Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

From Data to Insights: A Covariate Analysis of the IARPA BRIAR Dataset for Multimodal Biometric Recognition Algorithms at Altitude and Range

This paper examines covariate effects on fused whole body biometrics performance in the IARPA BRIAR dataset, specifically focusing on UAV platforms, elevated positions, and distances up to 1000 meters. The dataset includes outdoor videos compared with indoor images and controlled gait recordings. Normalized raw fusion scores relate directly to predicted false accept rates (FAR), offering an intuitive means for interpreting model results. A linear model is developed to predict biometric algorithm scores, analyzing their performance to identify the most influential covariates on accuracy at altitude and range. Weather factors like temperature, wind speed, solar loading, and turbulence are also investigated in this analysis. The study found that resolution and camera distance best predicted accuracy and findings can guide future research and development efforts in long-range/elevated/UAV biometrics and support the creation of more reliable and robust systems for national security and other critical domains.

Bolme, David↗

Sensor Configuration Trade Study for Navigation in near Rectilinear Halo Orbits

Gateway is a NASA program planned to support a human space explorationand prove new technologies for deep space exploration. One of the Gatewayrequirements is to operate in the absence of communications with the Deep SpaceNetwork (DSN) for a period of at least 3 weeks. In this paper three types ofonboard sensors (a camera for optical navigation, a GPS receiver, and X-ray navigation),are considered to enhance its autonomy and reduce the reliance on DSN.A trade study is conducted to explore alternatives on how to achieve autonomy andhow to reduce DSN dependency while satisfying navigation performance requirements.Using linear covariance analysis, the performance of a navigation systemusing DSN and/or the other sensors is shown.

Gateway↗

Optical design of the Moderate Resolution Imaging Spectrometer - Tilt (MODIS-T) for the Earth Observing System (Eos)

The Moderate Resolution Imaging Spectrometer (MODIS) is an Earth viewing sensor that is planned as a facility instrument for the Earth Observing System (Eos) scheduled to begin functioning in the late 1990's. The MODIS is composed of two mutually supporting sensors one of which is MODIS-T, where 'T' signifies a tiltable along-track field of view. MODIS-T is a 32 channel imaging spectrometer with a required 10 nm to 15 nm spectral resolution (FWHM) in the 400 nm to 880 nm spectral range with less than 2.3 percent instrument induced linear polarization. The instrument provides at nadir a 33 km by 1500 km swath with a 1.1 km spatial resolution and an along-track pointing capability of +/- 50 deg about nadir. The heart of the optical design consists of a f/3 grating-type reflecting Schmidt camera.

Maymon, Peter W.↗

The frequency of T Tauri companion stars

We present the results of a magnitude-limited multiplicity survey of T Tauri stars in two nearby star-forming regions, Taurus-Auriga and Ophiuchus-Scorpius. Each of the 69 stars in the sample was observed at K with an infrared array camera on the Hale 5-m Telescope at Palomar Observatory and imaged using 2D speckle imaging techniques. Thirty-three companion stars were found of which 15 were new detections. One of the main results of this survey indicates that the binary star frequency in the projected linear separation range 14 to 225 AU for T Tauri stars is a factor of 3.5 greater than that of the solar-type main-sequence stars. Given the limited angular separation range of this survey, the rate at which binaries are detected suggests that most T Tauri stars have companions. We propose that the observed overabundance of companions to T Tauri stars relative to their older counterparts on the main sequence is an evolutionary effect; in this scheme, triple and higher order T Tauri star systems, which are observed at higher frequencies than for the solar-type main-sequence stars, are disrupted by close encounters with another star or system of stars.

Ghez, A. M.↗

In-Flight Performance of the Polarization Modulator in the CLASP Rocket Experiment

We developed a polarization modulation unit (PMU), a motor system to rotate a waveplate continuously. In polarization measurements, the continuous rotating waveplate is an important element as well as a polarization analyzer to record the incident polarization in a time series of camera exposures. The control logic of PMU was originally developed for the next Japanese solar observation satellite SOLAR-C by the SOLAR-C working group. We applied this PMU for the Chromospheric Lyman‐alpha SpectroPolarimeter (CLASP). CLASP is a sounding rocket experiment to observe the linear polarization of the Lyman‐alpha emission (121.6 nm vacuum ultraviolet) from the upper chromosphere and transition region of the Sun with a high polarization sensitivity of 0.1 % for the first time and investigate their vector magnetic field by the Hanle effect. The driver circuit was developed to optimize the rotation for the CLASP waveplate (12.5 rotations per minute). Rotation non‐uniformity of the waveplate causes error in the polarization degree (i.e. scale error) and crosstalk between Stokes components. We confirmed that PMU has superior rotation uniformity in the ground test and the scale error and crosstalk of Stokes Q and U are less than 0.01 %. After PMU was attached to the CLASP instrument, we performed vibration tests and confirmed all PMU functions performance including rotation uniformity did not change. CLASP was successfully launched on September 3, 2015, and PMU functioned well as designed. PMU achieved a good rotation uniformity, and the high precision polarization measurement of CLASP was successfully achieved.

