrical sample with a relatively flat angular dependence of resolution. Five different wave lengths can be selected by orienting the crystal at various angles. A sapphire filter was used before the primary collimator to minimize the first neutron. The detector assembly is composed of 15 linear position sensitive proportional counters placed at either 1.1 m or 1.6 m from the sample position and enclosed in a air pad supported high density polythene shield. Position sensing is obtained by charge division using 1-wide NIM position encoding modules (PEM). The PEMs communicate with the host computer via USB. The detector when placed at 1.1 m, subtends 30° (2θ) at each step and covers 120° in 4 steps. When the detector is placed at 1.6 m it subtends 20° at each step and covers 120° in 6 steps. The instrument supports both low and high temperature sample environment. The instrument supports both low and high temperature sample environment. The diffractometer is a state-of-the art technology for diffraction study in our country.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste - 16648

Measures required to assure long term safe storage of Low-level and intermediate-level short-lived (LIL/SL) waste generated by the nuclear-power industry in France include the characterization of the waste and identification of materials within the waste. Digital Radiography (DR) techniques using x-ray at energies in the 6 MeV range have been shown to be effective for validation of the integrity of the concrete containers, and it was considered that the use of this technique together with the addition of Computed Tomography (CT) techniques could effectively identify materials within the waste. This paper describes the initial evaluation of two DR imaging techniques and two CT techniques using x-ray energy spectra up to 9 MeV to inspect a surrogate waste package, which comprised an outer concrete cylindrical container of 1400 mm diameter with 148 mm wall thickness, and an overall volume of 2 meters cubed, within which a 200 liter drum containing representative heterogeneous inactive waste, was placed in the center and the annulus between the 200 liter drum and the outer cylindrical package was filled with cement grout. The surrogate waste within the 200 liter drum comprised three separate layers of high density, medium density and low density mixed materials. The equipment used was a linear accelerator producing high energy spectra at either 6 MeV or 9 MeV and a high-precision CT manipulator with X, Y, Z and rotation motions, which were common to all techniques investigated. Two different digital detectors were used in the DR and CT performance evaluations, a Digital Detector Array (DDA) comprising a columnar Thallium-doped Cesium-Iodide scintillator screen in intimate contact with a 2 k by 2 k array of amorphous silicon detectors, 200 μm x 200 μm in area, and a Linear Diode Array (LDA) comprising a line of Cadmium-Tungstate columns, 1 cm thick and 400 μm x 400 μm in area. The work comprised evaluations of linear accelerator spectra and the attenuation effects of the waste container and contents, image acquisition performance of each detector, and CT techniques using area detector and linear detector. The results presented in this paper include mathematical evaluation of the two CT techniques, and analysis of measurement data, digital images, CT reconstruction images, and estimated material densities. The data was compared with recorded details and photographs of the actual configuration of materials within the surrogate waste. The Digital Detector Array can generate CT inspection volumes with considerable resolution and detail for the low-density and medium-density sections of the surrogate waste, however, the high-density sections were not imaged with sufficient detail and the images contained a large number of artifacts mainly due to the detectors lack of high energy photon stopping power. Materials identification with the Digital Detector Array, while possible for certain materials, for materials in the steel to plastic density range the attenuation values of the voxels in the reconstruction are too similar and difficult to resolve from the artifacts present. The Linear Diode Array can generate CT inspection volumes of regions of interest of the low-density and medium-density sections with considerable resolution and contrast, and potentially acceptable levels of resolution and contrast of the high-density section of the waste. While a few artifacts were present in the reconstructions, the majority are not due to the fundamental properties of the detector and are considered to be correctable. Materials identification with the LDA inspection data appear to be viable, with steel, copper, and higher-density metals being readily be distinguished from other materials on the basis of voxel value. Future work is needed to obtain a better definition of optimum spatial resolution and inspection speed, and to develop a system of 'calibration rods' which would consist of a series of 50 mm diameter cylinders of 7 materials; Plastic, Teflon, Concrete, Aluminum, Copper, Tungsten and Lead. The cylinders will be distributed at a certain radius in the surrogate waste and will be used as reference points in the evaluation and demonstration of the contrastive performance for the low, medium and high-density cases. The ability to identify the materials within a sealed waste container, by nondestructive examination, enables the verification of waste acceptance criteria without the need to open the waste containers. This eliminates the need for complex and expensive equipment to open and remotely handle the intermediate level waste, avoids potential hazards and risk of personnel dose uptake, and does not increase the volume of waste caused by repackaging of materials after examination and the decontamination or disposal of equipment used.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Magnetic antenna excitation of whistler modes. IV. Receiving antennas and reciprocity

