Search NASA⌕ Search

SEARCH · Search NASA

Results for “load calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 217 records · Page 12

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗

A surprising proliferation of detwinning in β -tin at extreme loading rates

Integrating data from dynamic compression experiments of condensed matter across three national laboratories has led to insight and quantitative calibration of materials strength over decades of loading rate. For many materials, a single strength model (such as PTW) is sufficient to capture the flow-stress strain rate relationship which is monotonic. Here, we show here that β -tin, a tetragonal metal, exhibits dramatic deviations from this behavior. Naive fitting to a single PTW model is insufficient to capture the behavior; indeed, such resulting inferred flow stress versus strain exhibits a non-monotonic behavior. We suggest a resolution to this by proposing that in β -tin there are important Bauschinger effects arising from favorable conditions for twinning and detwinning. A simple yield surface model when paired with PTW hardening captures the experimental data.

36 MATERIALS SCIENCE↗

Calibrated clamp facilitates pressure application

Spring-loaded clamp applies specific pressure to hold materials together during bonding, welding, and machining. The clamp has two adjustable legs terminating in suction cups for easy attachment to a surface.

Source record↗

Using probabilistic analysis to assess the reliability of predicted SRB aft-skirt stresses

Probabilistic failure analysis is a tool to predict the reliability of a part or system. Probabalistic techniques were used to predict critical stresses which occur in the solid rocket booster aft-skirt during main engine buildup, immediately prior to lift-off. More than any other hold down post (HDP) load component, the Z loads are sensitive to variations in strains and calibration constants. Also, predicted aft-skirt stresses are strongly affected by HDP load variations. Therefore, the instrumented HDP are not effective load transducers for Z loads, and, when used with aft skirt stress indicator equations, yield estimates with large uncertainty. Monte Carlo simulation proved to be a straight forward way of studying the overlapping effects of multiple parameters on predicted equipment performance. An advantage of probabilistic analysis is the degree of uncertainty of each parameter as stated explicitly by its probability distribution. It was noted, however, that the choice of parameter distribution had a large effect on the simulation results. Many times these distributions must be assumed. The engineer who is designing the part should be responsible for the choice of parameter distribution.

Richardson, James A.↗

Bayesian calibration of a physics-based crystal plasticity and damage model

In this work, we present a model parameter calibration procedure for a physics-based crystal plasticity model. The calibration process utilizes a powerful statistics-based Bayesian calibration method. Calibration of the crystal plasticity parameters makes use of experimentally-measured data, i.e. compressive stress–strain response, from $\langle$100$\rangle$ and $\langle$123$\rangle$ single crystal copper dynamically loaded via Kolsky bar tests. The calibration of damage parameters is achieved using experimentally-measured free-surface velocity history data from plate impact test on $\langle$100$\rangle$ and $\langle$110$\rangle$ single crystal copper, which generates shock compression followed by dynamic tensile failure. A validation assessment is then carried out by comparing the calibrated model predictions and experimental measurements of the dynamic tensile damage generated in an impacted bicrystal copper plate. Lastly, a model-informed rationale for the experimentally-observed dependence of the spatial distribution of ductile damage (porosity) on crystallography is provided.

42 ENGINEERING↗

Temperature-Averaging Thermal Probe

Temperature-averaging thermal probe measures long-term temperature fluctuations in fluid environment. Consists of temperature probe embedded inside thermally massive material. Probe measurements used to estimate powerplant heating and cooling loads, map temperature profiles, and calibrate more-sensitive temperature probes.

Kalil, L. F.↗

Ultrasonic pulsed phase locked loop interferometer for bolt load measurements

The pulsed phase-locked-loop bolt monitor (P2L2) that uses ultrasonic waves to measure bolt preload with accuracies ranging from 1 to 3 percent (depending on the specific bolt) is described. To remeasure bolt load after installation, a thermal calibration factor compensates for bolt temperature changes, and a standard reference block allows correction for acoustic phase errors due to measurement equipment configuration such as utilization of a different transducer, couplant, or cable. Some examples of critical applications including Space Shuttle landing-gear wheels and NASA wind-tunnel fan blades are discussed.