CLASP↗

Recent developments at JPL in the application of image processing to astronomy

Four applications of image processing to astronomy, automated location and analysis of star and galaxy images, geometric and radiometric decalibration of vidicon spectra, display of multiband radio images, and generation of high resolution polarization direction and magnitude maps from images are presented with illustrative examples. The technique by which a digital image can be analyzed automatically to locate and segregate between stars and galaxies and the steps performed by the classifier to determine the nature of each object are outlined. The classification program executed on a 48 inch Schmidt plate of the cluster of galaxies 655 is described. The calibration and decalibration steps to remove geometric and radiometric distortions from a silicon vidicon camera digital spectra are discussed. Three methods of displaying multispectral radio data, generating a mosaic of each image, producing a color coded image to depict radio velocity, and producing a stereo pair with radial velocity as depth are described. The generation of polarization information from images obtained through linear polarizing filters is illustrated, and it is concluded that in each case information was displayed using digital techniques which could not readily have been provided visually.

Lorre, J. J.↗

High resolution vidicon-based readout system for photon-counting streak camera applications

The design, implementation, and evaluation of a high-resolution vidicon-based reconfigurable imaging system for integration into a photon-counting streak camera that can be readily coupled to a standard interface and computer have been achieved. Experimental results are reported which demonstrate that the design goals are met, providing the capability to measure differential time to better than 3 picosecond accuracy. Augmented by real-time calibration, the accuracy, linearity, noise levels, and stability of the system are adequate to support dual wavelength laser ranging.

Varghese, Thomas K.↗

Fuzzy logic controllers: A knowledge-based system perspective

Over the last few years we have seen an increasing number of applications of Fuzzy Logic Controllers. These applications range from the development of auto-focus cameras, to the control of subway trains, cranes, automobile subsystems (automatic transmissions), domestic appliances, and various consumer electronic products. In summary, we consider a Fuzzy Logic Controller to be a high level language with its local semantics, interpreter, and compiler, which enables us to quickly synthesize non-linear controllers for dynamic systems.

Bonissone, Piero P.↗

Rapid Development of the Seeker Free-Flying Inspector Guidance, Navigation, and Control System

Seeker is an automated extravehicular free-flying inspector CubeSat designed and built in-house at the Johnson Space Center (JSC). As a Class 1E project funded by the International Space Station (ISS) Program, Seeker had a streamlined process to flight certification, but the vehicle had to be designed, developed, tested, and delivered within approximately one year after authority to pro-ceed (ATP) and within a $1.8 million budget. These constraints necessitated an expedited Guidance, Navigation, and Control (GNC) development schedule, development began with a navigation sensor trade study using Linear Covariance (LinCov) analysis and a rapid sensor downselection process, resulting in the use of commercial off-the-shelf (COTS) sensors which could be procured quickly and subjected to in-house environmental testing to qualify them for flight. A neural network was used to enable a COTS camera to provide bearing measurements for visual navigation. The GNC flight software (FSW) algorithms utilized lean development practices and leveraged the Core Flight Software (CFS) architecture to rapidly develop the GNC system, tune the system parameters, and verify performance in simulation. This pace was anchored by several Hardware-Software Integration (HSI) milestones, which forced the Seeker GNC team to develop the interfaces both between hardware and software and between the GNC domains early in the project and to enable a timely delivery.

Sullivan, Jacob↗

Improving galaxy clustering measurements with deep learning: analysis of the DECaLS DR7 data

ABSTRACT Robust measurements of cosmological parameters from galaxy surveys rely on our understanding of systematic effects that impact the observed galaxy density field. In this paper, we present, validate, and implement the idea of adopting the systematics mitigation method of artificial neural networks for modelling the relationship between the target galaxy density field and various observational realities including but not limited to Galactic extinction, seeing, and stellar density. Our method by construction allows a wide class of models and alleviates overtraining by performing k-fold cross-validation and dimensionality reduction via backward feature elimination. By permuting the choice of the training, validation, and test sets, we construct a selection mask for the entire footprint. We apply our method on the extended Baryon Oscillation Spectroscopic Survey (eBOSS) Emission Line Galaxies (ELGs) selection from the Dark Energy Camera Legacy Survey (DECaLS) Data Release 7 and show that the spurious large-scale contamination due to imaging systematics can be significantly reduced by up-weighting the observed galaxy density using the selection mask from the neural network and that our method is more effective than the conventional linear and quadratic polynomial functions. We perform extensive analyses on simulated mock data sets with and without systematic effects. Our analyses indicate that our methodology is more robust to overfitting compared to the conventional methods. This method can be utilized in the catalogue generation of future spectroscopic galaxy surveys such as eBOSS and Dark Energy Spectroscopic Instrument (DESI) to better mitigate observational systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