Antenna radiation patterns are an important property of antennas. Reciprocity holds in free space and the radiation patterns for exciting and receiving antennas are the same. In anisotropic plasmas, radiation patterns are complicated by the fact that group and phase velocities differ and certain wave properties like helicity depend on the direction of wave propagation with respect to the background magnetic field B{sub 0}. Interference and wave focusing effects are different than in free space. Reciprocity does not necessarily hold in a magnetized plasma. The present work considers the properties of various magnetic antennas used for receiving whistler modes. It is based on experimental data from exciting low frequency whistler modes in a large uniform laboratory plasma. By superposition of linear waves from different antennas, the radiation patterns of antenna arrays are derived. Plane waves are generated and used to determine receiving radiation patterns of different receiving antennas. Antenna arrays have radiation patterns with narrow lobes, whose angular position can be varied by physical rotation or electronic phase shifting. Reciprocity applies to broadside antenna arrays but not to end fire arrays which can have asymmetric lobes with respect to B{sub 0}. The effect of a relative motion between an antenna and the plasma has been modeled by the propagation of a short wave packet moving along a linear antenna array. An antenna moving across B{sub 0} has a radiation pattern characterized by an oscillatory “whistler wing.” A receiving antenna in motion can detect any plane wave within the group velocity resonance cone. The radiation pattern also depends on loop size relative to the wavelength. Motional effects prevent reciprocity. The concept of the radiation pattern loses its significance for wave packets since the received signal does not only depend on the antenna but also on the properties of the wave packet. The present results are of fundamental interest and of relevance to loop antennas in space.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

On infrasound generated by wind farms and its propagation in low-altitude tropospheric waveguides

Infrasound from a 60-turbine wind farm was found to propagate to distances up to 90 km under nighttime atmospheric conditions. Four infrasound sensor arrays were deployed in central New Mexico in February 2014; three of these arrays captured infrasound from a large wind farm. The arrays were in a linear configuration oriented southeast with 13, 54, 90, and 126 km radial distances and azimuths of 166°, 119°, 113°, and 111° from the 60 1.6 MW turbine Red Mesa Wind Farm, Laguna Pueblo, New Mexico, USA. Peaks at a fundamental frequency slightly below 0.9 Hz and its harmonics characterize the spectrum of the detected infrasound. The generation of this signal is linked to the interaction of the blades, flow gradients, and the supporting tower. The production of wind-farm sound, its propagation, and detection at long distances can be related to the characteristics of the atmospheric boundary layer. First, under stable conditions, mostly occurring at night, winds are highly stratified, which enhances the production of thickness sound and the modulation of other higher-frequency wind turbine sounds. Second, nocturnal atmospheric conditions can create low-altitude waveguides (with altitudes on the order of hundreds of meters) allowing long-distance propagation. Third, night and early morning hours are characterized by reduced background atmospheric noise that enhances signal detectability. This paper describes the characteristics of the infrasound from a quasi-continuous source with the potential for long-range propagation that could be used to monitor the lower part of the atmospheric boundary layer.

17 WIND ENERGY↗

Magnetothermodynamics: measurements of the thermodynamic properties in a relaxed magnetohydrodynamic plasma

We have investigated the thermodynamics of compressed magnetized plasmas in laboratory experiments and we call these studies ‘magnetothermodynamics’. The experiments are carried out in the Swarthmore Spheromak eXperiment device. Here, a magnetized plasma source is located at one end and at the other end, a closed conducting can is installed. We generate parcels of magnetized plasma and observe their compression against the end wall of the conducting cylinder. The plasma parameters such as plasma density, temperature and magnetic field are measured during compression using HeNe laser interferometry, ion Doppler spectroscopy and a linear ${\dot{B}}$ probe array, respectively. To identify the instances of ion heating during compression, a PV diagram is constructed using measured density, temperature and a proxy for the volume of the magnetized plasma. Different equations of state are analysed to evaluate the adiabatic nature of the compressed plasma. A three-dimensional resistive magnetohydrodynamic code (NIMROD) is employed to simulate the twisted Taylor states and shows stagnation against the end wall of the closed conducting can. The simulation findings are consistent to what we observe in our experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mechanism of Mesoscale Woodpile Development via Photoelectrochemical Deposition of Se–Te