Allison, S. G.↗

Graphical and Numerical Description of Strain-Gage Balance Interactions

A new approach for the graphical and numerical description of balance interactions is presented. The approach uses data from single-component loads as input. This choice has the two advantages. First, the number of applied loads is at the minimum needed for interactions to be observed. In addition, the loads used for the description of interactions can easily be repeated at different sites. Output differences relative to the outputs of the zero load point of a load series are used for the description of interactions. Similarly, load differences relative to the loads of the zero load point of a load series are used for the description of the loads. Interactions are plotted versus the load differences for each load component while omitting the outputs of the primary gage of the chosen load component. The resulting plots have a characteristic star pattern as interactions are zero at zero load. Numerical estimates of the slopes of the interactions can be reverse-engineered from the load prediction equations of a balance if calibration data is examined. The slopes are the off-diagonal coefficients of the inverse of the matrix that has the coefficients of the linear terms of the fitted loads if the Non-Iterative Method is used for the analysis. Similarly, the slopes are the off-diagonal coefficients of the inverse of the matrix that is the non-iterative part of the primary load iteration equation if the Iterative Method is used for the analysis. Data from the calibration of a force balance is processed to illustrate the proposed graphical and numerical description of interactions.

wind tunnel test↗

RF Reference Switch for Spaceflight Radiometer Calibration

The goal of this technology is to provide improved calibration and measurement sensitivity to the Soil Moisture Active Passive Mission (SMAP) radiometer. While RF switches have been used in the past to calibrate microwave radiometers, the switch used on SMAP employs several techniques uniquely tailored to the instrument requirements and passive remote-sensing in general to improve radiometer performance. Measurement error and sensitivity are improved by employing techniques to reduce thermal gradients within the device, reduce insertion loss during antenna observations, increase insertion loss temporal stability, and increase rejection of radar and RFI (radio-frequency interference) signals during calibration. The two legs of the single-pole double-throw reference switch employ three PIN diodes per leg in a parallel-shunt configuration to minimize insertion loss and increase stability while exceeding rejection requirements at 1,413 MHz. The high-speed packaged diodes are selected to minimize junction capacitance and resistance while ensuring the parallel devices have very similar I-V curves. Switch rejection is improved by adding high-impedance quarter-wave tapers before and after the diodes, along with replacing the ground via of one diode per leg with an open circuit stub. Errors due to thermal gradients in the switch are reduced by embedding the 50-ohm reference load within the switch, along with using a 0.25-in. (approximately equal to 0.6-cm) aluminum prebacked substrate. Previous spaceflight microwave radiometers did not embed the reference load and thermocouple directly within the calibration switch. In doing so, the SMAP switch reduces error caused by thermal gradients between the load and switch. Thermal issues are further reduced by moving the custom, highspeed regulated driver circuit to a physically separate PWB (printed wiring board). Regarding RF performance, previous spaceflight reference switches have not employed high-impedance tapers to improve rejection. The use of open-circuit stubs instead of a via to provide an improved RF short is unique to this design. The stubs are easily tunable to provide high rejection at specific frequencies while maintaining very low insertion loss in-band.

Knuble, Joseph↗

Development of a Non-Iterative Balance Load Prediction Algorithm for the NASA Ames Unitary Plan Wind Tunnel

A non-iterative load prediction algorithm for strain-gage balances was developed for the NASA Ames Unitary Plan Wind Tunnels that computes balance loads from the electrical outputs of the balance bridges and a set of state variables. A state variable could be, for example, a balance temperature difference or the bellows pressure of a flow-through balance. The algorithm directly uses regression models of the balance loads for the load prediction that were obtained by applying global regression analysis to balance calibration data. This choice greatly simplifies both implementation and use of the load prediction process for complex balance configurations as no load iteration needs to be performed. The regression model of a balance load is constructed by using terms from a total of nine term groups. Four term groups are derived from a Taylor Series expansion of the relationship between the load, gage outputs, and state variables. The remaining five term groups are defined by using absolute values of the gage outputs and state variables. Terms from these groups should only be included in the regression model if calibration data from a balance with known bi-directional outputs is analyzed. It is illustrated in detail how global regression analysis may be applied to obtain the coefficients of the chosen regression model of a load component assuming that no linear or massive near-linear dependencies between the regression model terms exist. Data from the machine calibration of a six-component force balance is used to illustrate both application and accuracy of the non-iterative load prediction process.