Safety analysis

We are engaged in a research program in safety-critical computing that is based on two case studies. We use these case studies to provide application-specific details of the various research issues, and as targets for evaluation of research ideas. The first case study is the Magnetic Stereotaxis System (MSS), an investigational device for performing human neurosurgery being developed in a joint effort between the Department of Physics at the University of Virginia and the Department of Neurosurgery at the University of Iowa. The system operates by manipulating a small permanent magnet (known as a 'seed') within the brain using an externally applied magnetic field. By varying the magnitude and gradient of the external magnetic field, the seed can be moved along a non-linear path and positioned at a site requiring therapy, e.g., a tumor. The magnetic field required for movement through brain tissue is extremely high, and is generated by a set of six superconducting magnets located in a housing surrounding the patient's head. The system uses two X-ray cameras positioned at right angles to detect in real time the locations of the seed and of X-ray opaque markers affixed to the patient's skull. the X-ray images are used to locate the objects of interest in a canonical frame of reference. the second case study is the University of Virginia Research Nuclear Reactor (UVAR). It is a 2 MW thermal, concrete-walled pool reactor. The system operates using 20 to 25 plate-type fuel assemblies placed on a rectangular grid plate. There are three scramable safety rods, and one non-scramable regulating rod that can be put in automatic mode. It was originally constructed in 1959 as a 1 MW system, and it was upgraded to 2 MW in 1973. Though only a research reactor rather than a power reactor, the issues raised are significant and can be related to the problems faced by full-scale reactor systems.

Knight, John C.↗

Assessment of holographic microscopy for quantifying marine particle size and concentration

Holographic microscopy has emerged as a tool for in situ imaging of microscopic organisms and other particles in the marine environment: appealing because of the relatively larger sampling volume and simpler optical configuration compared to other imaging systems. However, its quantitative capabilities have so far remained uncertain, in part because hologram reconstruction and image recognition have required manual operation. Here, we assess the quantitative skill of our automated hologram processing pipeline (CCV Pipeline), to evaluate the size and concentration measurements of environmental and cultured assemblages of marine plankton particles, and microspheres. Over 1 million particles, ranging from 10 to 200 μm in equivalent spherical diameter, imaged by the 4‐Deep HoloSea digital inline holographic microscope (DIHM) are analyzed. These measurements were collected in parallel with a FlowCam (FC), Imaging FlowCytobot (IFCB), and manual microscope identification. Once corrections for particle location and nonuniform illumination were developed and applied, the DIHM showed an underestimate in ESD of about 3% to 10%, but successfully reproduced the size spectral slope from environmental samples, and the size distribution of cultures (Dunaliella tertiolecta, Heterosigma akashiwo, and Prorocentrum micans) and microspheres. DIHM concentrations (order 1 to 1000 particles ml(exp −1)) showed a linear agreement (r(exp 2) = 0.73) with the other instruments, but individual comparisons at times had large uncertainty. Overall, we found the DIHM and the CCV Pipeline required extensive manual correction, but once corrected, provided concentration and size estimates comparable to the other imaging systems assessed in this study. Holographic cameras are mechanically simple, autonomous, can operate at very high pressures, and provide a larger sampling volume than comparable lens‐based tools. Thus, we anticipate that these characterization efforts will be rewarded with novel discovery in new oceanic environments.

Noah L. Walcutt↗

Dust Lifting Observations with the Mars Science Laboratory Navigation Cameras

Martian dust lifting is believed to occur through two primary mechanisms: dust devils and wind stress forced dust lifting. Gale Crater's varied terrain and meteorology provide a unique in situ perspective on Martian dust lifting, with the Mars Science Laboratory Curiosity rover passing through both conditions and locations detrimental to dust lifting (e.g., the crater floor) and those with active sand motion and frequent dust lifting (e.g., the Bagnold Dunes). Between L s = 248° in Mars Year 33 and L s = 51° in Mars Year 37, over ∼3.5 Mars years and 2,300 sols, the rover's Navigation Cameras took 1,260 dedicated image sequences to search for dust lifting. Approximately 42.7% of all sequences, and 9.5% of the total images have shown active dust lifting, both dust devils and linear/straight-line wind stress dust lifting. 79% of dust lifting events are classified as dust devils, while ∼16% are linear wind stress dust lifting and the remainder are of an indeterminate type. We analyze this large catalog of dust lifting events to provide ground truth on theoretical and model expectations of dust lifting and show that dust lifting in Gale Crater occurs throughout the Martian year, is strongly peaked in frequency near solar noon (even after accounting for observational biases), and that dust lifting shows an affinity for sand-covered surfaces which highlights the importance of saltating sand grains for Martian dust lifting in both dust devils and wind stress forced lifting.