A combination of experiments and optical modeling provided insight into the mechanism of mesoscale woodpile formation in response to an orthogonal shift in polarization during photoelectrochemical deposition of Se–Te. Cathodic deposition of semiconducting Se–Te using spatially uniform, linearly polarized illumination produced arrays of lamellae that were aligned parallel to the optical E-field oscillation. Continued deposition in conjunction with an orthogonal shift in the polarization direction then produced aligned bridging features that spanned the void space between, and were orthogonal to, the preexisting lamellae. The height and pitch, respectively, in each layer of the woodpile were a function of the charge density and illumination wavelength during deposition. A Monte Carlo model, in which material addition was scaled by the absorption magnitude obtained from electromagnetic simulations, produced morphologies that were nominally identical to those observed experimentally. Here, the formation of mesoscale woodpiles is consistent with a mechanism that involves a series of spontaneously initiated, concerted light–matter interactions during the photoelectrochemical deposition process.

absorption↗

Comparison of four MPPT techniques for PV systems

The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, for all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.

14 SOLAR ENERGY↗

Integration of Ag-CBRAM crossbars and Mott ReLU neurons for efficient implementation of deep neural networks in hardware

In-memory computing with emerging non-volatile memory devices (eNVMs) has shown promising results in accelerating matrix-vector multiplications. However, activation function calculations are still being implemented with general processors or large and complex neuron peripheral circuits. Here, we present the integration of Ag-based conductive bridge random access memory (Ag-CBRAM) crossbar arrays with Mott rectified linear unit (ReLU) activation neurons for scalable, energy and area-efficient hardware (HW) implementation of deep neural networks. We develop Ag-CBRAM devices that can achieve a high ON/OFF ratio and multi-level programmability. Compact and energy-efficient Mott ReLU neuron devices implementing ReLU activation function are directly connected to the columns of Ag-CBRAM crossbars to compute the output from the weighted sum current. We implement convolution filters and activations for VGG-16 using our integrated HW and demonstrate the successful generation of feature maps for CIFAR-10 images in HW. Our approach paves a new way toward building a highly compact and energy-efficient eNVMs-based in-memory computing system.

Mott insulators↗

Development of Tunable, Precision Permanent Magnet Phase Shifter for X-Ray FEL

In an X-ray free-electron laser (XFEL), a high quality relativistic electron beam from a linear accelerator traverses an array of undulator magnets to generate a high power X-ray beam by allowing the FEL to reach saturation. In many XFELs, phase shifters haven’t been commonly used or included in their designs. The importance of the phase shifter was recognized only recently. A phase shifter can be constructed using either an electromagnet (EM) or a permanent magnet (PM). EM phase shifters are heavy, complex to operate, and take more valuable longitudinal space between the undulators. Compared to EMs, the PMs have several outstanding advantages, including compactness, lighter weights, simple operation, and low maintenance. This project has developed an innovative design of fixed-gap, tunable PM-based compact phase shifter for the XFEL. While keeping the poles and gap fixed, the new design incorporates proven features from the prior work, along with novel field tuning methods, which allow the field strength to be adjusted within a reasonably large range to achieve the desired range of the phase delay control. The PM design without electric currents and power electronics associated with EMs improves reliability by reducing the number of possible points of failure and lowers the operation cost. The compactness makes it possible to use PM phase shifters in the existing XFELs with small gaps between adjacent undulators, as well as in the new XFELs without significantly increasing the FEL length. In Phase I we have accomplished the followings; 1) determined the optimum physics parameters for both weak and strong phase shifters; 2) conducted magnetic design with concrete magnetic and geometrical parameters of actual produced PM materials; 3) provided solutions to achieve precision fine tuning of the magnetic fields with unique methods; 4) elaborated a design based upon ease of manufacturing and cost analysis; and 5) produced rare-earth PM materials, which will be used for prototyping in Phase II. The phase I results provide a foundation for the research and development in the Phase II project, which will aim at building two full-size PM phase shifters and testing at SLAC National Accelerator Laboratory. This project will significantly provide the potential to bring a paradigm change in accelerator technology, replacing conventional electromagnets for many existing accelerator applications and allowing the development of new applications in completely new areas. For example, the PM FEL phase shifters can help significantly improve coherence and power of an XFEL. The proposed use of PM phase shifters will also bring significant cost savings to the construction, operation and maintenance of FEL facilities.