Ulbrich, Norbert M.↗

Graphical and Numerical Description of Strain-Gage Balance Interactions

A new approach for the graphical and numerical description of strain-gage balance interactions is presented. The approach uses data from single-component loads as input. This choice has the two advantages. First, the number of applied loads is at the minimum needed for interactions to be observed. In addition, the loads used for the description of interactions can easily be repeated at different sites. Output differences relative to the outputs of the zero load point of a load series are used for the description of interactions. Similarly, load differences relative to the loads of the zero load point of a load series are used for the description of the loads. Interactions are plotted versus the load differences for each load component while omitting outputs of the primary gage of the chosen load component. The resulting plots have a star pattern as all interactions are zero at zero load. Estimates of the slopes of the interactions can be obtained from the load prediction equations of a balance if calibration data is examined. The slopes are the off-diagonal coefficients of the inverse of the matrix that has the coefficients of the linear terms of the fitted loads if the Non-Iterative Method is used for the analysis. Similarly, the slopes are the off-diagonal coefficients of the inverse of the matrix that is the non-iterative part of the primary load iteration equation if the Iterative Method is used for the analysis. Data sets from a manual and a machine calibration of a force balance are processed to illustrate the proposed description of interactions.

strain-gage balance↗

Temperature profiles in high gradient furnaces

Accurate temperature measurement of the furnace environment is very important in both the science and technology of crystal growth as well as many other materials processing operations. A high degree of both accuracy and precision is acutely needed in the directional solidification of compound semiconductors in which the temperature profiles control the freezing isotherm which, in turn, affects the composition of the growth with a concomitant feedback perturbation on the temperature profile. Directional solidification requires a furnace configuration that will transport heat through the sample being grown. A common growth procedure is the Bridgman Stockbarger technique which basically consists of a hot zone and a cold zone separated by an insulator. In a normal growth procedure the material, contained in an ampoule, is melted in the hot zone and is then moved relative to the furnace toward the cold zone and solidification occurs in the insulated region. Since the primary path of heat between the hot and cold zones is through the sample, both axial and radial temperature gradients exist in the region of the growth interface. There is a need to know the temperature profile of the growth furnace with the crystal that is to be grown as the thermal load. However it is usually not feasible to insert thermocouples inside an ampoule and thermocouples attached to the outside wall of the ampoule have both a thermal and a mechanical contact problem as well as a view angle problem. The objective is to present a technique of calibrating a furnace with a thermal load that closely matches the sample to be grown and to describe procedures that circumvent both the thermal and mechanical contact problems.

Fripp, A. L.↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within +/-0.05% the entire system has an accuracy of +/-0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

Automatic force balance calibration system

A system for automatically calibrating force balances is provided. The invention uses a reference balance aligned with the balance being calibrated to provide superior accuracy while minimizing the time required to complete the calibration. The reference balance and the test balance are rigidly attached together with closely aligned moment centers. Loads placed on the system equally effect each balance, and the differences in the readings of the two balances can be used to generate the calibration matrix for the test balance. Since the accuracy of the test calibration is determined by the accuracy of the reference balance and current technology allows for reference balances to be calibrated to within .+-.0.05%, the entire system has an accuracy of a .+-.0.2%. The entire apparatus is relatively small and can be mounted on a movable base for easy transport between test locations. The system can also accept a wide variety of reference balances, thus allowing calibration under diverse load and size requirements.

Ferris, Alice T.↗

Millimeter wavelength spectroscopy and continuum studies of the planets

Careful observations were made at 86.1 GHz to derive the absolute brightness temperatures of the Sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7K), and Saturn (153.4 + or - 4.8 K) with a standard error of about 3%. This is a significant improvement in accuracy over previous results. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the MWO 4.9 m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5 mm wavelength.

Vandenbout, P. A.↗

Absolute brightness temperature measurements at 3.5-mm wavelength

Careful observations have been made at 86.1 GHz to derive the absolute brightness temperatures of the sun (7914 + or - 192 K), Venus (357.5 + or - 13.1 K), Jupiter (179.4 + or - 4.7 K), and Saturn (153.4 + or - 4.8 K) with a standard error of about three percent. This is a significant improvement in accuracy over previous results at millimeter wavelengths. A stable transmitter and novel superheterodyne receiver were constructed and used to determine the effective collecting area of the Millimeter Wave Observatory (MWO) 4.9-m antenna relative to a previously calibrated standard gain horn. The thermal scale was set by calibrating the radiometer with carefully constructed and tested hot and cold loads. The brightness temperatures may be used to establish an absolute calibration scale and to determine the antenna aperture and beam efficiencies of other radio telescopes at 3.5-mm wavelength.

Ulich, B. L.↗