Scott D. Guzewich↗

Rapid Development of the Seeker Free-Flying Inspector Guidance, Navigation, and Control System

Seeker is an automated extravehicular free-flying inspector CubeSat designed and built in-house at the Johnson Space Center (JSC). As a Class 1E project funded by the International Space Station (ISS) Program, Seeker had a stream-lined process to flight certification, but the vehicle had to be designed, developed, tested, and delivered within approximately one year after authority to proceed (ATP) and within a $1.8 million budget. These constraints necessitated an expedited Guidance, Navigation, and Control (GNC) development schedule. Development began with a navigation sensor trade study using Linear Covariance (LinCov) analysis and a rapid sensor down-selection process, resulting in the use of commercial off-the-shelf (COTS) sensors which could be procured quickly and subjected to in-house environmental testing to qualify them for flight. A neural network was used to enable a COTS camera to provide bearing measure-ments for visual navigation. The GNC flight software (FSW) algorithms utilized lean development practices and leveraged the Core Flight Software (CFS) architecture to rapidly develop the GNC system, tune the system parameters, and verify performance in simulation. This pace was anchored by several Hardware-Software Integration (HSI) milestones, which forced the Seeker GNC team to develop the interfaces both between hardware and software and between the GNC domains early in the project and to enable a timely delivery.

Sullivan, Jake↗

Periodic Narrowband Radio Wave Emissions and Inward Plasma Transport at Saturn's Magnetosphere

The abrupt brightening of an Energetic Neutral Atom (ENA) blob or cloud has been interpreted as plasma injection in the Kronian magnetosphere (termed ENA injection herein). Morphologically, there appears to be two types of abrupt ENA cloud brightening: (1) the brightening of a large cloud usually seen at distances >10–12 R {sub s} (R {sub s} ∼ 60,268 km) in the midnight or postmidnight region; (2) the brightening of a smaller cloud usually seen at distances <10–12 R {sub s} around 21–03 magnetic local time. Among many radio waves observed at Saturn, type 2 ENA injections correlate best with the 5 kHz narrowband (NB) waves. Using Cassini Ion and Neutral Camera (INCA) and Radio and Plasma Wave Science (RPWS) data, we examine the periodicities of the type 2 ENA injections and the 5 kHz NB emissions as well as their cross-correlations, which have been previously used to measure the lag times or phase differences. Because correlational analysis can only establish linear relationships, we also use mutual information to establish linear and nonlinear relationships. On average, the peak of the 5 kHz NB emission lags those of the type 2 ENA injection by about a few minutes to 2 hr. The injection of hot plasma to the inner magnetosphere can lead to temperature anisotropy, which can generate electrostatic upper hybrid waves, which upon encountering the high-density gradient at the outer edge of the Enceladus density torus, can mode convert to Z mode and then to O mode. The 5 kHz NB waves commonly propagate in the O mode.

79 ASTRONOMY AND ASTROPHYSICS↗

Image reproduction with interactive graphics

Software application or development in optical image digital data processing requires a fast, good quality, yet inexpensive hard copy of processed images. To achieve this, a Cambo camera with an f 2.8/150-mm Xenotar lens in a Copal shutter having a Graflok back for 4 x 5 Polaroid type 57 pack-film has been interfaced to an existing Adage, AGT-30/Electro-Mechanical Research, EMR 6050 graphic computer system. Time-lapse photography in conjunction with a log to linear voltage transformation has resulted in an interactive system capable of producing a hard copy in 54 sec. The interactive aspect of the system lies in a Tektronix 4002 graphic computer terminal and its associated hard copy unit.

Buckner, J. D.↗

Design of a High Flux Beam Characterization Device for Falling Particle Receivers

This paper outlines the design and error analysis for a flux characterization device (i.e. flux wand) which traverses the aperture of a falling particle receiver cavity providing the incident power measurement needed for the calculation of receiver efficiency without significantly disrupting receiver output. The design features a linear actuator, water cooled extension arm, and refractory bar. The refractory bar/flux wand is a diffusely reflective surface which reflects light as it is translated across the receiver aperture to provide a light intensity distribution that is correlated to a measured flux. The component sizing, constrained by a typical 30 frame per second camera and a 4-point average of the measured reflectance, is presented. Simulation reveals the error that results from a 5% variation in flux wand reflectance is within 4% of the true value.

Schroeder, Nathan↗