43 PARTICLE ACCELERATORS↗

An accurate locally active memristor model for S-type negative differential resistance in NbO{sub x}

A number of important commercial applications would benefit from the introduction of easily manufactured devices that exhibit current-controlled, or “S-type,” negative differential resistance (NDR). A leading example is emerging non-volatile memory based on crossbar array architectures. Due to the inherently linear current vs. voltage characteristics of candidate non-volatile memristor memory elements, individual memory cells in these crossbar arrays can be addressed only if a highly non-linear circuit element, termed a “selector,” is incorporated in the cell. Selectors based on a layer of niobium oxide sandwiched between two electrodes have been investigated by a number of groups because the NDR they exhibit provides a promisingly large non-linearity. We have developed a highly accurate compact dynamical model for their electrical conduction that shows that the NDR in these devices results from a thermal feedback mechanism. A series of electrothermal measurements and numerical simulations corroborate this model. These results reveal that the leakage currents can be minimized by thermally isolating the selector or by incorporating materials with larger activation energies for electron motion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spectral and angular characteristics of dielectric resonator metasurface at optical frequencies

The capability of manipulating light at subwavelength scale has fostered the applications of flat metasurfaces in various fields. Compared to metallic structure, metasurfaces made of high permittivity low-loss dielectric resonators hold the promise of high efficiency by avoiding high conductive losses of metals at optical frequencies. This letter investigates the spectral and angular characteristics of a dielectric resonator metasurface composed of periodic sub-arrays of resonators with a linearly varying phase response. The far-field response of the metasurface can be decomposed into the response of a single grating element (sub-array) and the grating arrangement response. The analysis also reveals that coupling between resonators has a non-negligible impact on the angular response. Over a wide wavelength range, the simulated and measured angular characteristics of the metasurface provide a definite illustration of how different grating diffraction orders can be selectively suppressed or enhanced through antenna sub-array design.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-power 850-870-nm pulsed lasers based on heterostructures with narrow and wide waveguides

The power and spectral characteristics of pulsed laser diode arrays operating in the spectral range of 850-870 nm and based on heterostructures of two different types (with narrow and wide waveguides) are studied. It is found that the power-current characteristics of the laser arrays of both types are linear within the pump current range of 10-50 A and that the steepness of these characteristics decreases at currents exceeding 80 A. The decrease in the slope efficiency is more noticeable for laser arrays based on heterostructures with wide waveguides. (semiconductor lasers. physics and technology)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiological Shielding Design for the Neutron Backscattering Spectrometer EMU

In this paper we present modelling and design of compact radiation shielding required for operation of the EMU instrument, located at Australia's OPAL nuclear reactor. The acceptance criteria for the shielding design were (i) safety - dose rate ≤ 3 μSv/h at external surfaces of the instrument's experimental area, (ii) floor load limit < 20 tons/m{sup 2}, (iii) low cost and (iv) for maintenance purposes 'easy access' to components of the instruments. The EMU instrument is a cold neutron backscattering spectrometer designed to measure inelastic neutron scattering. Its distinctive feature is that it has a tight elastic energy transfer resolution, of about 1 μeV. The instrument provides unique opportunities to study diffusion in complex materials, e.g. water molecules in confinement, polymers or biological molecules, particularly in the Asia-Oceania region. EMU is the first instrument located on the CG3 neutron beam line of the OPAL Neutron Guide Hall (NGH). A pre-existing evacuated neutron guide of dimensions 200 mm (height) x 50 mm (width) feeds into the shared EMU/KOOKABURRA pre-monochromator bunker shielding assembly, and its bottom cross section will be intercepted ∼200 mm further in air by the highly orientated pyrolytic graphite (HOPG) EMU pre-monochromator (take-off angles from 125.4 deg. to 148 deg.). The bunker shielding assembly for EMU also contains a beryllium filter and Focusing Guide Section D (FGD, 170 mm (height) x 50 mm (width)). To accommodate the range of take-off angles Pb cylindrical shielding blocks of radius 140 mm and 500 mm height have been designed. These blocks will be located at the section of the bunker where the neutron beam will exit towards the experimental area and they will reside on top of a hollow steel base (sides 10 mm thick), on which they move by sliding and are integrated with the tertiary shutter. The experimental area is enclosed by a concrete wall of 2.5 m height and 300 mm thickness, shared with the KOOKABURRA instrument, Gyprock Plasterboard panels with viewing windows, a wall from the Out-of-Pile Bunker and the CG3 shielding. The neutron beam enters the experimental area via the tertiary shutter, into the Focusing Guide Section C (FGC), which has an entrance guide cross-section of 158 mm (height) x 79 mm (width) and exit guide cross-section of 149 mm (height) x 85 mm (width) and is of length 816 mm. The vacuum chamber of FGC will be connected to the vacuum chamber of the Background Chopper (BC, disc of outer radius 350 mm). Focusing Guide Section B (FGB) is aligned with FGC and its vacuum shared with the BC vacuum. The FGB has an exit guide cross section of 50 mm (height) x 49 mm (width) and is of length 4046 mm, which will focus the neutron beam vertically and horizontally towards the Al window entrance (0.82 mm thickness, labelled N16) of the Scattering Tank assembly (constructed from 20 mm - 40 mm thickness stainless steel and will be under vacuum < 1 x 10{sup -3} mbar). Inside the Scattering Tank there is another section of Focusing Guide (FGA), with an exit guide cross-section of 30 mm (height) 30 mm (width) and of length 417 mm. The neutron beam exiting the FGA will be reflected by the HOPG crystal pieces of the Graphite Chopper (GC) towards the Backscattering Monochromator (BM). The reflected neutron beam will first pass through the other Al window (0.82 mm thickness, labelled N17) of the Scattering Tank and then enter into a flight tube (steel of 10 mm thickness). The BM is formed in an 1800 mm spherical radius array of Si crystal elements (0.87 mm thickness) and is oscillated by the linear motor Doppler Drive. The neutron beam will be reflected back at 180 deg. from, and focussed by the BM to reenter the Scattering Tank through the N17 Al window. It will then pass through the GC (HOPG crystals are rotated out of the way) and will reach the scattering sample of interest to the instrument end user. Also, inside the Scattering Tank there will be {sup 3}He linear position-sensitive detectors, and Analyser Arrays formed in an 1800 mm radius spherical arrays of Si crystal elements (0.87 mm thickness) glued on aluminium support frames (10 mm thickness) and span ∼160 deg. arc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Three dimensional metafilms with dual channel unit cells

Three-dimensional (3D) metafilms composed of periodic arrays of silicon unit cells containing single and multiple micrometer-scale vertical split ring resonators (SRRs) per unit cell were fabricated. In contrast to planar and stacked planar structures, these 3D metafilms have a thickness t ~λ d /4, allowing for classical thin film effects in the long wavelength limit. The infrared specular far-field scattering response was measured for metafilms containing one and two resonators per unit cell and compared to numerical simulations. Excellent agreement in the frequency region below the onset of diffractive scattering was obtained. For dense arrays of unit cells containing single SRRs, normally incident linearly polarized plane waves which do not excite a resonant response result in thin film interference fringes in the reflected spectra and are virtually indistinguishable from the scattering response of an undecorated array of unit cells. For the resonant linear polarization, the specular reflection for arrays is highly dependent on the SRR orientation on the vertical face for gap-up, gap-down, and gap-right orientations. For dense arrays of unit cells containing two SRRs per unit cell positioned on adjacent faces, the specular reflection spectra are slightly modified due to near-field coupling between the orthogonally oriented SRRs but otherwise exhibit reflection spectra largely representative of the corresponding single-SRR unit cell structures. Lastly, the ability to pack the unit cell with multiple inclusions which can be independently excited by choice of incident polarization suggests the construction of dual-channel films where the scattering response is selected by altering the incident polarization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